Public Administrative Department Trust & NGO Closing in 16 days TDR #58563641

Tender For Proposed Renovation Of Sainath Hospital, Shirdi For Shri Saibaba Sansthan Trust, Shirdi

Issued by Trust & NGO · Ahmednagar, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Dec 2026
16 days left
EMD
7.50 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Proposed Renovation Of Sainath Hospital, Shirdi For Shri Saibaba Sansthan Trust, Shirdi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Nov-2026 Bill Of Quantity BOQ 07-Dec-2026

BOQ

Name of Work:- PROPOSED RENOVATION OF SAINATH HOSPITAL, SHIRDI FOR SHRI SAIBABA SANSTHAN TRUST, SHIRDI
Sl. No. Item Description
1SCHEDULE B- NORTH SIDE BUILDING
2Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.
3Ground Floor
4First Floor
5Second Floor
6Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
7Ground Floor
8First Floor
9Second Floor
10Removing Paving blocks 60 & 80 mm ,cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
11Ground Floor
12First Floor
13Second Floor
14Removing Grills, doors, window grill panel & windows with frames and stacking the materials as directed with all leads, lifts etc. complete.( deposited to the Sai Baba Sansthan )
15Ground Floor
16First Floor
17Second Floor
18Removing Internal & External Existing Plumbing material i.e. GI pipes, cast iron or wrought iron or A.C. pipe ,PVC,,UPVC Pipes etc and stacking them as directed with all leads, lifts etc. complete.( deposited to the Sai Baba Sansthan )
19Ground Floor
20First Floor
21Second Floor
22Third Floor
23Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete ( deposited to the Sai Baba Sansthan )
24Ground Floor
25First Floor
26Second Floor
27Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. ( deposited to the Sai Baba Sansthan )
28Ground Floor
29First Floor
30Second Floor
31Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. ( deposited to the Sai Baba Sansthan )
32Ground Floor
33Removing and lowering the roof truss carefully without damaging the members and stacking as and where directed in the compound including scaffolding etc. complete. ( deposited to the Sai Baba Sansthan )
34Ground Floor
35Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge
36Ground Floor
37Epoxy injection grout in concrete/RCC work of approved make
38Ground Floor
39First Floor
40Second Floor
41Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
42Ground Floor
43Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
44Ground Floor
45Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
46Ground Floor
47Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
48Ground Floor
49Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
50Ground Floor
51Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
52Ground Floor
53Terrace Floor
54Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
55Ground Floor
56Terrace Floor
57Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
58Terrace Floor
59Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
60Third Floor
61Terrace Floor
62Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
63Ground Floor
64Third Floor
65Terrace Floor
66Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth
67Ground Floor
68Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
69Ground Floor
70First Floor
71Second Floor
72Third Floor
73Terrace Floor
74Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
75Ground Floor
76First Floor
77Second Floor
78Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
79Terrace Floor
80Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
81Terrace Floor
82Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand.
83Terrace Floor
84Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.
85Ground Floor
86First Floor
87Second Floor
88Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
89Ground Floor
90First Floor
91Second Floor
92Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
93Ground Floor
94First Floor
95Second Floor
96Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
97Ground Floor
98First Floor
99Second Floor
100Terrace Floor
101Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
102Ground Floor
103First Floor
104Second Floor
105Third Floor
106Terrace Floor
107Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
108Ground Floor
109First Floor
110Second Floor
111Third Floor
112Terrace Floor
113Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
114Ground Floor
115First Floor
116Second Floor
117Third Floor
118Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
119Ground Floor
120First Floor
121Second Floor
122Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring
123Ground Floor
124First Floor
125Second Floor
126Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement/adhesive float, filling joints, curing and clearing etc. complete
127Ground Floor
128First Floor
129Second Floor
130Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
131Ground Floor
132First Floor
133Second Floor
134Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement/adhesive float, filling joints, curing and cleaning etc. complete.
135Ground Floor
136First Floor
137Second Floor
138Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
139Ground Floor
140First Floor
141Second Floor
142Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement/adhesive floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
143Ground Floor
144First Floor
145Second Floor
146Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
147Ground Floor
148First Floor
149Second Floor
150Third Floor
151Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
152Ground Floor
153Providing and fixing heavy duty inter locking concrete Grey paving blocks of 60 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete.
154Removing Existing Paver Block and fixing to front side labour charges
155Providing and fixing heavy duty inter locking concrete Grey paving blocks of 60 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete.
156fixing paver block on sand coushning
157Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
158Ground Floor Two Coats of Putty to new surface
159Ground Floor One Coats of Putty to Old surface
160First Floor Two Coats of Putty to new surface
161First Floor One Coats of Putty to Old surface
162Second Floor Two Coats of Putty to new surface
163Second Floor One Coats of Putty to Old surface
164Third Floor
165Terrace Floor
166Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
167Ground Floor
168Check
169First Floor
170Check
171Second Floor
172Check
173Third Floor
174Terrace Floor
175Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete.
176Ground Floor
177First Floor
178Second Floor
179Third Floor
180Terrace Floor
181Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: ForItem No. 15 to 18 prior approval of Superintending Engineer will be necessary
182Ground Floor
183First Floor
184Second Floor
185Third Floor
186Terrace Floor
187Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
188Ground Floor
189First Floor
190Second Floor
191Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
192Ground Floor
193First Floor
194Second Floor
195Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box
196Ground Floor
197First Floor
198Second Floor
199Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
200Ground Floor
201First Floor
202Second Floor
203Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
204Ground Floor
205First Floor
206Second Floor
207Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
208Ground Floor
209First Floor
210Second Floor
211Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/Sqm is considered.
212Ground Floor
213First Floor
214Second Floor
215Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
216Ground Floor
217First Floor
218Second Floor
219Turbo Ventilators 24\\"
220Ground Floor
221Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
222Ground Floor
223First Floor
224Second Floor
225Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
226Ground Floor
227First Floor
228Second Floor
229Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
230Ground Floor
231First Floor
232Second Floor
233Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
234Ground Floor
235First Floor
236Second Floor
237Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
238Ground Floor
239First Floor
240Second Floor
241Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
242Ground Floor
243First Floor
244Second Floor
245Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
246Ground Floor
247Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and No. ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
248Ground Floor
249First Floor
250Second Floor
251Third Floor
252Terrace Floor
253Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
254Ground Floor
255Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
256Ground Floor
257Providing and fixing 25 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
258Ground Floor
259First Floor
260Second Floor
261Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
262Ground Floor
263First Floor
264Second Floor
265Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete.
266Ground Floor
267First Floor
268Second Floor
269Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
270Ground Floor
271First Floor
272Second Floor
273Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.
274Ground Floor
275First Floor
276Second Floor
277Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.
278Ground Floor
279First Floor
280Second Floor
281Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
282Ground Floor
283First Floor
284Second Floor
285Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete.
286Ground Floor
287First Floor
288Second Floor
289Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.
290Ground Floor
291First Floor
292Second Floor
293Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
294Ground Floor
295First Floor
296Second Floor
297Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
298Ground Floor
299First Floor
300Second Floor
301Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )
302Ground Floor
303First Floor
304Second Floor
305Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete.
306Ground Floor
307First Floor
308Second Floor
309Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
310Ground Floor
311First Floor
312Second Floor
313Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
314Ground Floor
315Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete.
316Ground Floor
317First Floor
318Second Floor
319Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
320Ground Floor
321First Floor
322Second Floor
323Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
324Terrace Floor
325Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.
326Ground Floor
327Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.
328Ground Floor
329Supply and installation of double skin sandwich for Roofing. Make: KINGSPAN JINDAL STRUPAN Panels 1000 mm width 50mm thick. Key Component: panel thickness: 50mm Panel cover width : 1000mm, Inner/Outer skin: 0.4mm PPGI/0.35mm PPGI, Material of Skin external: 0.40mm TCT 240MPa, PPGI sheet, RMPolyester Coated Ral9002 120GSM Trapazoidal Profile, Infill Insulation material PUR Core, Density 40+-2 kg/Rmt. cube., Material of skin Internal: 0.35 mm TCT 240MPa, PPGI sheet, RMPolyester Coated Ral9002 120 GSM, MicroRibbed profile. panel Lengths can be made to suit site requirement upto 12 Rmt Transportable length.
330Ground Floor
331Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.).
332Ground Floor
333Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
334Ground Floor
335Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
336Ground Floor
337First Floor
338Second Floor
339Third Floor
340Providing And Fixing WPC Board Design -Base Of 18mm thick WPC Board CNC Cutting Design As per Approved Design {Size Height - 300mm). Design of Flower Made of 18mm thick PWC bord CNC Cutting fix on tsase Design WFC With Adhesive Bound Chemical. WPC Board Density 540 kg./m3 sa per IS 2380 (Pt.3), Izod impact strenth 10\\"07 As per ASTM D 254 HDT@ 1.8 MPA 71-1 degg C As per ASTi\, D 648 Flexural strength 15.5 Mpa as per tS 2380 (Pt.4), Tensile Strength - 5.5 MPa as per 15 2380, Water Absorptiofl after 24 hr. -1.2% As per IS 2380 (Pt.16)' Screw withdrawal Edge-1?70N, Face-850N as per IS ?380 (Pt.14), Nail Withdrawal (edge)-508N as Per IS 2380 (Pt.14), Flammability -Match with VO as per UL 94, Resistance To Crack -No creck observed As per 15 12823:1999 Board Finished with a coat of Primer then spray painting. Fixing on surface with Screw or nails. etc complete as per the manufacturer's specifications and to the entire satisfaction of Engineer in charge
341Ground Floor
342Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
343Ground Floor
344First Floor
345Second Floor
346Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system
347Ground Floor
348First Floor
349Second Floor
350Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\\"x 9\\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.
351Ground Floor
352First Floor
353Second Floor
354Design, supply, fabrication and fixing of SS, non glare multilingual Braille (raised dots) entrance signage (size 1 ft x 1 ft) as per the approved design and make,indicating the name of the building. Having 1.2mm thick SS non glare blue coloured base plate with the 'Universal Accessibility Symbol' and Upper case Sans Serif words of height 15mm engraved on it along with the equivalent word/ s written in Hindi using Devnagri script of height 15mm in white colour. Grade 2/ Grade 1 Braille to be etched/ engraved and be raised 0.5mm above base plate.The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge.
355Ground Floor
356First Floor
357Second Floor
358SCHEDULE B- SOUTH SIDE BUILDING
359Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.
360Ground Floor
361First Floor
362Second Floor
363Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
364Ground Floor
365First Floor
366Second Floor
367Removing Paving blocks 60 & 80 mm ,cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
368Ground Floor
369First Floor
370Second Floor
371Removing Grills, doors, window grill panel & windows with frames and stacking the materials as directed with all leads, lifts etc. complete.( deposited to the Sai Baba Sansthan )
372Ground Floor
373First Floor
374Second Floor
375Removing Internal & External Existing Plumbing material i.e. GI pipes, cast iron or wrought iron or A.C. pipe ,PVC,,UPVC Pipes etc and stacking them as directed with all leads, lifts etc. complete.( deposited to the Sai Baba Sansthan )
376Ground Floor
377First Floor
378Second Floor
379Third Floor
380Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete ( deposited to the Sai Baba Sansthan )
381Ground Floor
382First Floor
383Second Floor
384Removing W.C. pans including disconnecting the sanitary and water supply connections removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directedincluding throwing the unserviceable materials out side etc. carefully and throwing out the refusal outside etc. complete throwing the unserviceable materials outside etc complete ( deposited to the Sai Baba Sansthan )
385Ground Floor
386First Floor
387Second Floor
388Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. ( deposited to the Sai Baba Sansthan )
389Ground Floor
390Removing and lowering the roof truss carefully without damaging the members and stacking as and where directed in the compound including scaffolding etc. complete. ( deposited to the Sai Baba Sansthan )
391Ground Floor
392Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (Bridge connected to north & south Building )
393Ground Floor
394Extra for marking of structural steel work required to be re-erected.(Bridge connected to north & south Building )
395Ground Floor
396Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
397Ground Floor
398First Floor
399Second Floor
400Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge
401Ground Floor
402First Floor
403Second Floor
404Epoxy injection grout in concrete/RCC work of approved make
405Ground Floor
406First Floor
407Second Floor
408Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
409Ground Floor
410Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
411Ground Floor
412Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
413Ground Floor
414Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
415Ground Floor
416Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
417Ground Floor
418Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
419Ground Floor
420Terrace Floor
421Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
422Ground Floor
423Third Floor
424Terrace Floor
425Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
426Terrace Floor
427Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
428Third Floor
429Terrace Floor
430Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
431Ground Floor
432Third Floor
433Terrace Floor
434Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth
435Ground Floor
436Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
437Ground Floor
438First Floor
439Second Floor
440Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
441Ground Floor
442First Floor
443Second Floor
444Terrace Floor
445Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
446Terrace Floor
447Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand.
448Terrace Floor
449Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.
450Ground Floor
451First Floor
452Second Floor
453Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
454Ground Floor
455First Floor
456Second Floor
457Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
458Ground Floor
459First Floor
460Second Floor
461Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
462Ground Floor
463First Floor
464Second Floor
465Terrace Floor
466Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
467Ground Floor
468First Floor
469Second Floor
470Third Floor
471Third Floor
472Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
473Ground Floor
474First Floor
475Second Floor
476Third Floor
477Terrace Floor
478Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
479First Floor
480First Floor
481Second Floor
482Third Floor
483Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
484First Floor
485First Floor
486Second Floor
487Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring
488Ground Floor
489First Floor
490Second Floor
491Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement/adhesive float, filling joints, curing and clearing etc. complete
492Ground Floor
493First Floor
494Second Floor
495Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
496Ground Floor
497First Floor
498Second Floor
499Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement/adhesive float, filling joints, curing and cleaning etc. complete.
500Ground Floor
501First Floor
502Second Floor
503Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
504Ground Floor
505First Floor
506Second Floor
507Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement/adhesive floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
508Ground Floor
509First Floor
510Second Floor
511Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
512Ground Floor
513First Floor
514Second Floor
515Third Floor
516Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
517Ground Floor
518Providing and fixing existing heavy duty inter locking concrete Grey paving blocks of 60 mm & 80 thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. to front side of building complete.
519Removing Existing Paver Block and fixing to front side only labour rate consider
520Providing and fixing heavy duty inter locking concrete Grey paving blocks of 60 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete.
521Fixing Paver Block on sand coushning
522Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
523Ground Floor Two Coats of Putty to new surface
524Ground Floor One Coats of Putty to Old surface
525First Floor Two Coats of Putty to new surface
526First Floor One Coats of Putty to Old surface
527Second Floor Two Coats of Putty to new surface
528Second Floor One Coats of Putty to Old surface
529Third Floor
530Terrace Floor
531Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
532Ground Floor
533Check Empty
534First Floor
535Check Empty
536Second Floor
537Check Empty
538Third Floor
539Terrace Floor
540Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete.
541Ground Floor
542First Floor
543Second Floor
544Third Floor
545Terrace Floor
546Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: ForItem No. 15 to 18 prior approval of Superintending Engineer will be necessary
547Ground Floor
548First Floor
549Second Floor
550Third Floor
551Terrace Floor
552Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
553Ground Floor
554First Floor
555Second Floor
556Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
557Ground Floor
558First Floor
559Second Floor
560Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box
561Ground Floor
562First Floor
563Second Floor
564Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
565Ground Floor
566First Floor
567Second Floor
568Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
569Ground Floor
570First Floor
571Second Floor
572Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
573First Floor
574Second Floor
575Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/Sqm is considered.
576Ground Floor
577First Floor
578Second Floor
579Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
580Ground Floor
581First Floor
582Second Floor
583Turbo ventilator 24\\"
584Terrace Floor
585Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
586Ground Floor
587First Floor
588Second Floor
589Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
590Ground Floor
591First Floor
592Second Floor
593Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
594Ground Floor
595First Floor
596Second Floor
597Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
598Ground Floor
599First Floor
600Second Floor
601Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
602Ground Floor
603First Floor
604Second Floor
605Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
606Ground Floor
607First Floor
608Second Floor
609Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
610Ground Floor
611Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and No. ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
612Ground Floor
613First Floor
614Second Floor
615Third Floor
616Terrace Floor
617Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
618Ground Floor
619Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
620Ground Floor
621Providing and fixing 25 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
622Ground Floor
623First Floor
624Second Floor
625Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
626Ground Floor
627First Floor
628Second Floor
629Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete.
630Ground Floor
631First Floor
632Second Floor
633Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
634Ground Floor
635First Floor
636Second Floor
637Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.
638Ground Floor
639First Floor
640Second Floor
641Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.
642Ground Floor
643First Floor
644Second Floor
645Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
646Ground Floor
647First Floor
648Second Floor
649Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete.
650Ground Floor
651First Floor
652Second Floor
653Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.
654Ground Floor
655First Floor
656Second Floor
657Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
658Ground Floor
659First Floor
660Second Floor
661Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
662Ground Floor
663First Floor
664Second Floor
665Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )
666Ground Floor
667First Floor
668Second Floor
669Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete.
670Ground Floor
671First Floor
672Second Floor
673Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
674Ground Floor
675First Floor
676Second Floor
677Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
678Ground Floor
679Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete.
680Ground Floor
681First Floor
682Second Floor
683Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
684Ground Floor
685First Floor
686Second Floor
687Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
688Terrace Floor
689Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.
690Ground Floor
691Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.
692Ground Floor
693Supply and installation of double skin sandwich for Roofing. Make: KINGSPAN JINDAL STRUPAN Panels 1000 mm width 50mm thick. Key Component: panel thickness: 50mm Panel cover width : 1000mm, Inner/Outer skin: 0.4mm PPGI/0.35mm PPGI, Material of Skin external: 0.40mm TCT 240MPa, PPGI sheet, RMPolyester Coated Ral9002 120GSM Trapazoidal Profile, Infill Insulation material PUR Core, Density 40+-2 kg/Rmt. cube., Material of skin Internal: 0.35 mm TCT 240MPa, PPGI sheet, RMPolyester Coated Ral9002 120 GSM, MicroRibbed profile. panel Lengths can be made to suit site requirement upto 12 Rmt Transportable length.
694Ground Floor
695Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.).
696Ground Floor
697Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
698Ground Floor
699Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
700Ground Floor
701First Floor
702Second Floor
703Third Floor
704Providing And Fixing WPC Board Design -Base Of 18mm thick WPC Board CNC Cutting Design As per Approved Design {Size Height - 300mm). Design of Flower Made of 18mm thick PWC bord CNC Cutting fix on tsase Design WFC With Adhesive Bound Chemical. WPC Board Density 540 kg./m3 sa per IS 2380 (Pt.3), Izod impact strenth 10\\"07 As per ASTM D 254 HDT@ 1.8 MPA 71-1 degg C As per ASTi\, D 648 Flexural strength 15.5 Mpa as per tS 2380 (Pt.4), Tensile Strength - 5.5 MPa as per 15 2380, Water Absorptiofl after 24 hr. -1.2% As per IS 2380 (Pt.16)' Screw withdrawal Edge-1?70N, Face-850N as per IS ?380 (Pt.14), Nail Withdrawal (edge)-508N as Per IS 2380 (Pt.14), Flammability -Match with VO as per UL 94, Resistance To Crack -No creck observed As per 15 12823:1999 Board Finished with a coat of Primer then spray painting. Fixing on surface with Screw or nails. etc complete as per the manufacturer's specifications and to the entire satisfaction of Engineer in charge
705Ground Floor
706Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
707Ground Floor
708First Floor
709Second Floor
710Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system
711Ground Floor
712First Floor
713Second Floor
714Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\\"x 9\\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.
715Ground Floor
716First Floor
717Second Floor
718Design, supply, fabrication and fixing of SS, non glare multilingual Braille (raised dots) entrance signage (size 1 ft x 1 ft) as per the approved design and make,indicating the name of the building. Having 1.2mm thick SS non glare blue coloured base plate with the 'Universal Accessibility Symbol' and Upper case Sans Serif words of height 15mm engraved on it along with the equivalent word/ s written in Hindi using Devnagri script of height 15mm in white colour. Grade 2/ Grade 1 Braille to be etched/ engraved and be raised 0.5mm above base plate.The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge.
719Ground Floor
720First Floor
721Second Floor
722SCHEDULE B- RCC DRAIN
723Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
724Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
725R.C.C.pipe Np2 class 450mm dia. 2.5m long with collar
726Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.
727SCHEDULE B- TRENCH DRAIN
728Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
729Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
730Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
731Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
732Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
733Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
734Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
735Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.
736Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
737SCHEDULE B- ESR
738Excavation for foundation, Substructures, basements, tanks,sumps walls ,chambers, manholes,trenches, poles, pits & general building works in soft/disintegrated rock, sand stone ,stiff clay, gravel,cobblestone,hard laterite water bound macadam, wet mix macadam, asphalt mix carpet of any type, pitching, soiling, paths and handcore, lime concrete, plain cement concrete, stone masonary and all types of brick block masonary below ground level, rock boulders, esc for depths lifts upto 1.5 M measured from the ground level, including dressing trimming the sides. leveling of bottoms, manual dewatering, removing rank vegetation, backfilling in layers not more than 200mm thickness, watering, consolidating, compacting to achieve not less then 97% Modified Proctor density conforming to relevant IS, stacking in measurable heaps for future usewithin owners space or disposing within an initial lend of 150m as directed, loading, unloading, leveling excluding shoring.strutting etc complete as directed by Engineer-in-Charge Note 1) The rate includes the handling supporting the existing utilities such as cables, drains, pipes, water mains etc.2) It also includes the royalty and other taxes if any.
739Providing & Laying dry stone Rubble Soling with average 230 mm size hard stone set in regular lines, handpacked and interstices thoroughly filled with small chips including filling in with good quality murum brought from outside, compacting with iron 4 rammers, watering, sand spreading 12mm thk. layer of grit on top ete complete as directed by Engineer In Charge.(Note: The rate includes the royalty and other taxes if any)
740Making plinth with necessary excavation in ground, providing M-10 grade PCC at bottom and top, constructing burnt brick masonry wall along the periphery, filling the remaining hollow portion with hard broken aggregate, and duly plastering the external surface, including watering. curing, labour. materials and all other incidental works, complete in all respects.
741Providing and laying reinforced cement concrete of specified grade for foundation/base of fire water tank supporting structure, including mixing, laying, compacting, vibrating, curing and finishing complete as per approved structural drawings and directions of Engineer-in-Charge.
742Providing, fabricating and fixing M.S. rolled steel I-Beam sections of approved size and section, for supporting the prefabricated fire water tank, including cutting, drilling, welding, fabrication. erection, alignment, fixing with required bolts, nuts, washers, cleats, stiffeners and base plates, surface preparation, primer and protective painting, complete as per approved structural drawings and instructions of Engineer-in-Charge.
743Providing and laying Cast in situ Ready S Mix cement concrete M-25 of trap granite quartzite gneissmetal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions ete, including bailing out water, Steel centering, cover blocks, formwork laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
744Providing and laying reinforced cement concrete slab of specified grade and thickness for supporting the prefabricated fire water tank, including centering, shuttering, reinforcement, 9 mixing, laying, compacting, vibrating, curing and finishing complete as per approved structural drawings and instructions of Engineer-in-Charge
745SCHEDULE B- ENTRANCE GATE
746Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
747Ground Floor
748Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means
749Ground Floor
750Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
751Ground Floor
752Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.
753Ground Floor
754Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
755Ground Floor
756Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
757Ground Floor
758Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
759Ground Floor
760Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
761Ground Floor
762Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
763Ground Floor
764Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
765Ground Floor
766Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
767Ground Floor
768Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
769Ground Floor
770Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
771Ground Floor
772Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
773Ground Floor
774Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer.
775Ground Floor
776Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
777Ground Floor
778Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
779Ground Floor
780Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
781Ground Floor
782Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
783Ground Floor
784Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
785Ground Floor
786Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
787Ground Floor
788Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
789Ground Floor
790Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
791Ground Floor
792Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: ForItem No. 15 to 18 prior approval of Superintending Engineer will be necessary
793Ground Floor
794Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm .
795Ground Floor
796Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
797Ground Floor
798Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
799Ground Floor
800Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box
801Ground Floor
802Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.)Spec.No.: As directed by Engineer- in-charge.
803Ground Floor
804Directional signageDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\\" x 9\\" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge.
805Ground Floor
806SCHEDULE B- COMPOUND WALL
807Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
808Ground Floor
809Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means
810Ground Floor
811Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
812Ground Floor
813Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.
814Ground Floor
815Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
816Ground Floor
817Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
818Ground Floor
819Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
820Ground Floor
821Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
822Ground Floor
823Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
824Ground Floor
825Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
826Ground Floor
827Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
828Ground Floor
829Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
830Ground Floor
831Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
832Ground Floor
833Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: ForItem No. 15 to 18 prior approval of Superintending Engineer will be necessary
834Ground Floor
835SCHEDULE B- LANDSCAPE
836Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed inearth, soil of all types, soft murum, including removing the excavated materialup to a distance of 50 Rmt. for a depth of 30 cms
837Filling fresh garden soil / silt & manure in excavated area of depth 30cms.
838Mixing garden soil/silt & manure thoroughly well, watering previous night.Planting reqired plant species, lawn grass as directed etc. complete for requireddepth 5 to 30 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ cannabed/ ground cover
8391 (a)Flowering ShrubsSpecification:- Well Developed ,Fresh, Healthy half in bloom, free from pest anddiseases Hibiscus
8401 (a)Flowering ShrubsSpecification:- Well Developed ,Fresh, Healthy half in bloom, free from pest anddiseases Ixora Mini
84111 (a)PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriateSize in Polybag,undamagedRoyal Palm Ht 3 to 4 ft
842Flowering B) Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum numberof Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system areundamaged.Bakul 8' to 10' Ft
843Flowering B) Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum numberof Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system areundamaged.Gulmohar 8' to 10' Ft
844SCHEDULE B- CANTEEN BUILDING
845Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
846Ground Floor
847First Floor
848Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
849Ground Floor
850First Floor
851Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.
852Ground Floor
853First Floor
854Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
855Ground Floor
856First Floor
857Second Floor
858SCHEDULE B- FIRE FIGHTING WORK
859Supplying, erecting & terminating FR XLPE insulated, galvanisedsteel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq.mm. copper conductor complete erected with glands & lugs, onwall/ trusses/ pole or laid in provided trench/ pipe as perspecification no. CB-LT/CU
860Supplying, erecting & terminating FR XLPE insulated, galvanisedsteel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq.mm. copper conductor complete erected with glands & lugs, onwall/ trusses/ pole or laid in provided trench/ pipe as perspecification no. CB-LT/CU
861Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of4.5 kg.capacity cartridge type conform to IS 2878 /15683 completeerected with necessary clamp made from 50 x 6 mm. M. S. flatwith nut & bolts routed in wall complete.
862Supplying, installation, testing and commissioning of main firepump(MFP / EP) suitable for water discharge of 2280 to 2850LPM at 120 to 90 m head driven by electric motor 415 volts, 3phase 50 Hz, AC supply of 75kW or ofsuitable kW capacity for manual/automatic operation andconsisting of following:(a) Horizontal type, single stage,centrifugal/split casing pump of cast iron body &bronze impellerwith stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520. (b) Squirrel cage induction motor, TEFC,synchronous speed 3000 RPM, suitable for operation with IP 55protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated commonbase plate, coupling, coupling guard, foundation bolts etc. asrequired. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfectaligning, proper levelling complete pump set with accessories dulypainted with two coats of synthetic enamel paint of fire red colourover a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/SSC/EP
863Supplying, installation, testing and commissioning of jockey firepump (JP)suitable for water discharge of 180 to 240 LPM at 110 to90 m head drivenby electric motor 415 volts, 3 phase 50 Hz, ACsupply of 11 kW or of suitable kW capacity for manual/automaticoperation and consisting of following:(a) Horizontal/vertical type,multi stage, centrifugal casing pump of cast iron body & bronzeimpeller with stainless steel shaft (SS410 grade), mechanicalsealconforming to IS 1520. (b) Squirrel cage induction motor,TEFC, synchronous speed 3000 RPM, suitablefor operation withIP 55 protection for enclosure, horizontal foot mounted typewithClass-'F' insulation, conforming to IS-325.(c) M.S. fabricatedcommon base plate, coupling, coupling guard, foundation boltsetc.as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfectaligning, proper levelling complete pump setwith accessories dulypainted with two coats of synthetic enamel paint of fire redcolourover a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/JP
864Supplying, installation,testing and commissioning of booster firepump [BP]suitable for water discharge of 900 LPM at 35 m headdriven by electricmotor 415 volts, 3phase 50 Hz, AC supply of 7.5kW or of suitable kWcapacity for manual/automatic operation andconsisting of following :(a) Horizontal/vertical type, single/multistage, centrifugal casing pump of castiron body & bronze/CIimpeller with stainless steel shaft (SS410 grade),mechanical sealconforming to IS 1520.(b) Squirrel cage induction motor, TEFC,synchronous speed 3000 RPM, suitablefor operation on with IP 55protection for enclosure, horizontal foot mountedtype with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated commonbase plate, coupling, coupling guard, foundation boltsetc.required.(d)Erected on provided suitable size cement concretefoundation duly plasteredwith anti vibration pads with perfectaligning, proper levelling complete pump setwith accessories dulypainted with two coats of synthetic enamel paint of fire redcolourover a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/BPEach 69720Page
865Supplying, installation, testing and commissioning of main firepump (MFP/DP) suitable for water discharge of 2280 to 2850LPM at 90 to 60 mhead driven by 76 HP or suitable HP capacitydiesel engine at requiredworking speed suitable formanual/automatic operation andc onsisting offollowing : (a)Horizontal type, single stage, centrifugal casing pump of cast ironbody & bronze impeller with stainless steel shaft(SS410 grade),mechanical seal conforming to IS 1520. (b) Water cooled withradiator, diesel engine conforming to relevant IS standard completewith auto starting mechanism, 12/24 volts DC electric startingequipment with battery of required AH capacity with necessarycharger suitable to work on 230v, 50Hz AC supply, diesel tank ofminimum 150ltr capacity with first filling of diesel up to 100%level with necessary piping with valves up to engine , exhaust pipeextended up to 10 m outside pump house duly insulated with 50mm thick glass wool with 1.0 mm thick aluminium sheet cladding,residential silencer, instruments and protection as per standardspecification, stop solenoid for auto stop in the event of fault withaudio indications etc. as required. (c) M.S. fabricated commonbase plate, coupling, coupling guard, foundation bolts etc. asrequired. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfectaligning, proper levelling complete pump set with engine assemblyand accessories duly painted with two coats of synthetic enamelpaint of fire red colour over a coat of primer (ISC code 536 as perIS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
866Supplying and erecting G.I. pipe ζC’ class ERW 25 mm dia withnecessary fittings complete as per specification no. FF-PP
867Supplying and erecting G.I. pipe ζC’ class ERW 50 mm dia withnecessary fittings complete as per specification no. FF-PP
868Supplying and erecting G.I. pipe ζC’ class ERW 65 mm dia withnecessary fittings complete as per specification no. FF-PP
869Supplying and erecting G.I. pipe ζC’ class ERW 75/80 mm diawith necessary fittings complete as per specification no. FF-PP
870Supplying and erecting G.I. pipe ζC’ class ERW l00 mm dia withnecessary fittings complete as per specification no. FF-PP
871Supplying and erecting G.I. pipe ζC’ class ERW l50 mm dia withnecessary fittings complete as per specification no. FF-PP
872Supplying and erecting G.I. pipe ζC’ class ERW 200 mm dia withnecessary fittings complete as per specification no. FF-PP
873Providing coating of bitumen paint & 4mm thick wrapping forunderground 150 mm ring main of fire fighting system.
874Supplying and erecting 100 mm dia cast iron foot valve balltype/flap type with strainer for negative suction complete as perspecification no. FF-VL/FV
875Supplying and erecting 150 mm dia cast iron foot valve balltype/flap type with strainer for negative suction complete as perspecification no. FF-VL/FV
876Supplying and erecting 100 mm dia Cast Iron end line strainer ofY-type flanged end pattern, PN16 pressure rating, SS screen, endconnection with Flanged / Screwed / Socket Weld / Butt Weld Endetc with standard OAR (open area Ratio) for positive suctioncomplete as per specification no. FF-VL/ELS
877Supplying and erecting 150 mm dia Cast Iron end line strainer ofY-type flanged end pattern, PN16 pressure rating, SS screen, endconnection with Flanged / Screwed / Socket Weld / Butt Weld Endetc with standard OAR (open area Ratio) for positive suctioncomplete as per specification no. FF-VL/ELS
878Supplying and erecting 150 mm dia Cast Iron end line strainer ofTPot type flanged end pattern, PN16 pressure rating, screen of SSand end connection with flanged,for positive suction complete asper specification no. FF-VL/ELS
879Supplying and erecting 150 mm dia. cast iron double flange sluice valvecomplete with PN16 pressure rating, as per specification no. FF-VL/SV
880Supplying and erecting 200 mm dia. cast iron double flange sluice valvecomplete with PN16 pressure rating, as per specification no. FF-VL/SV
881Supplying and erecting 65 mm dia. cast iron double flangebutterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFV
882Supplying and erecting 75/80 mm dia. cast iron double flangebutterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFV
883Supplying and erecting 100 mm dia. cast iron double flangebutterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFV
884Supplying and erecting 150 mm dia. cast iron double flangebutterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFV
885Supplying and erecting 150 mm dia cast iron double flange NRVcomplete with PN16 pressure rating, as per specification no. FF-VL/NRV
886Supplying and erecting 25 mm dia gun metal gate valve completewith PN16 pressure rating, as per specification no. FF-VL/GV
887Supplying and erecting gun metal single outlet hydrant valve fittedwith necessary accessories complete as per specification no. FF-VL/HV
888Supplying and installing one piece moulded HDPE / fibre watertank for negative suction only, having capacity 1000 litres fittedwith necessary accessories complete as per specification no. FF-FFA/PT
889Supplying and installing wall mounting swinging hose reel drumfitted with 19 mm dia. 30m long high pressure polypropylene(Polyhose) along with necessary accessories complete as perspecification no. FF-
890Supplying and erecting 63mm dia, reinforced rubber lined(R.R.L.) hose pipe, 15m in length, fitted with necessaryaccessories complete as per specification no. FF-FFA/RRL
891Supplying and erecting stainless steel branch pipe 63 mm dia fittedwith 20 mm dia detachable hexagonal nozzle complete as perspecifications no. FF
892Supplying and erecting 150 mm dia fire brigade header suitablefor supplying water in fire tank complete as per specification no.FF-FA/FBC
893Supplying and erecting 300 mm dia 1.5m in height air vessel /tank fabricated from min 5mm thick M.S. sheet complete as perspecification no. FF-FFA/ACT
894Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve,erected with provided G.I. pipe, elbow etc. complete as perspecification no. FF-FFA/PG
895Supplying and erecting 12/15 mm dia pressure switch withprovided isolation valve, G.I. nipple, elbow, etc complete as perspecification no. FF-FFA/PS
896Supplying and erecting M.S./CRCA cabinet for housing FloorHydrant valve, hose pipe, hose reel and branch pipe (size 1000 x736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25x 4 mm. having front doors with viewing glass (8\\"x6\\") and lockingarrangement with necessary fixing material such as rubber biddingetc. duly painted in post box red colour( Code 538 of IS
897Supplying, erecting, testing and commissioning of quartzoid bulbsprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º Cfixed temperature rating with deflector disc of conventionalconstruction complete as per specification no. FF
898Supplying, installing, testing and commissioning of intelligentaddressable thermal/heat detector with rate of rise cum fixedtemperature thermistor complete with base as required, suitable fortemperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors,in built isolation mode, suitable for offices/ceiling cabletrenches/less ventilation area's etc. with 3 years equipmentreplacement warrantyIS : 2175 - 1988 reaffirmed 2000, IS15908:2021 standards FF-AFAS/SD.
899Supplying, installing, testing and commissioning of addressablemanual call points ( break glass type/pull station type), made ofaddressable break glass plastic square in shape surface/flushmounted with \\"Break Glass\\" massage embedded on the glass,complete erected with mounting base and required accessoriesconforming to EN 54 or UL listed with 3 years equipmentreplacement warranty FF-AFAS/MCP.
900Supplying, installing, testing and commissioning of addressablefire control/relay module complete as required, with 3 yearsequipment replacement warranty conforming to IS 5051Part 2 (Sec1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
901Supplying, installing, testing and commissioning of addressablehorn cum strobe sound/ hooter, output frequency 500 to 1000 Hzwith dB as per Chart given in IS 15908:2021, with flashing at 1 Hzover the strobe’s entire operating voltage range EN 54, conformingto IS 2189: 2008, IS 15908:2021 standards with 3 years equipmentreplacement warranty FF-AFAS/SSH.
902Supplying, installing, testing and commissioning remote responseindicators suitable to operate on 5 - 28 V dc supply having FRPolymer ABS Housing complete as per specification no. FF-FAAS/RRI
903Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel,central processing unit with the 4 loop capacity and capable ofsupporting upto 250 devices and detectors per loop, with on-boardLCD display with min 16 lines of text, operating at 230 V 50 HZ -AC with inbuilt Battery Backup of a minimum 24 hours in normalcondition and 30 min in alarm condition, suitable provision fornetwork connectivity, interfacing with third party equipment via aMODBUS/ OPC/ L-ON interfaceetc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS /FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
904Supplying, installing, testing and commissioning of repeater panelwith suitablebattery backup of a minimum of 24 hours in normalcondition and 30 min in alarm condition, 80 backlit alphanumericLCD display with inbuilt buzzer to indicate fault/fire alarm,manual control keys for silence/mute and to reset the FACP fromthe repeater station. Panel size shall not more than 175 x 275 x 65mm conforming to EN 54 or UL approved with 3 years equipmentreplacement warranty FF-AFAS/RP
905Supplying, installing, testing and commissioning FRLS, XLPEarmoured cable 2 core 1.5 sq.mm. copper conductor completeerected on wall/ ceiling completeas per specification no. CB-LT/CU (111=2% for FRLS)
906Making cement concrete foundation in 1:2:4 cement concrete withfoundation bolts and nuts complete. (cost of wooden box isincluded) (for pumps).
907Excavating soft murum / soft soil road by chiselling for preparingpit for poles stay or earth plates or for laying cables, pipes &clearing the site by removing debris & making the site goodcomplete.. (180x0.5x0.5)
908Supplying and erecting iron, sheet metal work consisting ofCRCA sheets, various sections of iron, plates, chequeredplates, rods, bars, MS pipes, etc. for panel board or anyother purpose with bending, cutting, drilling and weldingcomplete erected at the position with necessary materialsduly painted with one coat of red oxide and two coats ofenamel paint to match the switchgears or as per directions bythe authority.
909Supplying, erecting, testing & commissioning of fire pump controlpanel (FCP) of cubical construction, floor mounted type, fabricatedfrom minimum 2 mm thick CRCA sheet, compartmentalised withhinged lockable doors, with enclosure protection class IP54, dulypowder coated or painted with accessories dulypainted with twocoats of synthetic enamel paint of fire red colour over a coat ofprimer (ISC code 536 as per IS 2932 of 2003), cable alley,interconnection withsuitable size solid copper busbar strip ofadequate size for all power connections having switchgears andaccessories, mountings and internal wiring with adequate sizecopperconductor cable, earth terminals, numbering etc. complete inall respect, suitable for satisfactory operation of main fire pumpand jockey(pressurisation) pumps (1working+1standby) withnecessary accessories, wiring & cabling along with alliedaccessories with following incoming and outgoings, suitable forautomatic & manual operation on 415V, 3 phase, 50Hz ac supplyas per specifications the capacity of electric motor driven pump areas follows a. Main fire pump(MFP) having capacity of 22kW 1no(1 working) b. Jockey pump(JP) capacity of suitable capacity 2nos(1 working +1 standby, alternate run per start in auto mode)comprises of the following features & switchgears:1. Mainincomer FP SFU having rotary handle with HRC fuses of suitablerating.2. Electrolytic grade copper strips for busbar of suitablesizes for main incomer and branches to motor SFU's, starters &outgoing terminals with necessaryaccessories like stainless steelnut bolts with spring washers for connections, mounted onrequired no of epoxy or porcelain support insulators of suitableratings etc. 3. Individual pump TPN SFU having rotary handlewith HRC fuses of suitable rating.
9104. Digital voltmeter & ammeter & RYB indicating lamps & pushbuttons & SPP, O/L & phase reversal protection with emergencystop switch. 5. TPN SPD 100kA Type 1 +2 tested.6. Requiredpressure transducer with pressure indication on panel with cablingrequired for monitoring & automatic operation of fire pumps.7.System controller to control operation of main electric fire pump,jockey (pressurization) pumps in sequence with interlocking foroperation of pumps as per specification with automatic/manualoperation with selector switch & alternate run of standby Pumpsconsisting of relays, timers. sensors, annunciationwindow for faultindication, complete as per specification. 8.Suitable capacityelectric motor starters for all individual pumps with necessary pushbuttons & indications.9. Siren of required capacity to be activatedwhen main pump starts & allied accessories as per requirements oflocal CO or as directed by engineer in charge.10. Danger board asper IS. 11. Spare HRC fuses minimum 2nos of each individualrating with required bakelite fuse holder for main & jockey firepumps MFP=(1working), JP = (1working + 1standby, alternate runper start in auto mode) complete panel, as per specification no. FF-MFP/ECP
911Supplying and erecting ABC powder type fire extinguisher as perIS : 13849 / 15683 of 6 kg capacity with necessary clamp forerection on wall.
912Supplying erecting, testing and commissioning of sprinkler flexiblepipe of stainless steel complete with 15 NPT on reducer threadwith maximum working pressure of 175 PSI test pressure of 875PSI (Burst) with branch line (Inlet) 25mm NPT male thread tosprinkler head (Outlet) 15mm NPT female thread with reducer,nipple, 2 side brackets, center bracket, stockbar of 1000 mm size(UL Listed) complete as required as per specification no. FF-SPR/FHP
913Supplying, installing, testing and commissioning of Fire ExitSinages Acralic sheet with autoglow sinages.
914Supplying, erecting, testing and commissioning 120 Wamplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C.supply complete as per specification no. FF-PA/AFR
915Supplying, erecting, testing and commissioning 15 to 30 Wattssound column or ceiling mounted complete as per specificationno. FF-PA/SOC
916Supplying, erecting, testing and commissioning of 2 coreshielded cable complete as per specification no. FF-PA/MCC
917Supplying, erecting, testing and commissioning of 0.75 sq. mmspeaker wire complete.
918Supplying, erecting, testing & Commissioning of Alluminum Zink Pre-Fabricated Fire Water Tank (Dia - as per site )
919SCHEDULE B- ELECTRIFICATION WORK NORTH BUILDING
920Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
921SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
922Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
923Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
924Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or anyother places as per specification No: WG-MA/BW
925Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
926Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
927Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
928Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
929Supplying & erecting mains with 1X4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit)
930Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit earth)
931Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW (PDB & Main LDB Circuit)
932Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth)
933Supplying & erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (Main PDB Circuit)
934Supplying & erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth)
935Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
936Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
937Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
938Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
939Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
940Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
941Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
942Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
943Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
944Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background.
945Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
9461-w- Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/SW
9472-w- Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/SW
948Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
949Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
950Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WP W/CW
951Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary.
952Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light (excluding tube light).
953Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
954Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2
955Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
956Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
957Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
958Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
959Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
960Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
961Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
962Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
963Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
964Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
965Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
966Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
967Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
968Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
969Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
970Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
971Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
972Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI (Main MCCB PANEL-2, MLDB-1, MPDB-1, M Med Inst PDB-1)
973Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP.
974Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
975Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG
976Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (for ceiling Fn)
977Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standardlength with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
978Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
979Supplying & erecting four pole ON LOAD change over switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3...
980Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
981Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
982Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
983Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
984Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
985Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 80/100A in provided distribution board.
986Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
987Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
988Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
989Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
990Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
991Providing & erecting 4 Pole MCCB, 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/ MCCB
992Providing & erecting 4Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
993Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO
994Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO
995Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 8 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
996Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
997Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
998Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8)
999Sub - Work II -TELEPHONE & DATA SYSTEM
1000Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1001Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1002Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1003Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete
1004Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
1005Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
1006Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
1007Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
1008Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW
1009Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extension complete.
1010Sub - Work - III - AC UNIT INSTALLATION
1011Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
1012DRAIN PIPING
1013Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1014SCHEDULE B- ELECTRIFICATION WORK SOUTH BUILDING
1015Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1016SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
1017Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1018Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1019Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or anyother places as per specification No: WG-MA/BW
1020Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
1021Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1022Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1023Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
1024Supplying & erecting mains with 1X4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit)
1025Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit earth)
1026Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW (PDB & Main LDB Circuit) (Rs 103 x 2 = 206)
1027Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) (Rs 103 /2 = 51.50)
1028Supplying & erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (Main PDB Circuit)
1029Supplying & erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth)
1030Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1031Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
1032Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
1033Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
1034Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
1035Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
1036Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
1037Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
1038Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1039Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background.
1040Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
10411-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
10422-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
1043Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
1044Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
1045Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WP W/CW
1046Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary.
1047Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light (excluding tube light).
1048Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
1049Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2
1050Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
1051Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
1052Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
1053Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
1054Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1055Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
1056Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1057Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1058Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1059Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1060Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1061Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1062Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1063Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1064Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1065Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1066Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1067Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI (Main MCCB PANEL-2, MLDB-1, MPDB-1, M Med Inst PDB-1)
1068Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP.
1069Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
1070Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG
1071Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (for ceiling Fn)
1072Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standardlength with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
1073DISTRIBUTION SYSTEM
1074Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1075Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1076Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1077Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1078Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1079Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 80/100A in provided distribution board.
1080Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
1081Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
1082Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1083Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1084Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1085Providing & erecting 4 Pole MCCB, 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/ MCCB
1086Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO
1087Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO
1088Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
1089Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
1090Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
1091Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
1092Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8)
1093Sub - Work II -TELEPHONE & DATA SYSTEM
1094Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1095Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1096Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1097Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete
1098Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
1099Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
1100Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
1101Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
1102Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW
1103Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extension complete.
1104Sub - Work - II - AC UNIT INSTALLATION
1105Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8)
1106Sub - Work II -TELEPHONE & DATA SYSTEM
1107Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1108SCHEDULE B - LIFT INSTALLATION WORK
1109SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with· Rated capacity :- 15 Passenger/1020Kg· Floors :- G+3 floor (4 Stops/ 4 Landings) · Travel :- Travel :- 14.6 Rmt· Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS· Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· Clear Car size of 1200 mm wide x 2000 mm deep x 2000 mm high · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.\\"· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.\\"· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above Lft are includes Fully Comprehensive AMC for 5 year from the date of handing over· Lift shaft available having clear size of 2400 mm wide x 2900 mm deep , 1800 mm Pit depth, , 5100MM Overhead. Including Full Collective control system.
1110Total
1111Annual maintainnace contract for year 4 (1 Yrs included in rate)at 5 %
1112LIFT DUCT WIRING (Total Duct- 2 Nos)
1113Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (20 Rmt for 1 Lift)
1114Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 7 Rmt)
1115Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 7 Rmt)
1116Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 Rmt)
1117Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 Rmt)
1118Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (shaft-3 (bulkhead-1 & socket-1)x 2= )
1119Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (shaft - 1 )
1120Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. (Lift Room- 1 x 1= 1 x 3 = 3)
1121Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (Lift Room power- 1 x 1= 1 x 2 = 2)
1122Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. (Lift Room power- 1 x 1 = 1 x 2 =2)
1123Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected (shaft- 1 x 1 = 1 x 3 = 3)
1124Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW (Lift room-3 no)
1125Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW /CW (Lift Room- 1)
1126Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (Shaft 3 x 1= 3)
1127Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB (Lifr Romm power-1)
1128Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB (shaft Lighting-1, Romm SB-1)
1129Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SW-RCCB/RCCB (Lift Room 4-SPN enclosure)
1130Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. (4P RCCB-1, 2P RCCB+2SP MCB-1)
1131Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1132Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1133Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1134Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1135Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1136Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall /cable /conduit with screws complete. (8 SWG Tar- 0.116 kg / Rmt - 20 Rmt x 0.116 Kg/Rmt = 2.32 Kg x 1 Lifts)
1137Total
1138Annual maintainnace contract for year 4 (1 Yrs included in rate)at 5 %
1139SCHEDULE B- NORTH BLOCK IT WORK
1140Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
1141Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1142Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
1143Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ
1144Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK
1145SCHEDULE B-SOUTH BLOCK IT WORK
1146Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
1147Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1148Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
1149Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ
1150Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58563641
AUTHORITY Trust & NGO
TENDER VALUE Ref. Documents
LAST DATE 07-12-2026
Authority
Authority Name Shri Saibaba Sansthan Trust
Work Description Tender for Proposed Renovation Of Sainath Hospital, Shirdi For Shri Saibaba Sansthan Trust, Shirdi
Basic Detail
Tender No SSST/ Construction / 2026/103 / Renovation Work of Shree Sainath Hospital
Bidding Type Tender
Location
City Ahmednagar
State Maharashtra
Key Dates
Publish Date 20 Nov 2026
Submission Date 07 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 3540
EMD 7.50 Lakhs
Exemption Not Available
Document List
6e3eefd1-b556-46a2-b63e-c50ca31d8f32.html
BOQ_2311992.xls
North_Block_Drawing.pdf
Revised_Drawing.pdf
Tendernotice_1.pdf
Tender_Document_2026_103__1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

6e3eefd1-b556-46a2-b63e-c50ca31d8f32.html

xls

BOQ_2311992.xls

pdf

North_Block_Drawing.pdf

pdf

Revised_Drawing.pdf

pdf

Tendernotice_1.pdf

pdf

Tender_Document_2026_103__1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender