Agriculture Boards / Undertakings / PSU Closing in 9 days TDR #58557050

Tender For Electrification Of Open Plinth Areas(Cap) And Depot Premises By Replacment Of Exisiting Cables,Lights And Old Feeder Panels, Along With Repair Of High Mast Towers At Fsd Taraori U/D Do Karnal.

Issued by Boards / Undertakings / PSU · Karnal, Haryana
Tender Value
22.34 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
9 days left
EMD
45000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Karnal → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrification Of Open Plinth Areas(Cap) And Depot Premises By Replacment Of Exisiting Cables,Lights And Old Feeder Panels, Along With Repair Of High Mast Towers At Fsd Taraori U/D Do Karnal.

BOQ

Name of Work:- Electrification of Open Plinth Areas(CAP) and Depot Premises by Replacment of Exisiting Cables,Lights and Old Feeder Panels, along with Repair of High Mast Towers at FSD Taraori u/d DO Karnal.
Sl. No. Item Description
1Supplying, Installing, Testing and Commissioning of Raising & Lowering Mechanism for Existing High-Mast Lighting System, including double-drum winch, 6 mm dia. SS wire ropes, trailing cable, connectors, integral power-tool motor, manual override handle, junction box, lightning protection arrangement and all associated accessories, complete in all respects for satisfactory and safe operation of the existing high mast.
2Supplying of outdoor stand mounted feeder pillar with 36A TPN MCB incomer, single dial time switch, 45A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, incoming 35sqmm and outgoing 16 & 2.5 sq. mm terminals for 16.50 Mtr high mast
3Installation and erection of the High-Mast Feeder Pillar on Structural Steel Support Frame, including fixing of the feeder pillar on an iron-angle section frame, positioning, alignment, anchoring and grouting of the support structure in concrete, complete in all respects as directed by the Engineer-in-Charge.
4Supply, Installation, testing and commissioning of pipe-mounted, single-dome aviation obstruction warning light with LED lamp, having die-cast aluminium alloy housing and polycarbonate dome, rated for 230 V AC, with IP65 degree of protection, complete with all necessary accessories, suitable for aviation obstruction marking, as required.
5Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
6Supplying and laying 25 mm X 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode,including connection/terminating with G.I. nut,bolt,spring,washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
7Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. (DSR 2025 Item no.5.16)
8LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and<135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 250 W
9250 W
10Supply and fixing of cubical type weather,water & dust proof feeder panel for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 1.50 to 1.8 Sq. Mtr. (Approx.) fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade and shall be dust proof, verm proof, removable cobers, gasketed all around multy tire formation and seperate removable gland plate for each verticle section mounting of MS angle base frame, with 200 A Four Pole MCCB-01 Nos., 125 Amp 4-Pole MCCB -03 Nos, 63 A FP MCB-02 nos., 32 A DP MCB - 03 no.& 4 strip Al. busbar of capacity 200 A = one set 4. Voltmeter & selectors switches, Ammeter, CT’S (with HRC fuse)= 1 Set. Further erection of Feeder Pillar on Structural Steel Support Frame, including fixing of the feeder pillar on an iron-angle section frame, positioning, alignment, anchoring and grouting of the support structure in concrete, complete in all respects as directed by the Engineer-in-Charge
11Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required
12100 A,30KA,FPMCCB
13Supply, installation, testing and commissioning of 40 W LED Well Glass Luminaire, environment-friendly, energy-efficient, IP66 protected, corrosion-resistant, pressure die-cast aluminium housing, suitable for vertical/horizontal surface mounting on truss, wall or pole with suitable clamps, nuts and bolts, complete with high-power LED light source having minimum luminaire efficacy of 125 lm/W, consuming less energy while maintaining high illumination levels. The luminaire shall have a long service life and shall conform to the relevant BIS Standards/Codes. The item shall include all accessories, wiring connections, testing and commissioning complete at site as required, with a minimum 2-year comprehensive onsite warranty for the complete luminaire including LED driver and LED module from the date of commissioning.
14Supplying and fixing of SMC loop in loop out boxes with PVC Box of size 8\\"x6\\"x4\\" with 2/4 way strip connector i/c testing as reqd.for S/L and F/L with up to date ammendment as required.(Confirming to relevant BIS Standards/Codes)
15LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) . Supplying, installation, Testing & Commissioningof Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), 150 W
16150 W
17Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
18Supplying of 7.00 to 7.50 Mtr. long swaged steel tubular pole, approx. 90 Kg, comprising 114.3 mm dia × 5.40 mm thick × 4.00 Mtr. bottom, 88.9 mm dia × 4.85 mm thick × 1.50 Mtr. middle and 76.1 mm dia × 3.25 mm thick × 1.50 Mtr. top sections, with base plate, conforming to IS:2713:1980 and latest amendments, including bituminous painting internally and externally below ground level, red oxide primer and silver finish paint above ground.
19Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. :Group C
20Supplying of XLPE insulated and PVC tape innersheated aluminium aluminium conductor armoured cable of 1.1 KV grade of following sizes confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
21CABLE SIZE 2 X 10 SQ.MM
22CABLE SIZE 4 X 16 SQ.MM
23Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (Upto 35 sqmm )
24Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(Upto 35 sqmm )
25Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
262 X 10 sq. mm (19mm)
274 X 16 sq. mm (28mm)
28Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
29Supplying and fixing of following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
304 way (4 + 12), Double door
31Supplying and fixing of following rating, TPN, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles (Conforms to IS/IEC 60898 or IEC 60947 - 2 )(Confirming to relevant BIS Standards/Codes)
3263 Amp
33Supplying and fixing of 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections testing, commissioning etc. as required.
34Single pole and neutral
35Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required
36Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.60947 - 2 )(Confirming to relevant BIS Standards/Codes)
3712 Module (200mmX150mm)
38Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (DSR EM 2025-1.24 )
395/6 A switch
403 pin 5/6 A socket outlet
41Supplying of XLPE insulated and PVC tape innersheated solid copper conductor unarmoured cable of following sizes confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
423C x 1.5 sqmm
43Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finishpaint etc. as required.
44Supply, Installation,Testing & commissioning of LED pylon signage(both side LED lightening) of specified size fabricated out of 1\\"x1\\" MS pipe box, 3mm thick computerised router cut ACP Sheet and 3mm thick acrylic sheet pasted from back of the cut out letters, logo and complete content with LED and waterproof & dustproof power supplies for backlit purpose. Powder coated Aluminum sheet shall be fixed from the required side of the entire board to make box section, Light Source: LED modules , Lumens: 120–150 lumens per watt for standard module, Life: min. 60,000 burning hours, Power consumption - ~1.5 Watt per module(approx), input:230V, output: 12V DC, 1ft = ~ 3 Module, Working Temperature: -10 ℃ to 55 ℃, making it visible even in low light conditions, Waterproof LED modules, energy-efficient IP68 rated with colour temperature with IP68 grade power supply, Backlight with transparent acrylic backs etc. Frame will be held on min. 2 nos. MS angle of required length of min. size 2\\"X2\\" required suitable foundation to support pylon board with \\" Food Corporation of India, FSD Taraori, DO Karnal FCI Logo, address etc. written in Hindi and English language on both sides of board .Design as per the latest FCI norms to be provided by FCI and as per the direction of Engineer-in-charge .
45LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
46100W Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58557050
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 22.34 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Electrification Of Open Plinth Areas(Cap) And Depot Premises By Replacment Of Exisiting Cables,Lights And Old Feeder Panels, Along With Repair Of High Mast Towers At Fsd Taraori U/D Do Karnal.
Basic Detail
Tender No EE/07/2026-27
Bidding Type Tender
Location
City Karnal
State Haryana
Key Dates
Publish Date 16 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 22.34 Lakhs
Tender Fee Ref. Documents
EMD 45000
Exemption Not Available
Document List
499a9c80-82df-4b3a-aef3-266e0ac57467.html
BOQ_981961.xls
TaraoriMTF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

499a9c80-82df-4b3a-aef3-266e0ac57467.html

xls

BOQ_981961.xls

pdf

TaraoriMTF.pdf

pdf

Tendernotice_1.pdf

Disclaimer