Tender For Annual Preventive Maintenance Of 66 Kv Substation Thithki And Associated Transmission Lines
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Dec 2026
22 days left
EMD
25000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Preventive Maintenance Of 66 Kv Substation Thithki And Associated Transmission Lines
BOQ
| Sl. No. | Item Description |
| 1 | Preventive maintenance of 66 KV substation Thithki consisting of 2×15 MVA (66/33 KV) transformers, 06 no. 66 KV bays, 08 no. 33 KV indoor bays by carrying out following miscellaneous works on routine basis and round the clock availability of a team comprising the following technical personal-(i) Technician/ fitter - 01 No.(ii) Skilled coolie/ line man - 01 No.(a) Routine visual checking of red hot points, flashpoints, burned jumpers etc. in switchyard. General routine maintenance of outdoor equipments/panels in switchyard i.e. CBs, isolators, bus bars, CTs, PTs/CVTs, marshalling kiosks etc. including scheduled cleaning, lubrication, tightening of connections/jumpers, replacement of minor damaged parts of equipments, replacement of jumpers/clamps/connectors etc. as per direction of engineer incharge.(b) Routine cleaning of all type of transformers, their marshalling boxes, OLTC etc., maintenance of cooling fans i.e oiling, greasing, cleaning etc., LT electrical connections, tightening of loose connections as per direction of engineer incharge.(c) Routine checking of complete length of control cables and power cables between indoor panels/equipments and outdoor equipments/kiosks/panels, cleaning, replacement of damanged/burned cables, tightening & replacement of damaged terminals/connections/lugs etc., re-ferruling whenever required.(d) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room & battery cells, maintaining fluid level, specific gravity, applying of petroleum jelly etc. as per direction of engineer incharge.(e) Routine maintenance of indoor panels in control room i.e. control & relay panels, ACDB & DCDB system, indoor & outdoor illumination system etc. including scheduled cleaning, lubrication, tightening of connections/terminals, replacement of minor damaged parts of panels, tracing of circuits etc. as per direction of engineer incharge.(f) Attending minor breakdowns such as replacement of damaged jumpers, replacement of burnt and damaged equipments (bus bar, isolators, CT/PT/CVT) parts, replacement of burnt/damaged CT/PTs, replacement of damaged/burned HT/LT connections and peripherals etc. excluding works which require equipment specific technical expertise and special T&P etc. such as repair of transformers, CBs etc. as per direction of engineer incharge.(g) Any other routine substation electrical maintenance related works assigned by engineer incharge as and when required. |
| 2 | Work of Patrolling of the following lines- |
| 3 | 66 KV D/C Thithki-Roorkee Line (10 times x 9 = 90 km) |
| 4 | 66 KV D/C Thithki-Mohammadpur Line (10 times x 10.1 = 101 km) |
| 5 | Work of lopping - chopping of the trees under and near the line gallery for following lines- |
| 6 | 66 KV D/C Thithki-Roorkee Line (4 times x 9 = 36 km) |
| 7 | 66 KV D/C Thithki-Mohammadpur Line (4 times x 10.1 = 40.4 km) |
| 8 | Work of Thermoscanning of the 66 KV lines which includes thermoscanning of all tension towers, jumpers, clamps, connectors etc. of the following 66 KV lines: |
| 9 | 66 KV D/C Thithki-Roorkee Line (10 times x 9 = 90 km) |
| 10 | 66 KV D/C Thithki-Mohammadpur Line (10 times x 10.1 = 101 km) |
| 11 | Work of replacement/jointing of broken/damaged jumper of above mentioned line and proper tightening. Work should be complete in all aspects. |
| 12 | Work of jointing/attending the broken/damaged earth wire with span joint and stringing work of 66 KV lines. Work should be complete in all aspects. |
| 13 | Replacement work of damaged discs of suspension towers of 66 KV lines which includes the work of dehoisting of the suspension string, replacement of defective insulator and refixing of string. Work should be complete in all aspects. |
| 14 | Replacement work of damaged disc of tension towers of 66 KV lines which includes the work of dehoisting of tension string, replacement of defective insulators and refixing of string. Work should be complete in all aspects. |
| 15 | Work of removing the bushes, small trees etc near tower legs, checking of tower leg earthings and attending the same if found broken and removing the extra soil from the coping of tower foundations. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysDec 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender