Tender For Certain Repairs, Comprehensive Maintenance And Servicing Of Electric Lifts (Make: Monarch) Installed At Fleet Office, Fmu Complex, Mwc, Nmrl Complex, Cg Dock Accommodation, Naval Dockyard And Pcda (Navy) Under Ge (Nw) Kunjali, Mumbai
Tender Overview
Project Description
Tender for Certain Repairs, Comprehensive Maintenance And Servicing Of Electric Lifts (Make: Monarch) Installed At Fleet Office, Fmu Complex, Mwc, Nmrl Complex, Cg Dock Accommodation, Naval Dockyard And Pcda (Navy) Under Ge (Nw) Kunjali, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER (NAVAL WORKS) MUMBAI Name of Work :CERTAIN REPAIRS, COMPREHENSIVE MAINTENANCE AND SERVICING OF ELECTRIC LIFTS (MAKE: MONARCH) INSTALLED AT FLEET OFFICE, FMU COMPLEX, MWC, NMRL COMPLEX, CG DOCK ACCOMMODATION, NAVAL DOCKYARD AND PCDA (NAVY) UNDER GE (NW) KUNJALI, MUMBAI Contract No: 8114/CWE (NW) MUMBAI/E8 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item Code / Make Quantity Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling and taking out the existing old/unserviceable stainless steel car door assembly of the 08-passenger (08 PS/544 kg) lift installed in Buildings R-36, R-37 and R-40, including the complete door operator assembly with motor, gear mechanism, variable voltage variable frequency (VVVF) drive system and associated fittings. Supply and fixing of new stainless steel car door assemblies of suitable sheet thickness (SWG), complete with compatible motorised door operator, gear mechanism, VVVF drive system, necessary brackets, hangers, guides, safety contacts, wiring and all associated accessories for the respective lifts in Buildings R-36 and R-37. The work shall include installation, alignment, adjustment, integration with the existing lift control systems, testing and commissioning to ensure smooth, safe and satisfactory operation, complete all as specified and directed by the Engineer-in-Charge. |
| 3 | Ditto all as per Item No. 1.00 above, but for 13-passenger (13 PS/884 kg) capacity lifts installed in Buildings R-20 , R-21 and R-40 complete all as specified and directed by the Engineer-in-Charge. |
| 4 | Ditto all as per Item No. 1.00 above, but for goods lifts of 2000 kg capacity installed in Buildings R-20 and R-21, complete all as specified and directed by the Engineer-in-Charge. |
| 5 | Dismantling and taking out the existing old/unserviceable stainless steel landing door assemblies for the 08-passenger (08 PS/544 kg) lifts installed in Buildings R-36 , R-37 and R-40. from the various floors, including the existing door headers, locking arrangements, brake safety contacts and all associated fittings. Supply and fixing of new stainless steel, centre-opening, horizontally sliding automatic landing doors of suitable sheet thickness (SWG), matching the existing size, design and configuration, complete with aluminium sills, brackets, bearings, safety contacts, electromagnetic gate locks, hangers and all necessary accessories. The work shall also include dismantling, installation, alignment, adjustment, necessary masonry work and making good all disturbed surfaces, along with testing and commissioning to ensure safe and satisfactory operation with the existing lift systems in Buildings R-36 and R-37, complete all as specified and directed by the Engineer-in-Charge |
| 6 | Ditto all as per Item No. 4.00 above, but for 13-passenger (13 PS/884 kg) capacity lifts installed in Buildings R-20 , R-21 and R-40 complete all as specified and directed by the Engineer-in-Charge. |
| 7 | Ditto all as per Item No. 4.00 above, but for goods lifts of 2000 kg capacity installed in Buildings R-20 and R-21, complete all as specified and directed by the Engineer-in-Charge |
| 8 | Supply and fixing, in repairs , of a set of four sealed, maintenance-free batteries, each rated at 12 V, 18 Ah, with a two-year maintenance-free warranty, including disconnection and removal of existing unserviceable batteries, installation, connection, testing and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge. |
| 9 | Material and labour for dismantling and removal of the existing old/unserviceable lift control panel and control wiring, and supply and fixing of a new CAN bus integrated, drive-based collective control panel housed in a hinged, powder-coated mild steel cabinet. The panel shall comprise a microcontroller-based programmable control system using pulse-width modulation (PWM) technology, compatible with an 18 kW (24 HP) variable voltage variable frequency (VVVF) drive, and shall incorporate all necessary safety features, including thermal overload protection, overcurrent protection, automatic phase reversal protection and networking/intercommunication between the connected control units. The work shall include complete control wiring, proper connections using suitable cable lugs, terminal connectors, screws and accessories, galvanised sheet-steel trunking of 24 SWG thickness, wiring of the main motor using suitably sized stranded copper cables, termination, integration with existing lift components, testing and commissioning, complete all as specified and directed by the Engineer-in-Charge. |
| 10 | Supply and fixing in repairs of the main pulley/traction sheave of the lift machine, including dismantling and removal of the existing old/unserviceable main pulley and providing and fixing a new main pulley/traction sheave of suitable diameter, groove profile, material and load-bearing capacity, compatible with the existing lift machine, motor, and wire rope arrangement. The main pulley/traction sheave shall be suitable for lifts of the following capacities: 08-passenger lift (544 kg), 13-passenger lift (884 kg) and goods lift (2000 kg), as applicable. The work shall include all necessary fixing, alignment, rope arrangement, balancing, adjustments and testing to ensure smooth, safe and satisfactory operation of the lift, complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 11 | Overhauling Complete lift machine hoist way and indication motor with any capacity both by opening of Gear removing old dirty oil, cleaning & replacing of new gear oil refitting of the same with new packing & adjustment of thrust bearing and keeping it into perfect working order, opening of hosit way machine by taking the main pully and divereter pully and complete refixing after overhauling Complete all as specified and directed. |
| 12 | Dismantling and taking down the existing old/unserviceable pit pulley and governor pulley, including all associated accessories, from passenger lifts of 08-passenger (08 PS) and 13-passenger (13 PS) capacities and goods lifts supply and fixing of new pit pulleys and governor pulleys suitable for the existing lifts serving buildings up to G+14 floors and driven by motors of up to 15 HP capacity. The new pulleys shall conform to the existing diameter, dimensions and configuration and shall be compatible with the existing lift system as per the original equipment manufacturer's (OEM) specifications. The work shall include necessary mounting, fixing, alignment, adjustment, rope arrangement, testing and commissioning, complete all as specified and directed by the Engineer-in-Charge. |
| 13 | Supplying and fixing in repairs new buffer spring suitable for a 13-passenger (13 PS/884 kg) capacity lift, including all necessary fittings, supports and accessories, complete with installation, alignment, adjustment, testing and commissioning to ensure safe and satisfactory operation, all as specified and directed by the Engineer-in-Charge. |
| 14 | Supply and fixing of aluminium-covered, wire-wound Dynamic Braking Resistor (DBR) suitable for dissipating the regenerative energy generated by the lift motor during braking and control operations, compatible with the existing lift drive and control system. The DBR shall be suitable for lifts of the following capacities: 08-passenger lift (544 kg), 13-passenger lift (884 kg) and goods lift (2000 kg), as applicable. The work shall include all necessary mounting arrangements, connections and accessories for proper functioning, complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 15 | Supply and fixing in repairs new aluminium chequered plate of thickness not less than 5 mm, suitable size and design, including removal of existing glass plates wherever required, complete in all respects for existing lift as specified and directed by Engineer-in-Charge. |
| 16 | Supply, install, testing and commissioning in repairs of Lift Machine Room LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed, including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following-(a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer)(b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -02 Nos(c) RCBO 4 pole, 63 Amps, 300 mA, 415 volt -03 Nos(d) MCB SPN 10-32 Amps 10 KA - 04 Nos (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos(f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.(g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.(h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four) (j) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. |
| 17 | Material & Labour for repairs/ Servicing to Existing panels Indoor type of Machine room of various bldgs by taking shut down from appropiate authority including checking loose connections and cleaning inside/out side all connection, replacing old/rusted cable glands,thimbles and lugs as per the size of existing cable, repair to broken /hanging doors, glas and cover bolts etc to make it servicable and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. Note :- The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt MCB SPN/MCCB/Voltmeter/ Ampiermeter/LED lamps of any type and discription etc and refixing the same, which shall be measured and paid as supply only vide relivent items of this schedule.(i) Cleaning inside the panel and all incoming and out going including MCCB/MCB SPN thorouly with help of Vaccum Cleaner.(ii) Checking the loose connections of incoming and out going cable/wire and rectifify the same. |
| 18 | Supply, Fixing, testing and commissioning of 35 sqmm, 3.5 core XLPE insulated armoured, heavy duty electric cable with aluminium conductor laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable of following sizes:- |
| 19 | M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 50mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 20 | M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected to lifts including PCC earth pit with cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate including testing on completion complete all as specified and directed. |
| 21 | Supply and fixing in repairs of 63 A, four-pole (FP), Moulded case circuit breaker (MCCB), rated 16 kA breaking capacity, 50 Hz, with thermal-magnetic release and service breaking capacity (Ics) equal to ultimate breaking capacity (Icu), in the existing feeder pillar/panel, including connection to the existing busbar with all necessary connecting accessories and modification of the busbar, if required, complete with connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge |
| 22 | Supply and fixing in repairs of 100 A, four-pole (FP), moulded case circuit breaker (MCCB), rated 16 kA breaking capacity, 50 Hz, with thermal-magnetic release and service breaking capacity (Ics) equal to ultimate breaking capacity (Icu), in the existing feeder pillar/panel, including connection to the existing busbar with all necessary connecting accessories and modification of the busbar, if required, complete with connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 23 | Supply and fixing in repairs of 160 A, four-pole (FP), moulded case circuit breaker (MCCB), rated 16 kA breaking capacity, 50 Hz, with thermal-magnetic release and service breaking capacity (Ics) equal to ultimate breaking capacity (Icu), in the existing feeder pillar/panel, including connection to the existing busbar with all necessary connecting accessories and modification of the busbar, if required, complete with connections, testing and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 24 | M&L scraping old worn out paint from complete indoor type meter cabin panels and painting with one coats of synthetic enamel paint (including door in front, door in side and indoor compartment where side etc also) over a coat of primer and spray painting complete including fixing sticker danger sign board suitable for LT panel board and replacement of broken glass of any size Complete all as specified and directed. |
| 25 | Supply and fixing in repairs of single-pole and neutral (SPN) miniature circuit breaker (MCB), rated 32 A, 10 kA breaking capacity, 230 V, complete with necessary connections, testing after installation and commissioning, all as specified and directed by the Engineer-in-Charge. |
| 26 | Disconnecting and taking out the existing old/unserviceable Car Operating Panel (COP) assembly of the lift installed in Building No. R-40 (G+13 storey building) and supplying and fixing a new Car Operating Panel assembly complete with illuminated floor selection push buttons, floor position indicator, alarm button, non-stop button, door-open and door-close buttons, cabin fan and cabin light switches, attendant key switch and other necessary controls, along with direction indicator, LED display and CPI card, provided with a stainless steel faceplate. The work shall include necessary wiring for all floor selection push buttons and control connections, integration with the existing lift control system, installation, testing and commissioning, including necessary making good of disturbed surfaces and all associated works, complete in all respects as specified and directed by the Engineer-in-Charge. |
| 27 | Supply and fixing in repairs of cabin fan, non-oscillating axial flow type, single speed, 300 mm sweep, 240 Volts, ISI marked, with aluminium powder coated grill, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and fixing in repairs of Infrared (IR) safety edge complete with power unit fitted on lift car door to safeguard passengers while entering and leaving the lift, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fixing in repairs of main steel wire rope of size 13 mm diameter, 8/19 construction, complete with necessary connections to counterweight pulley and car cabin, including clamps, bolts, washers, etc., conforming to IS:14865 (latest edition), complete all as specified and directed. |
| 30 | Supply and fixing in repairs of new steel wire governor rope of size 08 mm diameter, ungalvanised, 8/19 construction, including making proper connections in machine room and shaft pit with clamps, nuts, bolts, washers, etc., complete all as specified and directed. |
| 31 | Supply and fixing in repairs new overspeed governor (OSG) pulleys at both top and bottom positions in suitable for 08-passenger (08 PS/544 kg) and 13-passenger (13 PS/884 kg) capacity lifts, including all necessary fittings, alignment, adjustment and testing, complete all as specified and directed by the Engineer-in-Charge. |
| 32 | Supply and fixing of a new main traction sheave pulley with 3/5 grooves, suitable for the existing lift motor and compatible with the existing suspension ropes, including removal of the old/unserviceable pulley, refitting of existing ropes, alignment, adjustment and testing to ensure safe and satisfactory operation of the 08-passenger (08 PS/544 kg) and 13-passenger (13 PS/884 kg) capacity lifts, complete all as specified and directed by the Engineer-in-Charge. |
| 33 | Supply and fixing in commissioning and testing ARD system suitable for 15 KW motor including necessary wiring with connected items in existing G+13 Storey building suitable for 8Ps/13Ps lifts 415V, 50 Hz, 3 phase with a speed of 1.2 mtr/sec comprising of maintenance free battery 12 V, 04 Nos two year maintenance free battery to be compatible with the existing motor of any make and capacity and controller system complete all as specified and directed. |
| 34 | Dismantling and taking out unserviceable existing Stainless Steel landing door header (08 and 13 PS) from various floors with its header, lock, brake safety contact, etc & supply and fixing new stainless steel 18 SWG center opening with horizontal sliding stainless steel panel auto door for landing, Aluminium sill, bracket, bearing safety contact electro magnetic gate locks, hanger etc complete all as per existing size and design and masonry work and making good disturbed surface complete all as specified and directed. |
| 35 | Dismantling and taking out U/S car door (8 PS and 13 PS) from car cabin supply and fixing new car door comprises of 02 No power operated centre opening by horizontal sliding stainless steel panel of flush type panels complete with removed headers, hangers, door drive unit, aluminium sill VVVF door drive unit for motor complete with all accessories control connection etc. for lift complete all as specified and directed. |
| 36 | Supply and fixing in repairs of PVC-insulated, 16-core, flat/round-type lift travelling cable with multistranded copper conductors of 0.75 sq mm cross-sectional area, 1100 V grade, conforming to relevant IS standards, including provision of a suitable suspended arrangement to facilitate free and unobstructed movement of the lift car between the ground and uppermost floors. The work shall include necessary cable termination, connections through a midway junction box, circuit connections, fixing accessories, testing and commissioning, complete all as specified and directed by the Engineer-in-Charge. |
| 37 | Disconnecting and taking out defective shaft wiring and providing new shaft wiring in hoist way up to lower limit switch with PVC insulated 16/18 core flat/round type standard copper conductor cable size 1.00/0.75 Sqmm 1100 volts grade with ISI Marked drawing it up to ground floor in hoistway for control of all lift hoist assembly, limit switch, Fireman switch, etc complete all as specified and directed. |
| 38 | Dismantling and taking out unserviceable old control panel with control wiring up to mid way junction and supply and fixing new control panel with multiple integrated micro processor programmable chip based suitable for auto door, consisting of contactors, integrated mother board & compatible to existing capacity VVVF drive, connectors, assembled in MS Sheet cabinet with lockable hinge door, foot mounted, in powder coated finish, separate box for breaking resistor and programmed in such a way to operate lift from COP and comprising with variable voltage, variable frequency drive suitable up to 15 HP motor 240 volts 50Hz controlled by pulse with modulation complete with all safety devices such as over current protection, single phase protection etc. including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with 6.0 sq mm copper conductor in PVC insulated, IS Marked etc. including all standard features & fixtures etc all as per IS 14665 complete all as specified and directed. |
| 39 | Overhauling of complete lift hoisting machine, including hoistway and indication motors of any capacity, by dismantling the gear assembly, draining and removing old and contaminated gear oil, thoroughly cleaning the gear housing and components, refilling with fresh gear oil of the recommended grade, providing and replacing new gaskets/packings, adjusting the thrust bearings, and refitting the assembly to ensure smooth and efficient operation. The work shall also include dismantling the hoisting machine by removing the main pulley and diverter pulley, carrying out thorough cleaning, inspection and overhauling of all components, and refitting and aligning the same in their original positions. The entire system shall be tested and adjusted to ensure proper functioning and shall be left in perfect working order,complete all as specified and directed by the Engineer-in-Charge. Total in Figures 0.0 23 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender