Tender For Repair And Maintenance Of A) 210 Trainee Capacity Hostel Building (Ajintha) And 3 Classrooms Building (Dnyansagar) At Police Training Centre, Jalna B) 210 Trainee Capacity Hostel Building (Verul) And 3 Classrooms Building (Gurukul) At Poli
Tender Overview
Project Description
Tender for Repair And Maintenance Of A) 210 Trainee Capacity Hostel Building (Ajintha) And 3 Classrooms Building (Dnyansagar) At Police Training Centre, Jalna B) 210 Trainee Capacity Hostel Building (Verul) And 3 Classrooms Building (Gurukul) At Police Training Centre, Jalna .C) Mess Building And 3 Classrooms Building (Dnyanganga) At Police Training Centre, Jalna.D) 64 Qtrs At Tisgoan From Mhada For C.P. Chh.Sambhjinagar.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | Providing and applying priming coat on concrete / masonary / Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. |
| 3 | Providing and applying external raincoat painting with crack filling acrylic polymerbased chemical compound coating to the external surface of walls to prevent waterseepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint,removing loose particles of sand on the surface opening and cleaning the cracksdeveloped in the external plaster, removing loose particles by chiseling, fillingcracks by chemicals compound of approved make with proper penetration etc.Coating of Raincoat with the help of brush and as per instructions and specificationgiven by manufacturer and with instruction from Engineer in- charge. Work shall beexecuted by certified applicator only and covering gurantee of 3 years on court stamppaper of Rs. 500/- and necessary testing etc. complete. |
| 4 | Providing and applying two coats of waterproof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering fortwo days etc. complete. |
| 5 | Providing and applying plastic emulsion paint of approved quality, colour and shade to oldand new surfaces in two coats including scaffolding, preparing the surface.(excluding the primer coat)etc. complete |
| 6 | Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding,if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. |
| 7 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etcetra complete |
| 8 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 10 years guarantee on Stamp Papers etc. complete. |
| 9 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS.15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, fillingjoints, curing and clearing etc. complete. |
| 10 | Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc.complete. |
| 11 | Removing W.C.pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed concrete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls outsid eetc.carefully and throwing out the refusal outside etc. complete. |
| 12 | Providing and fixing1st class white glazed earthenware OrissaTypeW.C.Pan 580mm dia including P or S trap cast iron soil and vent pipe upto the out side face of the wall (1:5:10) cement concrete bedding15mm thick,10 liter P.V.C.flushing cistern with all necessary pipe connection etc. complete. |
| 13 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete. |
| 14 | Removing doors and windows with frames and stacking the materials as directedwith all leads, lifts etc. complete. |
| 15 | Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. |
| 16 | Providing and fixing green marble of 18 to 20 mm thick for door frame /dado/ window boxing etc.On C.M.1:6 including filling joints with polymer base filler nosing /moulding the sharp edges wherever necessary, curing, etc. complete. |
| 17 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. |
| 18 | Removing urinal pans or wash hand basins with frame including disconnecting thesanitary and water supply connections, removing the same carefully and stackingthe serviceable materials as and where directed including throwing the unserviceable materials outside etc complete. |
| 19 | Providing and fixing white glazed earthen ware lipped flatback/corner type Urinal with PVC 5liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall |
| 20 | Providing and fixing white glazed earthenware Wash Hand Basin of 45cmx30cm size including cold water pillartap /cold and hot water pillar tap brackets,rubber plug sand brass chain,stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete |
| 21 | Providing and fixing in position powder coated aluminium louvered windows/ ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. |
| 22 | Providing and Fixing SS Hinges 125mm Ht, 14 Gauge Heavy Duty |
| 23 | Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc.complete as per sample approved by Engineerin-charge. |
| 24 | Removing chockes and leakages from down take G.I /CI/PVC pipe line on walls floor level by using zoola/ scaffolding and rectify the same for functioning with all lifts etc.complete. |
| 25 | Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types ,of exterior grade, as per detailed drawings, conforming to I.S.:2202-1962 (Revised) with approved face veneers on both faces with/ without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping ,hold fasts, mat finish stainless steel fixtures fastenings, finishing with french-polish /waxing complete.(without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter |
| 26 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and No. ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 27 | Providing, laying and fixing P.V.C .pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 28 | Manually clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. |
| 29 | Providing and fixing reinforced cement concrete cover of size 60 cmx 45 cm with frame over inspection chamber etc. complete. Heavy duty (160 Kilogram) |
| 30 | Providing and fixing reinforced cement concrete cover of size 90 cmx 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) |
| 31 | Providing and constructing Brick Masonry Inspection Chamber 60cmx 45cmx 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, BrickMasonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram with frame etc complete. |
| 32 | Providing and constructing Brick Masonry Inspection Chamber 90cmx 45cmx 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, BrickMasonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogram with frame etc complete. |
| 33 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group DII-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white /colour cement slurry cleaning curing etc. complete. |
| 34 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection upto the out side face of the wall |
| 35 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 36 | Painting letters required height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. |
| 37 | Laboratory Testing Charges Cement (Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial & Final), Compressive Strength, Soundness) |
| 38 | Laboratory Testing Charges Sand/Fine Aggregate (a) Fineness Modulus strength |
| 39 | Laboratory Testing Charges Sand/Fine Aggregate (b) Silt Content |
| 40 | Laboratory Testing Charges Ceramic Tiles/Vitified Tiles (Water absorption, Modulus of Rupture (Set of 6 Tiles) |
| 41 | ELECTRICAL INSTALLATION |
| 42 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 43 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 44 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 45 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 46 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 47 | SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 48 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 49 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 50 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 51 | Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 52 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 53 | Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 54 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places.as per specification No: WG-MA/BW |
| 55 | Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit) |
| 56 | Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit earth) |
| 57 | Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW (PDB & Main LDB Circuit) ( |
| 58 | Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) ( |
| 59 | Supplying & erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (Main PDB Circuit) |
| 60 | Supplying & erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) |
| 61 | Supplying & erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (Main PDB Circuit) |
| 62 | Supplying & erecting mains with 1x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) |
| 63 | Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 64 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 65 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 66 | Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. |
| 67 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 68 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 69 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 70 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 71 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 5 years warranty. |
| 72 | Supplying and erecting rectangular shaped LED Panel Light(1200mm X 300mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 73 | Supplying and erecting electronic type driver for indoor LED 19W-24W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 74 | Supplying and erecting electronic type driver for indoor LED 25W-40W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 75 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 76 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/FLS2 |
| 77 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 78 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 79 | Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 5 Years warranty as per specification No FG-ODF/FLS2. |
| 80 | Rewinding the motor of the Exhaust fan 900 / 1400 RPM 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year |
| 81 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 82 | Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. |
| 83 | Supplying and erecting condenser 2.5 micro farad for ceiling fan |
| 84 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF, with 5 years warranty. |
| 85 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 5 years warranty. |
| 86 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 87 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 88 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 89 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (2 Run from Feeder panel to Meter) |
| 90 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 91 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG |
| 92 | DISTRIBUTION SYSTEM |
| 93 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 94 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 95 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 96 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 97 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 98 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO |
| 99 | Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 100 | MAIN PANEL/DB |
| 101 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 102 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 103 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 104 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 105 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 106 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 107 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. |
| 108 | TELEPHONE CABLE & IT'S OTHER WORK |
| 109 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 110 | Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S. Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW (main telephone cable |
| 111 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 112 | Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW (main cable) |
| 113 | Supplying, erecting & Commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 114 | NETWORKING & IT'S OTHER WORK |
| 115 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 116 | Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. |
| 117 | COMMON WORK |
| 118 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 119 | AREA LIGHTING |
| 120 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 121 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 122 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (Street Light Pole) |
| 123 | Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box. |
| 124 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (for all street Light pole) |
| 125 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL (for street LightPanel supply) |
| 126 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (for all street Light pole cable protetion) |
| 127 | ELECTRICAL MOTOR PUMP |
| 128 | Rewinding of electric motor above 3 H.P.upto 5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 129 | Rewinding of electric motor above 2 H.P. upto 3 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 130 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/ centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . (for all pump) |
| 131 | Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. (for all Pump) |
| 132 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL |
| 133 | Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only (FOR EACH PUMP) |
| 134 | LIFT WORK |
| 135 | Providing annual Fully Comprehensive Maintenance contract for liftsProviding annual Fully Comprehensive Maintenance contract to 4 No of Lifts-DERRICK Make Lift 06 Passenger lift (G+4) capacity each Lift microprocessor based, Type of Machine-_____ , Door Opening_______, Load welght-408 KG. That serve G+4 Floor, at location with monthly visit of trained technical staff and maintenance contract with replacement of parts to keep the lift in perfect working conditioning as per the terms and condition of the lift. (For 1 Years) Ensure smooth running of lifts. 1) Attending the breakdown calls immediately on the same day. 2) If the breakdown of Lifts not attended on the same day, the maintenance cost will be deducted on daily basis from the bill. 3) This Fully comprehensive maintenance includes cleaning and maintenance of machine, control panel along with repairs (replacement if required) mechanical & electrical parts & components such as locks door bearing, Gibbs car and landing push button, final limit switch, cabin shoe limit switch, break coil & break liner, maintenance of up and down system over speed governor, safety put stop switch including contractors, over load relay, replacement of fully charged Batteries if required and monthly servicing. 4) Separate log book shall be kept for the lift. Each & Every breakdown, repairing & Servicing shall be recovered in the log book. 5) Carrying out preventative maintenance & Servicing of lifts in every month. 6) Attending the annual inspection carried out by inspector of lifts. 7) Examine fortnightly all safety devices, Governers & make all the customary safety tests. 8)Renew all the wire ropes as often as required to maintain an adequate factor of safety to equlise the on all hoisting ropes repair / replace conductor hoist way cables machine room & elevator wiring .9) If the breakdown is not attended within 24 hours’ penalty charges of 400/- per day per lift will be deducted. Note:- AMC charges shall be applicable only when the lift is in working condition. If the lift is not in working condition, the contractor shall inform the Engineer-in-Charge accordingly. Any repair work required shall be approved separately by MSPHC. |
| 136 | D.G WORK |
| 137 | Providing Fully Comprehensive Annual Maintenance for 125 KVA Silent D.G.set . SCOPE OF WORK :-1) Servicing of each DG set at least once in month and as & when required with no extra charge. 2)To attend all the break down calls with Replacement of batteries as and when required 3) To maintain the log book of each servicing & repairing of each DG set 4) Inspecting engine & carrying minor adjustment repairs as per necessary. 5) Checking tappet clearance if necessary 6) Checking lubricant oil condition & replacing as & when required. 7) Checking lubricant oil filters 8) Checking & cleaning pre-cleaner assembly lubricant oil filters 9) Checking bolt alignment & bolt tension as per requirement & resetting time to time. 10) Checking generator coupling. 11) Checking radiator water level & cleaning as per requirement. 12) Checking and inspecting of batteries & its waterlevel, add distilled water, if necessary, check and maintain record of specific gravity by Hygrometer. 13) Checking battery terminals & battery charger.14) Checking alternator Carbon brushes & its tension & adjusting as per requirement including replacement or carbon brushes. 15) Supplying sufficient diesel for maintenance activities shall be the contractor's responsibility 2 Nos of DG set Note: - i) AMC charges shall be applicable only when the DG is in working condition. If the DG is not in working condition, the contractor shall inform the Engineer-in-Charge accordingly. Any repair work required shall be approved separately by MSPHC. ii) The Annual Maintenance Contract (AMC) for the Elevator should be awarded to the original manufacturer. |
| 138 | FIRE FIGHTING |
| 139 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 140 | Providing 1 Year servicing and refilling of Existing CO2 type portable fire extinguishers of 4.5 Kg including the following works and maintenance activities as per IS: 2190 and standard fire safety guidelines:Every six month inspection and maintenance of each extinguisher, including visual checking of physical condition, pressure gauge indication, safety pin, hose, nozzle, and label condition, Cleaning and checking of extinguisher body, discharge pipe, and nozzle for blockages, corrosion, or damage Verification of pressure level, Replacement of defective parts such as pressure gauge, safety clip, discharge hose, or nozzle with new ISI marked components where necessary. Once in year Hydrolic testing, repainting and labeling of the extinguisher body with approved paint and stickers showing type, capacity, and date of refilling and refilling with with presurized carbon dioxide (Co2) gas of required quantity and quality and submission of Hydrolic test certificate & Demonstration and minor training to the concerned staff on proper usage and first-level inspection.All work to be completed as per manufacturer's recommendations, safety norms and to the satisfaction of the Engineer-in-Charge |
| 141 | Providing 1 Year servicing and refilling of Existing ABC type portable fire extinguishers of 6 Kg including the following works and maintenance activities as per IS: 2190 and standard fire safety guidelines:Every six month inspection and maintenance of each extinguisher, including visual checking of physical condition, pressure gauge indication, safety pin, hose, nozzle, and label condition, Cleaning and checking of extinguisher body, discharge pipe, and nozzle for blockages, corrosion, or damage Verification of pressure level, Replacement of defective parts such as pressure gauge, safety clip, discharge hose, or nozzle with new ISI marked components where necessary. Once in year Hydrolic testing, repainting and labeling of the extinguisher body with approved paint and stickers showing type, capacity, and date of refilling and refilling with fresh approved ABC dry chemical powder (mono ammonium phosphate-based) MAP 90 of required quantity and quality and submission of Hydrolic test certificate & Demonstration and minor training to the concerned staff on proper usage and first-level inspection.All work to be completed as per manufacturer's recommendations, safety norms and to the satisfaction of the Engineer-in-Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender