Tender For Master Drainage Scheme Faridabad: - Improvement Of Master Storm Water Drainage System In Faridabad Under Fmda (Zone-Ii, Iii And Iv) Faridabad.
Tender Value
67.64 Crore
Estimated cost
Bid Submission
08 Dec 2026
18 days left
EMD
1.35 Crore
Bank guarantee accepted
Document Fee
50000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Faridabad → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Master Drainage Scheme Faridabad: - Improvement Of Master Storm Water Drainage System In Faridabad Under Fmda (Zone-Ii, Iii And Iv) Faridabad.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying of carrier pipe of EWR MS pipe 900 mm i/d,10 mm thick with 2 coats of 1st Class food grade epoxy paints inside and Bituminous on outer side complete as per specification. |
| 2 | Supply installation testing and commissioning of Non Clog HORIZONTAL PUMPS of200cum/hr@18m of 30HP for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Enginee- in-Charge complete in all respect. |
| 3 | P/F of NRV 300mm (C.I)IVC /kriloskar make PN 1.6 complete in all respect as per satisfaction of engineering incharge |
| 4 | Supply, Installation, Testing and Commissioning of 40HP motor starter panel Approved make as per satisfaction of Engineer- in-Charge complete in all respect.(ABB, LandT, Havells,KSb etc.) |
| 5 | Providing and fixing of 300 mm dia D.I D/F manually gear operated sluice valve (IVC make) generally conforming to IS:14846, having body, door, dome, gland in graded ductile iron to IS:1865 Gr. 400/15, four faces and spindle nut of LTB to IS 318 Gr. LTB 2, inside screw non-rising stainless steel AISI-410 spindle, valves suitable for a maximum working pressure of 10 kg/cm² (seat test) and body tested to 15 kg/cm². Flanges drilled to IS 1538 Table 4 and 6 including, carriage, loading and unloading complete in all respect as per satisfaction of the Engineer-in-Charge |
| 6 | Supplying,jointing,aligning,fixing of 300mmdia MS pipe 6mm thick complete asper direction of Engineer-in-Charge |
| 7 | Provide and fixing 400 mm Ductile Iron double flanged manually operated PD type Sluice Valve Generally IS :14846, having body ,door ,dome ,gland in graded cast iron to IS :1865 Gr400/15, four face and spindle nut of LTB to IS 318gr LTB 2, Inside Screw non rising stainless steel AISI-410 spindle ,vcalve suitable for a maximum working pressure of 16kg/cm2 (seat test) and body test to 24kg/cm2. Flanged drilled to IS 1538 table 5and6 valve tested by closed end method only . |
| 8 | Providing and fixing jointing testing commissioning aligning of 400mm Dia MS pipe with 10mm thick food grade epoxy paints complete in all respect and satisfactory of engineer-in-charge. |
| 9 | Analysis of rates providing and fixing of CI NRV IVC/VAG/Kirloskar make of PN 16 rating, including, carriage, loading and unloading and fixing, complete in all respect as per satisfaction of the Engineer-in-Charge. 350 mm i/d |
| 10 | Supplying, erection, testing and commissioning of 13000 LPM x 18 m non-clog Horizontal Centrifugal Pumping set of Impeller CF8M casing CIS210:FG260 of 970RPM, Shaft and sleeves of SS410 as well as grit clearance of 100mm along with suitable motor (415 V plus /- 10%, 50Hz plus /- 5%,LT, TEWC, IP68) complete fitted on base frame. As per specification and relevant codes. Make Kirloskar, Mather and Platt, Jyoti, KSB. |
| 11 | Supplying, erection, testing and commissioning of 13000 Lpm x 15 m Head , 90HP non-clog Submersible Motor pump set of Impeller CF8M casing CIS210:FG260 of 1000 RPM, Shaft and sleeves of SS 410 as well as grit clearance of 100mm along with suitable motor (415 V plus /- 10%, 50Hz plus /- 5%,LT, TEWC, IP68) Duck foot bend, Auto coupling with 10m lifting chain, Guide Rail, PMU with 10 Mtr. Cable with 100 HP Air cooled ( Auto transformer starter) panel with rotary Handle 3 nos. power contactors (Ac3 Duty rated) At 60 Ambient) high end Electronic relay for UV/OV, SPP ELR, PH Failure/unbalance Dry run preventer, level controller A plus ASS, V plus VSS with Selector Switch, KWH Indicators BCH make.. As per specification and relevant codes. |
| 12 | Reverse forward change over for Phase connection system of 1000A Make:- LandT and ABB |
| 13 | SITC of main incomer VCB of 800A, 11 KV rating complete in all respects as per specifications to feed individual Transformers through the VCB - Type: Vacuum Circuit Breaker - Rating: 800A/1000A, 3P, 415V/33kV - Breaking Capacity: 25kA/40kA/50kA - Operating Mechanism: Spring/Solenoid operated - Protection: Overload, Short Circuit, Earth Fault - Features: - Vacuum interrupter- Low maintenance - High reliability - Compact design - Standards: IEC 62271-100, IS 13118 make: Schneider, ABB and CGL |
| 14 | Providing, laying, aligning, and jointing 1200 mm diameter (i/d) M.S. pipe having 12 mm wall thickness, fabricated as per IS:3589 (2001) from Fe-330 grade steel plates conforming to IS:2062 and manufactured by approved makes such as TATA, Jindal, or ESL. The work includes cutting, leveling, grinding, and jointing of the pipes by welding. The internal surface and outer surface of the pipe shall be coated with a minimum 200-micron thick food-grade epoxy lining complete in all respects as per specifications and as per the direction and to the entire satisfaction of the Engineer-in-Charge. |
| 15 | Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of O to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in fal respect. Make:- LandT, SIEMENS, BCH, SCHNEIDER. 140HP Motor. |
| 16 | Hiring of 100 HP DG-mounted non clog dewatering pump set complete with necessary accessories and fittings, including transportation to and from site, loading, unloading, shifting and positioning as required, installation and commissioning, laying, jointing and maintenance of required delivery line, including deployment of trained operator for round-the-clock operation (24 hours) and routine maintenance of pump set and delivery line complete as directed by the Engineer-in-Charge, excluding cost of diesel/fuel. |
| 17 | Supplying, erection, testing and commissioning of 20000 Lpm x 15 m Head , 100 HP non-clog Submersible Motor pump set of Impeller CF8M casing CIS210:FG260 of 1000 RPM, Shaft and sleeves of SS 410 as well as grit clearance of 100mm along with suitable motor (415 V plus /- 10%, 50Hz plus /- 5%,LT, TEWC, IP68) Duck foot bend, Auto coupling with 10m lifting chain, Guide Rail, PMU with 10 Metre. Cable with 125 HP Air cooled ( Auto transformer starter) panel with rotary Handle 3 nos. power contactors (Ac3 Duty rated) At 60 Ambient) high end Electronic relay for UV/OV, SPP ELR, PH Failure/unbalance Dry run preventer, level controller A plus ASS, V plus VSS with Selector Switch, KWH Indicators BCH make.. As per specification and relevant codes. |
| 18 | Supplying, erection, testing and commissioning of 20000 Lpm x 18 m Head , 100 HP non-clog Horizontal Centrifugal Motor pump set of Impeller CF8M casing CIS210:FG260 of 1000 RPM, Shaft and sleeves of SS 410 as well as grit clearance of 100mm along with suitable motor (415 V plus /- 10%, 50Hz plus /- 5%,LT, TEWC, IP68) Duck foot bend, Auto coupling with 10m lifting chain, Guide Rail, PMU with 10 METRE. Cable with 125 HP Air cooled ( Auto transformer starter) panel with rotary Handle 3 nos. power contactors (Ac3 Duty rated) At 60 Ambient) high end Electronic relay for UV/OV, SPP ELR, PH Failure/unbalance Dry run preventer, level controller A plus ASS, V plus VSS with Selector Switch, KWH Indicators BCH make.. As per specification and relevant codes. |
| 19 | 35 sqmm copper cable 4 core of make:- Polycab, Havells and KEI etc. |
| 20 | 1000A ACB with enclosure and all related accessories. |
| 21 | 1250A ACB with enclosure and all related accessories. |
| 22 | HSR Items- Master Drainage Scheme Faridabad: - Improvement of Master Storm Water Drainage System in Faridabad under FMDA (Zone-II, III and IV) Faridabad. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender