Tender For maintenance Of L.I. Scheme At Gakulpur-I Under Purba Gakulpur Gp Of Tepania R.D. Block During The Year 2026-27/ Sh: Shifting Of Pump House And Allied Works In/C. Pump Motor Sets And Electrical Equipments Etc. Complete.
Tender Overview
Project Description
Tender for maintenance Of L.I. Scheme At Gakulpur-I Under Purba Gakulpur Gp Of Tepania R.D. Block During The Year 2026-27/ Sh: Shifting Of Pump House And Allied Works In/C. Pump Motor Sets And Electrical Equipments Etc. Complete.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering.-All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick ggregate 40 mm nominal size) |
| 5 | First class brick work in foundation and plinth including cost of all materials as required complete:-i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 6 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.a) Hot finished welded type tubes |
| 7 | Providing & fixing of fabricated post made of 100 mm dia medium class MS pipe (9.75 kg/mtr) 3.00 mtr long fitted with 3 nos. 75x45x6 mm cleat and 2 nos. 200x200x10mm gusset plate at top and bottom including cutting making necessary holes in the gusset plates, welding etc. complete (excluding nuts & bolts) as per direction of the Engineer- in- Charge. |
| 8 | Providing & fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design. |
| 9 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.A) Fixed to steel windows by welding. |
| 10 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engg-in-charge.a) 0.63 mm thick with zinc coating not less than 275gm/m2 |
| 11 | Providing and fitting G.C.I sheet (0.63 mm thick) for walling including Vertical/curved surface fixed with galvanized steel J or L hooks 8 mm diameter, bolts and nuts with bitumen and G.I limpet washers or with G.I. limpet Washers filled with white lead and including a coat of appoved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal / Verticle or curved surfaces) excluding the cost of G.S. sheet purlins rafters & trusses and including cutting to size and shape wherever required as per direction of Engg-in-Charge. |
| 12 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.a) Using flats 30x6mm for diagonal braces and central cross piece. |
| 13 | Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement)i) R.C.C grade M-20 (1:2:4) (Nominal mix)a) upto 5 m height |
| 14 | Reinforcement for R.C.C. work in/c. straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement)a) P.C.C grade M 20 (using jhama brick aggregate) (i) Nominal mix (1:2:4) |
| 16 | Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. all complete as per direction of Engineer-in-charge.i) 40 mm thick with 20 mm well burnt brick aggregate. |
| 17 | Painting with synthetic enamel paint (one or more coats) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engg-In-Charge. |
| 18 | Plastering with cement mortar (1:4) 12 mm thick on brickwork/ C.C. work including a finishing coat of neat cement punning with 2.75 kg of cement per sqm in substructure as per MoRD technical specification Clauses 613.4 & 1204 |
| 19 | Complete earthing of dia. 60 cm.for all pump sets & panel board with 8/10 Sqg.Wire length not less than 10 mtr.) and 40 mm.dia. G.I.pipe of length 2.5 mtr. welded with a funnel at top and providing holes @ 10 cm. c/c covering length 1.50mtr. from bottom alongwith charcoal (14cft) and salt (150kg) to be placed from bottom in an alternate layer (10cm. for salt & 30 cm. for charcoal) as per direction of the Engg-in-Charge. |
| 20 | Providing and laying of G.I Pipe with fittings complete as per direction of the Engineer-in-Charge.a) 40 mm dia. (For Priming line) |
| 21 | Providing and fitting fixing brass fullyway valve with handle in the G.I Pipe line including cutting threading etc complete, as per CPWD Specification and direction of the Engineer in charge. |
| 22 | Providing and fixing G.I Bend / Elbow in the pipeline including testing of joints complete as per CPWD specification and direction of the Engineer in charge |
| 23 | Providing and fixing G.I equal tee with the pipeline including testing of joints complete as per CPWD specification and direction of the Engineer in charge |
| 24 | Providing and fixing G.I union as per CPWD Specification and direction of the Engineer in charge |
| 25 | Providing and fitting fixing of full threaded nuts and bolts of different size of approved quality as per direction of the Engg-in-charge |
| 26 | Providing and fixing G.I. pipes of Heavy class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. A. Extenal Work.i) 150 mm. dia. normal bore - For Suction Line |
| 27 | i) 125 mm. dia. normal bore - For Delivery Line |
| 28 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality.i) 150 mm.dia. |
| 29 | ii) 125 mm.dia. |
| 30 | Supplying & fitting fixing of GI . bend of approved quality.i) 150 mm.dia. |
| 31 | ii) 125 mm.dia. |
| 32 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.i) 150 mm.dia. |
| 33 | ii) 125 mm.dia. |
| 34 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality.i) 150 mm dia. |
| 35 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality.i) 150 mm dia. |
| 36 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality.i) 150 mm dia. |
| 37 | Providing & fitting fixing MS tail piece with MS flange suitable for pipes complete as per CPWD Specification & direction of Engineer-incharge.i) 150 mm dia. - Suction |
| 38 | Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge. |
| 39 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality of 7/16 Copper Wire. |
| 40 | Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge. |
| 41 | Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items in/c. 2 nos. MS angle post (Size 50x50x6mm 2.80 Mtr. long) nuts & bolts etc. for errection of the same by 1 : 1.5 : 3 cement concrete casting (1feet x 1feet x 2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engg-in-Charge. |
| 42 | Supplying and fitting fixing of Indicator bulb (Flush type containig 3nos batton holder with bulb) on the panel board of approved quality. |
| 43 | providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge. |
| 44 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. |
| 45 | Installation of pump motor set including carriage of materials from Departmental store yard to site of work and making necessary electrical connection with main switch / starter with motor in/c. commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender