Power Boards / Undertakings / PSU Closing in 26 days TDR #58566259

Tender For Electrification Package For Blocks 145,122,101,113,119B, 111,107C 135A Etc For Inrp Site, Tarapur

Issued by Boards / Undertakings / PSU · Palghar, Maharashtra
Tender Value
23.37 Crore
Estimated cost
Bid Submission
14 Dec 2026
26 days left
EMD
33.37 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Palghar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrification Package For Blocks 145,122,101,113,119B, 111,107C 135A Etc For Inrp Site, Tarapur

BOQ

Name of Work:- Electrification Package for Blocks 145,122,101,113,119B, 111,107C 135A etc for INRP site, Tarapur
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door, with R Y B Phase LED indication and MCB position indication through glass front, IP-54, Prewired with HFFR copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade, pre-galvanised G.I. sheet steel, suitable for flush/Surface mount in brick wall complete with appropriate rating earth and neutral bar, din bar, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, etc. as per tender technical specifications.
24 way having 1 no. main incomer of In = 16 A TPN MCB, Ics=10kA, Type C with 1 no. In = 16 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of In =6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
34 way having 1 no. main incomer of In = 25 A TPN MCB, Ics=10kA, Type C with 1 no. In = 25 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
44 way having 1 no. main incomer of In = 32 A TPN MCB, Ics=10kA, Type C with 1 no. In = 32 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
56 way having 1 no. main incomer of In = 25 A TPN MCB, Ics=10kA, Type C with 1 no. In = 25 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
66 way having 1 no. main incomer of In = 32 A TPN MCB, Ics=10kA, Type C with 1 no. In = 32 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
76 way having 1 no. main incomer of In = 40 A TPN MCB, Ics=10kA, Type C with 1 no. In = 40 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
86 way having 1 no. main incomer of In = 16 A TPN MCB, Ics=10kA, Type C with 1 no. In = 16 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of In =6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
98 way having 1 no. main incomer of In = 25 A TPN MCB, Ics=10kA, Type C with 1 no. In = 25 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
108 way having 1 no. main incomer of In = 40 A TPN MCB, Ics=10kA, Type C with 1 no. In = 40 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
118 way, TPN MCB DB with Incomer of 16A, Isc=10kA, Type C, (100mA) 16A DP RCBO for each phase and 24 Nos of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
128 way having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 1 no. of 32A, Isc=10kA, DP, MCB and RCCB(100mA) as incomer for each phase and 24nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications.
138 way having 1 no. main incomer of 63A TPN MCB, Isc=10kA, Type C with 1 no. of 63A, Isc=10kA, DP, MCB and RCCB(100mA) as incomer for each phase and 24nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications.
1412 way having 1 no. main incomer of In = 40 A TPN MCB, Ics=10kA, Type C with 1 no. In = 40 A, Ics=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of In =16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
1510way having 1 no. main incomer of 63A TPN MCB, Isc=10kA, Type C with 1 nos. of 63A, Isc=10kA, DP, MCB and RCCB (100mA) as incomer for each phase and 30 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications.
1610way having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 1 nos. of 32A, Isc=10kA, DP, MCB and RCCB(100mA) as incomer for each phase and 30 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications.
1710 way having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 1 no. of 25A, Isc=10kA, DP, MCB and RCCB (100mA) as incomer for each phase and 30 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity .
1812way having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 1 nos. of 32A, Isc=10kA, DP, MCB and RCCB (100mA) as incomer for each phase and 36nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications.
1912way having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 1 nos. of 32A, Isc=10kA, DP, MCB and RCCB (100mA) as incomer for each phase and 36nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications.
20Supply, Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, with Phase and MCB position indication through glass front, Pre-wired with HFFR copper wires, IP-54, MCB Distribution Board fabricated out of 2mm thick Pre Galvanised G. I sheet steel, powder coated with RAL7035 shade, suitable for flush/Surface mount in brick wall complete with appropriate rating earth and neutral bar, din bar, brass earthing studs, phase distribution drawing, danger board, name plate, earth bar, din bar for MCB mounting, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, check-nuts etc. as required as per tender technical specifications.
2112 way having 1 no. main incomer of In = 63A DP MCB, Ics=10kA, Type C and 12 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
2212 way having 1 no. main incomer of In = 40A DP MCB, Ics=10kA, Type C and 12 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
2312 way having 1 no. main incomer of In = 16A DP MCB, Ics=10kA, Type C and 12 nos. outgoing of In = 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
2410 way having 1 no. main incomer of In = 25A DP MCB, Ics=10kA, Type C and 10 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
2510 way having 1 no. main incomer of In = 16A DP MCB, Ics=10kA, Type C and 10 nos. outgoing of In = 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
268 way having 1 no. main incomer of In = 63A DP MCB, Ics=10kA, Type C and 8 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
278 way having 1 no. main incomer of In = 40A DP MCB, Ics=10kA, Type C and 8 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
288 way having 1 no. main incomer of In = 32A DP MCB (100mA), Ics=10kA, Type C and 8 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
298 way having 1 no. main incomer of In = 25A DP MCB, Ics=10kA, Type C and 8 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
308 way having 1 no. main incomer of In = 16A DP MCB, Ics=10kA, Type C and 10 nos. outgoing of In = 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
316 way having 1 no. main incomer of In = 40 A DP MCB, Ics=10kA, Type C and 6 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
326 way having 1 no. main incomer of In = 32A DP MCB (100mA), Ics=10kA, Type C and 6 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
336 way having 1 no. main incomer of In = 25A DP MCB, Ics=10kA, Type C and 6 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
346 way having 1 no. main incomer of In = 25A DP MCB (100mA), Ics=10kA, Type C and 6 nos. outgoing of In = 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
356 way having 1 no. main incomer of In = 16 A DP MCB, Ics=10kA, Type C and 6 nos. outgoing of In = 10 A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
366 way having 1 no. main incomer of In = 16 A DP MCB, Ics=10kA, Type C and 6 nos. outgoing of In = 6 A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
374 way having 1 no. main incomer of In = 32 A DP MCB (100mA), Ics=10kA, Type C and 4 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
384 way having 1 no. main incomer of In = 25A DP MCB, Ics=10kA, Type C and 4 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
394 way having 1 no. main incomer of In = 16A DP MCB, Ics=10kA, Type C and 4 nos. outgoing of In = 10A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
404 way having 1 no. main incomer of In = 25 A DP MCB (100mA), Ics=10kA, Type C and 4 nos. outgoing of In = 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
414 way having 1 no. main incomer of In = 16A DP MCB, Ics=10kA, Type C and 4 nos. outgoing of In = 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
424 way having 1 no. main incomer of In = 40 A DP MCB, Ics=10kA, Type C and 4 nos. outgoing of In = 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA rated service breaking capacity and as per tender technical specifications.
43DC DB
444 way having 1 no. main incomer of In = 16 A DP DC MCB, and 4 nos. outgoing of In = 6A DP DC MCB suitable for 110V DC and as per tender technical specifications.
454 way having 1 no. main incomer of In = 25 A DP DC MCB, and 4 nos. outgoing of In = 10A DP DC MCB suitable for 110V DC and as per tender technical specifications.
468 way having 1 no. main incomer of In = 10 A DP DC MCB, and 8 nos. outgoing of In = 6A DP DC MCB as per tender technical specifications.
47Supply, installation, testing and commissioning of 40 W Surface Mounted LED Batten Luminaire, 1200 mm long, extruded aluminium housing with opal polycarbonate diffuser, integrated constant-current LED driver, minimum efficacy 110 lm/W, luminous flux not less than 4400 lumens, CRI ≥80, PF ≥0.95, THD ≤10%, surge protection minimum 2.5 kV, operating on 220–240 V AC, complete with mounting accessories.
48SITC of LED surface mount downlighter light complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, Surface mounted with a nominal system lumen output of equal or more than 2400lumens and a minimum system efficacyof 100lm/W.The luminaire shall have a rated system lifetime of 25,000 burning hours. The luminaire should have a CCT of 5700K,Initial chromaticity <5 and CRI > 80.The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof siliconerubber ring. The total power consumption should not exceed 24W (including driver).
49Supply of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED Highbay with a nominal system lumen output of 18000 lumens and a minimum system efficacy of not less than 140 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a CCT of 5700K and CRI > 70 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 130W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
50SITC of LED Surface mount Periphery light complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, Surface mounted with a nominal system lumen output of 4200 lumens and a minimum system efficacyof 120lm/W.The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT of 5700K, and CRI > 70.The luminaire shall meet IP66 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 36W (including driver).
51Supply, installation, testing and commissioning of 36 W LED Flameproof Tube Light, suitable for hazardous locations, Ex db eb IIC T6 Gb, Zone 1 & Zone 2, IP66, die-cast aluminium housing with toughened glass diffuser, stainless steel fasteners, integral constant-current LED driver, minimum efficacy 110 lm/W, complete with Ex-certified cable gland, mounting accessories and all hardware.
52SITC of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W per tube. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver).
53SITC of LED recess mount 2'x2' grid light complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, Recess/Surface mounted with a nominal system lumen output of 4200lumens and a minimum system efficacyof 120lm/W.The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50 @ 50k hrs. The luminaire should have a CCT of 5700K,Initial chromaticity <5 and CRI > 80.The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof siliconerubber ring. The total power consumption should not exceed 36W (including driver).
54SITC of 230V light fitting, LED Bulkhead type with a nominal system lumen output of 780 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 5700K and CRI > 80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95 , L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box, . . The luminaire housing should have made of High pressure die cast Aluminium with high quality PMMA diffuser. The total power consumption should not exceed 6.5 W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
55SITC of light fitting, LED Bulkhead type with a nominal system lumen output of 1440 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 5700K and CRI > 80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95 , L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box, . The luminaire housing should have made of High pressure die cast Aluminium with high quality PMMA diffuser and suitable for 110V DC operation. The total power consumption should not exceed 12 W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
56SITC of light fitting, LED Bulkhead type with a nominal system lumen output of 1200 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 5700K and CRI > 80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95 , L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box, . . The luminaire housing should have made of High pressure die cast Aluminium with high quality PMMA diffuser. The total power consumption should not exceed 10W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
57SITC of \\"FLAMEPROOF\\" LED Bulkhead type with a nominal system lumen output of 1200 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 5700K and CRI > 80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95 , L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box, . . The luminaire housing should have made of High pressure die cast Aluminium with high quality PMMA diffuser. The total power consumption should not exceed 10W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications
58Supply, installation, testing and commissioning of 2 × 8 W LED Flame Proof Luminaire, suitable for Zone 1 & Zone 2 hazardous areas, die-cast aluminium housing with toughened glass diffuser, IP65/IP66 protection, , complete with LED driver, Ex-certified cable gland, mounting accessories and all necessary hardware.
59SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories,flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs,LED decorative type sleek mirrorWall light with high diffuser of 14W with nominal system output of 1400 lumens and should have a CCT of 3000K and CRI>80.The Luminaire should made of metal with high quality PMMA diffuser.The total power consumption should not exceed 14W (including driver).
60SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED Highbay with a nominal system lumen output of 12500 lumens and a minimum system efficacy of not less than 140 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a CCT of 6500K and CRI > 80 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 90W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
61SITC of LED surfcae mount 2'x2' grid light complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, Surface mounted with a nominal system lumen output of 4200lumens and a minimum system efficacyof 120lm/W.The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50 @ 50k hrs. The luminaire should have a CCT of 5700K,Initial chromaticity <5 and CRI > 80.The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof siliconerubber ring. The total power consumption should not exceed 36W (including driver).
62SITC of LED integral driver Flood light with a nominal system lumen output of 18000 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 150W (including driver).
63SITC of LED integral driver Bollard/ Landscape light with a nominal system lumen output of 600lumens and a minimum system efficacy of 75lumen/watt. The luminaire should have a CCT of 5700K and a CRI>80. The luminaire shall meet IP65 rating with IK07, THD<20% and PF>0.95. The luminaire housing should be made of aluminium/ GI with Black powder coating and polycarbonate diffuser. The total power consumption should not exceed 8W (including BIS compliant driver). Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. The light fitting shall be supplied with SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch PVC terminal box and other requirements as per tender technical specifications.
64SITC of LED street light fitting of not more than 40W having System Efficacy >120lm/W, system output >=4800 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 6500K, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Driver shall have 6KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. The light fitting shall be supplied with SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch PVC terminal box and other requirements as per tender technical specifications.
65SITC of LED integral driver 100W flood light Industrial Batten Surface mounted with a nominal system lumen output of 12500 lumens and a minimum system efficacy of 125 lumen/watt. The luminaire should have cool white colour temperature 6500K and a CRI>80. The luminaire shall meet IP66 rating with THD<10% & PF>0.9. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 104 W (including driver)
66SITC of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver).
67SITC of Black painted Extruded aluminium housing single sided 8W LED signage exit light,Red LED’s mounted inside the housing,Laser engraved Signage matter on Single / Double Acrylic sheet fixed on one side along with Ni-Cd Battery back up to 2 hrs. (Charged up to 8 - 10 Hrs),Mounting strings provided for pendent mounting ,Operating Voltage 150-280V AC and Ingress protection – IP42
68SITC of LED Highbay with a nominal system lumen output of 19500 lumens and a minimum system efficacy of 130 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI > 80 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire should be tested from NABL accredated LAB and should have proper IES file. The luminaire housing should made of High Pressure die cast Aluminium with narrow beam optics and having gasket of heat proof siliconerubber ring. The total power consumption should not exceed 157W (including driver)
69SITC of 150W SON HPSV lighting fixture complete with SON-T 150W high pressure sodium lamp, high efficiency aluminium reflector, die-cast aluminium housing, toughened glass cover, non- integral control gear comprising ballast, ignitor and capacitor, IP65/IP66 protection, suitable for 230V AC 50Hz supply, complete with mounting accessories, testing and commissioning.
70SITC of 70W SON HPSV lighting fixture complete with 70W High Pressure Sodium Vapour Lamp, non-integral control gear comprising ballast, ignitor and capacitor, die-cast aluminium housing, high efficiency aluminium reflector, toughened glass cover, IP65/IP66 protection, suitable for 230/240V AC, 50Hz supply, pole arm mounting arrangement, including all accessories, testing and commissioning complete
71Type B Low intensity LED based aviation light as per the Civil Aviation requirement (ICAO) as per tender specification.
72SITC of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver).
73SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, LED medium bay with a nominal system lumen output of 10400 lumens and a minimum system efficacy of not less than 130 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT of 5700K and CRI > 70 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire should be tested from NABL accredated LAB and should have proper IES file. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 80W (including driver).
74SITC of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver).
75SITC of LED Recess mount downlight light complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs,Recess mounted with a nominal system lumen output of 2000 lumens and a minimum system efficacyof 110lm/W.The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT of 6500K,and SDCM <5 and CRI > 80.The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof siliconerubber ring. The total power consumption should not exceed 18W (including driver)
76SITC of LED 4ft Slim Batten with a nominal system lumen output of 2100 lumens and a minimum system efficacy of 115 lm/W.The luminaire should have CCT 6500K and CRI > 80. The luminaire shall meet IP20 protection rating with THD < 10% and PF > 0.9. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 19W (including driver)
77SITC of 19 Watt LED Batten having system efficacy 115 lm/W, system output 2100 lumens, THD < 10%, Power Factor > 0.9, CRI > 80, CCT 6500, CRCA Powdered coated housing and IP65 protection
78Supply, installation, testing and commissioning of 30W LED recessed downlighter complete with high efficiency SMD LED module, integral constant current driver, die-cast aluminium housing, high efficiency reflector and optical diffuser, having minimum system efficacy of 110 lm/W and minimum lumen output of 3300 lumens, CRI ≥80, PF ≥0.90, surge protection minimum 4kV, suitable for 220–240V AC, 50Hz supply, recessed false ceiling mounting arrangement, complete with all accessories, fixing hardware and commissioning.
79SITC of LED Recessed 1ft x 4ft Troffer Luminaire with a nomial system lumen output of 3200 lumens and a minimum system efficacy of 90 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF >0.9. The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser. The total power consumption should not exceed 35W (including driver)
80Supply, installation, testing and commissioning of 300mm diameter round surface mounted LED fixture complete with high efficiency SMD LED module and integral constant current driver, having minimum system efficacy of 110 lm/W and minimum lumen output of 1320 lumens, CRI ≥80, PF ≥0.90, wide beam optical diffuser, suitable for 220–240V AC, 50Hz supply, with polycarbonate/aluminium housing, opal diffuser, including mounting accessories, fixing hardware and commissioning complete.
81Supply and Installation of Single phase heavy duty exhaust fan of sweep 300 mm with FRP duct suitable for domestic application
82Supply
83Installation, Testing and Commissioning
84Supply, Installation, Testing and Commissioning of new energy efficient High Grade ABS Basic Hand Dryers, wall mounted, 1800Watt or above, Touch free Infra-red Sensor activation, AC220-240V, 50/60Hz and as per tender technical specifications.
85Supply and laying of following size earthing conductor at 1000 mm below ground level including excavation, brazing, connection to earth pits, refilling the trench etc. as required.
8695 sq. mm stranded bare tinned copper conductor
87Supply and laying of 125 sq mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
88Supply and laying of 70 sq. mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
89Supply and laying of 35 sq mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
90Supply and laying of 25 sq. mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
91Supply and laying of 16 sq. mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
92Supply and laying of 6 sq. mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
93Supply and laying of 4 sq. mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
94Supply and laying of 2.5 sq. mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
95Supply and laying of 2 x 10 sq. mm Cu PVC insulated earthing conductor in 25mm HDPE pipe including underground laying with excavation/ clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.(supply of HDPE pipe included in Contractor's scope)
96Supply and laying of 10 sq mm stranded bare tinned copper conductor including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge.
97SITC of 63A rated welding receptacles.
98Supply and laying of 14 SWG tinned solid copper conductor throughout along the conduit including fixing with ties, brazing etc as required.
99Supply and laying of 25mm x 3mm tinned copper flat
100Supply and installation of Busbar Insulator of size M8 x 40mm, MOC: Epoxy as per tender specification.
101Supply and installation of Copper lug suitable for 70 Sq.mm stranded tinned copper conductor
102Supply and installation of Copper lug suitable for 95 Sq.mm stranded tinned copper conductor
103Supply and installation of Copper lug suitable for 10 Sq.mm stranded tinned copper conductor
104Supply and installation of Copper lug suitable for 35 Sq.mm stranded tinned copper conductor
105Supply and installation of Copper lug suitable for 125 Sq.mm stranded tinned copper conductor
106Supply and installation of M10 brass nut bolt, 3/4\\" long suitable for 10mm threaded hole for making connection to earth pad.
107Supply and installation GI C Clamp of size 25*3 mm ,length 200mm having suitable size of hole for fixing of cu strip.
108Supply and fixing of vertical air termination made up of 20 mm dia., 1 mtr. long copper rod attached to 50 mm dia. Copper sphere having drilled and tapped holes for fixing 5 nos. of 150 mm long spikes and square copper base plate of 150 mm length and 10 mm thickness as per latest IS & technical specification and approved drawing.
109Supply and erection of plate earth electrode pit comprising of 600 X 600 X 3.15mm thick tinned copper earth plate, 50mm dia class B watering pipe of 2.7 mtr length, funnel, earth conductor connection, test link, concrete inspection pit with GI cover having lifting arrangement, etc. as perIS:3043-2001.
110Supply and erection of rod earth electrode pit comprised of 25mm dia. and 3mtr long tinnedcopper earth rod, connection of 2 x 95 sq mm conductor, 50mm dia class B watering pipe of 3 mtr length, funnel, earth conductor connection clamp, test link, concrete inspection pit with GI coverhaving lifting arrangement, etc. as per IS:3043-2001.
111Supply and installation of test link box and termination of earthing conductor from earthing protection system and earth pit and should consist of 2mm thick powder coated pre-galvanised G.I. weather proof sheet enclosure with cover, having 2 parallel paths of 30 mm x 6mm copper strip link, teflon sealing after connection, earthing stud, suitable for connecting of 8 nos. of 95sqmm earthing conductors etc and as per tender technical specifications.
112Supply and installation of test link box and termination of earthing conductor from Lightning protection system and earth pit and should consist of 2mm thick powder coated pre-galvanised G.I. weather proof sheet enclosure with cover, having 30 mm x 6mm copper strip link, teflon sealing after connection, earthing stud, suitable for connecting of Cu strip and 2 nos. of 95sqmm earthing conductors etc and as per tender technical specifications
113Supply, Installation, Testing and Commissioning of the following Modular switches in the existing recess mounted GI box as per Technical specifications.
114Supply of 1 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
115Installation, Testing and Commissioning of 1 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
116Supply of 2 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
117Installation, Testing and Commissioning of 2 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
118Supply of 3 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
119Installation, Testing and Commissioning of 3 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
120Supply of 4 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
121Installation, Testing and Commissioning of 4 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
122Supply of 5 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
123Installation, Testing and Commissioning of 5 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification.
124Supply & Installation of 2 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 2nos. of plug tops and suitable mounting arrangements as per technical specification.
125Supply & Installation of 1 nos. of 6/16A, Single phase Modular socket with 16A switch for socket and heavy duty Polycarbonate face plate, 1no. Of plug top and suitable mounting arrangements as per technical specification.
126Supply and Installation of the following modular heavy duty polycarbonate box , Fire Retardant, ISI marked switches, sockets, plug tops, PVC Box and combined face plates as per technical specification.
1274-modular PVC box including cover plate, face plate with 2 nos. of RJ11(4 Pin) connector with shutter telephone socket and 2 nos of RJ45 socket (UTP/STP) with shutter and connector.
1282-modular PVC box including cover plate with face plate with 2 nos of RJ45 socket (UTP/STP) with shutter and connector.
129Supply & Installation of 12 Way modular domestic type Switch box with cover plate, 4 nos of switches of rating 6 Amp and 4 no of sockets ( 6/20 Amps ), suitable for surface mounting as per attached technicalspecification
130Supply and Installation of 6 Way modular domestic type Switch box with cover plate, 2 nos of switches of rating 6 Amp and 2 no of sockets ( 6/20 Amps ), suitable for surface mounting as per attached technical specification.
1313 nos. of 1M 16Amp switch, 3 nos. of 6A/16A 2M Shuttered socket (Heavy Duty) , suitable 9M heavy duty polycarbonate box, fire Retardant combined face plate and 3 nos. of 2M Plug Top
1322 nos. of 1M 16Amp switch, 2 nos. of 6A/16A 2M Shuttered socket (Heavy Duty) , suitable 6M heavy duty polycarbonate box, fire Retardant combined face plate and 2 nos. of 2M Plug Top
1331 no. of 6A/16A 2M Shuttered socket (Heavy Duty) and 1 nos. of 1M 16Amp switch suitable 3M heavy duty polycarbonate box, fire Retardant combined face plate and 1 no. of 2M Plug Top
1341 no. of 6A/16A 2M Shuttered socket (Heavy Duty) , suitable 2M heavy duty polycarbonate box, fire Retardant combined face plate and 1 no. of 2M Plug Top
1356 nos. of 1M 6Amp switch and suitable 6M heavy duty polycarbonate box, fire Retardant combined face plate
1364 nos. of 1M 6Amp switch and suitable 4M heavy duty polycarbonate box, fire Retardant combined face plate
1373 nos. of 1M 6Amp switch and suitable 3M heavy duty polycarbonate box , fire Retardant combined face plate
1382 nos. of 1M 6Amp switch and suitable 2M heavy duty polycarbonate box, fire Retardant combined face plate
1391 nos. of 1M 6Amp switch and suitable 1M heavy duty polycarbonate box , fire Retardant combined face plate
140SITC of single un-switched weatherproof socket outlet, 6A, 230V AC, suitable for outdoor application, complete with weatherproof enclosure, shuttered socket, 2M plug top, 3pin configuration, IP65 protection, suitable mounting arrangement, terminals and all necessary accessories as per tender technical specification.
141Supply and fixing of heavy duty Class-B Galvanised steel (G.I.) ERW conduit pipe of following sizes along with all accessories such as bends, junction box, socket, check nut, etc. including making threads, removing burrs, connection of accessories, cleating with heavy duty GI spacer saddles or suit to site clamps on RCC wall, column, steel structural, etc. as required under the instruction of Engineer-in-incharge. Surface type junction box shall be provided.
14225 MM
14340 MM
144Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100 V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130 / 1984 as per technical specification
1451.5 Sq. mm
1462.5 Sq. mm
147Installation/drawing through concealled/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100 V as per the IS 17048 : 2018. As per conductor class 2 of IS: 8130 / 1984 as per technical specification
1481.5 Sq. mm
1492.5 Sq. mm
150Supply and Installation of Casing and Capping of Flame Retardant (FR) PVC material , Ivory Colour, Unplasticised formulation for prolong storage or usage, double lock, ISI Marked as per IS 14927, Highly durability, Resistance to oil and grease of following sizes as required
151Size 25mm × 16 mm
152Size 38 mm × 16 mm
153Size 50 mm × 16 mm
154Size 38 mm × 25 mm
155Size 50 mm × 25 mm
156Size 50 mm × 50 mm
157Providing and fabrication of structural steel (IS 2062 E250 BR) supports, bracket etc. with the usage of suitable size angle, channel, strip, plate, pipe, including cutting, welding, fabrication, painting etc. as per tender technical specifications
158Supply and Installation of flexible Galvanized steel PVC coated conduit pipe of size 26mm including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification.
159Supply and Installation of flexible Galvanized steel PVC coated conduit pipe of size 50mm including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification.
160Supply of required material and making of straight exothermic braze joints of copper conductors (95 sqmm) as per technical specification.
161Supply of required material and making of 'T' type exothermic braze joints of copper conductors (95 sqmm) as per technical specification.
162Supply and Installation of GI Anchor Fastner of size M8x80 MM by drilling through concrete block as per site requirement for fixing plate Eps or other structures as per the tender specification.
163Supply and installation of GI Anchor Fastner of size M12x130 MM
164Supply and Installation of 2mm thick pre-galvanished GI sheet with powder coating including marking,cutting (as per site requirement)and erection on top of JB openings on wall and ceiling at approximate height of 7 mtrs (in size of 150mm ×150mm).
165Supply and Installation of Single phase heavy duty exhaust fan of sweep 200 mm with FRP duct suitable for domestic application.
166Supply
167Installation, Testing and Commissioning
168Supply, Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor with inbuilt or external power pack and auxiliary relay having min 15 mtr sensing range in 180 deg orientation and time delay ranges from 30 sec to 30 min and should have output relay capacity of 1000 W (for LED lighting fixtures)
169Supply, Installation, Testing and Commissioning of Occupancy sensor bypass switch box having 3 pole rotary switch fixed on GI enclosure with cover
170SITC of Junction box / Cable pull box shall be weather proof type, size 100mm x 100mm x 50mm fabricated out of 2mm thick GI sheet, cable gland plate at bottom, punched hole for conduit entry on all sides, suitable to terminate 2 Nos of 3 core x 2.5 sqmm Cu conductor, 8 Nos of terminals, etc as required
171Making the opening in brick masonry for door / window / clear story opening including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface including disposal of mulba/ rubbish to the nearest dumping ground.
172Core cutting of 300mm thick RCC slab and hole dia 100mm
173Supply and Installation of (M.O.C: Pre-Galvanized G.I sheet steel) powder coated wall mounted PA Main Junction Box (PJB) made of 14SWG, punched hole for conduit entry on all sides and suitable for incoming cable of size 100 pair x 1.5 sq.mm. armoured twisted pair cable. The junction box shall consist of 200 nos. terminals suitable for 1.5 sq.mm. as per the technical specification.
174Supply & installation of wall mounted PA Main Junction Box (PJB) fabricated out of 2 mm thick Pregalvanised GI sheet Powder coated, punched hole for conduit entry on all sides and suitable for incoming cable of size 50 pair x 1.5 sq.mm. armoured twisted pair cable. The junction box shall consist of 100 nos. terminals suitable for 1.5 sq.mm.
175Supply and Installation of (M.O.C: Pre-Galvanized G.I sheet steel) powder coated wall mounted PA Main Junction Box (PJB) made of 14SWG, punched hole for conduit entry on all sides and suitable for incoming cable of size 20 pair x 1.5 sq.mm. armoured twisted pair cable. The junction box shall consist of 40 nos. terminals suitable for 1.5 sq.mm. as per the technical specification.
176Supply & installation of wall mounted PA Main Junction Box (PJB) fabricated out of 2 mm thick Pregalvanised GI sheet Powder coated, punched hole for conduit entry on all sides and suitable for incoming cable of size 10 pair x 1.5 sq.mm. armoured twisted pair cable. The junction box shall consist of 20 nos. terminals suitable for 1.5 sq.mm.
177Supply & installation of wall mounted PA Main Junction Box (PJB) fabricated out of 2 mm thick Pregalvanised GI sheet Powder coated, punched hole for conduit entry on all sides and suitable for incoming cable of size 5 pair x 1.5 sq.mm. armoured twisted pair cable. The junction box shall consist of 10 nos. terminals suitable for 1.5 sq.mm.
178Supply, drawing/ laying & termination of 25 pair, 1.5 Sq. mm, Flexible, Overall Aluminum Mylar screen with drain wire, Copper, Multistranded conductor, unamoured, FRLS PVC Sheathed (Inner and Outer) as per attached specifications
179Supply, drawing / laying & termination of 10 pair, 1.5 Sqmm, Flexible, overall Aluminum Mylar screen with drain wire, Copper, Multistranded conductor, Armoured, FRLS PVC Sheathed (Inner and Outer) as per attached technical specifications
180Supply, drawing/ laying & termination of 1 pair, 1.5 Sq. mm, Flexible, Overall Aluminum Mylar screen with drain wire, Copper, Multistranded conductor, unamoured, FRLS PVC Sheathed (Inner and Outer) as per attached specifications
181Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 1500+ 1500 pairs of Telephone cable as per the technical specification.
182Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 200 + 200pairs of Telephone cable as per the technical specification.
183Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 100 + 100pairs of Telephone cable as per the technical specification.
184Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 50 + 50pairs of Telephone cable as per the technical specification.
185Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 300 + 300pairs of Telephone cable as per the technical specification.
186Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 20 + 20pairs of Telephone cable as per the technical specification.
187Supply and Laying of 100 Pair, 0.5 mm dia copper conductor, jelly filled armoured telephone cable
188Supply and Laying of 50 Pair, 0.5 mm dia copper conductor, jelly filled armoured telephone cable
189Supply and Laying of 20 Pair, 0.5 mm dia copper conductor, jelly filled armoured telephone cable
190Supply and drawing of 2 Pair 0.5 mm copper conductor Telephone cable from EPABX Main JB upto RJ-11 socket unit of individual telephone instrument through concealed conduit including end termination in RJ-11 socket units.
191Supply and Installation of 2Way heavy duty polycarbonate, Fire Retardant, ISI marked Front plate with modular type Four Pin RJ-11 socket unit (with modular PVC box)
192Supply & installation of wall mounted Junction box for PA speakers fabricated out of 2 mm thick Pre Galvanised GI sheet steel Powder coated, punched hole for conduit entry on all sides and having 4 way 4 nos. of terminals, suitable for terminating 1.5 sq. mm PA cable.
193Supply installation of wall mount and desktope type analog telephone instrument with alphabet and numeriucal caller ID facility.
194Supply of 23AWG CAT6 Armoured UTP cable LSZH type
195Laying of 23AWG CAT6 Armoured UTP cable LSZH type
196Supply of 23AWG CAT6 unarmoured UTP cable LSZH type
197laying of 23AWG CAT6 unarmoured UTP cable LSZH type
198Supply of 52-port (48x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories
199Installation of 52-port (48x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories
200Supply of 28-port (24x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories
201Installation, testing, commissioning of of 28-port (24x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories
202Supply of Industrial grade 10-port (8x1 Gbps RJ-45 Copper port, 2x1/10 Gbps SFP port) POE+ layer-2 ethernet network switch along with power supply arrangement and mounting accessories
203Installation, testing, commissioning of Industrial grade 10-port (8x1 Gbps RJ-45 Copper port, 2x1/10 Gbps SFP port) POE+ layer-2 ethernet network switch along with power supply arrangement and mounting accessories
204Supply of 24-Port CAT6 Patch panel of 1U size suitable for 19\\" rack fully loaded with all wiring support accessories inclduing RJ45 connectors.
205Installation of 24-Port CAT6 Patch panel of 1U size suitable for 19\\" rack fully loaded with all wiring support accessories inclduing RJ45 connectors.
206Supply of Fully Loaded drawout type, LC type 24-port Fiber Distribution (LIU)System of 1U size suitable for mounting in 19\\" rack.
207Installation of Fully Loaded drawout type, LC type 24-port Fiber Distribution (LIU)System of 1U size suitable for mounting in 19\\" rack.
208Supply of 1Gbps Single Mode (SFP) 1000BASE-LX LC transreciever Module compatible with supplied ethernet switches.
209Installationof 1Gbps Single Mode (SFP) 1000BASE-LX LC transreciever Module compatible with supplied ethernet switches.
210Supply of 24-core Armoured Single Mode (9/125 um) Multi-tube loosely buffered Fiber optic cable
211Laying of 24-core Armoured Single Mode (9/125 um) Multi-tube loosely buffered Fiber optic cable through HDPE pipe.
212Supply of HDPE pipe 40 mm along with all accessories like bends, couplers etc, fitting, cutting and jointing etc.
213Laying of HDPE pipe 40 mm along with all accessories like bends, couplers etc, fitting, cutting and jointing etc.
214CAT6 Patch cords, 1 meter
215Supply
216Installation
217CAT6 Patch cords, 2 meter
218Supply
219Installation
220LC-LC SM Duplex Fiber Patchcords 2 meter length.
221Supply
222Installation
223LC-LC SM Duplex Fiber Patchcords 5 meter length.
224Supply
225Installation
226LC-LC SM Duplex Fiber Patchcords 10 meter length.
227Supply
228Installation
229LC-LC SM Duplex Fiber Patchcords 15 meter length.
230Supply
231Installation
232Fiber optic Splicing and Termination of Connectors
233SITC of Indoor IP based 2 MP vandal resistant(IK10) Dome IR camera(POE) along with mounting accessories and junction box
234SITC of Outdoor IP based 5 MP Motorised Focused Zoom(MFZ) varifocal IR Bullet camera(POE) along with mounting accessories and outdoor weatherproof junction box
235SITC of Outdoor IP based 2 MP WDR IR PTZ(Pan-tilt-Zoom) POE camera (25x or better optical zoom) with mounting accessories and outdoor weatherproof junction box
236Supply installation of CCTV 55 inch professional display with necessary wall mounting accessories
237Supply installation of HDMI/Display port adaptor with the fiber optic HDMI cable 20 meter length for interface between display and NVR system
238Supply of 32-Channel NVR with 1080p resolution support and H.265 or better decoding with minimum 20 TB storage capacity and Supply of Central Video management software along with license for integrated view of NVRs
239Installation, commissioning of 32-Channel NVR with 1080p resolution support and H.265 or better decoding with minimum 20 TB storage capacity along with configuration of Central Video management software along with license for integrated view of NVRs
240Supply & Installation of 10TB Surveillance grade hard disks compatible with above surveillance system
241Supply 9U wall mount network rack of 19\\" size side openable with minimum 2 cooling fans(90 cfm), 5 socket PDU, 2 cable manager and fully loaded with all accessories
242Installation, testing, commissioning of 9U wall mount network rack of 19\\" size side openable with minimum 2 cooling fans(90 cfm), 5 socket PDU, 2 cable manager and fully loaded with all accessories
243Supply of 9U outdoor IP66 network rack of 19\\" size fully loaded with all accessories
244Installation, testing, commissioning of 9U outdoor IP66 network rack of 19\\" size fully loaded with all accessories
245Supply of 32U Floor standing rack fully loaded with all accessories
246Installation, testing, commissioning of 32U Floor standing rack fully loaded with all accessories
247Supply of 24-core armoured cable OFC Splicing jointing kit for cable
248Installation of 24-core armoured cable OFC Splicing jointing kit for cable along with OTDR reports
249SITC of small form factor/mini PC 16GB RAM/512GB SSD for CCTV surveillance with supply of HDMI/DP connector and 15 meter optical HDMI cable compatible with 55\\" professional display
250Supply laying of 32 mm flexible Galvanised steel PVC coated conduit with all fixtures
251Supply, installation, testing, commissioning of Key access management system (Minimum 48 Nos. of key) with RFID card access and inbuilt control unit for RFID card enrolment of as per technical specifications.
252Excavation in all type of soils of width as specified in the technicals specification at approx. depth of 1000mm below ground level, sand bedding, laying of bricks on side and top,backfilling ,dewatering, consolidation, shoring, disposal of excess earth, Item includes supply of sand and class- 1 bricks Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58566259
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 23.37 Crore
LAST DATE 14-12-2026
Authority
Authority Name Bhabha Atomic Research Centre
Work Description Tender for Electrification Package For Blocks 145,122,101,113,119B, 111,107C 135A Etc For Inrp Site, Tarapur
Basic Detail
Tender No BARC(T)/NRB/INRPC/ELE 68/2026/2068A
Bidding Type Tender
Location
City Palghar
State Maharashtra
Key Dates
Publish Date 17 Nov 2026
Submission Date 14 Dec 2026
Open Date 15 Dec 2026
Finance
Tender Value 23.37 Crore
Tender Fee Ref. Documents
EMD 33.37 Lakhs
Exemption Not Available
Document List
72d2e952-136f-4e03-ad33-1fb8ca7dfeab.html
BOQ_981735.xls
TechnicalBid.xls
tenderdoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Dec 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

72d2e952-136f-4e03-ad33-1fb8ca7dfeab.html

xls

BOQ_981735.xls

xls

TechnicalBid.xls

pdf

tenderdoc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender