Tender For Maintenance Of electrical installation In Nonresidential Buildings Under U.T. Chandigarh (Repair & Replacement Of Defunct Campus Lighting Fittings And Other Electrical Accessories Installed In Govt. Industrial Training Institute For Women
Tender Overview
Project Description
Tender for Maintenance Of electrical installation In Nonresidential Buildings Under U.T. Chandigarh (Repair & Replacement Of Defunct Campus Lighting Fittings And Other Electrical Accessories Installed In Govt. Industrial Training Institute For Women And Post Graduate Govt. College (Co-Ed)Atsector-11, U.T. Chandigarh).
BOQ
| Sl. No. | Item Description |
| 1 | DSR Item no.2.2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 2 | 63/100 A,30KA, FPMCCB |
| 3 | DSR Item no. 2.10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 4 | Triple pole and neutral |
| 5 | DSR Item No.5.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 6 | DSR Item No. 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 7 | DSR Item No. 15.15Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 8 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 9 | DSR item no. 8.13LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L, N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK 10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 10 | 50 watt |
| 11 | DSR item no. 8.16LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 12 | 100 watt |
| 13 | Supply and erection of thermoplastic cable junction box of size 300 x 250 x 98 mm of make Hansel/ Legrand/ Sintex/ GE Power/ Rittal/ L&T/ Siemens, with terminal strip of Wago/ Elimen/ Siemens/ Everest of rating more than 60 Amps with prefixed 4 Nos. Bolts, 8 Nos. Nuts & 8 Nos. Washers and 8 Nos. Aluminum 16/25/50 thimbles with insulating caps in existing cement collar. The strip shall be fixed in Junction Box with the help of nuts and bolts. The Jn. Box shall be fixed on the existing pole at required height with the help of flexible G.I. Strip clamps nut bolts as required. The junction box shall be installed after dismantling of existing damaged junction box. The job includes cost of cement sand required to complete the job. The job also include the cost of labour, incoming & outgoing connection and other petty material require to complete the job to the entire satisfaction of the Engineer-in-Charge of the work. |
| 14 | Repair of existing cement collar. The job includes cost of labour charges, cement, sand, bajri and other petty material required to complete the job to the entire satisfaction of Engineer-in-charge of the work. |
| 15 | Providing two coats of superior quality snowcem in the existing collar and Painting of junction box. The junction box shall be painted with 2 coat red paint after rubbing the dust from the junction box. The job includes the cost of labour& all petty material required to complete the job to the entire satisfaction of E.I.C of the work. |
| 16 | Painting of street poles with double coat of Asian/Narolac/Delux Aluminium paint of following sizes installed along the roads, parking area and the poles shall be painted with superior quality of sliver colour. The job includes cost of all labour, & petty material required to complete the job to the entire satisfaction of Engineer in charge of the work. |
| 17 | Painting of street light pole up to 7 mtr. with the help of ladder & using boom after 7 Mtr to the height of 9 Mtr where ever required. The job includes cost of 2 no labour required for holding the ladder & controlling the traffic while using crane/boom. |
| 18 | Street light pole 5 Mtr., 7 Mtr. and 9mtr. long with single/double/triple arm bracket complete in all respect. |
| 19 | Numbering on existing S/L pole. The job includes the painting of pole in 4” dia round with yellow paint and make number with black paint. (1 number on each pole) |
| 20 | Numbering of fitting A for single arm bracket and B for double arm along with name of the road |
| 21 | Painting of existing outdoor cubical pedestal with red paint after removing the rust from the pedestal. The cubical pedestal shall be painted with one coat of primer and two coat of superior quality of red paint as approved by Engineer-in- charge of the work. |
| 22 | Supply and laying of PVC insulated aluminum conductor unarmored cable 10 mm² 2 core flat with 6 SWG GI Earth wire on existing surface with suitable clamps/ Hangers etc. The job including making connection and petty material such as labouretc as required to complete the job as per satisfaction Engineer in charge. The cable should be of Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/Grandlay make only. |
| 23 | Supply and Laying of following PVC insulated and PVC sheathed copper Cond. Un Arm. & Served cable working voltage upto 1100 Volt. Grade of following size to be laid in existing trench / pipe. The job include the cost of making connections with suitable size of copper Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. |
| 24 | 16 Sq.mm 4 Core PVC Ar. Aluminum Conductor Cable |
| 25 | 25 Sq.mm 3.5 Core PVC Ar. Aluminum Conductor Cable |
| 26 | Supply and Erection of Driver for LED Various LED fittings on the ceiling at a height of 15 feet. The job include cost of dismantling and re-erection of existing fitting etc. required to complete the job. The job includes the cost of Labour, T&P required for making connections, testing and commissioning etc. as required to the entire satisfaction of Engineer in Charge. The Driver should be of Bajaj/ Wipro/ Philips/ Surya/ Twinkle/ Jaquar. The driver should be compatible with existing fitting driver. |
| 27 | LED driver for 1’x4’ fitting 36 watt Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender