Tender for Development And Repair Renovation Of Government Etei, Balliguda In The District Of Kandhamal For The Year 2026-27 Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | Civil WorkRemoving old lime or cementplaster from walls including rakingout joints 12 mm deep andremoving the debris within 50mleadGround Floor |
| 2 | First Floor |
| 3 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor |
| 4 | First Floor |
| 5 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor |
| 6 | First Floor |
| 7 | 6 mm thick C.P. (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment , watering, curing cost, carriage & royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ref(A/R-2006,P-103,Item no-27)Ground Floor |
| 8 | First Floor |
| 9 | Finishing wall surface with Cement based wall putty (water based) of approved make and finished smooth & even surface to receive painting including cost of scaffolding etc. with cost of all materials, labour etc. complete.Ground Floor |
| 10 | First Floor |
| 11 | Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete.Ground Floor |
| 12 | First Floor |
| 13 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete.Ground Floor |
| 14 | First Floor |
| 15 | Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. Ground Floor |
| 16 | First Floor |
| 17 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the for reuse and removing the debris within 50m leadGround Floor |
| 18 | First Floor |
| 19 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. Ground Floor |
| 20 | First Floor |
| 21 | Providing and fixing ISI marked 35 mm thick flush door shutters confonning to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete . Ground Floor |
| 22 | First Floor |
| 23 | Priming one coat with any approved primmer including cost of primmer & labour to give an even shade excluding cost of primer. (As per A.R. 93/1) . Ground Floor |
| 24 | First Floor |
| 25 | Painting two coats with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. . Ground Floor |
| 26 | First Floor |
| 27 | Supplying, fitting, fixing of two track UPVC Sliding window (three tracK three pannel)track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with 6mm thick glass of approved quality complete with frame. Sutters and all fitting and fixtures . Ground Floor |
| 28 | First Floor |
| 29 | Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with water proof Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-chargeFirst Floor |
| 30 | Providing fitting fixing wooden panelling to walls, whereever necessary panelling will be done with 12mm & 19mm fire resistant & termite proof BWP ply (confirming to I.S 5509) wherever required to be provided and finished with 1mm thick laminate of approved shade and colour as per the drawing. The rate inludes cost of cut-outs, fixation,other accessories, labour T&P etc complete. First Floor |
| 31 | E.I WorkMajor/Manor Repair & MaintenanceRecessed wiring to light points / fan points/ Exhaust fan / call bell point with 1.5mm2 F.R.LS PVC insulated SC multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit with 5/6Amp., 250V Modular switch ISI marked and ceiling rose of ISI marked mounted an Modular G.I. box with Modular base and cover of suitable size (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) with 1.5sq.mm FRLS PVC insulated single core multistrand Cu. condoctor as earth wire including all accessories and connection. As per direction of Engineer in Charge. (Make of wire Finolex / KEI/ Polycab/ Havells) Group-A |
| 32 | Group-B. |
| 33 | Group-C. |
| 34 | Supply and fixing of 6Amp 3Pin modular socket with 6Amp modular switch on existing board. (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) |
| 35 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) |
| 36 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) |
| 37 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 01 no of 2 nos 6A switch & socket(modular type) ( flame retradant type) with suitable size modular box & metallic cover plate (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) |
| 38 | Supplying,fixing of 1x16A+1x6A Plug on the separate board with complete fitting by 01 no of 16A and 1 nos 6A switch & socket(modular type) ( flame retradant type) with suitable size modular box & metallic cover plate (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) |
| 39 | Supply and fixing of 3 nos. of 3 pin 5/6 amp modular socket and S.P. 5/6 amp one way modular switch, 1 no. of 5 pin 15/16 sockety out let and S.P. 15/16 A one way modular switch on modular G.I. Box with modular base and cover. (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) |
| 40 | Recessed wiring to submain in the following sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metalic heavy duty flexible conduit 1.6mm thick along with the following sq.mm FRLS PVC insulated single core multistrand copper conductor as earth wire as required. (Make of wire Finolex / Havells / KEI/ Polycab/ V-Guard). a) 1x1.5mm2 for Inverter wiring. |
| 41 | Supplying and fixing of 2 Module 18 swg of Modular G.I. Box including 6 Modular base & cover along with accessories in recessed wiringincluding cutting the wall and making good the same in case of recessed conduit as required. |
| 42 | Supplying and fixing of 4 Module 18 swg of Modular G.I. Box including 4 Modular base & cover along with accessories in recessed wiringincluding cutting the wall and making good the same in case of recessed conduit as required. |
| 43 | Supplying and fixing of 6 Module 18 swg of Modular G.I. Box including 6 Modular base & cover along with accessories in recessed wiringincluding cutting the wall and making good the same in case of recessed conduit as required. |
| 44 | Supplying and fixing of 8 Module 18 swg of Modular G.I. Box including 8 Modular base & cover along with accessories in recessed wiringincluding cutting the wall and making good the same in case of recessed conduit as required. |
| 45 | Supplying and fixing of 12 Module 18 swg of Modular G.I. Box including 12 Modular base & cover along with accessories in recessed wiringincluding cutting the wall and making good the same in case of recessed conduit as required. |
| 46 | Supplying and Fixing of Following Modular type Switch/Socket on the existing switch Box /Cover including connection etc as required . (Make Legrand myrius/ Schneider opale/ Crabtree veronana/ L&T Engleze.) a)5/6 Amp switch |
| 47 | b)15/16Amp Switch |
| 48 | c)3pin 5/6Amp Socket |
| 49 | d)6pin 15/16Amp Socket |
| 50 | Supplying and fixing of following sizes of medium class high strenth PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .MAKE KINJAL/ AKG/Anchor or equievalant reputed make A catagory ISI marked as approved. 20 MM |
| 51 | Supply and drawing of following sizes FRLS PVC insulated single core multistrand copper conductor in existing surface / recessed STEEL/PVC conduit as required. Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI a)3x1.5mm2 |
| 52 | b) 2x2.5mm2+ 1x1.5mm2 |
| 53 | c) 2x4mm2+ 1x1.5mm2 |
| 54 | d) 2x6mm2 + 1x2.5mm2 |
| 55 | Supply and Fixing of single pole and neutral, sheet steel, MCB distribution, 230V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, inter connections, phosphatized and powder painted including earthing etc. as required (But with out MCB/ RCCB / Isolator) (Make- L&T/ Legrand/ Schneider/ ABB) a) 4 way double door MCB box |
| 56 | Supply and fixing of 5amp to 32 amp rating 240V \\"C\\" series miniature circuit breaker suitable for lighting and other loads of the following poles in t he existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.(Make- Legrand/ L&T/ Schneider/Hager/Havells) a) 6Amp rating to 32Amp (SP) MCB |
| 57 | S/F of 32 A DP MCB in the existing MCB DB complete with connections(Make- Legrand/ L&T/ Schneider/Hager/Havells) |
| 58 | S/F of 40 - 63 A DP MCB in the existing MCB DB complete with connections(Make- Legrand/ L&T/ Schneider/Hager/Havells) |
| 59 | Supplying, installation, testing and commssioning of 1200 mm sweep white colour BLDC ceiling fan with aluminium blades having wattage 26-28 watt, BEE 5 star and air delivery GREATER THAN EQUAL TO 215m3/min Make-Crompton Energion Groove MODEL NO.CFENCHG480PW5S /Havells Efficiencia Neo MODEL NO. FHCNF5SWHT48/ Bajaj ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. |
| 60 | S/F of step type Modular electronic Fan Regulator |
| 61 | Supplying and fixing of call bell / buzzer ISI marked suitable for DC / AC single phase 230 volts complete as require. (Make- Cona / Anchor) |
| 62 | S/F. of 300mm accelero Hi-speed Wall mounted fan (Make Havells/ Usha / Bajaj /eq.)Replacement Warranty will be 2 years. |
| 63 | SITC of energy efficient LED tube light fittings having power rating 36 watt and lumen output not less than 110 lumen per watt complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 64 | Supplying,Erection,Fixing connection & testing of 40 W LED GATE light of maintenance free having 2 years warranty G.I pipe with bracket including MCB box & including with foundation (Make Crompton/ Bajaj/ Philips / Panasonic / Havells). |
| 65 | S/F. of 20 Wt. 210 x 210mm LED Square/Round recessed fitting (Philips / Panasonic / Havels/Jaquar) having output more than 110 luman per watt make.The luminaire should be Replacement Warranty will be 2 years |
| 66 | S/F of Bulk Head fitting CFL/LED type complete (Bajaj/Philips/Panasonic/ Havells with lamp) The luminaire should be Replacement Warranty 2 years |
| 67 | Supplying and fixing of 3pin, 5Amp ceiling rose ISI marked on the existing junction box / wooden block including connection etc. as required (Make Anchor/ Cona). |
| 68 | Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required |
| 69 | S/F of Street light- 90W CITYLINER NEO new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire more than 110 lumen per watt with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (with 5 Years Warranty) |
| 70 | Supplying, Erection, Fixing, connection & testing of 120W FLOOD Light of luminaire Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj maintenance free having 5 years warranty lumen efficacy not less than 120lm/watt with including MCB,stainless steel braket along with driver & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 71 | Supply, Installation, Testing and Commissioning of main switches (IS 13940 Part-3/1993 on existing surface / wall mounting and complete with HRC fuse links, interconnections, earthing etc. as required as per direction of Engineer In Charge. (Make- Anchor/ Cona/ Havells) a) 32 Amp ICDP M/S |
| 72 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power Armoured cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (KEI/POLYCAB/GLOSTER) 10 sq mm 4 core cable |
| 73 | 4 sq mm 3 core cable |
| 74 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power Armoured cable of following size suitable for 240 Volt, 1Ph, 50 c/s supply. (KEI/POLYCAB/GLOSTER)S/F of 6 sq mm 3 core cable ( |
| 75 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4 core x10 sq mm |
| 76 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 77 | Supplying & installation of 9'' or 225-230 mm sweep of exhaust fan (Make- Havells/Crompton/Usha/Orient/Bajaj) in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.(for kitchen) |
| 78 | Supply and Installation of 1.5 T 5 star rated Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type - Cooling only |
| 79 | S/F of 5 KVA (90Volt to 270Volt) Voltage Stabilizer of V-Guard / Autotake / CG/ Microctek make. |
| 80 | Supply,installation of hard/soft cu refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3corex4 sq mm FRLS cu control |
| 81 | supply, installation & fabrication of Insulated drain water piping from indoor to nearest drain point separate to all and other necessary material to complete the job 25 mm no. dia pipe |
| 82 | Supplying and installation of AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge . |
| 83 | S/F of 32Amp FTDP Switch with MS box.(Make anchor/legrand/Havells) |
| 84 | Campus LightingSupply of 7 mtr long single arm hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat as per direction of Engg. in Charge. |
| 85 | Supply and delivery of Galvanised round Arm with 1mtr long (Make Utkarsh/Bajaj/RR Ispat |
| 86 | Supply, delivery and installation of junction box with 16A MCB and 4way terminal box with provision for connection of earth and neutral on the 5mm thick fiber plate which will be kept inside the pole for termination of cable and wire. Make - Haeger /L&T/ Legrand / Siemens) |
| 87 | Foundation & erection of 7 mtr street lighting pole along with all materials & labour M20 concrete, as per direction of engineer incharge as per approved design |
| 88 | Supplying, Erection, Fixing, connection & testing of 120W FLOOD Light of Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj maintenance free having 5 years warranty lumen efficacy not less than 130lm/watt with including MCB,stainless steel braket along with driver & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 89 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 90 | SITC of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 91 | Providing and fixing 25mm x 5mm GI strip on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge |
| 92 | Earthing with GI earth pipe 3 meter long,40mm dia incluiding accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required |
| 93 | Providing and fixing swg 6 GI wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge |
| 94 | Power Back upSupply of 3.5 KVA, (1-Phase) silent DG Set . (Make-kirloskar). Specification: Genset Model KG4-P-3.5AS with Engine model CC418 G1 with rated output , sound level less than or equal to 75 db(A) , % THD (Voltage) equal to or less than 5 . This is electric start, compression ignition 230V and 4 stroke engine to run continuously. Radiator with fan, battery charging alternator 12 V DC battery,Dry type Air cleaner with service indicator, lube Oil & Fuel filter with Digital multifunction meter . |
| 95 | 63 A onload change over with encloser Make: Legrand/L&T/Schnider/Havells |
| 96 | S/F of 2300 VA , 24 V inverter machine sine wave Make Sukam/ microtek/Luminus with 3 years warrenty |
| 97 | S/F of Inverter Battery Tubular 12V 250AH (Make Exide / Amrom / Su-karm / Luminous with 60 Month warranty). |
| 98 | Supply, Installation of Inverter Battery trolly Make:( Microteck/Luminus/Su-Kam/Vguard) |
| 99 | Supply installation testing commissioning of 1 nos 3D LED/ACP Glow sign board size( 10ft x4ft) showing \\"GOVERMENT ELEMENTARY TEACHER EDUCATIONAL INSTITUTE, BALLIGUDA, DIST- KANDHAMAL WITH govt emblem/logo\\" as approved by the School and mass education dept. in English/ Odia language illuminated model desinged and complete power supply & wiriing and other accessories as per direction of engineer in charge Back ground material -ACP ( as per the approved govt. design font and colour) lettering- 3D Acrylic Raised LED letters Illumiantion-Module based LED backlighting Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender