Tender For Comprehensive Maintenance, Repair/Replacement Of Ht Network, Vcb, Transformers, Dehydration Including Caliberation Of Relays, Other Connected Ht Equipment And Allied Works Under Age(I) Suranussi.
Tender Value
44.20 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
18 days left
EMD
88400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Maintenance, Repair/Replacement Of Ht Network, Vcb, Transformers, Dehydration Including Caliberation Of Relays, Other Connected Ht Equipment And Allied Works Under Age(I) Suranussi.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 m in depth for laying of cables including taking out old PCC cover/bricks and stacking for re-use and getting out soil, complete, all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.50 m wide but exc 1.50 m and not exc 3.0 m in depth and getting out in soft/loose soil for laying of pipes/cables etc complete all as specified and as directed. |
| 3 | Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed. |
| 4 | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete, all as specified and directed. |
| 5 | Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches and punned down to thickness of 18cm complete all as specified. Note: The punned down thickness of 18 cm shall be measured & paid. |
| 6 | Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm laid in trenches as cable covers complete all as specified & directed. |
| 7 | M&L for providing PCC 1:4:8 type D-2 mix using 40mm graded stone aggregate as in foundation of poles/struts etc including necessary form work as required at site complete all as specified and directed. |
| 8 | Supply and fix galvanised pipe light grade of IS marked 100 mm bore for passing of cable fixed to poles/walls/laid under floor/road complete with and including fittings as required including taking out unserviceable pipe complete all as specified and directed. |
| 9 | All as per item No 8 above but of size 80 mm bore. |
| 10 | Supply, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade earthed system of size 95 Sqmm 3 core conforming to IS-7098 (Part-II) 1985 laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed. |
| 11 | M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm equipment and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate with 1 nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. |
| 12 | S & F in repair 25 mm x 3 mm aluminum strip as earth continuity conductor including from test point to equipement complete all as speicified & directed. |
| 13 | Supply & Fix 40mm dia gun metal gate valves with iron wheel head screwed at both ends for drain out transformer oil complete including dismantling of old unserviceable gate valve from existing transformer at any location complete all as specified and as directed. |
| 14 | Dismantling the UNSV sign board in installations and supply and fixing retro reflector board of size 4ft x3 ft with high quality retro reflector tape blue base high intensity prismatic sheeting (HIP) grade white retro tape cutting good quality with 3mm thick ACP sheet base including 40mm x 40mm square size MS pipe duly painted all around the board appx 14 feet incl welding the MS flat plate of size 25mm x 3mm across the board and 40mm square size MS pipe legs to make overall board height of 10 ft including grouting the sign board in PCC 1:2:4 complete all as specified and directed.Note: Details/description of printing words will be provided by department. |
| 15 | M&L for prestressed concrete pole 11 metre long, 152mm x 152mm at top and 152 mm x 260mm at bottom class 9 complete including painting with one coat of aluminium paint to all PCC poles structure such as channel/brackets, bracing, clamps, anti climbing device, cross arms and further painting 30 cm high alternate yellow & black strips with synthetic enamelled paint upto 1.5 m height and mentioned the FEEDER NAME with red synthetic enamel paint on each HT structure, complete, all as specified and directed. |
| 16 | Supply, installation, testing and commissioning of dry type resin cast current transformer (CT) having ratio 100-50/5-1 A, burden 2.5 VA, class 1, STC 21 KA for 3 sec of size and shape as per existing suitable for VCBs complete all as specified and directed. |
| 17 | Supply, installation, testing and commissioning of Dry type Resin cast current transformer (CT) having ratio 200-100/5-1 A, burden 1 VA, 5P10, STC 21 KA for 3 sec of size and shape as per existing suitable for VCBs complete all as specified and directed. |
| 18 | M & L for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE HT/LT underground power cables of the rating 11 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of faut location necessary excavation and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar cantt all as specified and directed. Note: The joint shall be measured and paid separately under relevant item. The qty of item will be executed at different times during currency of contract as directed. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly.if Contractor shall have to bear a penalty a sum of Rs 4000.00/day will be recovered in case of not attend break down by service Engineer and not rectified defect with in 24 Hrs. |
| 19 | M &L for Servicing of vaccum circuit breaker 11 KV by taking shut down and disconnecting electrical connections, removing of dust with blower, cleaning of all movable/ immovable parts, checking all components, close/ trip coil operation, insulators/ studs with megger and replacing unserviceable parts, adjusting the male / female bushings in proper spacing, greasing all parts, tightening nuts and bolts,including CT, PT and relay in control panel of VCB of capacity 630 amp and reconnecting all electrical connections, testing of VCB complete all as directed by Engineer-in-charge as details mentioned as under and submitting written test report for testing complete:-(a) Details of servicing of breaker :-(i) Adjustment of mechanism if required.(ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth.(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.(iv) Check for rust and wear.(v) Check Spring Tension and pitting of the Cluster Contacts.(vi) Visual check for rust and deformation.(vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.(viii) Check for loosened connections, rust, damaged lead wires.(ix) Check whether the contacts are damaged by arcing.(x) Checking of control circuit & tighten the connections if any.(xi) Check close & trip coil.(xii) Checking of Jaw Contacts Conditions and repair/adjust.(xiii) Replace the jaw contacts,If required.(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.(xv) Replacement of Dashpot/shock absorbers .(xvi) Replacement of carbon brush of spring charging motor Note: The entire servicing inspection shall be carried out qualified staff. The Spares replaced shall be measured and paid. seperately. |
| 20 | M&L for replacement of Master trip relay 24V/110V/220V DC suitable for existing 11KV VCB complete. |
| 21 | Taking down old broken HT PCC poles carefully and including breaking of PCC making good the disturbed surface |
| 22 | M&L for HT jumper cable made of XLPE insulated aluminium conductor of length 2 metre long with crimped thimbles at both ends complete fixing on 2 pole/ 4 pole structure of size 95 sqmm |
| 23 | Dehydration and filteration of existing transformer oil at site of installation for using transformer oil filteration plant/ machine to eliminate moisture and foreign particles till improved di-electric strength of oil upto 11 KV (minimum) at a 2.5 mm electrode gap retrieved and to bring the acidity within the permissible limit below 0.5 mg KOH/Cm all as specified and directed. |
| 24 | Supply and filling of transformer oil in sealed containers having di-electric strength 65 (minimum) at a electrode gap of 2.5 mm upto the required level of transformer and testing of di-electric strength of oil in transformer before and after filling. (Transformer oil to be supplied in sealed container). |
| 25 | Supply & fixing silica gel breather assembly for transformer of capacity 50 KVA up to 160 KVA with silica gel capacity 500 gram filled complete all as specified & directed. |
| 26 | Supply & fixing silica gel breather assembly for transformer of capacity abve 160 KVA to 250 KVA with silica gel capacity 1 Kg filled complete all as specified & directed. |
| 27 | Supply and filling of fresh and dry silica gel 6 to 8 mm size inside the breather pocket and fixing properly with transformer, complecte all as specified and directed. |
| 28 | M & L for detecting leakage from transformer complete by removing HT & LT supply connections, decanning oil for reuse, opening top cover, of capacity 63 to 100 KVA removing leakge, and fixing top cover including re-filling oil, making necessary electric connections and testing complete on site in existing location (at plinth pole structure) complete.Note : (i) The items replaced shall be measured the said work shall be carried out at site. if contractor shift/transport the same to workshop for repair due to non-availability of labour, nothing extra, shall be paid on account of this hence contractor shall quoate his rate accordingly. |
| 29 | Supply and fixing in repair top cover cork gasket sheet 6 mm thick min. |
| 30 | Supply and fixing in repair LT stud brass with nuts and washer. |
| 31 | Supply and fixing in repair LT bushing rod gasket and oil seals. |
| 32 | Supply and fixing in repair HT stud brass rod with nuts and washer. |
| 33 | Supply and fixing in repair HT bushing gasket and oil seals. |
| 34 | M & L for detecting leakage from transformer complete by removing HT & LT supply connections, decanning oil for reuse, opening top cover, of capacity 160 to 250 KVA removing leakge, and fixing top cover including re-filling oil, making necessary electric connections and testing complete on site in existing location (at plinth pole structure) complete.Note : (i) The items replaced shall be measured the said work shall be carried out at site. if contractor shift/transport the same to workshop for repair due to non-availability of labour, nothing extra, shall be paid on account of this hence contractor shall quoate his rate accordingly. |
| 35 | Supply and fixing in repair top cover cork gasket sheet 6mm thick minimum, all as directed. |
| 36 | Supply and fixing in repair LT stud brass rod with nuts and washer, all as directed. |
| 37 | Supply and fixing in repair LT bushing gasket and oil seals, all as directed. |
| 38 | Supply and fixing in repair HT stud brass rod with nuts and washer, all as directed. |
| 39 | Supply and fixing in repair HT bushing gasket and oil seals, all as directed. |
| 40 | S & F aluminium P G Clamp of transformer of 11/0.433 KV of size 4 to 6 inch complete all as specified and directed. |
| 41 | M&L for power pack with capacitor back up suitable for VCB 11KV 630/800 Amp working on 110V/230V Ac and output 24V DC, capacity 100 watt complete all as specified and directed. |
| 42 | Material and labour for Digital voltmeter 0-15KV, PTR 11KV/110V, CL 1.0 complete with necessary connections and replacement of internal wiring incl removing old unserviceable all as directed. |
| 43 | Material and labour for Digital ammeter 96x96mm suitable to work on Cl 1.0 having CT ratio as per existing ammeter complete with necessary connections and replacement of internal wiring incl removing old unserviceable all as directed. |
| 44 | Supply & fix in replacement Tripping coil assembly 110 AC/24V DC, suitable for VCB 400/630 Amps.. |
| 45 | Supply & fix in replacement Vaccum interrupter 2.4 inch VL 35409 M3 suitable for 630 A VMX breaker. |
| 46 | Supply & fix in replacement Vaccum interrupter type EL-34599 CL (3 inch dia) suitable for VCB 630 Amps 11 KV all as specified and directed. |
| 47 | Testing of VCB 11 KV protection (overload and earth fault) relays through current injection system including current setting and time setting as per site requirement at 11 KV Sub Stn at different location complete all as directed by Engr-in-Charge.(b) The following test shall be carried out:-(i) Injection Test/ ratio test of CT / PT(ii) IR Test with megger in open and closed condition.(iii) Closing coil resistance(iv) Tripping coil resistance.(c) Testing and calibration of following relays of control panel with Suitable Injection Kit ,checking and programming of relay :-(i) Over current and earth fault relay(d) Testing of followig Aux relay(i) DC Supply supervision relay.(ii) Master trip relayNote : Contractor shall submit complete report to Engr-in-Charge before payment. |
| 48 | Supply & fix in replacement Push button switch for 11 KV VCB panel, spring return type, suitable for open/close operation, heavy duty industrial type with required NO/NC contacts, suitable for existing control circuit, complete all as specified. |
| 49 | Supply & fix in replacement Electronic Hooter for 11 KV VCB panel, suitable for panel alarm/annunciation system operation, suitable for existing control voltage, high sound output, complete with mounting arrangement and required accessories, all as specified and directed. |
| 50 | M&L for replacing DC supply of copper wiring of size 2.5 Sqmm with 2 run for VCB complete for detecting fault in DC supply and replacing with new one upto 30 Mtr length complete all as specified and directed. |
| 51 | Supply & replacement of defective tap changer switch assembly complete with tapping arrangement suitable to steping up/ down of 2.5% voltage normal tapping suitable for transformer 11 KV/ 433 volts, 3 phase of capacity including making connections and testing commissioning 63 to 160 KVA complete all as specified & directed. |
| 52 | Supply & replacement of defective tap changer switch assembly complete with tapping arrangement suitable to steping up/ down of 2.5% voltage normal tapping suitable for transformer 11 KV/ 433 volts, 3 phase of capacity including making connections and testing commissioning 200-250 KVA complete all as specified & directed. |
| 53 | Material and labour for rewinding of burnt/ over heated HT/ LT limbs of transformers 11 KV/ 433 volts, 3 phase of capacity 63 up to 160 KVA by using double paper covered (DPC) proper insulated superior quality copper conductor wire of suitable gauge, size and specification complete all as specified. |
| 54 | Material and labour for rewinding of burnt/ over heated HT/ LT limbs of transformers 11 KV/ 433 volts, 3 phase of capacity above 160 to 250 KVA by using double paper covered (DPC) proper insulated superior quality copper conductor wire of suitable gauge, size and specification complete all as specified. |
| 55 | Material and labour for rewinding of burnt/ over heated HT/ LT limbs of transformers 11 KV/ 433 volts, 3 phase of capacity 63 to 250 KVA by using double paper covered (DPC) proper insulated superior quality aluminium conductor wire of suitable gauge, size and specification complete all as specified. |
| 56 | Supply and fixing transformer oil temperature gauge 0 - 100 graduated with double needle. Analogue dial type(adjustable), suitable for transformer of capacity 63 KVA to 250 KVA suitable as per existing make and type complete all as specified & directed. Please Enable Macros to View BoQ information |
| 57 | Supply and fixing transformer oil temperature gauge 0 - 100 graduated with double needle. Analogue dial type(adjustable), suitable for transformer of capacity 63 KVA to 250 KVA suitable as per existing make and type complete all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender