Housing Urban and Rular Development Government Departments Closing in 3 days TDR #58563973

Tender For repair maintenance Specialized Electrical & Mechanical Services At 5 Sham Nath Marg, Delhi (Sh:- Replacement Of Exiting Old Unserviceable Passenger Lift At Labour Commissioner Department)

Issued by Government Departments · Delhi, Delhi
Tender Value
18.35 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
3 days left
EMD
36709
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance Specialized Electrical & Mechanical Services At 5 Sham Nath Marg, Delhi (Sh:- Replacement Of Exiting Old Unserviceable Passenger Lift At Labour Commissioner Department)

BOQ

Name of Work:- RMO Specialized Electrical & Mechanical Services at 5 Sham Nath Marg, Delhi (SH:- Replacement of exiting old unserviceable Passenger Lift at Labour Commissioner Department)
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision as per detailed specifications enclosed including minor civil work in the lift shaft such as plastering, levelling etc. and as under including all other equipment and accessories complete as required:- (i) Speed-1 MPS (ii) Floors-4 (G+3) (iii) Travel -14 Meters (approx.) or as per site requirement (iv) Stops & opening- 4 stops and 4 openings (v) Controller: A. C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
2(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup, Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided a) 10 Passengers Lift
3Dismantling of the existing lift including dismantling all the parts in the shaft and in machine room and credit for the old lift under buy back etc. complete as reqd. This also includes the levlling the surface of the lift shaft with plastering, putty paints if required etc. complete as reqd.
4Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1. 5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1. 5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(a) Group C
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
6b) 2 X 1. 5 sq. mm + 1 X 1. 5 sq. mm earth wire
7Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 4 way (4 + 12), Double door
8Supplying and fixing of following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole 5-32 Amp SP MCB
9b) Tripl Pole 63 Amp.
10Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade on surface etc. as required.a) 4 x 25 sq.mm
11Providing and fixing 6 SWG dia G. I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
12Earthing with G. I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 Meter long etc. with charcoal/ coke and salt as required.
13Providing and fixing 25 mm X 5 mm G. I. strip in 40 mm dia G. I. pipe from earth electrode including connection with G. I. nut, bolt, spring, washer excavation and re-filling etc. as required.
14Providing and fixing 25 mm X 5 mm G. I. strip on surface or in recess for connections etc. as required.
15Supplying, Installation, Testing & Commissioning of 10 watt LED Bulkhead Fitting having lumens not less than 100 lumens per watt made of aluminium die cast body i/c making connections etc. complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58563973
AUTHORITY Government Departments
TENDER VALUE 18.35 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Specialized Electrical & Mechanical Services At 5 Sham Nath Marg, Delhi (Sh:- Replacement Of Exiting Old Unserviceable Passenger Lift At Labour Commissioner Department)
Basic Detail
Tender No 176/EEE/PWDDHC,NDC/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 17 Nov 2026
Submission Date 23 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 18.35 Lakhs
Tender Fee Ref. Documents
EMD 36709
Exemption Not Available
Document List
512f8fcd-0dbc-4d7f-8079-cd15cfcd96d3.html
BOQ_402364.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

512f8fcd-0dbc-4d7f-8079-cd15cfcd96d3.html

xls

BOQ_402364.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender