Tender for special Repair To Bldg No. At-36 And At-37 Storage Accn Of annual rate contract Cantt Under Ge Shillong

BOQ

Name of Work:- SPL REPAIR TO BLDG NO. AT-36 AND AT-37 STORAGE ACCN OF ARC CANTT UNDER GE SHILLONG
Sl. No. Item Description
1S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
2S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
3S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and directed.
4S & F of 2nd class hard wood scantling, clean sawn in any position and any description as in unframed work including dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
5M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid / inserted to timber/GI/Aluminium framework with nails as in ceiling including dismantling wall and ceilling boards of any description including cover fillets complete all as specified and directed.
6M&L for Anodised aluminium snap grid frame work for false ceiling complete all as specified and directed.
7M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
8Demolition of Precast cement concrete block walling in any position, complete all as specified and directed.
9M/L precast cement concrete block massonry with solid blocks exc 10 cm in width and settings in CM 1:6 using cement concrete 1:3:6 Mix, Type C1 (Using 20 mm graded crushed stone aggregate) complete all as specified and directed.
10Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land complete all specified and directed.
11M&L for rendering on Brick /concrete surfaces of wall in two layers, first 10 mm thick cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 as finishing coat, finishing coat shall be mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed.Note:- WPC shall be measured & Paid separately
12M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces of wall complete all as specified and directed.
13Supply only integral water proofing compound (Powder) complete all as specified and directed.
14M&L for complete removal of existing treatment from existing plastered / unplastered surfaces of wall and applying 1mm thick of Birla white wall care putty (exterior grade) to achieve smooth surfaces and then applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over complete all as specified and directed
15M&L for preparation of new plaster external surface of wall and applying applying 1mm thick of Birla white wall care putty (exterior grade) to achieve smooth surfaces and the applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm overcomplete all as specified and directed.
16M & L for preparation of old plastered / concrete surfaces of walls, providing 1 mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and directed.
17M & L for preparation of new plastered/concrete surfaces of walls, providing 1 mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade / tint over a coat of compatiable priming paint complete all as specified and directed.
18M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
19M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
20Demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and directed.
21M&L for Hard core, broken stone /boulders to gauge n exc 63 mm size , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
22M&L for 75 mm thick PCC 1:3:6 Mix, type C2 (using 20mm graded crushed stone agg) as in plinth protection/path incl finishing even & smooth without using extra cement complete all as specified and directed.
23M&L for PCC 1:3:6 Mix, type C2 (using 20mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.
24M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
25M&L for 25mm thick PCC, 1:2:4 Mix, type B-0 (Using 12.5 mm graded crushed stone aggregate) as in levelling coarse of tile flooring etc complete all as specified and directed.
26Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc complete all as specified and directed.
27M& L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
28M& L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
29M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including 15mm thick screed bed in cement mortar 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
30M&L for Pre cast RCC 1:2:4 Mix, type B1 (using 20 mm graded crushed stone aggregates) as in cover slab for soakage well / manhole and similar workssupported on walls set in cement mortar 1:6 including necessary form work complete all as specified and directed.Note:- Reinforcement steel shall be measured & paid separately.
31M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
32S&F PVC gutter , Half Round, 180mm size complete all as specified and directed.
33S&F Joint Bracket (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed.
34S&F Support Bracket, 180mm for PVC pipes (half round) complete all as specified and directed.
35S&F Running Outlet (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed.
36S&F Stop End Outlet (with 1 clamp), 180mm for PVC pipes (half round) complete all as specified and directed.
37S&F PVC Reducer, 180mmx110mm complete all as specified and directed.
38S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
39S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified and directed.
40Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
41Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
42Resecuring or easing & adjusting without taking down the shutter of any description exc 1 Sqm and n.exc 2 Sqm in same opening complete all as specified and directed.
43S&F MS flat iron such as small articles for hold fast and similar work all as specified and directed.
44M&L PCC 1:2:4 Mix, type B1 (Using 20mm graded crushed stone Aggregate) for fixing hold fast complete all as specified and directed.
45Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
46Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
47Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkhats complete all as specified and directed.
48S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and directed
49S&F powder coated(powder coating min 50 micron) anodised window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete as specified and directed
50S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete all as specified and directed.
51M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
52Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed.
53Supply and fixing 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
54Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
55Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed.
56S & F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
57S & F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all a specified and directed.
58S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
59M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and directed.
60M&L for Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed.
61Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and dircted.
62S&F MS frame work such as grills grating etc, with ends of bar shouldered and or riveled, or forged into spickes framed quared bars and similar work all as specified and directed.
63Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
64M&L for cement concrete 1:3:6 Mix, type C-2, using 40 mm graded crushed stone aggregate), as in foundation all as specified and directed.
65S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
66M&L for preparation of new painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide Primer complete all as specified and directed.
67M&L for 40mm thick PCC 1:2:4 Mix, type B-1 (Using 20 mm graded crushed stone aggregate) as in any type of flooring etc finishing the surface even and smooth using extra cement complete all as specified and directed.
68S&F Glass dividing strips, 3 mm thick and width of strip 38mm all as specified and directed.
69M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as Specified and Directed.
70S&F Precast Cement Designer jali (Jafri Pattern) of minimum thickness 50 mm for Partition,Opening,Ventilation etc including complete fixing, as per site requirement complete all as specified and directed.
71Demolition of RCC (reinforcement cut as required to facilitate demolition) ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
72M & L for Reinforceed cement concrete (Nominal Mix) 1:2:4 Mix, Type B1 (Using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
73M&L for Form work to soffits of suspended slab such as roof slabs, floor slabs landing and similar work not exc. 200mm thick (Horizontal or Sloping) complete all as specified and directed.
74Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified.
75Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm casing caping PVC on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including accessories including making good the disturbed surfaces as per existing for one light point controlled by one, one way switch complete all as specified and directed.
76All as per item No. 75 above but One 3 pin 5 Amps socket out let points on independent board
77All as per item No. 75 above but 5 Amp socket on same board with other switches.
78Material and labour point wiring for power point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm width or higher size PVC casing caping and fittings of medium grade fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
79Supply and fixing submain wiring for DBs/ Power Point, two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing caping (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.Note: two runs of main wire, one run of earth wire and one run of Casing Caping shall be measured as one unit.
80Supply & fix ceiling rose surface bakelite 65 mm x 50 mm three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
81Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed.
82Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed.
83Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and directed. (For Same Board only)
84Supply and fix switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified and directed.
85Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded aluminium housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
86Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
87Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessary connection complete all as specified and directed.
88Supply and fix MCB SPN 40 - 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection all as complete all as specified and directed.
89Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I including necessary testing on completion complete all as specified and directed.
90Note for all items: If in BOQ, any item found repeated and contractor quotes different rates for the same, the lesser rate quoted by the contractor shall be admissible for payment and no claim of contractor, whatsoever, on this account shall be entertained by the Department. NOTE FOR ALL ITEMSIn case in BOQ any item found repeated and contractor quotes different rate for the same, the rate quoted on lesser side shall only be applicable for payment and no claim whatsoever on this account shall be entertained by the Department. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58579502
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.14 Lakhs
LAST DATE 08-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Bldg No. At-36 And At-37 Storage Accn Of annual rate contract Cantt Under Ge Shillong
Basic Detail
Tender No GE/SHL/TOKEN-104 OF 2026-27
Bidding Type Tender
Location
City East Khasi Hills
State Meghalaya
Key Dates
Publish Date 17 Nov 2026
Submission Date 08 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value 40.14 Lakhs
Tender Fee 500
EMD 80280
Exemption Available
Document List
BOQ_896634.xls
f248e998-2093-4d89-9f79-25e0b357229a.html
TENDERDOCU104.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_896634.xls

html

f248e998-2093-4d89-9f79-25e0b357229a.html

pdf

TENDERDOCU104.pdf

pdf

Tendernotice_1.pdf

Disclaimer