Tender For Special Repairs To Bldg Nos Xl And Lxviii Of Mh Wellington Under Ge Wellington 8342/E8
Tender Value
43.50 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
16 days left
EMD
87000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nilgiris → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repairs To Bldg Nos Xl And Lxviii Of Mh Wellington Under Ge Wellington 8342/E8
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of single layer Mangalore pattern tiles or similar pattern tiles on roof all as specified and directed. |
| 2 | Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced exceeding 15cm all as specified and directed. |
| 3 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 4 | Galvanised, corrugated mild steel sheeting 0.63mm with two corrugation side lap fixed with coach screw and washers, in roofs walls etc. with grade of zinc coating 275 all as specified and directed. |
| 5 | Labour only for 0.63mm Galvanised, corrugated mild steel sheeting with two corrugation side lap fixed with coach screw and washers, in roofs walls etc. with grade of zinc coating 275 including fixtures and washers and consumable items except sheets all as specified and directed. |
| 6 | Second class hard wood, clean sawn, battens, exceeding 5Sqcm and not exceeding 15Sqcm in cross section, spaced at 30 cm centres all as specified and directed. |
| 7 | Fixing only for Second class hard wood, clean sawn, battens, exceeding 5Sqcm and not exceeding 15Sqcm in cross section, spaced at 30 cm centres all as specified and directed. |
| 8 | Dismantling of timber scantling 40 sqcm and over in sections in any position in chajjas as in unframed works, complete all as specified and directed. |
| 9 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed. |
| 10 | Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering and on chajjas etc fixed with self tapping screws all as specified and directed. |
| 11 | Second class hardwood as in scantling clean swan, purlins, rafters etc fixed to timber frame work complete all as specified and directed |
| 12 | Preparation of wooden surfaces and applying two coats creosete oil over wooden surfaces all as specified and directed. |
| 13 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and directed |
| 14 | Demolition of cement concrete ( unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level ) etc complete all as specified and directed |
| 15 | 25 mm thick Plain cement conncrete 1:2:4, type B-0 using 12.5mm graded stone aggregates as in base concrete to floor complete all as specified and directed. |
| 16 | Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed. |
| 17 | Coloured Non - skid Ceramic joint free tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in dado/ Skirting etc. and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 18 | Glazed ceramic tiles in vertical surfaces 450mm x 350 x 7mm / 350mm x 250mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick plaster in cement mortar 1:3 on fair face of brick/ stone or concrete surface complete all as specified and directed. |
| 19 | Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed. |
| 20 | Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets and frame work all as specified and directed. |
| 21 | GI frame work for grid of size 605mm x 605mm seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55 thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed. |
| 22 | Providing and fixing 12 mm thick Gypsum Board in ceiling fixed with screws as per manufacturers instructions complete all as specified and as directed. |
| 23 | Applying two coats of distemper oil emulsion on new ceilings surfaces over priming surfaces with alkali resistant priming paint over one coat of 3mm thick putty including preparation of surfaces complete all as specified and as directed. |
| 24 | Taking down chowkhats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutters from frame) all as specified and as directed. |
| 25 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 26 | Factory made UPVC white colour sliding window three track, area not exceeding 2.00 Sqm each made of extruded profiles with wall thickness of 2.3mm (± 0.2mm) window profile with hollow section with multi chamber frame (88mm x52mm) sliding sash (42mm x 67mm) sliding mesh sash (42mm x 57mm) sliding interlock (one vertical length in each shutters) (45.5mm x 28mm) Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware EPDM gasket, 1.2 (± 0.2mm) thick galvanised steel frame (30mm x 18mm) 2 Nos sliding sash (30mm x 18mm) sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, hardware (Touch Lock of zinc alloyed (white powder coated) steel roller system inclusive of stainless stell wire cloth 0.36mm nominal dia of wire and average width of aperture 140mm and required accessories all as specified and directed.Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose. |
| 27 | Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube,supplying and fixing in opening as per specification and drawing all as specified and directed. |
| 28 | Factory made solid panel PVC door shutter 30mm (Style) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame all as specified and directed. |
| 29 | Taking down chowkat or frame with shutter (without taking off shutters from the frames) area exceeding 1.5 Sq mtr but not exceeding 4 Sq mtr each all as specified and directed. |
| 30 | 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue, pinned at joint all as specified and as directed. |
| 31 | 35 mm thick flush shutter, solid core construction, with block Board Core and plywood face panels one face is covered with decorative Face Veneer with lipping/ frame to match, complete all as specified and as directed. |
| 32 | Butt hinge, 100 mm long medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 33 | Extruded aluminium alloy handles 150 mm long, fabricated type, anodised complete all as specified and as directed |
| 34 | 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 35 | Aluminium anodised, barrel tower bolts of extruded section 150 mm long all as specified and directed. |
| 36 | Demolition of cement concrete reinforced in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 37 | Reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies deck slabs and in shelves and similar work complete all as specified and directed. |
| 38 | Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete flat complete all as speicified and directed. |
| 39 | Mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers, binders, etc complete all as specified and directed. |
| 40 | Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed |
| 41 | Pre-cast cement concrete block masnory with solid block using type C1, 1:3:6 using 20mm graded stone aggregate exceeding 10cm in width and setting in mortar 1:6 complete all as specified and directed |
| 42 | Supply and fix in repairs Sink with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified and directed. |
| 43 | Taking up or down steel tubing and connections for 15mm bore pipe including cleaning for refixing or removing from site all as specified and directed |
| 44 | Taking up or down steel tubing and connections for 20mm bore pipe including cleaning for refixing or removing from site all as specified and directed |
| 45 | Supply, laying and testing steel water tubing 15mm medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc) complete all as specified and directed. |
| 46 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etcand making good, cutting not exceeding 10cm grith complete all as specified and directed. |
| 47 | Supply laying and testing steel water tubing medium grade galvanized with all GI fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor including cutting and chasing and making good with all fitttings complete all as specified of size 20 mm bore. |
| 48 | Vitreous china wash down water closet pan (pedestal pattern) white with P or S trap incl flushing pipe , seat and PVC seat cover (white) closed pattern with flat bottom & cover brass chromium plated hinging device, incl connection to drain and to flushing pipe, antisyhonage pipe etc and including fixed in repairs complete all as specified and directed. |
| 49 | PVC low level flushing cistern 10 litres capacity, valveless, syphonic action type, white, with inlet ball valve, float and handle including connecting to bracket etc fixed in repairs complete all as specified and directed. |
| 50 | Vitreous china wash basin, white, flat back, size 550mm x 400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, with and including brass chromium plated perforated waste coupling / fittings 32mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, PVC waste pipe of 32mm bore and of suitable length, 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and PVC connection 15mm size with PTMT nuts of length 450mm and fixed in repairs complete all as specified and directed. |
| 51 | Bib tap fancy type chromium plated fixed to 15mm bore in repairs complete including fixed in reapirs all as specified and directed. |
| 52 | Stop valves, fancy type, 15mm bore chromium plated with long shank and cup concealed type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair all as specified and directed. |
| 53 | Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated,15mm bore including fixed in repairs all as specified and directed. |
| 54 | PVC connections 15mm size with PTMT nuts of length 450mm and fixed in repairs complete all as specified and directed. |
| 55 | Chromium plated 125mm shower rose with or without swivel joint, size, including fixing to steel pipe or union, fixed in repairs complete all as specified and directed. |
| 56 | Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position including fixed in repairs complete all as specified and directed. |
| 57 | Sheet Glass shelves assembly corner consisting of 5.5mm thick sheet glass shelf 12cm wide with chroumium plated bracket guard and railing 60cm long and fixed in repairs complete all as specified and directed. |
| 58 | Supply and fix in repairs of Chromium plated soap dish complete all as specified and directed. |
| 59 | Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges including fixed in repairs all as specified and directed. |
| 60 | PVC (SWR) floor trap 75mm outer dia, plain with grating including jointing to waste pipe with solvent cement dia of outlet 75mm complete all as specified and as directed. |
| 61 | Grating doom 100mm dia of PTMT (minimum weight 25gms) fixed in repairs complete all as specified and as directed. |
| 62 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, and removing same from the site(s) complete all as specified and as directed. |
| 63 | Rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 and 5mm thick in cement mortar 1:4 over a coat of 10mm thick finished even and smooth (without using extra cement) mixed with water proofing compound complete all as specified and as directed. |
| 64 | Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work / concrete surfaces in walls finished even and smooth without using extra cement compete all as specified and directed |
| 65 | Preparation of old decorated plastered or unplastered surface of ceiling by brooming down or steel wire brushing scraping down smoke spots, moulds, moss and efflorescent and trading oil and greasy spots etc and applying two coats of white wash on ceiling complete all as specified and directed. |
| 66 | Preparation of old decorated plastered or unplastered surface of walls by brooming down or steel wire brushing scraping down smoke spots, moulds, moss and efflorescent and trading oil and greasy spots etc and applying two coat of white wash on walls complete all as specified and directed. |
| 67 | Complete removal of existing treatment of wall surfaces and applying two coats of Oil Bound Distemper (washable) over a coat of primer (water thinable/ solvent thinable), over one coat of white wall care putty even and smooth complete all as specified and directed. |
| 68 | Preparation of newly plastered surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10Sqm over new surfaces complete all as specified and directed. |
| 69 | Preparation of newly plastered surfaces of walls and applying two coats of oil bound distember over one coat of priming plastered and other surfaces with alkali resistant primer over one coat of 3mm thick wall care putty complete all as specified and directed. |
| 70 | Preparation of old painted steel surfaces and steel based materials of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 71 | Preparation of old painted wooden surfaces and wood based materials of any description not other wise over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 72 | 600 mm x 450 mm thick bevelled edges looking mirror of selected quality glass, mounted on 6mm thick AC building board or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete fixed in repairs all as specified and as directed. |
| 73 | Fancy type decorative drapray rod 20 mm dia Aluminium powder coated including side caps and brackets, as in repairs complete all as specified and directed. |
| 74 | 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of flooring and finished even and fair complete all as specified and directed. |
| 75 | Chequered cement concrete colour tiles 30 cm x 30 cm x 20-22 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors, steps etc over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 76 | Machine Pressed precast concrete interlocking paver block rubberised any shape and size conforming to IS- 15658 - 2006 of 60 mm thickness M-35 Grade with grey cement and pigment including 50mm thick sand bed complete all as specified and directed. |
| 77 | Granite slab 20mm thick machine cut, laid over screed bed, bedding and jointed grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15mm thick screed in cement mortar 1:4 all as specified and directed. |
| 78 | PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses, etc and similar work including necessary form work complete all as specified and directed. |
| 79 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed. |
| 80 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, layer complete all as specified and directed |
| 81 | Removing of excavated soil/ material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 82 | Stone Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 and pointing the dressed surface with same mortar as the work proceeds all as specified and directed. |
| 83 | All as per item No 82 hereinbefore but except stone all as specified and directed. |
| 84 | Extra over stone walling for Granite or Trap stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm all as specified and directed. |
| 85 | Keyed pointing to random or polygonal rubble masonry uncoursed or brought upto courses in cement mortar (1:4) all as specified and as directed. |
| 86 | UPVC SWR pipe single socketed in any length with rubber ring joint 100mm dia as in weep holes all as specified and directed. |
| 87 | PCC type C1, 1:3:6 using 20mm graded stone aggregate as in coping and the like including necessary form work all as specified and directed. |
| 88 | Taking down PVC/ CI pipe jointed in cement mortar, taking out wall and eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc. (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed |
| 89 | PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed. |
| 90 | PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. |
| 91 | PVC (SWR) 110mm dia bore pipe single socketed in any length, with rubber ring joint fixed to walls with PVC clamps complete all as specified and directed. |
| 92 | PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls with PVC clamp, complete all as specified and as directed. |
| 93 | PVC (SWR) bend of any radius 110 mm dia with access door complete all as specified and as directed. |
| 94 | PVC (SWR) bend of any radius 75 mm dia with access door complete all as specified and as directed. |
| 95 | Ball valve/ float valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20mm dia (minimum weight 25mm-455gms) complete all as specified and directed. |
| 96 | Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm dia fixed in repairs all as specified and directed. |
| 97 | Dismantling PVC water tank exceeding 250 ltrs and not exceeding 500 Ltr capacity from existing position all as specified and as directed. |
| 98 | Rotational moulded polyethylene water storage tank 3 layered of capacity 1000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position with proper inlet and outlet connections all as specified and as directed |
| 99 | Stainless steel plate track of size 0.9 X 1.2 m and fixed in repairs complete all as specified and as directed. |
| 100 | Taking down aluminium/ copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell etc, and making good disturbed surfaces with smooth finish matching with the existing surface of walls, floors, etc. all as specified and directed. |
| 101 | Material and labour for Point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, sheathed stranded copper conductor single core cable 1100 volts grade in and including PVC conduit medium grade in concealed complete with conduit fittings/ accessories including 1.5 sqmm FRLS grade PVC insulated sheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed.Note: 1. Sunken box/ Cover plate for modular plate for modulat switches, sockets etc will be measured and paid separately under relevant items and blank plate required if any will be deemed included in the item rate.2. Cutting chases in stone masonry wall will be measured and paid separately. |
| 102 | All as per Item No 101 hereinbefore but One 3 pin 5A Socket outlet on same board complete all as specified and directed |
| 103 | All as per Item No 101 hereinbefore but One 3 pin 5A switch socket outlet on independent Board all as specified and directed. |
| 104 | All as per Item No 101 hereinbefore but point wiring complete with 2.5 sqmm FRLS cable for 3 pin 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed. |
| 105 | Ceiling rose, 3 terminals PVC / polycarbonate, isolated body all as specified and directed. |
| 106 | Modular switch one way 6A 230V AC 50 HZ SP one module all as specified and directed. |
| 107 | Modular switch one way 16A 230V AC 50 HZ SP one module all as specified and directed. |
| 108 | Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified and directed. |
| 109 | Modular socket 2/3 pin combined 6A/16A 230V AC 50 HZ SP two module all as specified and directed. |
| 110 | Modular Metal Flush Box 1/2 module rectangular block for mounting, switches, sockets, fan regulator all as specified and directed. |
| 111 | Modular Metal Flush Box 3 module rectangular block for mounting, switches, sockets, fan regulator all as specified and directed. |
| 112 | Modular Metal Flush Box 4 module rectangular block for mounting, switches, sockets, fan regulator all as specified and directed. |
| 113 | Modular Metal Flush Box 6 module rectangular block for mounting, switches, sockets, fan regulator all as specified and directed. |
| 114 | Modular White Cover Plate with Frame White cover plate with frame, 1 module all as specified and directed. |
| 115 | Modular White Cover Plate with Frame White cover plate with frame, 2 module all as specified and directed. |
| 116 | Modular White Cover Plate with Frame White cover plate with frame, 3 module all as specified and directed. |
| 117 | Modular White Cover Plate with Frame White cover plate with frame, 4 module all as specified and directed. |
| 118 | Modular White Cover Plate with Frame White cover plate with frame, 6 module all as specified and directed. |
| 119 | Taking down unserviceable DBs with MCBs and Supply and fix MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed. |
| 120 | 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 32 AMPs SPN in the MCB DB complete with connection testing and commissioning all as specified and directed. |
| 121 | All as per item No 120 hereinbefore but SP 6 to 32 AMPs capacity all as specified and directed. |
| 122 | Taking down unserviceable DBs with MCBs and Supply and fix MCB DB TPN 4 way 415volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed. |
| 123 | 415V, 10 KA 'C' curve miniature circuit breaker (MCB) of TPN/FP 40to 100 AMP current carrying capacity in the DB Complete with connection testing and commissioning all as specified and directed. |
| 124 | Taking down unserviceable FTL fittings, Supply and fix 25W LED 125 Lum/Watts 4ft batten comprises of thermally conductive material pre-wired with high efficiency electronic driver, high translucent serrated milky white diffuser gets glare free, smooth light distribution lamp colour white all as specified and directed.Make. Havells Cat Part No. LHEXAWPN7IN1W025 or equivalent make in CG/ Philips / Bajaj. |
| 125 | Taking down unserviceable 2ft FTL fitting Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC 125 Lum/Watt decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make - Havells Cat Part No-LHEXACP5IN1W010 or equivalent in Philips/CG/Orpit |
| 126 | Taking down unserviceable LED dimmable LED panel size 595mmx595mm, 40watt, 6000K, 100 Watts/ Luman, 220V AC surface mounted type with high efficiency PMMA diffuser soft glare free light coplete with drivers, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Luker Product code- LPSD40/ Halonix code - HLFPR22-11-40-CW-37mm-WC or equivalent techno commercial make. |
| 127 | Taking down old unservicable indoor wall light fittings and supply and fixing of aesthetically designed indoor wall light with E-27 holder without lamp complete all as specified and directed.Make: Luker Product code- LWL31-1 or equivalent techno commercial make. |
| 128 | electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC connection piece etc. all as specified and directed.Make: Crompton/ Bajaj/ V Guard/ Racold / venus |
| 129 | Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 10A SP MCB all as specified and directed. Make-Legrand/ABB/Havells |
| 130 | Taking down Submain wiring with aluminium conductor along with PVC Conduit and Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.Note: 3 runs of cable and one run of conduit pipe together measured as one RM |
| 131 | Cutting chases in Brick / stone masonry wall for laying GI pipe or concealed conduit wiring and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exceeding 10cm girth all as specified and directed |
| 132 | Supply and fix exhaust fan steel body AC single phase 230V of size 300mm sweep with blades and frame and louvers including making opening brick/ ston masanory wall as per requirement of Exhaust fan and make good and matching with existing surface complete all as specified and directed. |
| 133 | Material and labour for LED Security Light fitting of 35 Watt comprising of eposy powder coated housing enclosed with glass cover in frame with protection IP 65/66 complete with all accessories and lamp colour white, 110 lumen/ watts all as specified and directed. |
| 134 | GI Pipe Medium Grade 32 mm bore bracket of suitable size bent to shape of not less than 1.2m long with clamp made of GI flat Iron of size 32 x 6mm for street light fittings, duly painted with one coat of red oxide primer and two coats of aluminium based paint, fixed on poles with bolts, nuts and washers including taking down old brackets complete all as specified and directed. |
| 135 | Supply, lay and testing cable XLPE insulated armoured heavy duty electric cable with aluminium multi strands conductor, 1100 volts grade, cross-sectional area 10 Sq.mm 4core complete all as specified and directed. |
| 136 | Excavation in trenches not exceeding 1.5 meter deep and not exceeding 1.5 meter wide and gettting out in Soft/ Loose soil for laying of under ground cable, and foundation of poles, etc complete all as specified and as directed. |
| 137 | Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as specified and directed.Note: Punned thickness only will be measured and paid. |
| 138 | Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm all as specified and directed. |
| 139 | GI Pipe light grade 40 mm dia for cable protection in trenches/ at PCC pole for loopin/loop out of cable and cable entry at Bldg/ block end including taking down all as specified and directed |
| 140 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical platee No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS bars at 100mm c/c, funnel, watering pipe etc. all as specified and directed including testing on completion. |
| 141 | Schedule of Credit (Minus) Rs. 48510.00 NOTE: Bidder shall insert credit amount of Rs. 48510.00 as rate in Green field under Col-5. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender