Housing Urban and Rular Development Government Departments Closing in 1 days TDR #58557552

Tender For Construction Of Art Craft Room At High School Lidroo Advt.Cost=₹ 17.46 Lacs, Amount Without Gst= ₹ 14.80 Lacs, Gst Amount= ₹ 2.66 Lacs

Issued by Government Departments · Anantnag, Jammu and Kashmir
Tender Value
17.46 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
1 days left
EMD
34920
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Art Craft Room At High School Lidroo Advt.Cost=₹ 17.46 Lacs, Amount Without Gst= ₹ 14.80 Lacs, Gst Amount= ₹ 2.66 Lacs

BOQ

Name of Work:- Construction of Art Craft Room at High School Lidroo Advt.Cost=₹ 17.46 lacs, Amount without GST= ₹ 14.80 lacs, GST amount= ₹ 2.66 lacs
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
2Providing & Laying of stone soling nallah boulders hand packed tightly including ramming watering and filling of interstices incl all carriage complete job.
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
4Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
5Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
6Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
7Centering and shuttering including strutting, propping etc. and removal of form for : A) Foundations, footings, bases of columns etc. for mass concrete.
8B) Suspended floors, roofs, landings, balconies and access platforms.
9C) Lintel, beams, plinth beams, girders, bressumers and cantilevers.
10Brick work with FPS bricks of class designation 75 in foundation & plinth in cement mortar 1:6 (1 cement , 6 coarse sand) i/c extra for Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto floor V
11Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported K.Wood.
12Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).35mm thick imported wood
13Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: in imported wood
14Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge: imported wood 35mm thick
15Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size)
1615mm Cement plaster on the rough side of single or half brick wall 1 : 6 ( 1 cement : 6 fine sand)
1712 mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) including all necessary carriages complete job.
18Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown
19Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent.
20Extra for providing glass panes of ordinary glass panes windows and clerestory window shutters wt 10 Kg/sqm (Area of opening for glass panes excld portion inside shall be measured) 3.5 mm
21Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick
22Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications
23Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
24Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
25Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm
26Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more.
27Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded
28P/F track deck crill make or equivalent H.I rib color coated profiled sheets 1000 to 1020mm cover width 28-35mm high crests at 250 to 255mm TCT (total coated thickness) high tensile SMP Galvalume steel with silicon modified ployester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of SMP over 5 micron polyester back coat over 5 micron primer coats on both surfaces incld. side and end lap and using 8mm galvalume hex self drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all side and end laps etc. (measured for unit of laid area)0.50mm THICK (TATA DURASHINE, JSW COLORON PLUS OR EQ) I/C ALL CARRIAGES)
29Providing ridges of hips of width 60cm overall width color coated plain sheets fixed with self drilling screws with EPDM Seal complete: 50 mm thick
30Providing and fixing plained eaves boarding. Imported kail wood 250x 32 mm ( nominal size) i/c paintwork
31Providing and fixing soffit under roofs i/c framework using 0.35mm ribbed color coated profile sheets complete.
32P/F of ISI marked ornamental aluminium (coated) hardware fittings i/c all fastenings completei) L- drop with lock
33ii) Handles 200mm
34iii) Handles 100mm
35iv) T Bolts 100mm
36v) T Bolts 150mm
37vi) Hooks
38Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
39Engagement of JCB for site clearance levelling of ground and work of similar nature, platform cutting.
40Carriage of materials by Mechanical Transport from source to site of work for an avg lead of 30kma) Sand/Bajree
41b) Bricks
42P/F PVC conduits 25 mm dia (Finolex or equivalent)
43P/F Light Junction blocks complete as directed at site
44P/F fan junction blocks complete as directed at site
45ElectricWiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS/HFFR PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) including the cost of conduit.
46Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
47Supply, installation, testing and commissioning of 1200 mm (48”) BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340–380 (as per manufacturer’s specification), power consumption not exceeding 50 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty.
48Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with GI flush box, including wiring connections, testing and commissioning, of approved make such as Anchor Roma / Legrand / Schneider / Havells, complete as per direction of the Engineer-in-Charge.
49Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10°C to +45°C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
50Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
51Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
52Wiring for AC/Power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK) including the cost of conduit.
53Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit.
54Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
55Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
56Supply and fixing of 12 way, Double door surface/ recess mounting, Horizontal type,SPN, sheet steel, MCB distribution board ,220V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB)
57Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCBdistribution board complete with necessary connections.
58Supply, installation, testing and commissioning of 40A-32A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
59Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
60Main PanelDesign, fabrication, supply, installation, testing, and commissioning of Main Distribution Board (MDB), duly manufactured from CPRI-approved manufacturer, made out of 12 SWG CRCA (IS 375) mild steel sheet, 2 mm thick, powder-coated with RAL 7035, floor/wall-mounted, vermin and dust-proof, indoor type. The panel shall be provided with suitable size angle iron legs for grouting in the ground, lockable hinged doors, and painted finish. The enclosure shall have provisions for fixing switchgears,Aluminium bus bars of various ratings (considering derating factor), and other allied accessories as required. The panel shall be fabricated as per approved design; size may vary according to site requirements. The panel shall fully comply with IS 8623 / IEC 61439 standards for low voltage switchgear assemblies.The work includes all internal wiring, thimbles, ferrules, nuts, bolts, washers, gland plates, earthing lugs, insulation sleeves and all other accessories necessary to complete the panel in all respects as per site requirements.”
61Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.1. Normal INCOMING:a)100A DP MCB 10 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation..
62b) 4 No. of Aluminium Bus Bar of 200 Amp.
63c)Digital meters and phase indicators -1 set.
642.INVERTER a) 32A DP MCB 10KA
65b) 2 No. of Aluminium Bus Bar of 63 Amp.
66c) Digital meter and phase indicators 01 set.
67Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). 2x 6 sq mm + 1x 6 sq mm Heating submain
682x 4 sq mm + 1x 4 sq mm Inverter submain
692x 2.5 sq mm + 1x 2.5 sq mm inverter & normal Circuit
70Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job.
71Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
72Supplying,Laying and fixing of Suitable Fan Junction Box in Slab.sample to be approved by EIC
73Providing and fixing of Deep boxes for lights in Slab,sample to be approved by EIC
74Supply, laying, connecting and commissioning of 10 sq mm 2 core XLPE/ PVCInsulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58557552
AUTHORITY Government Departments
TENDER VALUE 17.46 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Art Craft Room At High School Lidroo Advt.Cost=₹ 17.46 Lacs, Amount Without Gst= ₹ 14.80 Lacs, Gst Amount= ₹ 2.66 Lacs
Basic Detail
Tender No ENIT NO Fresh 122 OF 2026-27 DATED 16-11-2026
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 17 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 17.46 Lakhs
Tender Fee 800
EMD 34920
Exemption Not Available
Document List
BOQ_1124705.xls
e20cefe8-2dfa-4fa8-9868-0328c5880b29.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1124705.xls

html

e20cefe8-2dfa-4fa8-9868-0328c5880b29.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender