Science and Technology Statutory Bodies & Commissions/Committees Closing in 6 days TDR #58564945

Tender For Supply Installation Testing and Commissioning of 02 Nos. Ahus With Associated Work Along With Dismantling Of Old Ahus & Duct At Csir-Igib, Dg-1 Building, Mathura Road Campus, Delhi-110025.

Issued by Statutory Bodies & Commissions/Committees · Delhi, Delhi
Tender Value
8.92 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
6 days left
EMD
17843
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 02 Nos. Ahus With Associated Work Along With Dismantling Of Old Ahus & Duct At Csir-Igib, Dg-1 Building, Mathura Road Campus, Delhi-110025.

BOQ

Name of Work:- SITC of 02 nos. AHUs with associated work along with dismantling of old AHUs & duct at CSIR-IGIB, DG-1 building, Mathura road campus, Delhi-110025.
Sl. No. Item Description
1Part-A
2Dismantling of old AHU 15000CFM & 5400CFM
3Supplying, Installation, Testing and commissioning of factory built in confirmation to IS 18794 : 2024 floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine complete with blower section with blower suitable for static pressure as required, minium 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4 row deep, filter section having filters suitable for achieving air quality as per CPWD HVAC pecification 2024 belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) rain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. (Total static pressure considered is max. 50 mm wg).
428900CMH
511900CMH
6Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required. [for both AHU (28900CMH and 11900CMH)]
7Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
880 mm
965 mm
1040 mm
11Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
1250 mm dia
13Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.
14Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified.
1580 mm
1665 mm
17Supply & installation of canvas (for both 28900CMH and 11900CMH AHU) complete as required :
18Ducting work:- including dismentling of old duct of both AHU and fabrication, supply & installation of new duct with necessary supports, hangers, joints and accessories including modification of pelinum box complete as required : .(for both 28900CMH and 11900CMH AHU) (upto 50 Sq.m. , thickness 0.63mm sheet)
19Supply, fabrication and installation of ducting work in the 3rd-floor corridor(T6 AHU duct) , with 19 mm thick insulation throughout the duct length, supply of 250 × 250 mm supply grill and 450 × 450 mm diffuser. The work also includes dismantling and removal of the damaged gypsum board ceiling and supply and installation of a new gypsum board ceiling, including necessary finishing which include paint work and other all necessary accessories related to this work complete as required : .( As per direction of Engineer in charge)
20Supply and replacement of suitable V-belt pulley for the AHU motor, complete with the required grooves, bore diameter, keyway/taper-lock bush, mounting accessories and other necessary fittings, compatible with the existing motor shaft and V-belts. The work shall include removal of existing pulley, installation, proper pulley alignment, belt tensioning, balancing wherever required, and trial run of the AHU for satisfactory operation. The contractor shall verify the existing pulley dimensions, shaft sizes, belt section and operating RPM at site before quoting the rates and commencing the work. All materials shall be suitable for the operating conditions of the AHU. complete as required :
21Motor pulley PCD 125mm ,ID 38 mm, groove- 2
22Blower pulley PCD 355mm ,ID 50 mm, groove- 2
23V-Belt B69
24Part-B (Buyback of old AHUs )
25AHU 5400 CFM with their accessories
26AHU 15000 CFM with their accessories Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58564945
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 8.92 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Supply Installation Testing and Commissioning of 02 Nos. Ahus With Associated Work Along With Dismantling Of Old Ahus & Duct At Csir-Igib, Dg-1 Building, Mathura Road Campus, Delhi-110025.
Basic Detail
Tender No IGIB/W-S/2/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 17 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 8.92 Lakhs
Tender Fee 500
EMD 17843
Exemption Available
Document List
12gcc.pdf
62a7ba73-2125-496f-9263-eebe1f2f93a0.html
BOQ_347180.xls
DeclarationPublicProcurement.pdf
ITPerforma.pdf
SOW.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

12gcc.pdf

html

62a7ba73-2125-496f-9263-eebe1f2f93a0.html

xls

BOQ_347180.xls

pdf

DeclarationPublicProcurement.pdf

pdf

ITPerforma.pdf

pdf

SOW.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender