Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #58558458

Tender For - Repair /Replacement Of Change Over Systems Surge Protection System And Connected Accessories At Adm Site And Lkt Area.

Issued by Statutory Bodies & Commissions/Committees · Nainital, Uttarakhand
Tender Value
4.30 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
14 days left
EMD
8600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nainital → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for - Repair /Replacement Of Change Over Systems Surge Protection System And Connected Accessories At Adm Site And Lkt Area.

BOQ

Name of Work:- – REPAIR /REPLACEMENT OF CHANGE OVER SYSTEMS SURGE PROTECTION SYSTEM AND CONNECTED ACCESSORIES AT ADM SITE AND LKT AREA.
Sl. No. Item Description
1Taking down exiting unserviceble TERCEL ISOPULSE surge protection device complete set model No IP200H3+E=N including secondary surge protection device from MRS adm site and LKT Tech site substation and repair replacement of the following parts refixing testing and commissioning and submission of test report including the following works.
2Supply and replacement and replacement of complete MOV protection PCB assembly, compatible with existing TERCEL ISOPULSE equipment, including MOVs, thermal disconnection /protection arrangement, associated electronic components and connectors.
3Supply and replacement and replacement of complete secondary protection PCB assembly, compatible with existing equipment, including associated electronic components and connectors.
4Supply and replacement and replacement of complete main protection PCB assembly, compatible with existing equipment, including associated electronic components and connectors.
5Supply and replacement and replacement of internal protection fuses of identical specified type, voltage, current rating and breaking capacity.
6Supply and replacement of internal connecting wires, suitable insulation sleeves, ferrules, cable lugs and terminal connectors for restoration of internal wiring.
7Supply and replacement and replacement of defective filtering capacitors of identical/equivalent approved specification.
8Dismantling and removal of defective PCB assemblies and associated components, including safe isolation, identification and tagging of conductors.
9Supply replacement Installation, fixing and reconnection of MOV protection PCB assemblies, including correct polarity/phase identification and torqueing of terminals.
10Supply replacement Installation, fixing and interconnection of secondary and main protection PCB assemblies, including restoration of control wiring.
11Supply and replacement /termination of internal wires, fuses, cable lugs, ferrules and terminal connectors, including crimping and insulation finishing.
12Cleaning of enclosure, PCB mounting area, busbars, inductors and terminals; removal of dust/loose deposits and tightening of accessible connections.
13Electrical inspection, testing, functional verification and commissioning of repaired SPD assembly, including status/alarm indication checks and submission of test report.
14Supply and replacement of manual onload change over switch front operated 4 pole (3 pole + Neutral) 415 V AC including sheet metel enclosure 100 A including taking down old burnt change over complete all as specified and directed. Make- TRONIC CO 4100- EC or equivalent in Havells IHCNFE0100/HPL /L&T
15Supply and replacement of manual onload change over switch front operated 4 pole (3 pole + Neutral) 415 V AC including sheet metel enclosure 200 A including taking down old burnt change over complete all as specified and directed. Make- TRONIC CO 4200 or equivalent in Havells IHCNFE0200 insta shift/HPL /L&T
16Supply and replacement of manual onload change over switch front operated 4 pole (3 pole + Neutral) 415 V AC including sheet metel enclosure 400 A including taking down old burnt change over complete all as specified and directed. Make- TRONIC CO 4400 or equivalent in Havells IHCNFE0400 insta shift/HPL /L&T
17Design, fabrication, installation and testing of LT out door type factory made(CPRI Approved), junction box for surge protectin device of size 500mm(H)X700mm(B)X400mm(W) (over all dimension) made out of 3.0mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary aluminium lungs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-1 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence grey) RL-35 after neccesary preparation of surfaces including Indicating lamp LED type 240V 50 Hz AC -one set of 3 Make: L&T/Legrand/ ABB/Siemens/Havells compete all as directed including taking out old unserviceable LT Panel board..(a) INCOMING: MCCB 4 pole 100 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No Make: L&T/Legrand/ ABB/Siemens/Havells (b) OUTGOING: MCCB 3 pole 63 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -01 Nos Make: L&T/Legrand/ ABB/Siemens/Havells (c) O/G MCB SPN 32 Amp, 10KA,C curve - 02 Nos . Make: Legrand cat No 408683 or equivalent model of L&T/ ABB/Siemens/Havells. (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3 .Make: L&T/Legrand/ ABB/Siemens/Havells
18Supply and replacement MCCB 4 pole 16 KA 125 A complete all as specified and as directed.
19Supply and replacement MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA
20Supply and replacement MCCB 3 Pole .415 V. fixed type, 200 Amps with breaking capacity 16 KA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58558458
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 4.30 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for - Repair /Replacement Of Change Over Systems Surge Protection System And Connected Accessories At Adm Site And Lkt Area.
Basic Detail
Tender No 8031
Bidding Type Tender
Location
City Nainital
State Uttarakhand
Key Dates
Publish Date 17 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 4.30 Lakhs
Tender Fee 500
EMD 8600
Exemption Available
Document List
993a8c04-613d-4786-9add-19909315bde1.html
BOQ_896434.xls
Tender8031.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

993a8c04-613d-4786-9add-19909315bde1.html

xls

BOQ_896434.xls

pdf

Tender8031.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender