Tender For Electrical Wiring For 03 Nos. Of New Rooms, Provision Of Ac Points And Dg Backup Supply For Computers And Other Areas And Associated Electrical Works In 09 Nos. Of Classrooms/Halls In Connection With Civil Renovation Works At Bti Institute
Tender Overview
Project Description
Tender for Electrical Wiring For 03 Nos. Of New Rooms, Provision Of Ac Points And Dg Backup Supply For Computers And Other Areas And Associated Electrical Works In 09 Nos. Of Classrooms/Halls In Connection With Civil Renovation Works At Bti Institute, Lakhanpur Area
BOQ
| Sl. No. | Item Description |
| 1 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directlyon ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 2 | Providing of 200 A, TPN Switch Disconnector Fuse Unit as per instruction of Engineer incharge |
| 3 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 4 | Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. |
| 5 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required (63A). |
| 6 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.(For 8 way, Double door TPN MCB DB) |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(5 x 6 sq. mm) |
| 8 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MOB DB complete with connections, testing and commissioning etc. as required.(63A) |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.( 2 X 4 sq. mm + 1 X 4 sq. mm earth wire) |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 11 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 12 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existingMCB DB complete with connections, testing and commissioning etc. as required.( 40A) |
| 13 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residualcurrent circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.(40A) |
| 14 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden blockincluding connections etc. as required |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.10 A single pole) |
| 16 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. painting etc. as required.(12 Module (200mmX150nnm)) |
| 17 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. painting etc. as required.(6 Module (200mmX75mm)) |
| 18 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(5/6 A switch) |
| 19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(3 pin 5/6 A socket outlet) |
| 20 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(15/16 A switch) |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(6 pin 15/16 A socket outlet) |
| 22 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 23 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.( 25 mm) |
| 24 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender