Public Administrative Department Local Bodies Closing in 9 days TDR #58568322

Tender For Construction Of Indoor Badminton Stadium With Changing Room And Toilet At Mahimunda,Puintala

Issued by Local Bodies · Balangir, Odisha
Tender Value
41.57 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
9 days left
EMD
41575
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Indoor Badminton Stadium With Changing Room And Toilet At Mahimunda,Puintala

BOQ

Name of Work:- CONSTRUCTION OF INDOOR BADMINTON STADIUM WITH CHANGING ROOM AND TOILET AT MAHIMUNDA,PUINTALA
Sl. No. Item Description
1Earth Work : AR0102aa (Earth work in hard soil or gravelly soil foundation & plinth within 50m. Initial lead and 1.5m initial lift) : Earth work in hard soil or gravelly soil foundation & plinth within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge
2Earth Work : AR0115 (Filling foundation and plinth with sand well watered and rammed) : Filling foundation and plinth with sand well watered and rammed including cost, conveyance, royalty, taxes of all materials, labours and T & P required for the work etc. complete and as per direction of Engineer-in charge.
3Concrete : AR0303 (Cement concrete (1:3:6) with 4 cm. Crusher Broken hard granite metal) : Cement concrete (1:3:6) with 4 cm. hard granite(Crusher Broken) metal including laying in layers not exceeding 300 mm in depth, ramming, compacting to proper thickness, watering and curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge.
4R.C.C. Work : AR0404Aa (Reinforced cement concrete work of M-20 grade with 20mm & down grade size black hard crusher broken granite chips) : Reinforced cement concrete work of M-20 grade with 20mm & down grade size black hard crusher broken granite chips including hoisting and laying in position compacting to specified design section and curing for proper period with cost conveyance, royalty,taxes of all materials, labour and T&P required for the work etc. (including centring and shuttering) complete and as per direction of Engineer-in charge (RCC foundation, footing bases of column, mass concreate, pre-cast slabs etc.)
5Masonry Brick Work : AR0603c (Flyash Bricks of size (23cm x 11cm x 8cm) in cement mortar (1:6) in foundation and plinth) : Brickwork with Flyash Bricks of size (23cm x 11cm x 8cm) in cement mortar (1:6) in foundation and plinth having crushing strength not less than 75.00 Kg/cm2 with dimensional tolerance ±8 percent immersing the bricks in water not less than six hours with cost conveyance, royalty, taxes of all materials, labor, and T&P required for the work, etc. complete and as per direction of Engineer-in-charge.
6R.C.C. Work : AR0409 (Supplying, fitting, and placing uncoated HYSD bar reinforcement including labor charges for cutting, bending, binding, and tying the grills and placing in position) : Supplying, fitting, and placing uncoated HYSD bar reinforcement including labor charges for cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge with cost of steel rod and as per drawing, design, and direction of Engineer-in-charge.
7Flooring : AR0802i (2.5 cm thick A.S. flooring in C.C (1:2:4) with 12 mm size HG crusher broken chips) : 2.5 cm thick A.S. flooring in C.C (1:2:4) with 12 mm size HG crusher broken chips including punning incl. cost, conveyance & royalty of materials as per direction of Engineer-in-charge.
8Roofing : AR1132i (Supplying, feeting & fixing of G.C.I. Sheet (0.40mm thick) in roof drilling hole in wind ties) : Supplying, fitting & fixing of G.C.I. Sheet (0.40mm thick) in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. including cost of fitting, Labour and material etc. complete as per direction of Engineer-in-Charge
9Iron Work : AR1703 (Iron work wrought and put up in trusses and record racks) : Iron work wrought and put up in trusses and record racks including all cost of labour, material, machinery and T & P required for the work etc. as per direction of Engineer-in-Charge.
10Project Pillar
11parking shed/store room /guard room Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked MakeSchneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.| box with metallic cover plate (both side) MakeSchneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in - Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.warrantyperiod for acceptance of materials. GROUP-A
12GROUP-B
13GROUP-C
14Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. MakeSchneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for accptance of materials.
15Supplying fixing of 1x16APlug on the separate board with completing fitting by 01 no of 6A switch & socket(modular type) & other required a required accessories of ISI marked as approved as per direction of Engg. -in -Charge. MakeSchneider(Zencelo)/legrand( Myrius) /Panasonic (vision)(For equipment power) .All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for accptance of materials.
16Supplying fixing of ISI Marksed modular type2nos 6Amp socket with switch on suitable size of matel box and modular cover in front on surface or recess including all connection as per direction of EIC.All the switch sockets should be warrantied for a replacement of perion of2 years against defectwith necessary test report & warranty certificate to submitted to the department for genuity of product & to avail free aftersales servicewith in warrantyperiod for replacement for acceptance of materials.(Make:legrand( Myrius)/Schneider(Zencelo) /Panasonic (vision)
17Recessed wiring for circult/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable MakeFinolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V GAURD in recessed HMS FRLS PVC conduit of mentioned size MakeAKG/BEC/Precision/Norpak/Kinjal as required as per direction of Engg. in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 nos of single core 1.5 sq. mm copper wire for earth continuty conductor In 20 mm dia non metallic heavy duty conduit.(LDB to LSB/light ckt ))2x1.5 Sq.mm.+ 1x1.5 Sq.mm
18Recessed wiring for circult/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable MakeFinolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V GAURD in recessed HMS FRLS PVC conduit of mentioned size MakeAKG/BEC/Precision/Norpak/Kinjal as required as per direction of Engg. in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 nos of single core 1.5 sq. mm copper wire for earth continuty conductor In 20 mm dia non metallic heavy duty conduit.(BDBto LSB/light ckt/5A PLUG/UPS POINT ))2x2.5 Sq.mm.+ 1x1.5 Sq.mm
19Recessed wiring for circult/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable MakeFinolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V GAURD in recessed HMS FRLS PVC conduit of mentioned size MakeAKG/BEC/Precision/Norp hor/Kinjal as required as per direction of Engg. in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 nos of single core 1.5 sq. mm copper wire for earth continuty conductor In 20 mm dia non metallic heavy duty conduit.(PDBto PSB/POWER POINT/AC POINT )2x4 Sq.mm.+ 1x1.5 Sq.mm
20Recessed wiring for circult/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable MakeFinolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster in recessed HMS FRLS PVC conduit of mentioned size MakeAKG/BEC/Precision/Norp hor/Kinjal as required as per direction of Engg. in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 nos of single core 2.5 sq. mm copper wire for earth continuty conductor In 32 mm dia non metallic heavy duty conduit.(TO EACH FLAT BDB)2x6Sq.mm.+ 1x2.5 Sq.mm
21Recessed wiring for circult/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable MakeFinolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster in recessed HMS FRLS PVC conduit of mentioned size MakeAKG/BEC/Precision/Norp hor/Kinjal as required as per direction of Engg. in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 01 nos of single core2.5 sq. mm copper wire for earth continuty conductor In 32 mm dia non metallic heavy duty conduit.(TO EACH FLAT BDB ))4x6Sq.mm.+ 1x2.5 Sq.mm
22Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure SCHNEIDER/SEIMENS/LEGRAND/ABB of suitable size as required as per direction of Engg in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
23Supply and fixing CALL Bell (Ding dong type) ‘Buzzer on the existing switch box/cover.Make-Schneider(zencelo)/legrand Myrius/Panasonic (vision) as required as per direction of Engg.-in Charge. All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
24S/F of Bakelite angle holder/ batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to 1S-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warmaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
25S/F of 9 watt LED bulb of an approved ISI Make (Bajaj/ Havells/Crompton/Philips) Sub-Head II (Light fitting Fixture & Fan)
26sub head II (light fitting fixture & fan): Supplying, installation, testing and commissioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery >=215m3/min Make-Crompton Energion Groove/ Havells Efficiencia Neo/ Usha Technix/ Bajaj Turbo Pro 12DC5) including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Eng.-in-Charge, Replacement Warranty will be 4 years.
27SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser: having 2 years warranty i/c connection etc as required as per direction of Engg.-inCharge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
28S/F of 5 step type Modular electronic Fan Regulator 1SI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider (Zencelo) legrand (Myrus) /Panasonic (vision)
29Supp ying and fixing of Energy efficent surface /recess mounted square /round shape 18W LED lumnare of dimension of consists of white powder coated , die-cast Alumnum housing with high qua ity frosted diffueser for glarefree uniform lighting distribution with wattage not more then 18 watt and lumen output of 1800lumens CRI Not less then 80 cct 0f 6000 deegree k, thd less then 10% with electric driver, internal serge protection of 3KV, L70 B50 :50000 hrs and all other assecessories suitable for operation on 220V TO 240V supply requird as per engineer in charge(make panasonic/LT/HAVELLS/PHILLIPS/WIPRO/CROMPOTON BAJAJ)The luminaier should be replacedment warranty will be 2 year to be use in corridoor rooms dinning area
30Supplying and fixing installation of exhaust of heavy duty 300mm sweep1400 rpm with louvers (make -havells,cromption,usha, bajaj, orient)of exaust fan in the existing wall including fixing & connecting as required as per direction of engineer in charge.replacement warranty will be 2years
31Supplying and fixing installation of 100 watt WALL MOUNTED INDUSTRIAL METALIC fan of 450 mm sweep 1440 rpm 150 cum /min aluminium blade 100%copper binding 3 speed control(makeHAVELLS/CROMPOTON/usha/BAJAJ/ORIENT) OF WALL FAN IN THE EXISTING WALL, including fixing& connection as required as per direction of engineer in charge. replacement warranty will be 2years
32SITC of high-quality integrated LED Flood Light with a minimum ‘system ‘lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with \\"SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum :(ADC12) to withstand extreme environments. The luminaire should come with with PF “> 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal Surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating ie. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die, mid power ,Integrated arrays and COB's are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs , should have an auto shutdown @ 325V and have an auto recovery feature. The drivers shouid be a potted driver not a printed circuit board without casing, mounted inside the Luminaire. The fixture shall have warranty of 5 years. LM79,LM80, Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shail be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement.(4 Nos. for each pole) Only sport series flood light will be accepted. MakePhilips/ Lighting Technologies/ Schreder/Equivalent
33‘ Supplying,laying of 3c x 2.5 sq.mm copper flexible cable with insulated cover of reputed make, ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
34BDBS,DB,AC DB,FLOOR PANELS, MCBS : Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC , 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ SchneiderActi 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. Supply and fixing of 4 way (4+12) way DD TPN sheet steel MCB distribution board ~ 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth ‘ bar, din bar, detachable gland plate, interconnections, phosphatized and powder i painted including earthing etc. as required (but with out MCB/ RCCB/ lsolator) Warranty. fon DBis3 ears. ew oem sett ante de mem 7 1 Supply and fixing of 12 way “DD single pole and neutral sheet steel MCB distribution board 250V on surfawarranty on D Bis 3 years
35Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
36Supplying and fixing 6-32 Amps rating, C series, 10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ SchneiderActi 9/ABB $B 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. ., The MCB should be Replacement warrenty will be 1 year
37Supplying and fixing 63Amps 4P 415 volts MCB 16KA Make-LEGRAND-DXx3 / SiemensBetaguard/ SchneiderActi 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be _ Re+-lacement Warranty will be 1 year
38Supplying and fixing 63Amps 2P 240 volts MCB 10KA Make-LEGRAND-DX3 / SiemensBetaguard/ SchneiderActi 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year Supplying and fixing 32Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3
39Supplying and fixing 32Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ SchneiderActi 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year
40Earthing INSTALLATION:Supplying installation,testing & commissioning of materials and installation of GI Pipe earthing of 3 mtr long, 40 mm dia ISI marked with G.I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer in-charge.
41Providing and fixing 25mm x 5 mm Gl strip on surface or in recess for connections etc. as Required as er direction of Engineer-in-Charge.
42MAIN CONTROL PANEL AT- GF: S/I/T & commissioning of main LT indoor floor mounted CPRI Tested Cubical type main pannel made out by 2mm CRCA steel sheet duly derosted & painted by simens grey powder cote paint is designed as G.A Drawing as per direction of Engg. in charge Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 40X10MM Separate Aluminium Earth bus bar should be installed. Alll the incomers shall have 65 KA 3P+N type 1+2 SPD with 63 A 4P MCB, C series, 10 KA. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders. in commer-1-01 number of 63A 4P icu=100% lcs,36KA LSIG MCCB with micro processor based release (Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ABB FURMULA in commer-2-01 number of 63A 4P unload Dchainge over switch,36KA LSIG MCCB with micro processor based release (Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ABB Formula Busbar- 04 number of 100AMPS aluminium busbar with 1A/Sqmm current carring capaity. busbar duly sleeved by color coated PVC Sleeve & supported by suitable size DMC insulator out going 01- 3 numberof 63 mA rating 10KV braking capacity C SERIES FP MCB (Make-LEGRAND-DPX3 / Siemens-Betaguard/schneiderActi 9//AABB SB 200 out going 02-4 numberof 63 mA rating 10KV braking capacity C SERIES FP MCB (Make-LEGRAND-DPX3 / Siemens-Betaguard/schneiderActi 9//AABB SB 200 Instrument(i)03 numbers phaseindicatinglmp withtoggle switch &HRC Fuse (ii)one set ofdigital typemultifuctionmeter withCT for voltage current frequincy PF THD indicator withRS 485 COMPACTIVITYfor bms data
43CABLING:supplying & laying of one number PVC insulated armoured and PVC sheathed XLPE AL. Conductor power cable of 1.1 KV grade POLYCAB/KEI/HAVELLS ISI MARKED make of following size cable as per direction of Engg.-in-Charge. Ncessary test. report & warrenty certificate to be submitted to the department for genuinity of product and to avail after sales service within warrenty period for acceptance of materials. 4 core x 16 sqmm
44laying of one number PVC insulated PVC seated / XLPE power cable 1.1 KV grade ize not exceeding 25 sqmm direct in ground in the trench in one horizental formation including excavation, sand coushing protection covering and refilling the tench etc as required as per direction of Engg. in charge.
45supplying one number of PVC insulated armoured and PVC seated XLPE property Al. Conductor power cable 1.1 KV grade Make- Finolex/ Polycable/ Heavells/ RR Cable/KEI/Gloster of following size cables as per direction of Engg. In Charge 4 core x 16 sqmm
46Electrical line plan Board Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58568322
AUTHORITY Local Bodies
TENDER VALUE 41.57 Lakhs
LAST DATE 01-12-2026
Authority
Authority Name Zilla Parishad
Work Description Tender for Construction Of Indoor Badminton Stadium With Changing Room And Toilet At Mahimunda,Puintala
Basic Detail
Tender No 02/PSPUINTALA/2026-27
Bidding Type Tender
Location
City Balangir
State Odisha
Key Dates
Publish Date 17 Nov 2026
Submission Date 01 Dec 2026
Open Date 02 Dec 2026
Finance
Tender Value 41.57 Lakhs
Tender Fee 6000
EMD 41575
Exemption Available
Document List
73e15da2-117d-4a3b-8192-4c0e594ba068.html
BOQ_621672.xls
MahimundaIndoorstadium.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

73e15da2-117d-4a3b-8192-4c0e594ba068.html

xls

BOQ_621672.xls

pdf

MahimundaIndoorstadium.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender