Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58564904

Tender For Special Repair Of Roof Treatment At Bhandari Ram Enclave Under Age B/R-I And Provn Of Three Phase Electrical Connection For Simulator At Ad Regt Under Age E/M-I Of Ge (N) Mamun.

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
48.40 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
16 days left
EMD
96800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Roof Treatment At Bhandari Ram Enclave Under Age B/R-I And Provn Of Three Phase Electrical Connection For Simulator At Ad Regt Under Age E/M-I Of Ge (N) Mamun.

BOQ

Name of Work:- SPECIAL REPAIR OF ROOF TREATMENT AT BHANDARI RAM ENCLAVE UNDER AGE B/R-I AND PROVN OF THREE PHASE ELECTRICAL CONNECTION FOR SIMULATOR AT AD REGT UNDER AGE E/M-I OF GE (N) MAMUN.
Sl. No. Item Description
1Schedule 'A' Part-I (B/R Works)
2Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
3M&L for brick work with fly ash bricks (using old size bricks), straight or curved on plan exceeding 6m mean radius built in CM 1:6, Complete all as specified and directed.
4M&L for brick work with old servicable bricks retrieved from demolition, straight or curved on plan exceeding 6m mean radius built in CM 1:4, Complete all as specified and directed.
5Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
6M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing even and smooth without using extra cement, complete all as specified and directed.
7M&L for 5mm thick rendering on fair faces of brick work or concrete surfaces of ceiling soffits of slabs, chajjas, columns and beams etc in CM 1:3 and finishing even and smooth without using extra cement, complete all as specified and directed.
8M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finishing even and smooth without using extra cement, complete all as specified and directed.
9M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces of fascia / edging / ceiling of Chajjas, roof projections etc in CM 1:3 and finishing even and smooth without using extra cement including taking out peeled off plaster / concrete and making the line in true shape, complete all as specified and directed.
10Preparation of new surface of wall and applying two coats of cement base paint over a coat of alkali resistance primer for external surface, complete all as specified and directed.
11Preparation of new / old plastered surfaces of walls including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of arcrylic anti-fungal exterior emulsion weather proof paint, complete all as specified and directed.
12Preparation of newly plastered wall surfaces by using necessary filling compound of Altek/Birla white 2mm thick wall care putty to obtain smooth / even surface using sand paper and applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
13Preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
14Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
15Complete removal of existing treatment of walls and applying 2mm thick wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
16Preparation of old plastered or unplastered wall surfaces including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. including cornices, pilasters etc. and applying two coats of white wash, complete all as specified and directed.
17Preparation of old plastered or unplastered ceiling surfaces including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. including filling of cracks and small holes with crack filling paste including cornices, pilasters etc. and applying two coats of white wash, complete all as specified and directed.
18Complete removal of existing treatment from brick walls or concrete plastered or unplastered surfaces including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc. including cornices, pilasters etc. and applying two coats of cement based paint over a coat of primer, complete all as specified and directed.
19Demolition of cement concrete (unreinforced) of any description in any position, complete all as specified and directed.
20M&L for plain cement concrete, 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding, finished even and smooth without using extra cement, complete all as specified and directed.
21M&L for 20mm thick cement plaster on concrete surfaces in cement mortar 1:4, finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 litre in 50 Kg of cement, complete all as specified and directed. (WPC shall be measured and paid separately)
22M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc., complete all as specified and directed :-(a) Cleaning existing surface properly.(b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface.(c) Laying not less than 3.0mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane.(d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
23M&L for preparation of surfaces and apply first coat fiber reinforced elastomatic liquid water proofing membrane formulated with PU hybrid polymersand reinfoecing acrylic fibers with sun reflective Index (SRI) of 100-110 having maximum elongation of 350% tensile strength of 2.9 Mpa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic presure and reduce surface temprerature upto 10 degree celsius with 33% ditution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45grm/Sqm and pasting it properly with overlaping of 50mm and allow it to dry. Apply second coat of undiluted coat @ 0.45 ltr/Sqm. Apply third and final coat undiluted @ 0.45 ltr/sqm. complete application to be done by the manufacture or authorised applicator, complete all as specified and directed
24M&L for plain cement concrete, 1:5:10, Type E-2 (using 40mm graded crushed stone aggregate) as filling in Sunken portion, complete all as specified and directed.
25M&L for 15mm thick cement plaster on concrete surfaces of sunken floor in cement mortar 1:4, with and including water proofing compound to sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement including application of 90 micron polythene film and applying bitumen coating @ 3.00 Kg/Sqm, complete all as specified and directed. (WPC shall measured and paid separately)
26Supply only Liquid water proofing compound, complete all as specified and directed.
27S&F in repairs Vitreous china squatting pan, Orissa pattern, size 580 x 440mm and making good, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., including trap set in and including concrete, complete all as specified and directed.
28M&L for 25mm thick plain cement concrete, 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in sub base, complete all as specified and directed.
29M&L for joint free Non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM 1:4 including dismantling of tiling including cement mortar bedding, complete all as specified and directed.
30M&L for Glazed ceramic tile 450x350x06-7mm thick (coloured) on vertical surfaces such as wall, dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10mm thick screed bed in CM 1:4 including dismantling of tiling including cement mortar bedding, complete all as specified and directed.
31Schedule 'A' Part-II (E/M Works)
32Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 70 Sqmm 3.5 core, conforming to IS 1554 Part I / ISI marked, 1100 Volt grade, including cable glands , cable lugs etc, to suitable the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc., complete all as speccified and directed.
33Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 50 Sqmm 3.5 core, conforming to IS 1554 Part I / ISI marked, 1100 Volt grade, including cable glands , cable lugs etc, to suitable the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc., complete all as speccified and directed.
34Excavation in trenches by mechanical means, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc., complete all as specified and directed
35Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing, complete all as specified and directed.
36Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point, complete as specified and directed.
37M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed.
38M&L for bricks, well burnt, sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed
39S&F 40mm dia galvanised steel tube, light grade, for protection of copper strip / cable at wall and duct / road / trench, complete all as specified and directed.
40S&F of un-reinforced precast concrete cable route indicator of size 800mm x 300mm x 100mm, laid alongwith the cable and at turning points of cable route at minimum depth of 300mm from GL , complete all as specified and directed.
41Supply, fixing, commissioning and testing of Feeder pillar box panel, factory made, powdered coated, CPRI approved, floor mounting, outdoor type, double door, cubical panel fabricated out of 3.15mm thick CRCA sheet suitable for 440 Volts 3 phase, 4 wire, 50 cycle per second, weather proof, fabricated on 50 X 50 X 4mm thick MS angle iron frame of size 75cm complete, AC supply comprising of capacity 600 Amp (4 strip) aluminium bus bar for phase and neutral mounted on post insulators, MCB DP 63 Amps-3 Nos, wiring the panel with suitable size PVC insulated and sheathed copper cable complete including painting internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer and panel comprises of the following accessories :-(i) Incomming: MCCB 200 Amps, FP, 415 V, 36 KΑ - 01 Νο(ii) Outgoing: MCCB, 160 Amps, FP, 415 V, 16 KA - 02 Nos (iii) Digital Voltmeter (0-500) volt with selector switch -01 No(iv) Digital Ammeter with CTs (0-500) Amps with selector switch - 01 No (v) Indicator lamp - 01 set of three(v) Platform for the feeder pillar board with PCC 1:2:4, 15cm thick in foundation, brick (sub class B) work in CM 1:6, redering 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in padding on top and grouting legs of panel. The platform shall be 450mm height above the ground level.
42M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 25 x 4mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle, complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
43Supply, install, testing and commissioning of LT busbar chamber box, outdoor type, CPRI approved, with fixing arangement such as clamps, nut botls and washer wall / pole mounted, made out of 2.00mm thick CRCA sheet, weather proof, dust and vermin proof, IP -43, powder coated with 8 tank process, sleeve insulated aluminium bus bar 300 Amps, 3 phase, 4 wire 415 volts, single side openable and locking arrangements for compartment includin necessary grouting wall, PCC work including MCCB of 250 Amps, 4 pole, 415 volts, 50 Hz with fixed megnatic and thermal release complete including connection from bus bar to meter in meter box with 10 Sqmm single core wire duly concealed with PVC pipe, complete all as specified and directed.
44Deduction to be made from BOQ for Schedule 'A' Part-III (Credit Schedule from dismantling / taking down items) worth Rs 850.00 during AOC.(Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58564904
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.40 Lakhs
LAST DATE 08-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Roof Treatment At Bhandari Ram Enclave Under Age B/R-I And Provn Of Three Phase Electrical Connection For Simulator At Ad Regt Under Age E/M-I Of Ge (N) Mamun.
Basic Detail
Tender No GE(N)/M-80/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 17 Nov 2026
Submission Date 08 Dec 2026
Open Date 15 Dec 2026
Finance
Tender Value 48.40 Lakhs
Tender Fee 500
EMD 96800
Exemption Not Available
Document List
BOQ_896502.xls
c1dca9e7-f8fb-4131-a47b-7e2ddecfb653.html
Tender80.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_896502.xls

html

c1dca9e7-f8fb-4131-a47b-7e2ddecfb653.html

pdf

Tender80.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender