Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 27 days TDR #58568570

Tender For Construction Of Exellence Center (T.T.L.) Government Girls Polytechnic Charkhari Dist. Mahoba

Issued by Boards / Undertakings / PSU · Mahoba, Uttar Pradesh
Tender Value
5.68 Crore
Estimated cost
Bid Submission
16 Dec 2026
27 days left
EMD
11.38 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mahoba → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Exellence Center (T.T.L.) Government Girls Polytechnic Charkhari Dist. Mahoba

BOQ

Name of Work:- CONSTRUCTION OF EXELLENCE CENTER (T.T.L.) GOVERNMENT GIRLS POLYTECHNIC CHARKHARI DIST. MAHOBA
Sl. No. Item Description
1Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) 300 mm dia piles
2Vertical load testing of piles in accordance with I. S. 2911 ( part iv ) including installation of loading plateform & preperation of pile head or construction of test cap & dismantling of test cap after test etc. complete as per specification and the direction of Engineer - in - Charge .Initial test (Test Load 2.5 times the Safe capacity) Initial Test Initial test (Test Load 2.5 times the Safe capacity)
3Vertical load testing of piles in accordance with I. S. 2911 ( part iv ) including installation of loading plateform & preperation of pile head or construction of test cap & dismantling of test cap after test etc. complete as per specification and the direction of Engineer - in - Charge .Initial test (Test Load 2.5 times the Safe capacity) Routine Test Routine capacity) test (Test Load 1.5 times the Safe
4Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. Excavation work by mechanical means /manual means upto 1.5 m.
5Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
6Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
8Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
11LDPE sheet below concrete
12Providing and laying Autoclaved Aerated concrete(AAC) blocks above the plinth level without RCC band with sill level with approved laying polymer modified adhesive.
1312 mm cement plaster of mix : 1:4 (1 cement: 4 course sand)
14Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
15Centering and shuttering including strutting, propping etc. and removal of form for:Foundation, Footings, Bases of column etc for mass concrete
16Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
18Factory Finished peb Structure comprising of built up columns built up truss frame, manufactured out of 345 Mpa hi-tensile steel of approved make JINDAL/ JSW/ SAIL/ TATA/ ESSAR/ APL APPOLO All Structural members shall be designed as per IS only Flange to web continuous welding will be done by submerged process arc process and rest joints will be done MIG welding process and shall be in accordance with AWS D 1.1 and D 1.3 as applicable. All welders shall be qualified and certfiled and certified for type of welds performed. Member shall be fabricated shall be kept minimum and given factory applied alkyd base DTM mono coat Paints System minimum 90-110 micron of approved make(Akzonabal, Asian Paint, Berger). All Structual member shall be disigned as per IS For built-up IS 800:2007 Limit state design and wind load as per IS 875 part 3, 2015 and for sismic IS 1893 (part 1)-2016 All cold form (If Required) purlin (if Required) Shall be manufactured out of 345 MPA and In depth of 200/230/250 mm as per approved GA Drawng. All cold form members (Side girt/Roof purlin) Shall be made of Hi-tensile Steel (Z-275Gsm Zinc Coated/345Mpa Confirming to ASTM-8653. All hot rolled secondary members like bracing angles conncection plates etc shall conform to IS:2062 with minimum yield strength of 250 Mpa. All bracing members shall be hot rolled rod or angle bracing as per final approved design and drawings the other component such as clips connection plates portal bracing anchor bolt etc shall be offered in MS Steel grade 245mpa be bolted connection. All Strcutural connection will be electroplated with 8-10 microns coating on high strength bolts conforming to IS 1364 or ASTM A325, grade. Minimum bolt size shal be 12mm diameter or as specified in approved drawing. All hot rolled Secondary members like bracing angines, connection plates etc shall conform to IS 2062 with minimum yield strength of 250 Mpa all bracing members be hot rolled angles. Anchor bolt (Black steel) Shall conform to ASTM F1554 grade 36 with minimum yield strenght of 245 Mpa. Nuts and lock nuts shall conform to IS 1363(Part 1 to 3)/ASTM A 563/ASTM A563M and Only plate washer will be used as per IS 2062 or ASTM A572. All anchor bolts shall have lock nuts. Anchor Bolts shall be designed considering concrete strenght. The Portion of anchor bolts project above concrete (inclusive of the part within grout) shall be mechanically cleaned and painted as per soec after erection. Anchor bolts shall not be less than 15-20mm of diameter. Total number of anchor bolts shall not be less than foru in any base plate. Rod or Pipe bracing is considerd on Roof as per approved GA For roof and wall cladding self-drilling screws shall confirm to AS-3566 Standard.
19Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
20Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
21Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD or equivalent. The framing section shall be cold form C-type having minimum web depth 89 mm x 39 mm flange x 11 mm lip in required length as per structural design requirement duly punched with dimples/slot at required locations as per approved drawings. The frame can be supplied in panelized or knocked down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads.
22Providing and fixing internal wall panels on Light gauge steel frame work with 12.5 mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8mm thick fibre cement board confirming to IS 14862:2011 of category III type B (High pressure steam curved) on both faces as per standard sizes fixed with self-drilling / taping screws / fasteners @ 30 cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60 mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.
23Supplying and installation of Wet area wall on Light Guage steel framework with, 9/6 mm thick heavy duty fibre cement board confirming to IS 14862:2000, category IV type A (High pressure steam curved) as per standard sizes fixed with self-drilling / taping screws/ fasteners @ 60cm c/c of approved make.
24Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with selfdrilling / taping screws / fasteners @ 60 cm c/c of approved make. A groove of 2 mm to 3 mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60 mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)Outer face- Outer face having 6 mm thick fiber cement board fixed on 9mm thick fiber cement board, Type A, as per IS:14862:2000 (high pressure steam cured). Inner Face- 12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8 mm thick fibre cement board confirming to IS:14862:2000 of type B (High pressure steam cured)
25Providing and fixing in all exterior face panels breathable vapour barrier underneath the cement fiber board as per National Building Code 2009 complete as per direction of Engineer-in-charge.
26Providing and fixing roofing with 30+23mm thick PUF isulated sandwich panels with density of 40+/-2 kg/sqm. The top covering on roof panels shall be made of PPGL sheet AZ150, 0.5 mm TCT and 550 Mpa trapezoidal pre-coated galvalume sheet with crest height 30+/-1 mm, crest width 24+/-1 mm and pitch 200+/- 1 mm & bottom covering on roof panels shall be micro ribbing pre-coated galvanized iron sheet.
27Roofing : Piched -0.47 mm TCT PPGL pofile sheet with insulation & roof accessories (Trims, Gutters, PVC Downcomer etc.)
28Providing and fixing 12.5 mm gypsum board false ceiling at all height finished with paint and putty including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges.
29Providing and fixing 12 mm thick Calsium Silicate false ceiling at all height finished with paint and putty including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges.
30Providing and laying Double Charges Vitrified floor tiles laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Size of Tile 600x600 mm/ 800x800 mm
31Providing and laying anti-skid Ceramic floor tiles in wet areas, of approved make, in all colours and shades, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. size of Tile 600x600 mm/ 300x300 mm
32Providing and installing ceremic full height wall tiles in wet area walls, of approved make, in all colours and shades, installed over Fibre cement board with the help of 3-5 mm thick suitable adhesive including grouting the joints with white cement and matching pigments etc., complete. Wall tiling has been considered for above areas only rest other areas shall be having couble layer board and approved paint finish. Size of the tile 300x300 mm/ 300x450 mm.
33Kota stone slab finish in Verandah area/ steps over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand).
3452 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete.
35Apply Epoxy paint on the hardend concrete.
36Interior Painting: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm.
37Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
38Exterior Painting: Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
39Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
40Providing and fixing 100 mm thick thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, within the LGSF frame wall cavity.
41Providing and fixing Tata Parvesh Steel door in single leaf and double leaf type as required in different size as per approved architectural drawings. The Tata Parvesh doors leaf's shall be made with Galvanized Iron sheet confirming to IS 277 and the infill materials shall be Honeycomb Kraft Paper. The doors shall be fitted with vision glass and necessary accessories like Mortise lock, Handle, Tower bolt, Flush bolts, Door closure, etc. shall also be provided as per approved drawings.
42Providing and fixing PVC doors in sizes as indicated in architectural drawings of bulding & Door shall be supplied with complete lock and hinges system as indicated in drawings.
43Providing and Fixing Motorised rolling shutter.
44Hydraulic Door closers (Heavy duty)
45Providing and fixing factory made uPVC white colour sliding glazed window comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.20+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), EPDM gasket, wool pile, with adjustable nylon rollers (weight bearing capacity to be 40 kg), after fixing frame the gap between frameand adjacent finished wall shall be filled with weather proof silicon sealent of approved quality, Glazing will be of 5mm clear toughened glass.2 track with sliding shutter.
46Providing and fixing mild steel railing, 1000 mm high, made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary GI nuts and bolts complete, i/c fixing the railing with necessary accessories & GI dash fasteners, GI bolts etc., of reuired size, on the top of the floor or the side of waist slab with suitable arragement.
47Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
48Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
49Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement
50Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
51Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm
52Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
53Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
54Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
55Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
56C/O Apron drain of width 230 mm and depth as per required of site but minimum 230 mm with neat finish & required slope as per apporoved by E/I.
57Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
58Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster.
59Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
60Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-15 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
61Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
62Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
63Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
64Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
65Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade
66Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
67Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe 32 mm dia 40 mm dia
68Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
69Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
70Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 75 mm O.D.
71Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 110 mm O.D.
72Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm
73Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
74Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 75 mm size
75Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 110 mm size
76Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 75 mm
77Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm
78Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 75x75x75 mm size
79Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 110x110x110 mm size
80Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 75 mm size
81Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 110 mm size
82Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 1473575 mm size
83Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 110 mm size
84Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 mm size
85Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali.
86Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25 mm nominal outer dia Pipes
87Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32 mm nominal outer dia Pipes
88Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes
89Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm nominal outer dia pipes
90Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25mm dia, nominal bore
91Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 32 mm dia, nominal bore
92Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
93Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
94Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore
95Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
96Supply and fixing of upvc s.w.r. pipe type-b confirming to is-13592 i/c jointing the pipes with rubber ring, lubricant and upvc swr cuplar confirming to is-14735 also i/c excavation of trenches cutting of walls and repairing the walls floors and refilling the trenches as before. But excluding supply and cost of other fitting such as elbow, bead tee and y-tee i/c supply of all material t& p.required for proper completion of the work internal toilet (soil & waste pipe). 160mm dia p.v.c. pipe
97Providing & laying cement concrete 1:2:4(1 cement :2 coarse sand :4 graded stone aggregate 40mm nominal size) alround S.W. R Pipes including bed concrete as per standard design. 160mm diameter S.W. R Pipe
98Supply and fixing of UPVC S.W.R. Gully trap conforming to IS-14735 size 150 x 110{ mm} dia of self cleaning design including fixed brick Masonry chamber 250 x250 x250(mm} size i/c supply and fixing of CI cover with frame wait not less then 4.50{ Kg}. & CI grating 150x150{ mm} complete in all respects. 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 15
99Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 15
100Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
101Providing and fixing C.I. tee at the inlet and outlet of septic tank.
102Providing & fixing 75mm dia vent pipes.
103Providing & fixing of 75mm dia cast iron terminal guard.
104Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter
105Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks
106Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group - C
107Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required Group -C
108Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
109Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
110Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 10 sq.mm + 1 x 6 sq.mm. earth wire
111Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
112Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 x 16 sq.mm + 2 x 6 sq.mm. earth wire
113Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
114Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
115Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
116Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
117Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep
118Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
119LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 degcentigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm) 36 watt
120Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim 8 - 10 watt
121Supply & installation of Highbay light 50 Watt ,Energy saving, high efficacy, enviroment friendly and robust highbay LED luminaire. IP66 suitable for 24Hr Continuous Operation, 160lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 4000K, complete in all respect,
122Supplying & installation of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor.
123Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 70 watt
124Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
125Supply, Installation, Testing and Commissioning of 750mm wall mounted single phase Industrial Fan complete in all respect as per engineer in charge. Make- Havells-FHACWSTSCL30 or equivalent.
126Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN
127Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB
128Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A,30KA,FPMCCB
129Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 125 A,36KA,FPMCCB
130Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door
131Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
132Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double door
133Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door
134Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 8 way (4 + 24), Double door
135Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps SP MCB
136Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps DP MCB
137Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps TP MCB
138Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps TP MCB
139Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps 4P MCB
140Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps 4P MCB
141Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps
142Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 40 amps
143Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
144Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
145Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
146Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
147Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
148Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
149Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. (The panel should be manufactured as per detailed SLD.) The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main LT Panel Incoming : One (1) No 320 Amp. 4P MCCB of 25KA Breaking capacity One (1) No 320 Amp. 4P ATS Metering :1 Set of CT's one of 320/ 5Amp ratio for Multifunction Meter 1 Set of Phase Indication Lamp.Bus Bar :One (1) No. 400 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.200 Amps FP MCCB of 25KA - 2 No 125 Amps FP MCCB of 25KA - 2 No 100 Amps FP MCCB of 25KA - 1 No 40 Amps FP MCCB of 25KA - 2 No Space for Spare-2 No Panel described as above
150Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. (The panel should be manufactured as per detailed SLD.) The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.GROUND FLOOR PANELIncoming : One (1) No 200 Amp. 4P MCCB of 25 KA Breaking capacity Metering : One (1) No. Sets Multifunction Meter each incoming One (1) No. of Phase Indication Lamp each incoming Bus Bar : One (1) No. 250 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 40 Amps FP MCB of 10KA - 2 No 32 Amps FP MCB of 10KA - 2 No 25 Amps FP MCB of 10KA - 2 No 40 Amps TP MCB of 10KA - 7 No 63 Amps TP MCB of 10KA - 4 No 2 No. Space for Spare Panel described as above
151Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. (The panel should be manufactured as per detailed SLD.) The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. FIRST FLOOR PANEL Incoming : One (1) No 125 Amp. 4P MCCB of 25 KA Breaking capacity Metering : One (1) No. Sets Multifunction Meter each incoming One (1) No. of Phase Indication Lamp each incoming Bus Bar :One (1) No. 150 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.25 Amps FP MCB of 10KA - 2 No 40 Amps TP MCB of 10KA - 7 No 63 Amps TP MCB of 10KA - 4 No 2 No. Space for Spare Panel described as above
152Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
153Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
154Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required.
155Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
156Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm.
157Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq.mm. and up to 95 sq.mm.
158Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm.
159Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle
160Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
161Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
162Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
163Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
164Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 150 sq.mm
165Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 70 sq.mm
166Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 35 sq.mm
167Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm
168Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 10 sq.mm
169Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 6 sq.mm
170Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 X 6 sq. mm (19mm)
171'Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 35 sq. mm (32mm)
172'Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 70 sq. mm (38mm)
173'Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 150 sq. mm (50mm)
174Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 X 10 sq. mm (25mm)
175Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 X 16 sq. mm (28mm)
176Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia
177Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
178Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
179Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
180Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
181Supply & fixing of following size (GI RACEWAY) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 100 mm x 40 mm x 1.6mm
182Supply & fixing of following size (GI RACEWAY) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 300 mm x 40 mm x 1.6mm
183Supply & fixing of following size of Raceway Junction Box made out of GI for electrical, Height adjustable & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 100 mm x 100 mm x 50mm
184Supply & fixing of following size of Raceway Junction Box made out of GI for electrical, Height adjustable & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 150 mm x 150 mm x 50mm
185Supplying, installation, testing & commissioning of 1.5 Ton Split Air conditioning unit (indoor & outdoor units) , 5 star rating with evaporator copper coil & imported refigerant joints with wireless remote controller & supply of Automatic Voltage stablizer, TDR wider range wall mounted, Hi-low cut, ISO-9001 certified:4/5 KVA and including copper refigerent piping of split type indoor and outdoor unit as per site requirement. Complete with placement of outdoor unit including hanging arrangement and including drain pipe as per site requirement, complete in all respects as directed by engineer in charge.1.5 TR
186Supply, Installation, testing and commissioning of Dome Camera (I.P.) Full HD image with a 1/2.7\\" 2 megapixel sensor or full HD 4 MP 20 fps image with a 1/3\\" 4 megapixel sensor.
187Supplying, installing, testing and commissioning of 40 Channel NVR quality and make approved by as per direction of engineer incharge.
188Supplying, installing, testing and commissioning of Hard disk Surveillance 8 TB quality and make approved by as per direction of engineer incharge.
189Supplying, installing, testing and commissioning of RACK 12 U quality and make approved by as per direction of engineer incharge.
190Supplying, installing, testing and commissioning of D.Link quality and make approved by as per direction of engineer incharge.
191Supplying, installing, testing and commissioning of LED Screen 50\\" quality and make approved by as per direction of engineer incharge.
192Supplying, installing, testing and commissioning of patch panel 24 port/fiber quality and make approved by as per direction of engineer incharge.
193Supplying, installing, testing and commissioning of Sfp Model quality and make approved by as per direction of engineer incharge.
194Supplying, installing, testing and commissioning of Fiber Cabin quality and make approved by as per direction of engineer incharge.
195Supplying, installing, testing and commissioning of CAT6 UTP cable 305 mtr quality and make approved by as per direction of engineer incharge.
196Supplying, installing, testing and commissioning of Online UPS with 30 Min Backup quality and make approved by as per direction of engineer incharge.
197Supplying, installing, testing and commissioning of HDMI Cable 10 Meter quality and make approved by as per direction of engineer incharge.
198Supply including laying & Installation of CAT 6A Cable quality and make approved by as per direction of engineer incharge.
199Supplying, installing, testing and commissioning of Connector RJ-45 quality and make approved by as per direction of engineer incharge.
200Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
201Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
202Supply and installation of 2500 Ltr water Tank along with MS structure staging including painting of structure with Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture etc. complete.
203Supply, installation, testing & commissioing of 30 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, inbuilt / external isolation transformer as per specification given in the document with following broad features. Including required panel and cables. THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. ( Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be external type with rack and suitable for 30 minute backup on 100% load. UPS shall be compatible for minimum 2 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
204Supply, Installation testing & commissioning of 6,200 ANSI lumens 3-chip 3LCD projector having resolution Full HD 1080p, Contrast ratio 2,500,000:1, Horizontal and Vertical Keystone Correction ±30°, Should have 2 or more HDMI, 2 or more VGA, 1 or more HDBaseT, 2 or more Audio 3.5mm in, 2x USB, 1x Ethernet (RJ-45); Outputs: 1x HDMI out, 1x Audio 3.5mm jack out, Control: RS-232, LAN (RJ-45) Ethernet(10/100 RJ-45), Should have Throw distance of Projector from Screen: 5.85 Mtrs - 9.4 Mtrs or better complete with all standard accessories.
205Supply, Installation, Testing & Commissioning of Mounting/ Hanging arrangements for the above given projector complete with standard accessories as required.
206Providing and fixing 450X900 powder coated 4-6mm MS sheet and 25mm Corian Signage at desired locations with letters (in english & hindi) and illustrations - etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge
207Providing and fixing 200X450powder coated 2-4mm MS Signage at desired locations with letters (in english & hindi) and illustrations - etched, through cut, infilled or painted as per the design approved from Architect in charge, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge.
208Providing and Fixing 3 mm Acrylic Laser Cut Letter embossing 50 mm with 4 mm Sun board female channel with ribbon LED light with 3 mm aluminum composite panel with 40 mmx40 mm square MS pipe frame inside the ACP sheet. Top Big Letter Size 26\\" with vowel diacritic and bottom small letter 16\\" with vowel diacritic. Board size 24 feetx5 feet with transportation and installation complete in all respect as per direction of Engineer incharge.
209S/F of Surface mount box with I/O Cat 6 and UTP jack D-Link complete in all respect Make Dlink/Amp
210S/I of Patch cord CAT6 UTP Make Dlink/Amp
211S/I/T/C of 24 port category 6e SL Series patch Panel Make Dlink/Amp with active and passive components,punching, complete in all respect
212Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus
213Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts.
214Mapping of Network Nodes & LAN Diagram
215SITC of WIFI Modem suitable to cover atleast 25m distance having compatibility to connect atleast 40-50 devices without any distortion in signal etc as required.
216Student Chair, PP Seat Back, Blue Colour Powder Coated Pipe Frame GEEKEN MODEL NO.GST 821 AND GEEKENsl no. 777
217Visitor Chair, PP handle, Seat Velvet and Back Net Tapestry, MS powder coated frame GEEKEN MODEL NO. LIBERTY 6 AND GEEKENsl no. 124
218Student / Training Room Chair, PLPB Writing Pad, Powder Coated Pipe Frame, Book Tray Under Seat, Seat Back Fabric Tapestry GEEKEN MODEL NO GST 807 AND GEEKENsl no. 772
219ALLMIRAH Wooden Storage, Particle Board Structure GEEKEN MODEL NO STORAGE 4 AND GEEKENsl no. 456
220Three Seater Sofa, Wooden Frame, Wooden Gold Plated Leg, Size (in mm): 2120(L) X 900(D) X 850(H)Asmara Fine Leatherette Tapestry GEEKEN MODEL NO. STEPHEN 3 AND GEEKENsl no. 478
221TABLE Computer Desk, Pre-Laminated Particle Board, Fixed Pedestal W1050 X D600 X H750 GEEKEN MODEL NO. COMPUTER DESK 7 AND GEEKENsl no. 443
222VISITER TABLE - Pre-Laminated Particle Board, Without Pop Up BoxW1800 X D900 X H750 GEEKEN MODEL NO. CONFERENCE 16 AND GEEKENsl no. 430
223Workstation Table, Panel Based Partition, Particle Board Edge Banded Top W4000 X D1260 X H1200 GEEKEN MODEL NO. MR ANDGEEKENsl no. 413 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58568570
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 5.68 Crore
LAST DATE 16-12-2026
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Tender for Construction Of Exellence Center (T.T.L.) Government Girls Polytechnic Charkhari Dist. Mahoba
Basic Detail
Tender No 604/SE/BUND CIRCLE/AC-03/143 Dated- 03.11.2026
Bidding Type Tender
Location
City Mahoba
State Uttar Pradesh
Key Dates
Publish Date 17 Nov 2026
Submission Date 16 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 5.68 Crore
Tender Fee 8850
EMD 11.38 Lakhs
Exemption Available
Document List
4a77b4d5-1510-4b74-a59a-844132c192af.html
BOQ_2296376.xls
FINAN.pdf
TECHI.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

4a77b4d5-1510-4b74-a59a-844132c192af.html

xls

BOQ_2296376.xls

pdf

FINAN.pdf

pdf

TECHI.pdf

pdf

Tendernotice_1.pdf

Disclaimer