Tender For Installation And Energisation Of Duked-Ii, Harlanga-Ii And Nagjhori-Ii L.I. Project Under M.Rampur Block In Kalahandi District Out Of Ridf-2026-27
Tender Value
98.82 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
18 days left
EMD
98824
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kalahandi → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation And Energisation Of Duked-Ii, Harlanga-Ii And Nagjhori-Ii L.I. Project Under M.Rampur Block In Kalahandi District Out Of Ridf-2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation of foundation in hard soil such as hard stiff clay,stiff black cotton,hard red earth,shales,moorum ordinary gravels etc. including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. (Excavation by mechanical means 60% and manually 40%) |
| 2 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 3 | Filling the foundation and plinth in hard soil with excavated material in layers not exceeding 0.30m including breaking of clods within 50m initial lead including lavelling the trenches as the case may be etc. complete as directed by the Engineer-incharge quality of means of mechanical 60% & manually 40% i.e. of respective item no. 1 |
| 4 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. i.e. respective of item no.2 |
| 5 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 6 | Cement concrete (1:3:6) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 7 | Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 8 | Brick work with Fly Ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. |
| 9 | Brick work with Fly Ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in Super Structure etc. complete as per the Engineer-incharge. |
| 10 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 11 | Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 12 | Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.(a)R.C.C. foundation and Plinth bend and footing bases of columns, mass concrete, pre-cast slabs etc. |
| 13 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 14 | Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500) |
| 15 | Wall painting 2 coats with cement paint of approved shade on new work over coat of primer to give an even shade including cost of paint. |
| 16 | Distempering two coats to walls with distermper of approved shade on new work to give an even shade including cost of distemper & labour etc. complete. |
| 17 | Cost of 47mm dia steel pipe of length 6.1Mtr for Stainless steel Display board |
| 18 | Cost of thick steel plate of 4mm thick of size for Stainless steel Display board |
| 19 | Cost of Fabricated M.S door & Window of Size 1.2x1.98 M & 0.60 X 0.75 M including trnsportation form work shop to work site and painting of door with approved paint 2 coat including cost of paint |
| 20 | Cost of C.C Ventilator (size 0.45x0.30m) |
| 21 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing and stickering on the satinless steel display board etc. complete as per the direction of the Engineer-incharge. |
| 22 | Supplying of 200mm dia HDPE Pipe (PE-80 PN -4) including Pre & Post delivery CIPET Testing Fees |
| 23 | Supplying of 160mm dia HDPE Pipe (PE-80 PN -4) including Pre & Post delivery CIPET Testing Fees |
| 24 | Supplying all materials, labour, T&P for jointing of 200 mm outer dia High Density Polythylene Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge |
| 25 | Supplying all materials, labour, T&P for jointing of 160 mm outer dia High Density Polythylene Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge |
| 26 | 12.5 HP/9.375 KW Energy efficiency Monoblock pump set of total head 20 mtrs having discharge 1700 LPM with squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges Class \\"F\\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery= 100mmx100mm with BEE 3 Star rated energy efficiency Pump as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares confirming to IS specification (a) Casing: FC 200 as per IS 210/1978 (b) Impeller: Bronze grade LTB-2 of IS 318/1981 including all Taxes excluding cost of GST |
| 27 | Control out door Pannel with Automatic Star delta Starter,6KVAR Capacitor,63Amp Main switch, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 15 HP with 20 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter, Ameter, MCB in complete shape including Indicator Lamp reputed brand of ISI specification with 4nos, MS Leg including all Taxes excluding cost of GST |
| 28 | Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray / navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board. |
| 29 | Base Plate made of MS Channel with holes |
| 30 | 3x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below 0 .9mtr. of the ground and filling the excavated materials including watering and ramming. |
| 31 | 4mm² 3 core submersible flat cable of ISI |
| 32 | 100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark. |
| 33 | 100 mm dia G.I. bend IS No.1239(Part-II/1992) |
| 34 | 100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand |
| 35 | 100 mm dia G.I. flange IS No.6392 / 1971 |
| 36 | 100 mm Ø Sluice Valve Flanged type of Manufacturing Standard - BS 5163 / IS14846 Pressure Ratings PN10. |
| 37 | 100mm Non-return valve C I double flanged swing type PN - 1.0 as per IS:5312 part-I with by-pass arrangement |
| 38 | 219mm MS Pipe with plain ends in random length of 4 to 7 mtrs. Confirming to BIS 3589 with minimum wall thickness of pipe should be 5.5mm each pipe should bear ISI specification and manufacturers name/trade mark.Steel grade of pipe should be Fe330. |
| 39 | Cost of 219mm MS/Steel Flange |
| 40 | Welding,laying & fitting of 219mm dia MS Pipe |
| 41 | 150mm dia C.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022) |
| 42 | 160X160X110mm dia G.I. outlet Tee made with 151mm ID and 159 mm OD GI Pipe of 8mm thick 400mm long fitted with 1 mtr long 100mm dia G.I.Pipe welded with 2 nos of 100mm dia G.I.Flange in between the 1 mtr G.I..Pipe and 0.25 mtr long 100 mm dia G.I. Pipe fitted horizentally with 2 mtrs of 100mm dia G.I. Elbow with water locking arrangement made out of 1 no. of 100mm dia open flange and 1 no. of 100mm dia blind flange and with hinges gaskets arrangement that HDPE pipe should be inserted directly 100mm long inside the 151mm dia ID G.I.Pipe at the both ends . |
| 43 | Cost of 200x200x160 mm spigot moulded reducing HDPE Tee 10 kg |
| 44 | Cost of 200mm HDPE Tail piece 160 mm long |
| 45 | Cost of 160mm HDPE Tail piece 160 mm long |
| 46 | Cost of 200mm dia HDPE elbow spigot design 6kg |
| 47 | 200 mm Ø slipon flange |
| 48 | 160 mm Ø slipon flange |
| 49 | 200 mm Ø HDPE End Cap |
| 50 | 160 mm Ø HDPE End Cap |
| 51 | Cost of River Bank cutting & shaping for const. of P.F. |
| 52 | 50 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark. |
| 53 | 100x100x25mm G.I. Tee with Plug with 25x50mm GI Reducer and 50mm Ball Valve |
| 54 | Cost of 200 mmx160 mm HDPE Reducer |
| 55 | Cost of 200x100mm M.S. Reducer (fabricated ) |
| 56 | 5/8 ' x12\\" Nut bolt & washer F.T. for foundation |
| 57 | 5/8 ' x3\\" Nut bolt F.T. as per IS specification |
| 58 | 1/2\\" x2 1/2\\" Nut bolt F.T.as per IS specification |
| 59 | ⅛\\" thick Rubber Insertion as per IS specification |
| 60 | Cost of 160x160x160 mm spigot moulded reducing HDPE Tee 10 kg |
| 61 | Labour charges for installation of 10/12.5/15HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge. |
| 62 | Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation with 3.6mtrx3mtrx1.5mtr height masonary boundary wall /G.I. Flat fencing boundary wall with Flat with Polymer insulator ,L.T Dist Box with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of 40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including 25KVA BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 400 kg 10 mtr long PSC pole,transformer hard channel top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5) A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices all other necessary fittings i.e required size Nuts Bolts, Brackets, Cable, Cable Sockets as per TPWODL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection commissioning as per specification of TPWODL etc complete. |
| 63 | Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 400 kg 10 M long PSC Pole with 55 Sqmm AAA Conductor average span 50mtr , 11 KV \\"V\\" Cross arm required No.of 11 KV T C Disc. polymer Insulators in tension point 11 KV Pin Polymer insulators, Couping Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required. including cost of all materials, labour transportation,inspection commissioning etc. complete including all Taxes excluding cost of GST. |
| 64 | Construction of 3 Phase L.T line as per REC standard confirming to RE rule 1956 with 300Kg 9 Mtr long PSC pole support in 0.30M span length with 3x35mm² +1x25 mm ² LT, XLPE AB cable with coil earthing device, LT dead end clam, Suspension clamp with G I hook , stay accessories such as wire insulator , clamp etc. nut bolts, alongwith concreting copping padding of poles and stayset as per direction of Engineer in Charge including all Taxes excluding cost of GST. |
| 65 | Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps ,nuts & bolts, cable socket etc. including excavation of earth pits 2 Nos of size 1200mm X1200mm X 3200mm for fixing of earthing pipe 2 Nos of size 40mm dia X 3000 mm length with required slotting in pipes & fittings with 40 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work and pannel wiring with required 4mm2/2.5mm2 PVC coper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge |
| 66 | Construction of 11 K.V.Tapping Pole/Interposing pole with 10 mtr. PSC pole including cost of construction, construction materials involved, transportation of materials involved, taxes and cess ect complete excluding GST. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender