Tender For Construction Of 4.00 Lakh Lit. Oht At 6Th Ward Thiruvalluvar 4Th Ward Ariyalur Main Road In Poovalur Town Panchayat
Tender Value
1.21 Crore
Estimated cost
Bid Submission
30 Nov 2026
7 days left
EMD
1.21 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruchirappalli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 4.00 Lakh Lit. Oht At 6Th Ward Thiruvalluvar 4Th Ward Ariyalur Main Road In Poovalur Town Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. PWD Sl,No: 120 as per TNSS 23 & 24, V, VI (S2), VII, 9,10 |
| 2 | First depth of 2m |
| 3 | Soft distinged rock PWD SOR Page No : 29 W 0062 |
| 4 | Second depth of 2m in Dense medium rock PWD SOR Page No : 29 W 0064 |
| 5 | Supplying and filling in foundation, basement, etc with filling Stone Dust in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.TNSS No. 24 & 25. |
| 6 | Plain Cement Concrete of mix 1 : 4 : 8 (One part of Cement four part of sand eight part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII |
| 7 | 1.5m to 4.5m below GL |
| 8 | Upto 1.5m below GL |
| 9 | Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. |
| 10 | Below G.L. |
| 11 | Below G.L upto 1.50m depth |
| 12 | 1.50m to 4.50m depth from G.L |
| 13 | Above G.L |
| 14 | Above G.L upto 4.50m height |
| 15 | Above 4.50m to 7.32m ht., from G.L |
| 16 | Above 7.32m to 10.98m ht., from G.L |
| 17 | Above 10.98m to 14.64m ht., from G.L |
| 18 | Above 14.64m ht., to 18.30m ht., |
| 19 | Above 18.30 m to 21.96m ht., from G.L |
| 20 | Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as Coloumn footing,Coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floors Complying with standard Specification without Strutting. ( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII |
| 21 | Plane Surface |
| 22 | Upto 3.30m ht., below GL |
| 23 | From 3.30 - 4.30M above GL |
| 24 | 7.30 - 8.30M above GL |
| 25 | 10.30 - 11.30M above GL |
| 26 | 15.30 - 16.30M above GL |
| 27 | From 3..3m to 4.3 m from floor slab |
| 28 | Centering for Square column |
| 29 | upto 3.30m ht. Below GL |
| 30 | upto 3.30m ht. |
| 31 | From 3.30m to 4.30m ht. |
| 32 | 4.30 m to 5.30 m height |
| 33 | 5.30 m to 6.30 m height |
| 34 | 6.30 m to 7.30 m height |
| 35 | 7.30 m to 8.30 m height |
| 36 | 8.30 m to 9.30 m height |
| 37 | 9.30 m to 10.30 m height |
| 38 | 10.30 m to 11.30 m height |
| 39 | 11.30 m to 12.30 m height |
| 40 | 12.30 m to 13.30 m height |
| 41 | 13.30 m to 14.30 m height |
| 42 | 14.30 m to 15.30 m height |
| 43 | Centering for Circle column |
| 44 | upto 3.30m ht. Below GL |
| 45 | upto 3.30m ht. |
| 46 | From 3.30m to 4.30m ht., |
| 47 | From 4.30m to 5.30m ht., |
| 48 | From 5.30m to 6.30m ht., |
| 49 | From 6.30m to 7.30m ht., |
| 50 | From 7.30m to 8.30m ht., |
| 51 | From 8.30m ht., to 9.30m ht., |
| 52 | From 9.30m ht. to 10.30m ht. |
| 53 | From 10.30m ht. to 11.30m ht. |
| 54 | From 11.30m ht., to 12.30m ht., |
| 55 | From 12.30m ht., to 13.30m ht., |
| 56 | From 13.30m ht., to 14.30m ht., |
| 57 | From 14.30m ht., to 15.30m ht., |
| 58 | Centering for curved surface |
| 59 | 14.30 - 15.30M above GL |
| 60 | 15.30 - 16.30M above GL |
| 61 | From 0m to 3.3 m from floor slab |
| 62 | From.3m to 4.3 m from floor slab |
| 63 | Supplying ribbed tor steel rods including cutting cranking fabricating assembling laying in exact position tying with soft steel wire 16 or 18 BWG etc. complete for all RCC Works. as per the design given including cost of steel and binding wire also in all floors as per standard specification. SS86 & 86A, V, VI (S3) (S6) VII. |
| 64 | Below G.L. |
| 65 | Ground Floor |
| 66 | First Floor |
| 67 | Second Floor |
| 68 | Third Floor |
| 69 | Fourth Floor |
| 70 | Fifth Floor |
| 71 | Supplying and Painting the new plastered walls with two coats of Exterior emulsion paint (weather proof ) first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt etc. complete and including necessary plaster paris putty etc. wherever required.as per (ISI STD) (It mustprovide excellent resistance against the growth of algae and fungi on the walls. And it must offer excellent protection against alkali and UV degradation and the durability period should be 5 years. 61 V, VI (S4) 3 |
| 72 | Providing and fixing RCC inside access ladder of approved pattern and design in RCC M20 design mix of ISS gauge 0.40m width, 0.10m thickness, 0.12m breadth for side post, 0.05m thickness 0.12m breadth for steps with suitable inclination including cost of cement, reinforcement centering, finishing, curing etc., complete and as directed by Departmental Officers. |
| 73 | Construction of RCC Spiral stair case in RCC M30 design mix concrete of 1.80m dia of required height for approach to the roof of Service Reservoir with RCC hand rails as per type design No.Sanitary Engineer/PH(M) NO.18/64 - 65 Sanitary Engineer(PH) 3/64 including necessary earth work excavation in various classification of soils met with at the site of work for providing foundation concrete in CC 1:4:8 mix, RCC footing M30 mix, GL platform etc., including cost of steel reinforcement, fabrication charges, scaffolding, centering precasting charges, cement painting the surfaces etc.,complete and as directed by the Departmental Officers. The staircase shall be braced to the column of Service Reservoir at suitable interval (Height is mentioned from GL to roof slab) |
| 74 | Providing and fixing in position of precast RCC (1:11/2:3) Hand rails of approvced design for one meter height by using 20mm HBG stone including cost of all materials, centering, shuttering, strutting, reinforcement, placing of concrete, finishing, curing and fixing in position on the roof slab etc.,complete and as directed by dept officers. |
| 75 | Supply,delivery and fixing in position of CI Manhole frame with cover of size 0.60m x 0.60 (heavy duty) etc.complete and as directed by TWAD Board Officers. |
| 76 | Supply and fixing in position ventilator of reinforcement cement concrete RCC M20 design mix 50 CM wide/diametre of approved pattern and design including cost of cement, reinforcement centering, shuttering, strutting, curing and fixing in position on the roof slab with mosquito proof net arrangement etc., complete. and as directed by the Departmental Officers. |
| 77 | Refilling the sides of foundation with excavated earth (other than sand) in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification removing and spreading the surplus earth at the placed shown and as directed by the Departmental Officers. PWD SOR Page No : 32 Sl. No : W-0075 |
| 78 | Supplyong of Ductile Iron class PN - 10 flanged pipes as per IS 8329/2000 (each double flanged pipe length shall be 2.0m) TWAD,P.No - 37 WD M 0686 |
| 79 | For over flow 250mm dia TWAD,P.No - 41 WD M 0686 |
| 80 | For outlet 300mm dia TWAD,P.No - 37 WD M 0687 |
| 81 | Supply and delivery of the following dia of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade,Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application withpressure rating PN 10/16. TWAD SoR P.No - 79 |
| 82 | For DI 250mm dia Valve WD M 1202 |
| 83 | For outlet 300mm dia WD M 1203 |
| 84 | Supply & delivery of following DUCTILE IRON SPECIALS AS PER IS 9523/2000 for valve for OHT as per IS standards TWAD SoR P.No - 46 WD M 0779 |
| 85 | Flanged spigot (tail pcs) specials for 250mm dia Valves (Such as Inlet,scour & over flow) |
| 86 | Flanged spigot (tail pcs) specials for 300mm dia outlet Valves |
| 87 | Specials for installation of double flanged pipes |
| 88 | DI 250mm dia Duck foot D/F bend |
| 89 | DI 300mm dia Duck foot D/F bend |
| 90 | DI 250mm dia flanged socket |
| 91 | DI 300mm dia flanged socket |
| 92 | DI 250mm dia 90 degree D/F bend |
| 93 | DI 300mm dia D/F 90 degree bend |
| 94 | Providing pipe connection by lifting pipes and specials in vertical direction and placing the same for required alignment including lifting the pipes and specials in various heights of inlet, outlet, overflow and scour including earthwork excavation conveying the pipe and specials into the trenches, laying to proper grade and alignment cutting, threading and jointing with jointing materials with required specification including labour charges and supply of valves pipes, specials MS Clamps to fix the pipes with the columns including all taxes duties and connected charges etc. complete and taxes duties and connected charges etc. complete and as directed by Engineer incharge.TWAD,P.No - 216 WD W 0753 - WD W 0762 |
| 95 | Vertical laying up to 2m ht. from G.L. |
| 96 | Vertical laying from 2m to 4m. |
| 97 | Vertical laying from 4m to 6m |
| 98 | Vertical laying from 6m to 8m |
| 99 | Vertical laying from 8m to 10m |
| 100 | Vertical laying from 10m to 12 |
| 101 | Vertical laying12,m 14m |
| 102 | Vertical laying14m 16m |
| 103 | Vertical laying16m 18m |
| 104 | Vertical laying18m 19.5 m |
| 105 | Construction of Brick work valve Chamber with M30 Grade concrete . The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of the pit, PCC M10 for Blinding Concrete, Brick work in CM 1:5 and plastering with CM 1:5 - 12mm thick, cost of steel reinforcement fabrication charges, Cover slab with manhole cover etc., and fixing the valves in position inside the pit including laying, jointing of valves, HDPE pipes and specials including the cost of jointing materials such as bolts and nuts RI sheets washers etc., complete and as directed by the Departmental Engineer |
| 106 | Labour charges for painting Name Board Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables etc., complete and as directed by Departmental Officers. TWAD SOR Page No : 215 WD W 0745 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender