Project Description

Tender for Repair / Replacement Of Refg, Desert Cooler, Water Coolers, Ac, Deep Freezer, Allied Items, Electric Wiring With Fitting And Fixtures, Sub Main Wiring Dbs & Service Connection With Earthing Central Institute, Stn Pool Area & Offrs Mess At Mil Stn Dhrangadhra

BOQ

Name of Work:- REPAIR / REPLACEMENT OF REFG, DESERT COOLER, WATER COOLERS, AC, DEEP FREEZER, ALLIED ITEMS, ELECTRIC WIRING WITH FITTING AND FIXTURES, SUB MAIN WIRING DBs & SERVICE CONNECTION WITH EARTHING CENTRAL INSTITUTE, STN POOL AREA & OFFRS MESS AT MIL STN DHRANGADHRA
Sl. No. Item Description
1Disconnection and removing the U/S Desert Cooler of capacity 120/80 Ltrs from the existing position for finding out the defects and to be replace the unserviceable spare parts such as Fan Motor, Water Pump, Khas-Khas Pads etc and refixing the desert cooler to its original position complete all as specified and as directed. Note:- (i) Contractor shall collect the Desert Cooler for repair from Store Yard/site of AGE E/M and fix the repaired desert cooler the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush, capacitor fan blade pump and grass pads shall be measured and paid separately under respective item of this schedule as \\"Supply only\\".
2S&F, in repair, fan motor copper (ISI Marked), 1/6 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed.
3S&F, in repair, stainless steel fan motor blade, 230 volt single phase suitable for existing desert coolers with fixing clamps, nuts, bolts, washers etc. complete all as specified and directed.
4S&F, in repairs, water lifting submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
5S&F in repair, PVC distributer, Elbow and PVC pipe and Supply and fix new water distributer 3 way consisting 3 Nos of PVC elbow and 1/2 \\" heavy duty PVC Pipe of length upto 2 mtrs suitable for existing desert coolers.
6S&F, in repair, grass pads and wood wool pads, superior quality, of same size and and thickness set of 3 for desert cooler to the satisfaction of Engineer-in-Charge.
7S&F in replacement brackets for fan motors of desert cooler made out of flat iron of size 25mmX3mm, 300mm long, bent to shape and including drilling of holes (set of four) etc complete all as specified and as directed by Engineer-in-charge.
8S&F in replacement selector switch suitable and to match the existing desert cooler to match the existing suas per sample complete all as specied and directed.
9Supply and fixing of steel body evaporative Duct Type desert cooler with fan motor (copper winding) (ISI marked to IS 996 latest), fan blade of 380mm sweep of aluminum material, 1400 RMP for 2000 cum/hr nominal air capacity, 3 Speed Control, wood wool filter pads of thickness size is 15mm or above with non-corrosive wire guard for filter pads, float valve at the inlet, submersible pump, the material of filter panel, grill, top of the cooler body is made of galvanized steel sheet of thickness not less than 0.8mm and sump/water tank of minimum 80 liters capacity including sheet thickness not less than 1.00mm with zinc coating not less than 100 gms/sq.meter and all internal surface of steel body painted with water-resistant paint to IS 9862 latest and brass/ss material drain 3 pin molded plug top of 5/6 amps plug ISI marked, 230 Volts, 50Hz, connecting cable and commissioning complete all as specified and directed.
10S&F, in repair, PVC flexible pipe 12mm dia suitable for submersible pump of desert cooler complete all as specified and directed.
11S&F, in repair, PVC insulated, sheathed cable 3 core, 1.5 Sqmm, multistandard copper conductors minimum length 2 mtr for Desert Cooler, water coolers/ refrigerators as main cord with 5A, 3 pin top complete all as specified and directed.
12Taking down and Refixing up carefully 1.5 ton window or 1.5/2 ton split type AC after checking of electric wiring and parts , cleaning of unit, lubrication of motor, capillary, filter & servicing at existing position/location complete all as specified and directed. Note:- (i) Compressor, capacitor, starting relay, overload protection shall be separetely measured and paid. (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
13S&F, in repair, Indoor unit AC Swing motor blades (replaced with original company of same make as per existing), suitable for working on single phase, 50 HZ AC , 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
14S&F, in repair, Indoor unit AC blower fan motor (replaced with original company of same make as per existing), suitable for working on single phase, 50 Hz AC supply, 1.5/2 Ton type split AC with electric connection, testing complete all as specified and directed.
15S&F, in repair, Indoor unit AC blower fan bush (replaced with original company of same make as per existing), suitable for working on single phase, 50 Hz AC supply in split type AC with electric connection, testing complete all as specified and directed.
16S&F, in repair, Indoor unit AC Cooling condenser (replaced with original/as per existing), suitable for working on single phase, 50 Hz AC supply, 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
17S&F, in repair, Indoor unit AC Display unit (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
18S&F, in repair, Remote with PCB Circuit of 1.5/2 Ton capacity split ACs (replaced with as per existing), suitable for working on single phase, 50 HZ AC supply in split type AC with electric connection, testing complete all as specified and directed.
19S&F, in repair, Outdoor unit AC Fan motor blade of suitable size (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
20S&F, in repair, air filter in suitable (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
21S&F, in repair, Outdoor unit AC copper coils of suitable size (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply , 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
22S&F, in repair, Outdoor unit AC insulation tubing/cover as per existing tubing tickness of 8 feet lenght For 1/4\\" & 1/2\\" size of copper coils(replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
23S&F, in repair, Outdoor unit condenser fan motor of suitable size (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
24S&F, in repair, Outdoor unit AC heat condenser coil of suitable size (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
25S&F, in repair, sealed unit compressor (replaced with original company, new compressor of same make as per existing) suitable for Operation on single phase, 50 HZ AC supply for 1.5 ton split type AC including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed.
26S&F, in repair, Outdoor unit AC Compressor capacitor of suitable capacity (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2ton split type AC with electric connection, testing complete all as specified and directed.
27M&L, in repair, Outdoor unit AC Gas valves of suitable size (replaced with original company of same make/as per existing),For 1.5/2 Ton split type AC with all conecting accessories, testing complete all as specified and directed.
28S&F, in repair, Outdoor unit AC power relay contactors of suitable capacity (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
29M&L for refrigerent charging with R 22/R 134/R 410 for window AC of capacity 1.5 Ton and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
30M&L for refrigerent charging with R 22/R 134/R 410 for split type AC of capacity 1.5 & 2 Ton and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
31S&F, in repair, sealed unit compressor (replaced with original company, new compressor of same make as per existing) suitable for Operation on single phase, 50 HZ AC supply for 2 ton split type AC including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed.
32S&F,in repair, Running capacitor of 36 to 45 MFD capacity for 1.5/2 ton split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
33S&F,in repair, Running capacitor of 60 MFD capacity for window/split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
34S&F, in repair, Heavy duty ODU (outdoor unit) Stand/installation bracket kit with brackets, fasteners, nuts and washer for 1.5/2 ton split type AC complete all as specified and directed.
35Material and labour for Internal wiring for split unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
36S&F, in replacement, outdoor unit sealed complete set for split type AC of 1.5 TR, BEE 5 star (replaced with original company of same make as per existing), suitable for working on single phase, 50 Hz AC supply with electric connection, testing complete all as specified and directed.
37M&L, in repair, Sensors for all model type ACs, including making necessary electric connections complete all as specified and directed.
38S&F, in replacement, indoor unit sealed complete set for split type AC of 1.5 TR, BEE 5 star (replaced with original company of same make as per existing), suitable for working on single phase, 50 Hz AC supply with electric connection, testing complete all as specified and directed.
39S&F, in repair, overload contactor for split type AC of 1.5/2 Ton capacity complete all as specified and directed.
40M&L, in repair, copper piping of 1/2\\" & 1/4\\" size, wiring between Indoor & Outdoor for 1.5/2 ton split type AC including all necessary connecting accesssories complete all as specified and directed.
41S&F, in repair, indoor unit DC motor (replaced with original company of same make/as per existing), of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity inverter type Split ACs with electric connection, testing complete all as specified and directed.
42S&F, in repair, DC indoor circuit (replaced with original company of same make/as per existing), of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity inverter type Split ACs with electric connection, testing complete all as specified and directed.
43S&F, in repair, inverter type outdoor unit circuit (replaced with original company of same make/as per existing), of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity inverter type Split ACs with electric connection, testing complete all as specified and directed.
44S&F, in repair, inverter outdoor unit DC compressor (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity Inverter Type Split ACs with electric connection, testing complete all as specified and directed.
45S&F, in repair, inverter outdoor unit sensor (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity Inverter Type Split ACs with electric connection, testing complete all as specified and directed.
46Disconnection and Removing the Cable connection and Copper pipe alongwith all connection items carefully from the existing indoor and out door units and Pump down the refrigerant from out door unit of tonnage 1.5/2 ton including stablizer from the existing position and shifting the AC unit at new place and refixing the out door and indoor units with necessary copper tubing including topping up of gas and connecting stablizer etc for its proper functioning all as direcred and specified by Engineer-in-charge.
47Disconnection and Removing the defective/damaged Industrial Plug & Socket Board and supply & fix Industrial Plug & Socket controlled 15/16Amp Single Pole ISI Marked in and including sheet metal enclosure suitable for 1.5/2 Ton capacity complete all as specied and directed.
48S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
49S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
50S&F, in repair, Evaporator of 165/180L Capacity (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 & 1/6 HP (180 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
51S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
52S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
53M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
54S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 320 Ltr complete all as specified and directed.
55Supply fixing incl testing in repairs of Refrigerator double door single phase electric driven of 410 ltrs BEE 3 star capacity complete all as specified and as directed by Engineer-in-Charge.
56S&F, in repair, Deep freezer condenser (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
57S&F, in repair, Deep freezer condenser fan motor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection, electric connections and testing complete all as specified and directed.
58S&F, in repair, Deep freezer cooling fan of same size (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection, electric connections and testing complete all as specified and directed.
59M&L for refrigerent charging with R-134A/R-600a for Deep Freezer of capacity 200 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
60M&L for refrigerent charging with R134a, R-600a for Refrigerator of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
61S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
62M&L, in repair, starting relay of water coolers 40/80 Ltr capacity including making necessary electric connections complete all as specified and directed.
63S&F, in repair, overload protector of water cooler and deep frezzer up to 120Ltr complete all as specified and directed.
64M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
65M&L, in repair, Thermostate suitable for water cooler upto to 120 ltrs capacity including making necessary electric connections complete all as specified and directed.
66M&L, in repair, Thermostate suitable for Refrigerator up to 320 ltrs capacity including making necessary electric connections complete all as specified and directed.
67Opening to refrigerator frezzer of capacity 180 to 320ltr Refixing the same after flushing out and removal of blockge brazing replacement of liquid line, filter and recharging to refrigerator with R134a, R-600a gas to obtain the desired cooling complete all as specified and as directed by engineer-in-charge
68Disconnecting and removing the u/s and Supply fixing incl testing in repairs of Pure-R Refrigerator single phase electric driven of (500 watt) water dispenser complete all as specified and as directed by Engineer-in-Charge.
69Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler Deep frezzer with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler/Deep frezzer complete.Note :- The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit.
70Opening to refrigerator PCB Circuit plate of capacity 180 to 308ltr and S&F PCB Circuit plate fixing the same size (as per site require) Complete all as specified and as directed by engineer-in-charge
71S& F in repair, for 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler Complete all as specified and as directed by Engineer-in-Charge.
72S&F Bulb Unit of same size and capacity suitable for 165 to 310 ltrs refrigerator complete all as specied and directed.
73S&F in repairs Relay box type for any size and capacity suitable for refrigerator complete all as specied and directed.
74S&F, in repair, Running capacitor, 230 Volts, SP, 4.0 MFD complete all as specified and directed.
75S&F, in repair, Running capacitor, 230 Volts, SP, 6.3 MFD complete all as specified and directed.
76Taking down carefully dismantling voltage stabilizer of capacity 03 KVA to 5 KVA, single phase 240 volt AC of any make and any size opening up for inspection necessary repair and replacement of worn out/defective spare parts, rewinding of main transformer with supper enameted copper wire of existing gauge and weight reassembling, connecting up, testing etc complete all as directed by Engineer-in-Charge (Necessary spare parts required for replacement shall be measured and paid for separately as supply only) and fixing is included under this item.
77S&F relay condenser and electronic circuit suitable for voltage stabilizer of capacity 3 KVA to 5 KVA of existing make and size complete all as specified and as directed by Engineer-in-charge.
78Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, bell, regulators sockets etc, and removing from site and making good distribut surfaces of walls, floors etc all as directed.
79Taking down existing unserviceable MCB DB/TPN/SPN/SP along with MCBs complete by disconnecting all as directed.
80Taking down existing unserviceable T/light fitting & box type fitting complete all as specied and directed.
81Taking down existing unserviceable sub main wiring 2.5/4/6 Sqmm aluminium/copper cable all as directed.
82M&L for point wiring with PVC insulated, sheathed FRLS cable 1100 Volts grade, ISI marked multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) for phase, neutral & earth, single core drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :- Note :- (i) wiring shall be done by using proper colour coding.
83(a) One light point controlled by one way 5 Amps switch
84(b) One ceiling fan/exhaust fan point controlled by one, one way 5 Amps switch
85(c) One 3 pin socket outlet 5 Amps on independent board
86(d) One 3 pin socket outlet 5 Amps on same board
87(e) One Bell point controled by one bell push on same board with other switches or on independent board.
88(f) One light point controlled by two, 2- way switches.
89All as per srl item No. 82 here-in-before but for 6/16 Amp independent socket outlet using 2.5 sqmm single core wire (for phase, nuetral and earth) complete all as specified. Note :- (i) wiring shall be done by using proper colour coding. Please Enable Macros to View BoQ information
90All as per srl item No. 82 here-in-before but for 6/16 Amp independent socket outlet using 2.5 sqmm single core wire (for phase, nuetral and earth) complete all as specified. Note :- (i) wiring shall be done by using proper colour coding. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58556571
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement Of Refg, Desert Cooler, Water Coolers, Ac, Deep Freezer, Allied Items, Electric Wiring With Fitting And Fixtures, Sub Main Wiring Dbs & Service Connection With Earthing Central Institute, Stn Pool Area & Offrs Mess At Mil Stn Dhrangadhra
Basic Detail
Tender No GE(A)/GNR/TOKEN/29 of 2026-27
Bidding Type Tender
Location
City Surendranagar
State Gujarat
Key Dates
Publish Date 16 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 38000
Exemption Available
Document List
16b770f8-04a3-43ae-9915-be2cae072e1d.html
BOQ_896399.xls
TenderDocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.