Tender For Repairs/Maint/Improvement Of Roof At Various Building In Op Area At 24 Ed Manauri
Tender Value
10 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/Maint/Improvement Of Roof At Various Building In Op Area At 24 Ed Manauri
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc and M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:6 complete finished even and smooth without using extra cement all as specified and directed. |
| 2 | M & L for preparation of new surfaces and applying 2 coats of OBD over a coat of primer all as specified and directed. |
| 3 | Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc and M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 complete finished even and smooth without using extra cement all as specified and directed.( wpc paid seprate) |
| 4 | Supply only integral water proofing compound |
| 5 | M & L for preparation of new surface of wall including cornices and apply two coat of cement based paint etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | M & L for PCC 1:3:6 type B-2, using 20 mm graded stone agg as in foundation, complete all as specified and directed. |
| 7 | M&L brick work with sub class \\"B\\" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge. |
| 8 | Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed. |
| 9 | M&L Rendering 15mm thick on fair faces of brick work, stone masonry or concrete surface, in cement mortar 1:4 finished the surface even and smooth without using extra cement , complete, all as specified |
| 10 | M&L for two coat of cement base paint over a coat of Alkali resistant primer to newly plastered surfaces of wall incl preparation of surface complete. |
| 11 | M&L Rendering 10mm thick on fair faces of brick work, stone masonry or concrete surface, in cement mortar 1:6 finished the surface even and smooth without using extra cement , complete, all as specified |
| 12 | M&L for prepration of new plaster surface of wall and applying three coat of white wash complete all as specified and directed. |
| 13 | M&L Rendering 10 mm thick on ceiling concrete surface, in cement mortar 1:3 finished the surface even and smooth without using extra cement complete all as specified |
| 14 | ditto all as above but in ceilling |
| 15 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 16 | Dismantling of AC (corrugated/semi corrugated) sheet/PGI/CGI in roof covering including ridges all as specified and directed by Eng-in-Charge. |
| 17 | M & L for 6mm thick Asbestos cement corrugated/semi corrugated sheet in roofs, fixed with L/J type hook or cranked hook bolt and making good to disturb surface etc complete all as specified and directed by Eng-in-Charge. |
| 18 | Refixing old dismantled 6mm thick Asbestos cement corrugated/semi corrugated sheet in roofs, fixed with L/J type hook or cranked hook bolt and making good to disturb surface etc complete all as specified and directed by Eng-in-Charge. |
| 19 | S&F AC Serrated ridge two pieces adjustable 6mm thick for corrugated or semi corrugated AC sheets fixed all as specified and directed by Eng-in-Charge. |
| 20 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, all as specified and directed. |
| 21 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/ridge/valley gutter in wall/roof, fixed with self tapping screws as specified |
| 22 | fixing old dismantled Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet any thickness and colour as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, all as specified and directed. |
| 23 | S & F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixedwith coach screw and washer in roof, wall etc of colour as approved by Engr-in-Charge in roof coverings incl ridges and fixed with necessary J/J hook, fasterners etc complete as specified & directed |
| 24 | Repair of holes in galvalume sheets/AC sheets by filling with bitumen washer, metal putty, silicon gel, M-Seal and similar solutions/chemicals to avoid leakage through the roof sheets all as specified and directed by engineer - in -charge. |
| 25 | M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. compete all as specefied and directed by E-in-Charge. (Fe- 410W Grade-E-250 quality A). |
| 26 | Dismantling wrought iron or mild steel work of any description allc as specefied. |
| 27 | M&L in applying two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed by the Engineer-in-Charge. |
| 28 | M & L for preparation of old steel surface exceeding 10 Cm width or girth and apply two coat of synthetic enamel paint complete all as specified & directed. |
| 29 | M & L for preparation of new wooden surface of any description over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed . |
| 30 | M & L for preparation of old wooden surface exceeding 10 cm width or girth and apply two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 31 | M/L 2nd class hard wood plain fillets square, rectangular or trangular in section , clean sawn se-cured with nails or brads area exc 3 and n.exc 13 sqcm .incl. Dismantling of timber in fillets, rails, posts, rafters, purlins, etc any position all as specified and directed. |
| 32 | Dismantling timber scantlings 40 sq. cm and over in section, in any position all as specified and directed. |
| 33 | M & L for Second class hard-wood in scantlings complete all as specified and directed by the Engineer-in-Charge. |
| 34 | M & L preparation of roof treatment with APP polymeric water proofing membrane all as given below :-(a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc and removing retrieved material to a distance n.exc 500m where directed.(b) M & L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including water proofing compound as per manufactures instructions and as directed by Engr-in-Charge.(c) Applying a coat of bituminous primer conforming to IS:3384-1986 @ 0.40 Ltrs/Sqm and allow to dry.(d) Applying and laying 3mm thick APP membrane having weight 3.2 – 3.5 Kg on prepared surface as per manufactures instructions and over laps 10cm and 15cm longitudinal and transverse directions respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into grooves on vertical plane and grove sealed with cement mortar 1 :3.(e) Applying two coats aluminium paint over membrane @ 0.20 Kg/Sqm and all as per specification and directed by Engr-in-Charge. |
| 35 | M&L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregates as in roof padding/coping etc all as specified and directed . |
| 36 | M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate , as in copping etc complete all as specified and directed by Engr-in-charge. |
| 37 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness, including cover fillets etc complete all as specified and directed. |
| 38 | S & F in repairs ceiling 4mm thick non abestos cement plain building boards, fixed to timber frame work with screws etc and including two coat of white wash, all complete as speceified. |
| 39 | S & F in repairs gypsum board 6/8 mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed.(except grids) |
| 40 | S & F in repairs gypsum board 6-8 mm thick in ceiling over and including anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm complete all as specified and as directed |
| 41 | M & L for preparation of ceiling surface and applying two coats of OBD over a coat of putty as required and as directed |
| 42 | M&L Slabs for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, desk slabs and in shelves Chajjas & the like1:2:4 type B1, using 20mm graded stone agg, complete all as specified by the Engineer-in-Charge. |
| 43 | Demolition of cement concrete (reinforced ) of any description and in any position compete all as specified and directed. |
| 44 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Rough finish |
| 45 | M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified by the Engineer-in-Charge. |
| 46 | M&L for Mild steel TMT bars 5mm dia and over and up to and incl 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips. Gde I IS 432 (part I) complete all as specified by the Engineer-in-Charge. |
| 47 | M & L preparation of roof treatment with APP polymeric water proofing membrane with roof tiles all as given below :-(a) Taking down existing water proofing treatment ,brick tiles and cleaning roof surface by washing and rubbing etc and removing retrieved material to a distance n.exc 500m where directed.(b) M & L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including water proofing compound as per manufactures instructions and as directed by Engr-in-Charge.(c) Applying a coat of bituminous primer conforming to IS:3384-1986 @ 0.40 Ltrs/Sqm and allow to dry.(d) Applying and laying 3mm thick APP membrane having weight 3.2 – 3.5 Kg on prepared surface as per manufactures instructions and over laps 10cm and 15cm longitudinal and transverse directions respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into grooves on vertical plane and grove sealed with cement mortar 1 :3.(e) Screed bed 15mm thick in CM 1:4 as in beddding layers using 100% coarse sand.(g) M & L for 20- 22mm thick cemented/ chequard plain roof tiles, set, jointed and pointed in neat cement slurry (1:3) as in terraces over screed bed all as specified and directed by Engr-in-Charge. |
| 48 | M & L non-skid ceramic coloured tiles joint free ceramic tiles 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors/skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:4 complete all as specified and directed ( incl. Dismantling floor, hearth or wall tilling including cement mortar bedding(but not backing), and rubbish off premises etc. |
| 49 | Dismantling water tanks of any capacity(500/1000 ltr) |
| 50 | S & F Rotational moulded polethelene water storage tanks 500 litres capasity (cylinderical vertical & triple layer with closed top) hoisted and fixed in position , ISI marked, all as specified and directed.(sintex, rhino, rotex, plasto, prayag) |
| 51 | S & F Rotational moulded polethelene water storage tanks in 1000 litres capasity (cylinderical vertical & triple layered with closed top) hoisted and fixed in position all as specified in SSR Pt-I complete, ISI marked, all as specified and directed. |
| 52 | Dismantling existing 500 Ltrs water tanks, setting aside, cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc and re-fixing in position all as directed and specified by Engr-in-Charge |
| 53 | Dismantling existing 1000 Ltrs water tanks, setting aside, cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc and re-fixing in position all as directed and specified by Engr-in-Charge |
| 54 | S&F in repair GI water tubing/pipe 15 mm bore with alll fittings fixed to wall or laid in floors or celings including taking out old rusted pipes in any position compete all as specified and directed |
| 55 | S&F in repair GI water tubing/pipe 20 mm bore with alll fittings fixed to wall or laid in floors or celings including taking out old rusted pipes in any position compete all as specified and directed. |
| 56 | S & F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms fly nut in 20mm bore complete all as specified. |
| 57 | S & F in repair 110mm dia PVC (SWR) pipes, single socketed in any length with MS clamps and fixed to wall complete all as specified and directed |
| 58 | S & F in repair 75mm dia PVC (SWR) pipes, single socketed in any length with MS clamps and fixed to wall complete all as specified and directed |
| 59 | S&F in repairs PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 60 | S&F in repairs 75mm PVC (SWR) bends any radius complete all as specified and directed. |
| 61 | S/F in repairs Pillar taps, 15mm bore CP with with capstan heads, long body screwed down, screwed for lron pipe high pressure with lettered \\"hot or Coled\\" with long shank compete all as specified and directed. |
| 62 | S/F in repairs Stop valves, 15mm bore cast copper alloy, fancy type CP screwed down high pressure screwed both ends for iron pipes or for unions compete all as specified and directed. |
| 63 | S/F in repairs chromium plated cast copper alloy bib taps 15 mm bore fancy type long body capstan head handles half turn compete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender