Tender For Grey Water Management Project At Govt. Taluk Hospital Irikkur, Irikkur Gp-Grey Water Management Project At Govt. Taluk Hospital Irikkur, Irikkur Gramapanchayath In Kanur Dist.
Tender Value
29.47 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
3 days left
EMD
50000
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kannur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Grey Water Management Project At Govt. Taluk Hospital Irikkur, Irikkur Gp-Grey Water Management Project At Govt. Taluk Hospital Irikkur, Irikkur Gramapanchayath In Kanur Dist.
BOQ
| Sl. No. | Item Description |
| 1 | GREY WATER MANAGEMENT(DEWATS) |
| 2 | 2.6.1 :Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 2.7.1 :Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 4 | 2.7.2: Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting) |
| 5 | 4.1.5: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 5.2.2 :Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 5.22.6: Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 8 | 5.9.2: Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 9 | 100.55.1: Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications. |
| 10 | 100.55.2: Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification. |
| 11 | 100.55.3 :Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification. |
| 12 | OD150009/2026-2027 :Supply and spreading coal in the planted gravel filter |
| 13 | 13.7.1: 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 14 | 13.4.1: 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 15 | 13.37.1 :White washing with lime to give an even shade:New work (three or more coats) |
| 16 | 13.60.1: Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 17 | 13.62.1 :Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 18 | OD150002/2026-2027 :Supply and fixing 60cm x 60cm CI manhole cover for DEWATS |
| 19 | OD149999/2026-2027: supply and fixing cana plant for HPGF |
| 20 | OD150005/2026-2027: Supplying and erection of best quality ISI market brand &ndash open well submersible Three phase driven motor pump set working at 360 voltage (IS 14220) with bronze impeller and stainless steel shaft having minimum of 10000 lph discharge against 100 m head with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic star delta ),main switch, fuse, capacitor, ELCB ,adequate length of best quality suitable size flat submersible cable, reflux valve, sluice valve, pressure gauge, earthing materials conforming to IS 3043/2000 as amended to date ,ammeter ,voltmeter, selector switch, flickering lamps dry running preventer cum no voltage wire , conveying and erecting the motor pumpset and panel board and giving all connections earthing etc as per the KSEB/EI rules and regulations .Trial run should be given for 7 days . Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc.. complete as per the directions of engineer in charge of the work, Upto 10HP |
| 21 | OD150514/2026-2027: Design, supply installation,and commissioning ( based on site conditions and asdirected by the engineer in charge,) of PRESSURE SAND FILTER of dual media ?Anthracite and sand packed in mild steel one or more Pressure vessels with FRPlining, Butterfly valves with complete base media and shall be complete with facepiping, fittings,valves,filter media, under bed plate fitted with strainer, pressuregauges, cocks, manhole, hand hole, air vent system manufactured with goodengineering practice having minimum thickness of 4mm, having manhole with coverfor easy inspection at the top of the vessel and an opening provision for mediaremoving arrangement at vessel bottom with dummy arrangement,and painting thevessel internally and externally with two coat epoxy paint over a two coats of primer;finishing with synthetic enamel paint two coats, capable of discharging water at 3KLD with a capacity to withstand the operating head of 10 meters with best quality ISImark Butterfly valves for easy backwashing, rinsing and filtering with all necessaryhigh quality filter media with sufficient filtering capacity capable of removingTurbidity of water two times as per the water quality test report of NTU to thepermissible limit as per the BIS drinking water quality standards including all civil,mechanical and plumbing works by connecting to the existing pumping main withsuitable size of 110 mm pvc 12.5kg/cm2 and 100 mm GI medium pipes(total=900m)and specials required to deliver water to the existing reservoir using existing pump. Allauxiliary fittings including the nuts and bolts shall be made of mild steel. The vesselmay be suitably positioned anywhere along the pumping main route in order to makethe operation and maintenance easy. The total head loss due to the PSF suppliedshould not be more than 4 meters. The PSF should be designed with a capacity towithstand 1.5 times of the above given parameters of discharge & head The technicaldetails of the filter unit including the complete dimensions and type of filter mediaused shall be annexed and include the fow diagram also.b) Operation and maintenance manual with guide lines for troubleshooting shall alsobe provided after commissioning of the filter (2 nos).c) The floor shall consist of 40mm thick concrete,The finished floor level of thetreatment plant should be as per site condition with minimum of 60 cm higher than thenatural ground level.The plinth protection shall be 0.15m higher than the Natural levelie the floor level of the water treatment plant will be 0.45m above plinth protection.A1.0m wide plinth protection sloping to outside withcement concrete/interlockingpavers mix M135 with a thickness of 50 mm shall be provided all round the shedfoundation.Suitable /necessary foundation for pumps and filters shall be provided.b) Operation and maintenance manual with guide lines for troubleshooting shall alsobe provided after commissioning of the filter (2 nos).c) The floor shall consist of 40mm thick concrete,The finished floor level of thetreatment plant should be as per site condition with minimum of 60 cm higher than thenatural ground level.The plinth protection shall be 0.15m higher than the Natural levelie the floor level of the water treatment plant will be 0.45m above plinth protection.A1.0m wide plinth protection sloping to outside withcement concrete/interlockingpavers mix M135 with a thickness of 50 mm shall be provided all round the shedfoundation.Suitable /necessary foundation for pumps and filters shall be provided. |
| 22 | OD150007/2026-2027 :Supply, installation, testing and commissioning of a heavy-duty float-operated water level sensor/switch suitable for automatic ON/OFF control and low-level protection of pumpsets up to 3 HP, suitable for 230 V AC control circuit, with corrosion-resistant PP/HDPE float, IP68 protection, SPDT/SPST contacts, minimum 10 A contact rating, and 3-core flexible water-resistant cable of required length as per site, including suitable counterweight, fixing accessories and all necessary connections, complete in all respects. |
| 23 | 100.1.2: Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil |
| 24 | 100.1.5 ;Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock |
| 25 | 100.98.224 :Supply of PVC Pipe, 8kg/cm2, 110mm Dia. |
| 26 | 100.98.223 :Supply of PVC Pipe, 8kg/cm2, 90mm Dia. |
| 27 | 100.98.222: Supply of PVC Pipe, 8kg/cm2, 75mm Dia |
| 28 | 100.98.234: Supply of PVC Pipe, 10kg/cm2, 63mm Dia |
| 29 | 100.98.233: Supply of PVC Pipe, 10kg/cm2, 50mm Dia |
| 30 | 100.9.9 :Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes |
| 31 | 100.9.8 :Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes. |
| 32 | 100.9.7: Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes. |
| 33 | 100.9.6 :Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. |
| 34 | 100.9.5 :Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes. |
| 35 | 50.18.9.21.10 :Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x63 mm dia Reducer |
| 36 | 50.18.9.21.4 :Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend |
| 37 | 50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 38 | OD150367/2026-2027: Supply and fixing of valves |
| 39 | OD150008/2026-2027 :water quality test (grey water) |
| 40 | 18.48: Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 41 | OD150001/2026-2027 :Name Board |
| 42 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 43 | 100.98.1022: Engaging Rock Breaker |
| 44 | 16.68 :Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 45 | 10.16.1: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 46 | 16.70.1:Providing and fixing G.I. chain link fabric fencing of required width in mesh size50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers asrequired complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia4 mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender