Project Description

Tender for Installation Of Panel Board At Spb (Kar) Premises To Domestic And Industrial Power Supply And Special Repairs For Replacement Of Low Pressure Trade Waste Pumps (Lptw) In Service Tunnel At Various Locations At Nsry (Kar)

BOQ

Name of Work:- INSTALLATION OF PANEL BOARD AT SPB (KAR) PREMISES TO DOMESTIC AND INDUSTRIAL POWER SUPPLY AND SPECIAL REPAIRS FOR REPLACEMENT OF LOW PRESSURE TRADE WASTE PUMPS (LPTW) IN SERVICE TUNNEL AT VARIOUS LOCATIONS AT NSRY (KAR)
Sl. No. Item Description
1M&L for taking down (lifting/lowering) low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr including column pipe and cable after disconnecting, dismantling, repairing, transporting to workshop (to and fro) from the site and reassembling, testing and reinstalling at site complete all as specified and directed by Engr-in-Charge.
2M&L for dismantling of low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr cast iron body, cutting and removal of existing burnt winding, cleaning of stator slots, and rewinding with super enamelled copper wire of suitable size and rating, having Class F/H insulation. Reassembling motor with proper alignment, and testing for insulation resistance (megger test), continuity, no-load complete all as specified and directed by Engr-in-Charge.
3S&F high quality insulation materials including sleeves, slot liners, varnish and heat treatment suitable for Low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
4Supply & replacement of heavy duty bearings (SKF/FAG/NSK) including greasing of Low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
5S&F mechanical seal (carbon/ceramic/SiC) including leak testing of Low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
6Supply & replacement of non-clog/vortex impeller (CI/SS/GM) dynamically balanced for Low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
7Supply and replacement of stainless steel pump shaft of suitable diameter and length suitable for Low pressure trade waste water pump capacity upto 5 HP, discharge 1.5 lit/sec, head 5mtr, RPM 2900, manufactured from approved quality stainless steel, accurately machined, including keyway cutting, threading, polishing and fitting in position, complete with proper alignment, coupling with motor and testing, complete in all respects of make -M/s MBH Pumps, Model No: SSF 10/22.
8Supply & replacement of pump casing/volute with proper sealing for Low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
9Supply and laying of 3 core 4 sqmm flat type submersible cable, including taking down with multistrand copper conductors, PVC insulated and overall PVC sheathed, suitable for 1100V grade, conforming to IS 694 / IS 1554. The cable shall be resistant to moisture, oil and abrasion, suitable for submersible pump application. The work includes laying of cable through conduit/along wall/shaft, proper dressing, fixing with clamps/saddles, making necessary connections at both ends, including glanding, crimping with copper lugs, insulation with tape/sleeves, and testing for continuity and insulation resistance, complete all as specified and directed by Engr-in-Charge.
10Supply and laying of 3 core 10sqmm flat type submersible cable, including taking down with multistrand copper conductors, PVC insulated and overall PVC sheathed, suitable for 1100V grade, conforming to IS 694 / IS 1554. The cable shall be resistant to moisture, oil and abrasion, suitable for submersible pump application. The work includes laying of cable through conduit/along wall/shaft, proper dressing, fixing with clamps/saddles, making necessary connections at both ends, including glanding, crimping with copper lugs, insulation with tape/sleeves, and testing for continuity and insulation resistance, complete all as specified and directed by Engr-in-Charge.
11Providing and making waterproof heat shrink type cable joint for submersible cable, using approved heat shrinkable jointing kit, suitable for 1100 volts grade cable, complete with connectors, sleeves, insulating and sealing components, ensuring complete protection against moisture ingress, complete in all respects.
12M&L for taking out (lifting/lowering) drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, cast iron body, from bottom of tunnel sump tank located at pier-1, depth upto 5 mtr including column pipe and cable after disconnecting, dismantling, repairing, transporting to workshop(to and fro) from the site and reassembling, testing and reinstalling at site complete all as specified and directed by Engr-in-Charge.
13M&L for dismantling of drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, cast iron body, , cutting and removal of existing burnt winding, cleaning of stator slots, and rewinding with super enamelled copper wire of suitable size and rating, having Class F/H insulation. Reassembling motor with proper alignment, and testing for insulation resistance (megger test), continuity, no-load complete all as specified and directed by Engr-in-Charge.
14S&F high quality insulation materials including sleeves, slot liners, varnish and heat treatment suitable for drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
15Supply & replacement of heavy duty bearings (SKF/FAG/NSK) including greasing of drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
16S&F mechanical seal (carbon/ceramic/SiC) including leak testing of drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
17Supply & replacement of non-clog/vortex impeller (CI/SS/GM) dynamically balanced for drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
18Supply and replacement of stainless steel pump shaft of suitable diameter and length for drainage submersible grinder pump of capacity 12.5HP/15HP, manufactured from approved quality stainless steel, accurately machined, including keyway cutting, threading, polishing and fitting in position, complete with proper alignment, coupling with motor and testing, complete in all respects.
19Supply & replacement of pump casing/volute with proper sealing for drainage submersible grinder pump of capacity 12.5HP/15HP, from tunnel (pier-1) depth upto 5 mtr complete all as specified and directed by Engr-in-Charge.
20S&F Duck foot bend shall be CI/GI construction with auto coupling arrangement suitable for existing drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, cast iron body . Guide rails shall be provided for proper alignment. System shall allow easy lowering and lifting of pump without disturbing pipe connections
21Supply and fixing of Non-Return Valve (NRV) of suitable size (generally 80mm / 100mm NB as per discharge line), CI/DI body, flanged ends, ISI marked, suitable for sewage application, including fixing in repair position with rubber gasket, nuts, bolts, complete in all respects complete all as specified and directed by Engr-in-Charge.
22Supply and fixing of sluice valve (gate valve) of suitable size (80mm / 100mm NB), CI/DI body, flanged ends, non-rising spindle type, ISI marked, conforming to relevant IS standards, including fixing in repair position with rubber gasket, nuts, bolts, complete in all respects complete all as specified and directed by Engr-in-Charge.
23Supply and fixing in repair of DOL starter suitable for Low pressure trade waste water pump capacity upto 5 HP, operating on 415V, 50Hz AC supply, comprising of:AC-3 duty contactor of suitable ratingThermal overload relay (OLR) with adjustable current settingMCB/MCCB for short circuit protectionStart (green) and Stop (red) push buttonsIndicating lamps (R, Y, B phase + ON/TRIP indication)Single phasing preventer / phase failure relayVoltmeter with selector switch (optional)Control wiring with PVC insulated copper wiresEnclosed in sheet steel enclosure (CRCA), powder coated, dust & vermin proof, IP-54 protection, suitable for wall mounting, complete with earthing terminals.The starter shall be wired, tested for insulation resistance, functional operation and commissioned, complete as directed by Engineer-in-Charge.
24Testing & commissioning including insulation, load and performance testing of Low pressure trade waste water pump capacity upto 5 HP, from tunnel (pier-1) depth upto 5 mtr cast iron body complete as specified and directed by Engr-in-Charge.
25Testing & commissioning including insulation, load and performance testing of drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter complete as specified and directed by Engr-in-Charge.
26S&F in repair lifting chain for drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter complete
27Supply and installation of level sensors (float switch type ) suitable for sump application compatible with Low pressure trade waste water pump capacity upto 5 HP, for automatic start/stop of drainage pumps.The system shall include:High level, low level and pump trip level sensorsFloat switches with heavy-duty PVC/SS bodyControl cable (multistrand copper)Fixing arrangement with clamps/supportIntegration with DOL starter panel for auto/manual operationThe system shall be suitable for dirty water/sewage conditions, resistant to corrosion and moisture.Complete wiring, testing and commissioning shall be carried out complete all as specified and directed by Engr-in-Charge.
28Supply and installation of level sensors (float switch type ) suitable for sump application compatible with drainage submersible grinder pump of capacity 12.5HP/15HP, head 59 meter, for automatic start/stop of sewage pump.The system shall include:High level, low level and pump trip level sensorsFloat switches with heavy-duty PVC/SS bodyControl cable (multistrand copper)Fixing arrangement with clamps/supportIntegration with DOL starter panel for auto/manual operationThe system shall be suitable for dirty water/sewage conditions, resistant to corrosion and moisture.Complete wiring, testing and commissioning shall be carried out complete all as specified and directed by Engr-in-Charge.
29Supply and laying of HDPE pipe (PE-100 grade) conforming to IS 4984, of suitable diameter and pressure rating (PN 6 / PN 10), for drainage application, including:Cutting and preparing existing GI/CI/HDPE pipelineProviding and fixing HDPE pipe of required lengthJointing by butt fusion / compression fittings / flange adaptorProviding HDPE to CI/GI adaptor (flange adaptor / tail piece)Providing rubber insertion gasket, nut bolts, clamps and supportsProper alignment and fixing with MS clamps with rubber liningMaking leak-proof and pressure-tight connectionTesting for leakage and proper discharge flow Complete as directed by Engineer-in-Charge.
30Supply and fixing of fully automatic star–delta starter suitable for drainage submersible grinder pump of capacity 12.5HP/15HP, operating on 415V, 3 phase, 50 Hz AC supply, comprising of:3 Nos. AC-3 duty contactors (Main, Star, Delta) of suitable ratingThermal Overload Relay (OLR) with adjustable range (approx. 28–40 Amps)Star–Delta timer (adjustable transition delay)MCB/MCCB (TPN) for short circuit protectionControl transformer (415/230V) for control circuit (if required)Push buttons: Start (Green), Stop (Red), ResetIndication lamps: R, Y, B phase, ON, TRIP, STAR, DELTAAuto/Manual selector switchSingle phasing preventer / phase failure relayElectronic hooter for fault indication (as seen in your panel)Complete internal wiring with FRLS copper wires, ferruling, cable termination, glands and lugs complete all as specified and directed by Engr-in-Charge.
31Supply and installation of 100 mm NB cope point assembly suitable for ship sewage receiving system connection with existing line after dismantling the old cope unit consisting of:Horizontal CI/MS pipe with flanged base connectionTop funnel/bell mouth inlet as per site requirementNon-return valve (NRV) – flanged typeSluice valve (gate valve) – flanged typeIntermediate flanged joints with rubber insertion gasket, HT nuts & boltsReducer/expansion piece Support arrangement / base plate fixingThe cope point shall be robust, corrosion resistant, suitable for marine sewage water application and capable of handling required discharge.Work includes:Dismantling of existing damaged cope pointFabrication and alignmentProper horizontal installationTightening of flange jointsLeak testing and commissioning Complete all as specified and directed by Engineer-in-Charge.
32Supply and installation of 100 mm NB sea water cope point assembly suitable for marine/ship connection with existing line after dismantling the old one consisting of:horizontal pipe (MS/DI/HDPE with flange) of 100 mm NBBell mouth / funnel inlet for easy hose insertionGun metal / bronze / DI valve (sluice or butterfly valve) suitable for sea waterNon-return valve (NRV) Flanged joints with rubber insertion gasket, SS/HT nuts & boltsSupport structure / base plate fixing arrangementThe cope point shall be designed for quick connection of ship flexible hose and shall withstand saline water corrosion and marine environment.The cope point shall be robust, corrosion resistant, suitable for marine sea water application and capable of handling required discharge.Work includes:Dismantling of existing damaged cope pointFabrication and alignmentProper horizontal installationTightening of flange jointsLeak testing and commissioning Complete all as specified and directed by Engineer-in-Charge.
33Supply and installation of 63mm NB fresh water cope point assembly suitable for marine/ship connection with existing line after dismantling the old one consisting of:horizontal pipe (MS with flange) of 50/100 mm NB as per site requirementBell mouth / funnel inlet for easy hose insertionGun metal / bronze / DI valve (sluice or butterfly valve) suitable for fresh waterNon-return valve (NRV) Flanged joints with rubber insertion gasket, SS/HT nuts & boltsSupport structure / base plate fixing arrangementThe cope point shall be designed for quick connection of ship flexible hose and shall withstand saline water corrosion and marine environment.The cope point shall be robust, corrosion resistant, suitable for marine sea water application and capable of handling required discharge.Work includes:Dismantling of existing damaged cope pointFabrication and alignmentProper horizontal installationTightening of flange jointsLeak testing and commissioning Complete all as specified and directed by Engineer-in-Charge.
34M&L for Earthing replacement complete with copper plate 60×60cm ×3.15mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copper strip earth strip 20x3 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq. meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing.
35SITC of Outdoor flood light/step light fixture, suitable fpr wall/step mounting complete with all accessories and connect with existing wiring, wattage : 20W -50W ( as per site requirement), input voltage:220-240v, Luminaire body: Pressure die-cast aluminium housing all as specified and directed by Engr-in-charge.
36Supply and laying or fixing or passing through pipes or in cable ducts, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductors, 3.5 core, 185 sq. mm size.Note: Earthwork, excavation, GI tubing/DWC pipes for protection, etc., shall be measured separately under the relevant items of this schedule work.
37Supply and laying or fixing or passing through pipes or in cable ducts, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductors, 3.5 core, 35 sq. mm size.Note: Earthwork, excavation, GI tubing/DWC pipes for protection, etc., shall be measured separately under the relevant items of this schedule work.
38Excavation in trenches not exceeding 1.5 m in width and not exceeding 1.5 m in depth for laying LT underground cables/GI pipes, and getting out the excavated soil in soft/loose soil, complete, all as specified and directed.
39Returning, filling in, including spreading levelling watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and directed.
40Removing excavated material/soil to a distance not exceeding 50 m and depositing it where directed, at a level not exceeding 1.5 m above the starting point, all as specified and directed.
41S&F DWC high-density polyethylene pipes of 100/95 mm dia., with all fittings, couplers and connecting accessories, conforming to IS 16098 (Part 2), for cable protection, fixed on poles/ walls/ laid under road crossings, etc., and making good the disturbed surfaces/areas, complete, all as specified and directed.
42S&F) DWC high-density polyethylene pipes of 75/63 mm dia., with all fittings, couplers and connecting accessories, conforming to IS 16025 (Part 24), for cable protection, fixed on poles/walls/ laid under road crossings, etc., and making good the disturbed surfaces/areas, complete, all as specified and directed.
43Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
44Supply and install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for three phase 4 wire including the following accessories and fitted in : - (a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 400 amp of – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs, LED indicator lamp and other connecting accessories. (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 100 amp of – 3 No (ii)MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of – 6 Nos (iii) MCB SPN 40 Amps 8 Nos all as directed by the Engr-In-Charge.
45M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58556564
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.70 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Installation Of Panel Board At Spb (Kar) Premises To Domestic And Industrial Power Supply And Special Repairs For Replacement Of Low Pressure Trade Waste Pumps (Lptw) In Service Tunnel At Various Locations At Nsry (Kar)
Basic Detail
Tender No 8580/E8
Bidding Type Tender
Location
City Uttara Kannada
State Karnataka
Key Dates
Publish Date 16 Nov 2026
Submission Date 07 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value 49.70 Lakhs
Tender Fee 500
EMD 99400
Exemption Available
Document List
30097d2f-998d-4ee2-aa1d-5528b8401281.html
BOQ_895672.xls
Tender8580.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

30097d2f-998d-4ee2-aa1d-5528b8401281.html

xls

BOQ_895672.xls

pdf

Tender8580.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender