Tender For Provision Of Deficient Visitors Room At Ctw (K), Naval Base, Kochi And Provision Of Deficient Bicycle Stand For Building No. P-177 (Dsc Personnel Single Living Accommodation) At installation Garuda, Naval Base, Kochi And Special Repairs To
Tender Overview
Project Description
Tender for Provision Of Deficient Visitors Room At Ctw (K), Naval Base, Kochi And Provision Of Deficient Bicycle Stand For Building No. P-177 (Dsc Personnel Single Living Accommodation) At installation Garuda, Naval Base, Kochi And Special Repairs To Earthing Pits And Lightning Arrestors Of Hull Fabrication Shop (P-14), Integrated Machine Shop (P-23), Auxiliary Fitting Shop (P-24), Electrical Shop (P-25), Ice Shop (P-28), Slipway Shed (P-34) And Administrative Building (P-40) Of Nsry (Koc) Under Ge (Nw) Kochi
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness complete in roofing complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 3 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed. |
| 4 | Excavation in trenches n.exc 1.5m and n.exc 1.5m in depth for foundation and getting out in soft/ loose soil complete all as specified and directed. |
| 5 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 6 | Removing excavated material beyond 50 m and upto a total distance of 250 m complete all as specified and directed. |
| 7 | Removing excavated soil exc.250m but n.exc 500m and depositing where directed by Engineer-in -Charge. |
| 8 | Returning filling in soft/loose soil including spreading leveling watering and wall ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 9 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 10 | M&L for hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 11 | M&L for PCC 1:4:8, type D2 as in foundation concrete using 40 mm graded stone aggregates complete all as specified and directed. |
| 12 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 13 | M&L for RCC 1:1.5:3 (Nominal mix) using 20mm graded 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 14 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished square, rectangular, or polygonal surfaces of concrete complete all as specified and directed. |
| 15 | M&L for RCC 1:1.5:3 (Nominal mix) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 16 | M&L for RCC 1:1.5:3 (Nominal mix) using 20mm graded crushed stone aggregate as in lintel beam/copings incl necessary formwork complete all as specified and directed. |
| 17 | M&L for precast cement concrete block masonry in type C1, 1:3:6 (20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in foundation load bearing wall and wall complete all as specified and directed. |
| 18 | M&l for rendering 8mm thick in CM 1:4 using liquid WPC over 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be paid separately. |
| 19 | Supply only liquid water proofing compound complete all as specified and directed by Engineer-In-Charge. |
| 20 | M&L for 10mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified and directed. |
| 21 | M&L for preparation of newly plastered external surfaces for preparation of surfaces and applying two coats of weather proof antifungal paint over a coat of exterior antifungal primer complete all as specified and as directed by the Engineer-in-Charge.Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction. |
| 22 | M&L for two coats of oil bound distemper over a coat of 1.5mm thick wall care putty and one coat of alkali resistant primer to newly plastered surface including preparation of surfaces complete all as specified and directed by Engineer-In-Charge. |
| 23 | M&L for formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed by Engineer-In-Charge. |
| 24 | M&L for RCC (Nominal mix ) type B1 1:2:4 (20MM graded aggregate ) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed by Engineer-In-Charge. |
| 25 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 26 | All as per item No 25 here-in-before, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F sandwitch PUF panel with PPGL sheet on both the surfaces with core material 0.4 & internal steel thickness 0.35mm sandwiched between the two steel wall facing 30mm thick, the density of core material is 38 kg/cum (+or - 2) manufactured in continous line to match the height of 38mm and distance between two crest should be 333.3 mm. PUF galmet 30mm including ridges. NOTE; Necessary precautions to be taken to avoid any damage to ceiling and in any case of any damages to existing ceiling, it shall be rectified by the contractor at his own risk and cost complete all as specified and directed. |
| 28 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. |
| 29 | S&F roof trusses (framed or tubular sections) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular pipes or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 30 | S&F 200mm dia of half round or 220mm width rectangular UPVC heavy duty eaves gutter of pressure rating 6 kg/cm2 of approved make with all necessary fittings, clamp, joints, end cap, corner drop, centre drop, etc joining compounds, nut, bolts or screws etc and fixing in position, at any height complete all as specified and as directed. |
| 31 | S&F 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 32 | S&F PVC (SWR) bends, any radius, 110mm bore all as specified,complete all as specified and as directed. |
| 33 | S&F aluminum snap grid false ceiling with grid 605x605mm size including hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40 x 3 mm size 60 mm long & expansion hold fastners 12.5 mm dia 40 mm long (JINDAL/INDAL/HINDALCO) includng 6mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with stainless steel screws complete all as specified and directed. |
| 34 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive epoxy paint over a coat of epoxy primer, over a coat of red oxide on steel surfaces complete all as specified and directed. |
| 35 | M&L for 50 mm thick PCC 1:4:8, Type D-2 using 40 mm graded stone aggregate complete all as specified and directed. |
| 36 | M&L for 50 mm thick PCC 1:2:4, Type B-2 using 40 mm graded stone aggregate complete all as specified and directed. |
| 37 | M&L for light shade vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exc 0.42 Sqm but not exc 1 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 laying floor finishes, complete all as specified and directed. |
| 38 | M&L for vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exc 0.42 Sqm but not exc 1 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 5mm thick screed bed of cement mortar 1:3 as in skirtings floor finishes, complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F aluminum powder coated three track sliding windows with three sliding shutters with glass panes and stainless steel jalli including suitable beading channel gasket, rollers Maruthi lock with handles etc complete with following specification:-Frame :- 92.36mmx29.70mmx2.00mmShutter stiles, top & bottom :- 39x20X1.5mmPanel :- 5mm thick tinted/plain sheet glass of selected quality exc 0.50Sqm each pane fixed to aluminum frame with beading, rubber gasket etc. Mosquito proof jalli: Stainless steel jalli 0.45mm nominal dia of wire and average width of aperture 1.40mm fixed type with appropriate size powder coated aluminium section on external faces of window. |
| 40 | S&F aluminum powder coated door shutter with frames of size - 44.5mmx50mmx1.5 mm incl. screwing of frame glass necessary joints cleats, glazing clips rubber packing, snap beading, suitable handle, tower bolt, SS butt hinges,mortice lock 4 lever with 65 mm latch size including aluminium anodized door frame of size 63.5mmx 38.10mm x1.5 mm thick fixed to wall with necessary screws and plug complete all as specified & directed. (Note: Rates for one no hydraulic door closer per shutter & 5 mm thick tinted glass /4mm thick ACP sheet reqd to be fitted in shutters is included in the item ) |
| 41 | M&L for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soif /loose soil complete all as specified and directed. |
| 42 | Excavation in post holes (or similar holes) each n.exe 0.5 cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm watering in soft/loose soil complete all as specified and directed. |
| 43 | M&L for cement concrete in post holes foundation fillings and mass concreting PCC 1:3:6 Type C2 (using 40mm graded stone aggregate) complete all as specified and as directed. |
| 44 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming tofe -410W (gd E-250) quality A complete all as specified and as directed. |
| 45 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet MP Tile pattern, 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 46 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 47 | M&L for 100mm thick cement concrete type D2, 1:4:8 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed. |
| 48 | M&L for coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm spreading and levelling in layers complete all as specified and as directed by Engineer-in-Charge. |
| 49 | M&L for machine pressed precast conctete paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 graded with grey cement and pigment complete all as specified and as directed by Engineer-in-Charge. |
| 50 | M&L for PCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in mass concrete around the machine pressed precast conctete paver block or chamfered on edges all as specified and as directed by Engineer-in-Charge. |
| 51 | Material and labour for point wiring with approved colour coding as per IS, for one light with 1.5 sqmm PVC insulated (FRLSH) sheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated sheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit 20 mm dia medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed. |
| 52 | All as per item No.51 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed. |
| 53 | All as per item No.51 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed. |
| 54 | All as per item No.51 here in before but using with 2.5 Sqmm copper conductor multistranded (FRLSH) PVC insulated, sheathed cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and sheathed cable as earth continity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed. |
| 55 | S&F Modular Switch 6 Amps 240 Volts one way switch complete all as specified and directed. |
| 56 | S&F Modular Switch 16 amps AC 240 volts one way complete all as specified and directed. |
| 57 | S&F Modular Socket 6 Amps AC 240 Volts 3/5 pin combined 2 module type complete all as specified and directed. |
| 58 | S&F Modular Socket 6A/16 Amps- 3/5 pin combined AC 240 Volts 2 module complete all as specified and directed. |
| 59 | S&F Modular fan Regulator, electronic rotary, stepped type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed. |
| 60 | S&Fceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified and directed. |
| 61 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old unserviceable light fitting complete all as specified and directed. |
| 62 | S&F recess mounted square type commercial luminaire 15 watt ,50 Hz ,220 volts,5700 K LED down lighter 1'x1' , complete all as specified and directed. |
| 63 | S&F LED bldg security light fitting 35 Watt, 100 Lumen/ Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and directed. |
| 64 | S&F ceiling fans, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to ceiling fan max 1.5 mtr for giving connection complete all as specified and directed. |
| 65 | S&F sheet metal enclosure SPN DB when MCB's to be used 8 way with 200 amps bus bar double door, complete all as specified and as directed by Engineer-in-Charge.Make :Legrand Cat Part No. 5076 01 or any other equivallent make as per approved list of manufactures |
| 66 | S&F MCB SPN 32 AMP, 240 volts, \\"C\\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed. |
| 67 | S&F MCB SP, 6A-40 Amps, 240 volts, \\"C\\" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as specified and directed. |
| 68 | M&L for sub main wiring with four single core 2x6 Sqmm FRLS insulated and sheathed stranded copper conductor alongwith earth wire 6 Sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed. (Note: Four runs cable and one number earth wire and suitable FRLS conduit shall be measured together as unit length). |
| 69 | Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounted from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electorde connected by using GI wire 4 mm dia (max -length of 7.5 mtrs )by means of bolts,nut and washer of GI and providing GI light grade pipe 15 mm dia as prrotection pipe for GI wire connected main controll board / test point and provided with GI pipe of light grade 20 mm bore for watering and including funnel,wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil complete all as specified and as directed by Engineer-in-Charge and shown in electricall plate No. 3 of SSR part -1 including testing on completion. |
| 70 | S&F switch piano flush button single pole one way 5 Amps, complete all as specified and directed. |
| 71 | S&F sheet metal enclosures for DBs when MCBs to be used single pole & neutral (SPN) double door 240 volts, 4 way with IP-43 protection incl. 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed. |
| 72 | M&L for sub main wiring with two runs of 2.5 sqmm PVC insulated multi stranded FRLSH copper cable drawn through PVC concealed conduit of size not below 25mm size with all fixing accessories along with one run of 2.5 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire along with PVC conduit shall be measured as one length. |
| 73 | S&F in replacement of air termination vertical type single pointed aluminium rod made of 12 mm dia and 300 mm long with base plate welded at bottom complete all as specified and directed. |
| 74 | S&F aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 75 | S&F GI strip 32x6mm buried directly in ground or fixed to walls complete all as specified and directed. |
| 76 | S&F in replacement of test point terminal block made of gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw for fixing the same on wall, including suitable size of coverd MS box of 1.5mm thick complete all as specified and directed. |
| 77 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers all around top and bottom and electrode connection by using galvanised iron earth lead strip of size 32 x 6mm flat iron by means of bolts, nuts, check nut and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 40mm bore protection pipe light grade for protection strip upto 3m above ground level (Up to the test points) PCC chamber in cement concrete (1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion:-(a) The unit rate shall include for protection pipe, GI water pipe, funnel, wire mesh excavation & earth work, RCC pit cover, test point, 32x6mm galvanised strip from top of earth plate upto test point ( Maximum 7.5mtr length). (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc. shall be deemed to be included in the unit rate. (c) If the testing result of earth work is not been found satisfactory within the permissible limit, then the contractor shall do other earthing work at free of cost. (d) Earthing work shall be carried out in presence of MES representative. (e) Earth testing instrument such as earth tester shall be provided by the contractor and the rate for the same shall deemed to be included in the item rate. |
| 78 | Taking down carefully existing Aluminium strip / GI strip with saddles and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender