Tender For Repair / Maintenance To External Electrification Lt Network Including Ug Cables, Lt Panels And Allied Works At At Sgnr Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Dec 2026
19 days left
EMD
89820
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance To External Electrification Lt Network Including Ug Cables, Lt Panels And Allied Works At At Sgnr Mil Stn

BOQ

Name of Work:- REPAIR / MAINT TO EXTERNAL ELECTRIFICATION LT NETWORK INCLUDING UG CABLES, LT PANELS AND ALLIED WORKS AT AT SGNR MIL STN
Sl. No. Item Description
1Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m depth or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed.
2All as per sl item No. 1 above but depth exc 1.50 m but not exc 3.00 m complete all as specified and directed.
3Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
4Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
5Supply and Laying DWC pipe of size 120 mm OD/ 103.5 mm ID for cable protection complete all as specified and directed.
6Supply and Laying DWC pipe of size 50 mm OD/ 38 mm ID for cable protection complete all as specified and directed.
7Supply and Laying DWC pipe of size 75 mm OD/ 63 mm ID for cable protection complete all as specified and directed.
8M & L for boring hole under road,pavement , hard standing by trenchesless for laying DWC pipe upto 120mm dia suitable for outer dia of cable passing without damaging Road / Plinth /Floor complete all as specified and directed.
9Supplying, laying, jointing and testing and commissioning of 25 sq mm, 4 core PVC insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed.Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
10All as per Srl item No 8 here-in-before but cable of cross sectional area 10 Sqmm, 2 core complete all as specified and directed.
11All as per Srl item No 8 here-in-before but cable of cross sectional area 16 Sqmm, 4 core complete all as specified and directed.
12All as per Srl item No 8 here-in-before but cable of cross sectional area 35 Sqmm, 3.5 core complete all as specified and directed.
13All as per Srl item No 8 here-in-before but cable of cross sectional area 50 Sqmm, 3.5 core complete all as specified and directed.
14All as per Srl item No 8 here-in-before but cable of cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed.
15All as per Srl item No 8 here-in-before but cable of cross sectional area 95 Sqmm, 3.5 core complete all as specified and directed.
16All as per Srl item No 8 here-in-before but cable of cross sectional area 120 Sqmm, 3.5 core complete all as specified and directed.
17All as per Srl item No 8 here-in-before but cable of cross sectional area 150 Sqmm, 3.5 core complete all as specified and directed.
18All as per Srl item No 8 here-in-before but cable of cross sectional area 185 Sqmm, 3.5 core complete all as specified and directed.
19All as per Srl item No 8 here-in-before but cable of cross sectional area 240 Sqmm, 3.5 core complete all as specified and directed.Note for Sl item No 9 to 19 : Bricks/protection cover of LT cables shall be collected from excavation and credited to the contractor as per creit schedule..
20Supplying, laying, jointing and testing and commissioning of 6 sq mm, 3 core PVC insulated, screened, flat electric power cable heavy duty multi stranded copper conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 fixed on wall/hanging with suporting GI Wire including connecting with eqpt complete all as specified and directed.
21M&L for 190 cm dia cable route indicator made of CI plate 8 mm thick with spike to angle iron 25 x 25 x5mm, 40 cm long makred as LT/HT cable jointing on conductor coil plate complete including fixing and excavation in soft/loose/hard/dense soil, PVC embedded block size 300x300x300 mm (1:3:6) type C-1 using 20 mm graded stone aggreggate complete all as specified and directed.
22Supply and fix in repair cable jointing kit 1100 volt grade straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 25 to 50 sqmm,including testing complete all as specified and directed.
23All as per sl item No. 22 aboe but for cable of size 70 to 95 sqmm including testing complete all as specified and directed.
24All as per sl item No. 22 aboe but for cable of size 120 to 150 sqmm including testing complete all as specified and directed.
25All as per sl item No. 22 aboe but for cable of size 185 to 300 sqmm including testing complete all as specified and directed.
26M&L for Earthing in repairs complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth of not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia. by means of bolts, nuts and washers of the earth wire galvanized iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 40mm dia. up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Complete all as specified and directed.Notes: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
27M&L for Earthing in repairs complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanized iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanized iron pipe light grade 40mm dia. up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Complete all as specified and directed.Notes: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
28M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm galvanized iron strip complete all as specified and directed.
29S&F in repairs 9 meter long, type 410 SP- 31 steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts nuts and screws including painting with two coat of synthetic enamel paint black and white in alternate strips 30cm each up to 1.5 meter height from top of PCC coping and remaining portion of pole shall be painted with two coats of aluminum paint including writing pole No. with black synthetic enamel paint over 15 cm dia. yellow round base prepared with synthetic enamel paint complete all as specified and directed. NOTE: - Excavation, earth work and concrete work for embedding poles shall be measured and paid separately.
30S&F in repairs factory made 7 meter long hot dip galvanised octagonal pole with 130 mm dia including 1.5 mtr single Arm HDG OD-48.3 at bottom and 70 mm dia at top A/F made made up of 3mm thick HT sheet along with foundation type base plate of size 220x220x12mm foundation bolt 4nos of M20X750 high Jtype EN8 grade with inbuilt junction box suitable for incoming 3 phase LT cable 16 sqmm 4 core having 6A SP B class MCB fixed on bakelight sheetband stud type connector inside the pole ,the pole shall be adiquately strenthened at location of door to compensate for the loss in section including excavation and RCC/PCC (1:2:4) type B1 for foundation and grouting the bolt as per manufature instructions including marking pole numbers and figures of size radium tape not less than 10 cm hight with red colour enamel paint including taking out old U/S pole complete all as spacified and directed.
31M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and directed.
32M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in pedestal coping of poles etc including weathering, slightly rounded or chamfered angle and necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed.
33M&L for surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed.
34Dismantling insulators of any type and make including clamps from poles complete all as specified and directed.
35Dismantling and taking down cross arm of MS channel or angle section etc distance complete all as specified and directed.
36Dismantling and taking down ACSR conductor of any size complete all as specified and directed.
37Dismantling of stay assembly complete all as specified and directed.
38M & L for cutting road /plinth /hard standing for laying of pipe for passing cable through road / Plinth Floor including making good the same with ready mix material as per existing specifications complete all as specified and directed.
39S&F in repair street light timer switch i.e. nature switch which works on the basis of measurement of lux level of infra red rays along with enclosure box having dust and termite proof, outdoor type mounted on electric panel or on pole single phase with contactor, MCB rating 63 Amps with load bearing capacity of 5 KW complete all as specified and directed.
40S&F in repair street light timer switch i.e. nature switch which works on the basis of measurement of lux level of infra red rays along with enclosure box having dust and termite proof, outdoor type mounted on electric panel or on pole three phase with contactor, MCB rating 63 Amps with load bearing capacity of 12 KW complete all as specified and directed.
41Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines with hack saw/axe to clear the LT/HT line upto 3 metre on each side (Horizontal and / or vertical) including disposal of trimmed branches 2 KM away inside the cantonment area & clearing site complete all as specified and directed.Note :- 3 metre width on each side of LT/HT line shall be cleared and each span having not less than 3/5 conductors and min30-40 m pole to pole distance.
42M&L for taking out and relaying after rectification of existing LT cables of any size any type including disconnecting it and reconnecting using lugs cable and gland etc all as specified and directed.Note:- Excavation, earth work, and protective work shall be measured and paid separately under respective items
43S&F on pole / wall /in panel , Sheet metal enclosure Bus bar chamber consisting 4 pole 400 Amp 415 volts ,copper bus bar suitable for connecting cable as a junction including connecting of existing cables with suitable sizes aluminum thimbles and MCCB 4 Pole 400 Amp 415 , 36 KA complete all as specified and directed.
44All as per srl item No 43 but capacity 250 Amp 4 pole 415 volt 25 KA complete all as specified and directed.
45All as per srl item No 43 but capacity 200 Amp 4 pole 415 volt 25 KA complete all as specified and directed.
46All as per srl item No 43 but capacity 100 Amp 4 pole 415 volt 16 KA complete all as specified and directed.
47Supply and fix in replacement Hot moulded (FRP) junction box of size 155 mm x 210 mm x 92 mm for street light pole with locking arrangement with 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings with control MCB SP 25 Amps 01 Nos enclosed in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete with two number cable entry gland of standard size with suitable size mild steel clamps of size 25x3mm with nut and bolt to fix on pole complete all as specified and directed.
48S&F in replacement MCCB 400 Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 36 KA complete all as specified and directed.
49S&F inr replacement MCCB 315/350Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 36 KA complete all as specified and directed.
50S&F in replacement MCCB 250 Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 36 KA complete all as specified and directed.
51S&F in replacement MCCB 200 Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 36 KA complete all as specified and directed.
52S&F in replacement MCCB 160 Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 25KA complete all as specified and directed.
53S&F in replacement MCCB 100 Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 16KA complete all as specified and directed.
54S&F in replacement MCCB 63 Amp, Four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity 16KA complete all as specified and directed.
55Supply and installation, testing and commissioning in replacement of Battery 12volt 150 Ah with necessary items required for connection of battery complete all as specified and directed.
56Supply and fix copper busbar as per existing size of bus bar including mounted on saddle /porcelain insulator with screwing and making hole and connection for cables,MCCBs etc after testing of completion of works complete all as specified and directed.
57Supply and fix Aluminium busbar / PG Clamps or as per (site requirement)existing size including mounted on saddle /porcelain insulator with screwing and making hole and connection for cables,MCCBs etc after testing of completion of works complete all as specified and directed.
58S&F in repairs Digital type voltmeter of 0-500 volt range suitable for three phase supply including connection and testing complete all as specified and directed.
59S&F in repairs selector switches, 4 position, for volt meter and ammeter suitable for three phase supply including connection and testing complete all as specified and directed.
60S&F in repairs digital type ammeter of 0-500 Amps range suitable existing CTs for three phase supply including connection and testing complete all as specified and directed.
61Taking out unserviceable LED type indicator lamp unit from the panel boards , supply and fix LED type indicator lamp unit of red/ yellow/ blue/ green/ Amber with bulb including connection and testing complete all as specified and directed.
62S&F in repair new generation energy saving & environmental friendly long life versatile pressure die-cast aluminum IP-66 road way/street luminaries 70 watt LED with high power LEDs as light source and electronic driver including testing complete all as specified and directed.
63S&F in repair LED Highbay light of cap 150 watt made up of presure die-cast housing, integrated PC optics and up to 150 lm/w system efficacy IP-66 protection sytem , with high power LEDs as light source and electronic driver including testing complete all as specified and directed.
64S&F in repair new generation IP 65 LED Post top light of cap 15 watt energy saving ,enviornmental friendly long life esthetically designed with symetric light distribution spun aluminium land scape with high power LEDs as light source ,including testing complete all as specified and directed.
65S&F in repair LED Flood light of cap 120 watt made up of presure die-cast aluminum housing with toughned glass IP-66 protection sytem , with high power LEDs as light source and electronic driver including testing complete all as specified and directed.
66Repair & Maint of LT Panel board including all control cable , main switch ,cut out ,change over ,bus-bar ,porcelain chair/bakelite,insulator,all rusted ,nuts bolt washer and refixing after repair / replacement works mention below complete all as specified and as directed :-(i) Cleaning & grinding the bus-bar with carbon tetrachloride solution and provision of non adhesive colour coated tape for appropriate phase (R,Y,B) and neutral (black) over the bus-bar.(ii) Replacement of all nuts,bolt ,washer ,cable glands and porcelain insulator.(iii) Welding/brazing the sheet metal enclouser at the rusted places including broken hinges , making necessary.(iv) M&L for spray painting with synthetic enamel paint of existing colour over a coat of red oxide primer externally & internally including numbering complete all as specified and as directed.
67S&F in repair install, test and commisioning of LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of Stainless Steel sheet 3.15mm (outdoor type) thick through chemical treatment with 9 tank pre treatment process method for degreasing , derusting and phosphating powder coating with bottom frame made out of angle SS 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 250 Amps 6 way from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected iems complete :- FP No1 Incoming (i) MCCB 200 Amps, four pole with Adjustable thermal and adjustable magnetic release, 415 V AC supply, having rupturing capacity 25 KA - 01 No Outgoing (ii) MCCB 63 Amps, Four pole with Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 25 KA - 2 Nos (iii) MCCB 40 Amps, Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 25 KA - 2 No. (iv) MCB TPN - 25 Amp 10 KA -02 Nos(v) Indicating lamps set RYB - 01 Set (VI) Digital Amp Meter 0- 160 A with CT , Digital Voltmeter 0- 500 V
68S&F in repair, install, test and commisioning of LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of Stainless Steel sheet 3.15mm (outdoor type) thick through chemical treatment with 9 tank pre treatment process method for degreasing , derusting and phosphating powder coating with bottom frame made out of angle SS 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 250 Amps 6 way from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected items complete:- Incoming (i) MCCB 200 Amps, four pole with Adjustable thermal and adjustable magnetic release, 415 V AC supply, having rupturing capacity 36 KA - 01 No Outgoing (ii) MCCB 63 Amps, Four pole with Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 16 KA - 2 Nos (iii) MCCB 40 Amps, Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 16 KA - 2 No. (iv) MCB TPN - 32Amp 10 KA -02 Nos.(V)MCB DP - 32Amp 10 KA -05(vi) Indicating lamps set RYB - 01 Set (Vii) Digital Amp Meter 0- 160 A with CT , Digital Voltmeter 0- 500 V
69M & L in replacement PVC insulated, PVC sheathed Copper conductor electric cable 1.5 Sq mm 3 Core 1100 volts grade for pole box to street light fitting complete all as specified and directed.
70S&F in repairs 11-33kv Discharge Rod fiber glass high voltage Earthing & capacitive discharge stick,6 feet insulated handle ERDA testedfor HT panels,transformers switch yard ect including connected accessories complete all as specified and directed.
71S&F in repairs Aluminium strip of size 25x3.15mm with saddles and fixing with screws etc.for roof conductors and down conductors above ground complete all as specified and directed.
72S&F in repairs Termination joint kit outdoor/indoor for 1100 volt grade cable complete with Jointing material heat Shrink type and accessories suitable for 3 .5 core XLPE, armoured, Aluminium conductor cable of size 25 to 50 sqmm including testing complete all as specified and directed.
73All as per sl item No. 72 above but for cable of size 70 to 95 sqmm complete all as specified and directed.
74All as per sl item No. 72 above but for cable of size 120 to 150 sqmm complete all as specified and directed.
75All as per sl item No. 72 above but for cable of size 185 to 300 sqmm complete all as specified and directed.
76Supply, installation. connecting electrically and commissioning switch air break, gang operated, triple pole mounted on insulators 15 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating 200 amps and working voltage 11000 volts all including taking old unserviceable switch air break, gang operated as required at site or directed.
77Supply and fixing battery charger suitable for normal and boost charge suitable for 24 volts DC complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58579439
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 08-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance To External Electrification Lt Network Including Ug Cables, Lt Panels And Allied Works At At Sgnr Mil Stn
Basic Detail
Tender No GE SGNR/TOK-30 OF 2026-27
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 17 Nov 2026
Submission Date 08 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 89820
Exemption Available
Document List
8c3a2217-7cca-4016-8ca6-ea33024e1f76.html
BOQ_896573.xls
GenPage1.pdf
GenPage2.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

8c3a2217-7cca-4016-8ca6-ea33024e1f76.html

xls

BOQ_896573.xls

pdf

GenPage1.pdf

pdf

GenPage2.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender