Tender for Repair/Maint Of Lt Panel, Lt Overhead Line, Transformer And Other Connected Itmes At Palchan Under Age (I) Rnd Manali.

BOQ

Name of Work:- REPAIR/MAINT OF LT PANEL, LT OVERHEAD LINE, TRANSFORMER AND OTHER CONNECTED ITMES AT PALCHAN UNDER AGE (I) RnD MANALI.
Sl. No. Item Description
1Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 10 Sqmm x 2 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
2Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 16 Sqmm x 2 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
3Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 25 Sqmm x 4 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
4Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 35 Sqmm x 3.5 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
5Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 50 Sqmm x 3.5 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
6Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 70 Sqmm x 3.5 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
7Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of size 95 Sqmm x 3.5 Core after taking down of existing, complete all as specified and directed by Engr-in-charge.
8M&L for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required above 35 sqmm upto 95 sqmm, complete all as specified and directed by Engr-in-charge.
9Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sqmm, complete all as specified and directed by Engr-in-charge.
10Taking down of any type of LT/ Bus bar panel of any size and any type, complete all as specified and directed by Engr-in-charge.
11Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 600 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.00 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:- ( LOCATION :- ) Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Tricolite.
12BUS BAR CHAMBER :- (a) 600 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 400 Amps 36 KA 4 Pole with Adjustable thermal & fixed magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:- L&T/ Siemens / Legrand/ Havells/HPL.INSTRUMENT FEEDER :- (a) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (b) Digital Amp Meter, 96X96mm, flush type rated 0-400 A, with Amp meter Selector switch- 01 Set. (c) C.T's 400/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(d) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(e) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
13OUTGOING SUPPLY :- (i) MCCB 325 Amps 36 KA 4 Pole with Adjustable thermal & fixed magnetic release 415 volts , 50Hz,=02 Nos., Make of MCCB:- L&T/ Siemens / Legrand/ Havells/HPL. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011)2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V5. ISO 9001 CERTIFIED
14\\"Maintenance/servicing of existing transformer from 63 KVA including follwing work/operations all as directed and to the entre satisfaction of Engr-in-Charge :-(a) Opening of top plate after disconnection from HT/LT side. (b) Decaning of old transformer oil & keeping it for reuse after centrifusing to required dielectric strength as per IS schedules.(c) Checking maintenance of all internal parts as HT/LT coils of all places, HT bushing, internal electrical connections, tap changing gear box.(d) Iternal cleaning of tank, cooling tubes free from sludge deposition.(e) Tightening of each bolts/nuts.(f) Refilling of oil after repairs / maintenance work.(g) Change of cork Gasket of top cover.(h) Tightening of core.(j) Assembly of complete transformer.(k) Taking meggar value by applying not less than 5000 Volts meggar on HT side and not more than LT side from 500 Volts meggar & recording results.(m) Change of silica jel and glass of oil level indicator of cover both.(n) M & L for painting to transformer of any capcacity from outside with one coat of synthetic enamel paint gray colour after cleaning the transformer.\\".Note :- Spares/oil shall be paid under relevent items
15\\"Maintenance/servicing of existing transformer from 250 KVA including follwing work/operations all as directed and to the entre satisfaction of Engr-in-Charge :-(a) Opening of top plate after disconnection from HT/LT side. (b) Decaning of old transformer oil & keeping it for reuse after centrifusing to required dielectric strength as per IS schedules.(c) Checking maintenance of all internal parts as HT/LT coils of all places, HT bushing, internal electrical connections, tap changing gear box.(d) Iternal cleaning of tank, cooling tubes free from sludge deposition.(e) Tightening of each bolts/nuts.(f) Refilling of oil after repairs / maintenance work.(g) Change of cork Gasket of top cover.(h) Tightening of core.(j) Assembly of complete transformer.(k) Taking meggar value by applying not less than 5000 Volts meggar on HT side and not more than LT side from 500 Volts meggar & recording results.(m) Change of silica jel and glass of oil level indicator of cover both.(n) M & L for painting to transformer of any capcacity from outside with one coat of synthetic enamel paint gray colour after cleaning the transformer.\\".Note :- Spares/oil shall be paid under relevent items
16M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer installed at various site on plinth 2/4 pole structure of any capacity and topping up deficient transformer oil including testing of samples before and after dehydration and filteration, complete all as specified and directed by Engr-in-charge.Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 13 here-in -after as supply only.
17Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed
18Supplying and fixing in repairs, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity 63/250 KVA and re-connecting electrically and mechanically, testing, complete all as specified and directed by Engr-in-charge.Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and provision of pad type bus bar almuminium of approppiate size /capacities of transformers with nut bolt & washers.
19Supplying and fixing in repairs, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity 63/250 KVA and connecting electrically and mechanically, testing, complete all as specified and directed by Engr-in-charge.Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and connections.
20Supplying and fixing in repairs, all unserviceable gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity 63/250 KVA and re-connecting electrically and mechanically, testing, complete all as specified and directed by Engr-in-charge.Note. The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers etc.
21Supplying and fixing in repairs, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 63/250 KVA, complete all as specified and directed by Engr-in-charge.
22M&L for cross arms, bracings, supports, channel,clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including taking out existing supports of wooden pieces for holding overhead conductor, complete all as specified and directed by Engr-in-charge.
23Dismantling burnt / defective Gang Operated Switch keeping away from site , Supply & install 11 KV 3 Phase Gang operated air break switch with drop out fuses set ( consisting 12 Nos Post Insulator ) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, complete all as specified and directed by Engr-in-charge.
24S&F in repairs of lightening arrestor explusion type complete with all fittings, transmission class, discharge capacity 65kA and suitable for working voltage 11000 volts, complete all as specified and directed by Engr-in-charge.
25S&F in repairs of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with & including M.S. clamps, bolts and nuts of approved size, for LT of 20x15cm size, complete all asspecified and directed by Engr-in-charge.
26S&F in repairs of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with & including M.S. clamps, bolts and nuts of approved size, for HT of 25x20cm size, complete all asspecified and directed by Engr-in-charge.
27Cleaning, preparing and painting with one coat of super enamalled aluminium paint over two coats of red oxide primer to cross arms, MS channels, angle iron, frame work, on pre-stressed HT concrete 2 pole/4 pole structure, complete all as directed by Engineer-in-Charge.
28M&L for servicing of servo voltage stablizer by Collecting the unserviceable three phase voltage stabilizer of capacity 60 KVA of any make/type on site or taking to local workshop for repair and open the stabilizer, taking out unserviceable spare part including replacement of the same with new one, replacement of requisite internal wiring and re-assembling the stabilizer, testing complete and re-locating the same at its original position including making all electrical connection, complete all as specified and directed by Engr-in-charge.Note:- Unserviceable spare parts shall be measured and paid separately as \\"supply only\\".
29Supply only in replacement of relay for voltage stabilizer suitable for60 KVA capacity, complete all as specified and directed by Engr-in-charge.
30Supply only in replacement of printed circuit board (PCB) consisting diode, resistance, capacitor complete suitable for 60 KVA voltage stabilizer, complete all as specified and directed by Engr-in-charge.
31Supply only in replacement of copper wound main transformer suitable for 60 KVA voltage stabilizer, complete all as specified and directed by Engr-in-charge.
32Supply only in replacement of copper wound dimmer transformer suitable for 60 KVA voltage stabilizer, complete all as specified and directed by Engr-in-charge.
33S & F loose filling with stone aggregate of gauge 40mm to 80 mm deposited spread and levelled in layers not exeeding 15 cm to a true surface of broken stones for transformer area and pole structrure area of an area of 15 Sqmin area of 250KVA 2/4 Pole structure, complete all as specified and directed by Engr-in-charge.
34Isolate/de-energize the supply to the LT Panel Board of capacity ranging from 100 Amps to 400 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear,MCCB, metering etc and re-fixing the same/New in place after repairs including testing and commissioning of the panel board comprising of the following:-a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower .b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required.Note :- Spares will be measured and paid under relevant items of schedule..
35Supply only selector switch suitable for 415volts as per existing model/ capacity.
36Supply only Voltmeter of range 0 to 500 Volts as per existing model/ capacity.Make :- L&T/Schneider/Siemens/AE/C&S
37Supply only Ammeter of range 0 to 500 Volts as per existing model/ capacity
38Supply only Indicator lamp neon/ LED type, RBY as per existing model/ capacity .
39Supply only CT coil ratio 200/5 as per existing model/ capacity .
40Supply only in repair of 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn complete all as specified and as directed. (Make:- Polycab/Havells/Finolex/Gloster/Grandlay)
41Supply and fixing in repair and replacement of mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and as directed.
42Material and Labour for preparation of surface by scrapping existing painted inside and out side surfaces of LT Panel board /Feeder piller of size not more than 1.5m x 0.75m x 1.2m and applying one coat of synthetic enamel paint (1st grade quality) and one coat of heat resistant paint of approved quality and colour, complete all as specified and directed by Engr-in-charge.
43Supply & fix in repair MCCB 400 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engr-in-charge.
44Supply & fix in repair MCCB 250 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engr-in-charge.
45Supply & fix in repair MCCB 200 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 25 KA with adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engr-in-charge.
46Supply & fix in repair MCCB 160 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 25 KA with adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engr-in-charge.
47Supply & fix in repair MCCB 125 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 25 KA with adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engr-in-charge.
48Supply & fix in repair MCCB 100 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 16 KA with adjustable thermal and adjustable magnetic setting , complete all as specified and directed by Engr-in-charge.
49Supply & fix in repair MCCB 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 16 KA with adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engr-in-charge.
50Providing, checking, testing and carrying out load balancing of existing electrical panels and distribution boards by suitably redistributing single-phase loads among the three phases to achieve approximately balanced phase loading. The work shall include measurement of existing phase-wise current/load, identification of overloaded or under-loaded phases, shifting/rearranging outgoing circuits as required, tightening of all connections, proper ferruling/identification, and testing after completion. The work shall be carried out without disturbing the normal operation of the electrical installation, as far as practicable, and in accordance with applicable electrical safety standards , complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58556589
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.10 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Lt Panel, Lt Overhead Line, Transformer And Other Connected Itmes At Palchan Under Age (I) Rnd Manali.
Basic Detail
Tender No AGE(I)/MNL/T-02/2026-27
Bidding Type Tender
Location
City Kullu
State Himachal Pradesh
Key Dates
Publish Date 16 Nov 2026
Submission Date 07 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value 14.10 Lakhs
Tender Fee 500
EMD 28200
Exemption Available
Document List
BOQ_896397.xls
d3a671e8-5f3d-479e-8ff9-3058c8fb46e5.html
TenderDocumentsT022627EM.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_896397.xls

html

d3a671e8-5f3d-479e-8ff9-3058c8fb46e5.html

pdf

TenderDocumentsT022627EM.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender