Tender For Temporary Charging Of 220Kv & 400Kv Switchyards With The Help Of Available 33Kv Power Supply Through Installation Of 220Kv/ 33Kv Power Transformer At Ghavp Site.
Tender Value
2.45 Crore
Estimated cost
Bid Submission
07 Dec 2026
18 days left
EMD
4.90 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Temporary Charging Of 220Kv & 400Kv Switchyards With The Help Of Available 33Kv Power Supply Through Installation Of 220Kv/ 33Kv Power Transformer At Ghavp Site.
BOQ
| Sl. No. | Item Description |
| 1 | Shifting of 25MVA, 220/33kV transformer from TAPS-1&2 to GHAVP site including dismantling, oil draining, packing, loading, transportation, unloading, oil refilling, re-erection, testing, charging and commissioning, complete in all respects as per technical specification and site requirement. |
| 2 | SFRA testing of 25MVA transformer before shifting from TAPS-1&2 and after erection at GHAVP site |
| 3 | Supply, erection, testing & commissioning of 245KV 800A 300CT oil impregnated paper HT bushing as per specification |
| 4 | Supply of nitrogen Injection Explosion & fire prevention system for 25 MVA, 220/33 KV Transformer as per specification. |
| 5 | Supply of structure steel material for lattice tower (22.8mtr height) as per specification. |
| 6 | Supply of outdoor 36KV, 3 pole, 800A 25KA circuit breaker, 33KV Control and Relay panel of circuit breaker (1no.), 3 pole Outdoor 33KV Isolator (1no.), outdoor single phase 33KV LA (3nos.), outdoor single phase 33KV /110V Potential transformer (3nos.), outdoor single phase 33KV, 150-75A/ 5A Current transformer (3nos.), including GI structure of equipments as per specification. |
| 7 | Supply of 33KV overhead line, this work includes supply of all materials such as 33KV ACSR conductor, disc insulators, pin insulators, clamps, connectors, GI hardware, cross-arms, stay sets, earthing materials, lightning arrestors, isolators, line accessories, danger plates, phase plates, number plates and all associated fittings excluding 11mtr PCC poles, which will be free issue to the contactor as per specification. |
| 8 | supply of 3C*300Sqmm, 33KV Aluminium cable |
| 9 | Supply of 10core*2.5sq.mm, 1100 grade cable |
| 10 | Supply of ACSR Moose conductor as per specification. |
| 11 | Supply of 7/3.66 mm Galvanised steel earth wire. |
| 12 | Supply 216kV Outdoor, station class ZnO LA along with insulating base, discharge counter, leakage current meter, (mounting on high level structure). |
| 13 | Supply of insulator and String hardware, Spacers and Vibration Dampers, PG clamp, T Connector, Jumper Cone, dead end Assembly Suitable for Twin ACSR Moose Conductor |
| 14 | supply & installation of 33KV XLPE cable (3C*300Sqmm) termination kit (indoor) |
| 15 | supply & installation of 33KV XLPE cable (3C*300Sqmm) termination kit (outdoor) |
| 16 | supply & installation of 33KV XLPE cable (3C*300Sqmm) straight jointing kit |
| 17 | Supply & installation of cable accessories (Glands, Lugs as per applicable standard/code. |
| 18 | Supply & installation of cable tray of size 100mm Width x 75depth x1.6 thickness (Hot dip galvanized type) with all accessories and hardware |
| 19 | Supply & installation of earthing kit/earthing grid (as per IS 3043 specs) / Chemical Earthing for easy path to dissipate fault current as per IEEE 80:2000; Earthing resistance less than 1ohm. |
| 20 | Supply & installation of earthing Strip (GI Flat of 50mm x 6 mm) for system earthing. All welding work shall be done by qualified welder |
| 21 | Supply & fabrication, painting & installation of structure steel material for cable tray support |
| 22 | Supply & installation of Miscellaneous items like danger sign boards, insulation mat, CO2 fire extinguisher (22.5kg), fire buckets (10 Ltr. Capacity) with stand etc |
| 23 | Supply, installation of 40mm dia MS earthing conductor for transformer, tower & equipments earth grid including welding, supply and installation of hardwares etc., as required Note: The Installation charge shall include supply of all the required hardwares. |
| 24 | Erection of nitrogen Injection Explosion & fire prevention system for 5 MVA, 220/33 KV Transformer |
| 25 | Erection of structure material for lattice tower and 33kV outdoor equipments as per specification. |
| 26 | Erection of outdoor 36KV , 800A 25KA circuit breaker (1no.), 33KV Control and Relay panel of circuit breaker (1no.), Outdoor 33KV Isolator (1no.), outdoor 33KV LA (3nos.), outdoor single phase 33KV /110V Potential transformer (3nos.), outdoor single phase 33KV, 150-75A/ 5A Current transformer (3nos.) etc. |
| 27 | Erection of 33KV overhead line, this work includes erection of all materials such as 33KV ACSR conductor, disc insulators, pin insulators, clamps, connectors, GI hardware, cross-arms, stay sets, earthing materials, lightning arrestors, isolators, line accessories, danger plates, phase plates, number plates and all associated fittings including 11mtr PCC poles, at span of 40mtr without muffing. |
| 28 | Erection of 3C*300Sqmm, 33KV Aluminium cable |
| 29 | Erection of 10core*2.5sq.mm, 1100 grade cable |
| 30 | Stringing of ACSR Moose conductor |
| 31 | Erection of insulator and String hardware, Spacers and Vibration Dampers, PG clamp, T Connector, Jumper Cone, dead end Assembly Suitable for Twin ACSR Moose Conductor |
| 32 | Stringing of 7/3.66 mm Galvanised steel earth wire. |
| 33 | Erection of 216kV Outdoor, station class ZnO LA along with insulating base, discharge counter, leakage current meter, (mounting on high level structure). |
| 34 | Design, Construction of Transformer foundation including soak pit as per specification, including excavation, PCC, concreting (M-35), supply and placement of steel reinforcement and backfilling complete in all respect including vetting of foundation design from IIT or NIT professor. Note:- The natural ground level (NGL) at the transformer foundation location is 93.40MEL and the adjoining road level is 94.5MEL. The top level of transformer foundation shall be maintained 500mm above the road level i.e. 95MEL. The contractor shall accordingly carry out necessary filling, levelling to achieve the required finished foundation level. |
| 35 | Design, Construction of Tower foundation as per specification, including excavation, PCC, concreting (M-35), supply and placement of steel reinforcement and backfilling complete in all respect including fixing and setting of template 22.8 meter lattice tower, including vetting of foundation design from IIT or NIT professor. |
| 36 | Fencing of transformer and 33KV equipments yard, Supply, installation & civil work of chain link fencing of minimum height of 1.8mtr from ground level, in mesh size 50*50mm including strengthening with 2mm dia wire, made of GI wire of dia 4mm, PVC coated to achive outer dia not less than 5mm, The fencing shall be supported at regular interval of 3m or less, by MS angle as per specification. |
| 37 | Civil foundation work of outdoor equipments like 33KV LA, PT, isolator, CT (3nos.), C.B., 33kv control & relay panel & 216kV LA, including excavation, PCC, concreting (M-35), supply and placement of steel reinforcement and backfilling complete in all respect. |
| 38 | Civil foundation work of Cable tray support (i.e. ground mounted) with M-25 cement grade concrete |
| 39 | Gravel spreading in transformer & outdoor equipment yard area (150mm thickness), including anti weed treatment of top layer of soil before laying the gravel as per specification, drawing and direction of Engineer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender