Tender For Setting Up New District Level Waste Water Testing Laboratory Including Procurement Of Lab Instruments At Yamuna Nagar Under The Jurisdiction Phed No. 2 Yamuna Nagar. Procurement Of Instruments For Testing Of Waste Water Including Annual Ma
Tender Overview
Project Description
Tender for Setting Up New District Level Waste Water Testing Laboratory Including Procurement Of Lab Instruments At Yamuna Nagar Under The Jurisdiction Phed No. 2 Yamuna Nagar. Procurement Of Instruments For Testing Of Waste Water Including Annual Maintenance Contract For Analytical Balance And Cod Thermo Reactor With Photometer And Comprehensive Maintenance Contract For Do Meter With Optical Probe And Oxy-Top/ Bod Respirometer And All Other Works Contingent Thereto.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Executive office 6x 3.5 Table with Glass and foam having drawers with lock with termite proof plywoodand good quality sunmica |
| 2 | Supply Modular Wooden Rack (1.52x1.52 with depth 0.32) with 5 shelves.with termite proof plywood and goodquality sunmica |
| 3 | Fire extingisher ABC type |
| 4 | Providing and fixing of 1.No large voltage stablizer as per the requirement of building |
| 5 | Supply of office 5x 3.5 Table with Glass and foam having drawers with lock with termite proof plywood and goodquality sunmica |
| 6 | Supply of computer table of 3.5x 2.0 Table with Glass and foam having drawers with lock |
| 7 | Supplying of 20 watt led tubelight of Philips/Syska/Havells |
| 8 | Supply office Visitor cahirs with cushioned ,heavy steel arms |
| 9 | Item :- Calibrated WeightsSpecifications : - Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights)Make :- Radwag, Mettler Toledo, Sartorius, denver, wensar |
| 10 | (Glassware) Pipette 10 ml (Single Mark) Borosil AGrade |
| 11 | (Glassware) Lab Coat-Good Quality |
| 12 | AutoclaveMake: NSW, Ambassador, Impact• Digital Display• Heater: 4.0 kW• Size: 400 x 600 mm (78 L)• It should have double wall construction with boiler made of Stainless Steel 16-gauge sheet. Outer shall be also made of Stainless-Steel Sheet/ Mild Steel. Boiler and outer shell are provided with air insulation. Lid is made of Stainless-Steel Sheet and tightened all-round by radial locking. Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested upto 40 PSI.• Should have fully automatic PIO Controller• Unique design of Radial locking for minimum steam loss, assure accurate steam generation/ sterilization• Outer SS sheet chamber inner S.S. 304• Pressure accuracy: PSI ± 3 PSI or better• Automatic timer electronic 999 minutes• Sterilizers are fitted with water level arrangement to indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fitted with indfosspizzostat and can be set between 10 to 20 PSI.• Inner and outer wall both made of Stainless Steel. Lid is made of thick machined stainless-steel plate. Support ring and legs are also made of stainless steel. Gasket is made from imported SILICON rubber. Fitted with microprocessor based fully automatic fuzzy logic control system with timer buzzer (Auto Time Control). The unit is also fitted with low-water level cut-off as a standard feature. Fitted with automatic purging and exhaust valve.• Immersion type heating element heats the water and steam to desired temperature and pressure are attained. Autoclaves to cut-off automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply.• Steel stand should be provided along with tyres on which instrument has to kept.• Traceability calibration certificate of controller should be provided• Instrument should be calibrated from NABL calibration laboratory.• Vertical or horizontal will be decided by the concernedlaboratory |
| 13 | Laboratory RefrigeratorsMake: Cellfrost, Haeir, Whirpool• Storage Temperature: 2-8°C, Vertical Shelves at least 6 for storage of samples, Storage Capacity 500 Litres along with in-built digital temperature controller (company fitted).• Door for restricted accessibility. Castor wheels for easy mobility. Toughened glass door.• Enabled digital temperature controller to check and maintain inside temperature.• NABL calibration certificate.1 year warranty as desired by concerned lab. |
| 14 | Analytical BalanceMake: Radwag, Mettler Toledo, Sartorius, Shimadzu• Analytical Balance, Capacity 220 gm, Accuracy/resolution 0.01 mg with internal calibration Pan Size 0 90 mm along with NABL Calibration certificate.• Provide Acrylic sheet cabinet box along with weighing balance (2 feet x 2 feet x 2 feet) or as required by laboratory.• 1 year warranty. |
| 15 | Muffle FurnaceMake: Ambassdor, NSW, Optic, Impact, Skybond• Rectangular Muffle Furnace: Maximum Temp. 950°C working temp.900°C.The outer casing is made of double walled thick P.C.R.C. sheet painted with attractive stove enamel. Outer body of S. S. 304 grade. Heating elements are made of KANTHAL wire backed by cera wool insulation. temperature control unit consists of Energy regulator and Digital Indicator with silver thermal fuse or with PIO Micro Processor controller dual display with safety alarm to work on 220/230 volts AC with an accuracy of± 2°C or Better.• Along with Digital timer of 99.59 Hours, size -10x5x5 inches. Control panel- Mains, Load Indicator, Digital Controller and Mains Indicator.• NABL Calibration certificate |
| 16 | Manifold Filtration AssemblyMake: Pall Lifesciences, Merck Millipore, Borosil, Labotronics, Athena, Axiva, Glassco• Branch - 6 Place assemblies with High efficiency, High sensitivity and Fast filtering speed• Funnel capacity- Minimum 300ml. Filth pore size - Minimum 20µm• Funnel material -All SS 316 within built SS Clamp and SS lid Glass or SS316 with external ss clamp and cork capacity 250 ml• Vacuum flask 2L capacity• Valve - PTFE• Base holder - stainless steel 316L, Autoclavable- 121°c (15min.)• Membrane filter 1 pack (100 No.) as per requirement/0.45µm pack of 100• With all accessories, flask, connectors• vacuum pump: air vent filter-hydrophobic PTFE (Flow rate should be 19L/min. Motor speed -1400 rpm, Max vaccum-100 mbar) should be of latest technology and highest quality |
| 17 | Hot Air OvenMake: NSW, Optics Technology, Ambassdor, ImpactHOT AIR OVEN: -• Size: 18x18x24 inches• Precise Sterilization, Incubating and drying in one unit.• Better mineral / glass wool blanket insulation keeps the surface of the Instrument from being burnt.• Silent Hot Air blower unique Design of air circulation for uniform Air movement.• Unique design of Ventilation keeps the surface of the instruments from being burnt.• Polish 304 grade S.Steel interior corrosion resistant long-life operation having adjustable shelves to make more space for different height.• Kanthal A-1, Super quality coil shaped heaters duly embedded I wounded on the sides and bottom for better accuracy.• Full feature with Touch Screen ControllerTemperature Controller:• HMI Display with Feather Screen Touch Digital Temperature Controller• Continuous display of Temperature, Time, Day and Date Door Open Alarm• Password Protected operations,• Data transfer port: USB portTechnical Specification:Microprocessed Electronic Digital Controller cum Indicator from few `C above ambient to 300°C ±0.5°C having two windows display SV (Set value) and PV (Process value), auto tuning, timer up 999 min (selectable) low and high temperature accuracy alarm, cycle, timer with buzzer.• Temperature Stability: ± 0.5°C• Control Panel: With Mains and Load Indicator, MCB Alarm• Material: GI/ MS with Powder Coated• Inner: Stainless Steel 304• Digital Setting: 0.1°c• Digital Resolution: 0.1°c• Safety Function: Temp Over shoot high and Low Temp. Alarm ± 5°C, MCB Provided• Insulation: Mineral Wool• Front Door: Mineral wool insulated door with glass window• Hardware: Lock and Handle Material Zinc, Base Finish: SPC, Handle Finish: Black PC with key Hinges Material Zinc, Pin Material: SS 304 Grade, FinishSTPC, Opening Angle: 180 Deg• Power Consumption: 220 /230V AC Supply± 10%. 50 HZ• Duty Cycle: Continuous• Traceability calibration certificate of controller should be provided.• Instrument should be calibrated from NABL calibration laboratory. Steel stand should be provided along with tyres on which instrument has to be kept. |
| 18 | HygrometerMake: HTC, Testa• Temperature Range: -50.0°C - plus 70.0°C Temp.• Measuring Accuracy: ± 10°C Temp.• Resolution: 0.10°C Humidity• Measurement Range: 10% RH - 99%• Humidity Accuracy: ±5% RH• Humidity Resolution: 1%.• Along with NABL calibration certificate |
| 19 | Separating FunnelMake: Borosil, Therofischer, Glassco, Duran• Separating, Pear Shape, Fitted with Boroflo Stopcock with PTFE Key and Interchangeable Stopper Complies with IS 1575, DIN/ ISO 4800 Y Made 3.3borosilicate glass, USP Type I Y Equipped with aBoroflo stopcock with PTFE key Y Pear shape, with a stem Y Generally used in the separation phase 6402- Funnels ,2000 ML Capacity along with stand |
| 20 | Magnetic Stirrer with Hotplate (5 Station)Make: Borosil, Thermofisher Scientific, Glassco• Magnetic stirrer 2 litres capacity with hot plate and Digital Speed Indicator• Speed: 2000 RPM• Heating Plate Material: Glass Ceramic Top Plate• Dimension of Heating Plate: 180mmx180mm• Two display windows for Temperature and RPM• Heat Output: 1300 W• Temperature Range: Ambient to 550°C• Adjustable safety cut off: 580°C• Control accuracy of sensor: ±1K• Permissible ambient Temp.: 5- 40°C• Permissible relative moisture: 80%• USB Port: Yes (for Programming)• 7 pcs Magnetic stirring bar inclusive• Dimensions of Hot Plate Body: 378 mm x220 mm x103 mm• IP Class -21 |
| 21 | DO meter with Optical ProbeMake: Thermo, WTW, Hach, Metrohm, Lovibond• Display LCD with backlight illumination• DO barometer ±3 mbar, and resolution 1 mbaraccuracy• DO calibration Twopoints 100% (water saturated air (100%)calibration100% with O (water saturated air (100%) calibration with O point• DO measuring `0.00 - 8.00 mg/L: ±0.1 mg/Laccuracy mg/L 8.00 - 20.00 mg/L: ±0.15 mg/L• DO measuring 0.00 - 20.00 OR it can be morerange mg/L than / 1 - 200% saturation• Operating o to 50°CTern range• DO measuring 0.1% resolution % saturation• DO measuring 0.01resolution mg/L• DO selectable % air sat: mg/L: ppm: µmol/L:measuring mbar: torr: dphiunits• DO 0.0 - 60 °C, with 0.1°C resolutiontemperature range• Memory size 500 or more measured values• mV accuracy ±0.2 mV• mV range -1,2300.0 mV - plus 1,200.0mV/*1500-1500mv• mV resolution 0.1 mVLithium-polymer rechargeable• Power supply battery 3.7 V: 3,000mAh• Protection IP67 Probe type-rugged probeclass Stirrer for DO Meter and Rechargeable battery along with the recharger are inclusive |
| 22 | COD Thermoreactor with PhotometerMake: Lovibond, Hach, WTW, MerckCOD Photometer• Display (Photometer for COD Analysis)- Backlit Graphic Display• Interfaces- Bluetooth Connectivity• Optics- LEDs, Interference Filters (IF) and photo sensor• Wavelength Accuracy-± 1 nm• Photometric Accuracy- 3% full scale (at 20 ° C to 25 ° C)• Measuring range of absorbance: -2500 to 2500mAbs• Cells and Adaptor facility-16mm and 24 mm.• Pre-programmed Methods- Instrument should have preprogrammed method for COD analysis• Memory Capacity- It should be able to store the 125 data sets with time, date, sample ID• Protection- conforming to IP 68• Auto off- Auto off function should be available• Power supply- It should be battery operated.• Extra battery will be provided along this equipment. Rechargeable cells with charger are included.• Vials/Cuvette for different Sizes are included to perform testCOD Thermoreactor (15 holes or more): -• Three Temperature RangesThe reactor can operate optionally with 100°C, 120°C or 150°C - depending in each case on the sample to be prepared.• Three Different Reaction TimesThree different reaction times are available with 30, 60 and 120 minutes. Your advantage: Afterwards the unit switched itself off automatically.• Large Cuvette ShaftPlace up to 24 ,16-mm-round cuvettes• Heating-up Rate-20 °C - 150 °C• Selected Time-30 / 60 / 120 / 150 / minutes and continuous operation. |
| 23 | Oxy-Top/ BOD respirometerMake: Hach, WTW, Velp Scientific, Lovibond• Number of sensors per system:6• Sensor display: 4-digit LED Display• BOD Measurement: mg/I directly on display• BOD Scales: 0,250,600,999,4000 ppm,higher value after dilution• Bottle volume is 500 ml• Data storage: BOD value at 24 hr intervals• Includes 6 No. bottles with all type`s accessories• Provide chemical for 500 tests |
| 24 | Kjeldahl EquipmentMake: BOROSIL, Buchi, Foss, Velp, GlasscoDistillation system for Nitrogen estimation • Microprocessor controlled automatic distillation, steam addition, alkali addition, boric acid addition and auto tube drainage• Pre-defined editable user storage program• The unit can work with distilled water can or direct tap water with water softener.• Body constructed of glass reinforced polymer for enhance durability• Programmable Reaction Time with Continuous real time monitoring of steam temperature, display at the time of water filling and other parameters• 7` touch screen display and Tube capacity of 250ml and 400ml• Reagent level sensors• Removable bottom tray material perfluoroalkoxy for extra protection against acidic attack• Threaded tube connectors for quick removal of glass components for maintenance• Auto tube inserts error indication.• Easy water and steam drainage from the boiler for effective steam generation.• Automatic Steam dosing in test tube with user selectable from 10% to 100%• Combined bulb and coiled condenser with condensing surface area 550 Sq cm, SS 304 steam generator• Heat delay of less than 240secs• Distillation collection time (mins) of 5-7mins for recovery of more than 99.5%• Cooling water flow rate with minimal of 0.5L/min• One point calibration of Water and NaOH pumps.• 2-point calibration for acid pump with an accuracy of 0.1ml.• Inbuilt Nitrogen calculator with Nitrogen and protein in different formats• Interface provided for connectivity to printer or PC• Nitrogen recovery )99.5%, Nitrogen reproducibility±1 %, RSD of (1%, Nitrogen levels of 1-200mg with LOO of0.1mg of Nitrogen Digestion system for Nitrogen estimation• 250mL, 6 position capacity block digestion system of 220/230 V• Maximum temperature 470 °C with precision of ± 1oc.• Front Glass Reinforced Polymer control panel• Graphical representation after end of the cycle with LCD display. PIO based control system• Single point and two-point calibration of temperature• Pre-defined memories of which more than 20 are user-programmable• Ramping of at least 4 ramps per program• Data transfer port for PC or printer connectivity• Auxiliary cooling stand with thawing fans for faster sample cooling.• 2.8 KW SS316 cased cartridge for long heater life.• All essential accessories like digestion tubes, SS insert rack, exhaust manifold, suction assembly for safe removal of acid fumes to be provided with the unit. Fume extraction system for Nitrogen estimation• Fume scrubber with 28 LPM capacity for complete evacuation of acid fumes.• 2 litre condensation and neutralisation jars for larger fume volumes.• MOC for bottles 3.3. expansion borosilicate bottles and body epoxy painted• 29/32 ground glass with viton liners for quick removal and assembly of condenser and fume trap• Threaded tube connectors for quick removal of glass components for maintenance• Transparent PC Protective front shield and easily removable bottle tray.• Carbon adsorption bottle removal any trace acid from exhaust air• Four-way acid neutralisation through Condenser, trapping in distilled water, trapping in Alkali trapping and Carbon filter• Vacuum technology for water circulation for long life of the pump• Automatic cooling water cut off post process completion for water saving• online demonstration before technical qualification• Customer appreciation letter on customer letterhead and relevant POs to be provided minimum 20 nos.Chiller with Kjeldahl System• Recirculation system is designed to reduce energy consumption and maximize refrigerating efficiency.• Temperature ranges from -10°C to Ambient (CHL)• High cooling capacity up to 1kW at 20 deg.• Easy-to-read LED display with interactive touch keys.• Setting and resolution indication 1 deg.• PU Wheels for High-Capacity Models easy mobility• 100 test chemicals along with this equipment.• Self-diagnostic function identifying errors viz. Temp Probe / Compressor. |
| 25 | BOD IncubatorMake: Ambassdor, Optics Technology, Impact, Thermic, NSW• Capacity: 171L• Volume: 6 Cu ftRefrigerated Insulation and Freezing in one unit.• Puff Insulated to keep the surface Temp. of body comfortable and avoid Cooling loss.• Silent energy saving Kirloskar/ Tecumseh compressor,• Polish 304 grade S. Steel interior corrosion resistant long-life operation having adjustable shelves to make more space for different Height.• Kanthal A-1 tubular heater is fitted for better accuracy.• Safety Controller are provided with the Digital TemperatureController Cum Indicator.• Full features Touch Screen Controller• Inner glass door with Aluminium Frame Powder coated full view door to observe the Test.• Angle Iron Frame at bottom with castor wheel for easy movement.• Fitted with 2 Nos. Fan (One for Cooling and One for Heating inside the chamber)Technical Specification• Temperature Range: 5°C- 60°C• Temperature Stability: ± 0.5°C Max• Material: GI Sheet with powder Coated• Inner: Stainless Steel 304 Grade• Safety Function: Safety Controller for safety of Digital Temp. Controller Cum Indicator and Cooling Compressor with MCB.Temperature Controllera. HMI Display with Feather Screen Touch Digital Temperature Controllerb. Continuous display of Temperature, Time, Day and Date Door Open Alarmc. Password Protected.d. Data transfer port: USB port• Cooling: Fan Cooled,• Nominal Power: - 1/3 hp,• Voltage Range: - 187-264 V, Type CSR• Refrigerant: R134a• Along with installed UPS Battery/UPS System-2KVA• Included castor wheels for easy mobility of the equipment• Duty Cycle: Continuous• Along with NABL Calibration certificate |
| 26 | Heating MantleMake: Borosil, Glassco, DAN Logitech• Flask capacity -1 L, automatic spill detection and safety shutdown.• Safe temperature setting to prevent accidents.• Chemical and heat resistance plastic used for the control panel.• Rotary knob for precise setting of temperature and time. Integrated PIO control for better temperature accuracy.• Built in calibration for error setting. Includes PT 100 external temperature probe with auto detection on plug in• Large character digital display for better visibility.• Digital timer with 1 to 999 min time setting.• Digital energy regulator with 10 step power regulation. Integrated retort rod hold.• LED Display with time, temperature and process status, Ambient to plus 5°C to 400°C, Temp accuracy -±1.0°C, Timer- 1-999 Minutes |
| 27 | Lab Ware DryerMake: Borosil, IKA, Fisher Scientific• Optimum air circulation that dries lab ware in lessthan 15 mins, perfectly dried lab ware for error free experiments, Bench top and Wall mountable unit., assorted stainless steel easy to clean Pegs Heater (ON / OFF) feature for drying plastic ware.• Number of pegs - 22,• peg size volume compatibility: 16mm-12 nos.,10mm- 10 nos.,• Temperature Range (C) - Ambient to 70° C,• Time control - Yes,• drying power - 1075 W,• Dimension (W x D x H) - (400 x 367 x 620 mm). |
| 28 | Turbidity meter (Benchtop)/ (Portable)Make: Hach, Thermo scientific Eutech, WTW (Xylem), Lovibond• Parameter: Turbidity• Range: 0-1000 NTU or more• Certifications: CE certified• Compliance Certifications: CE/WEEE or ISO 7027• Interface: Optional USB• Source Lamp: Tungsten filament lamp/ Infrared-emitting diode (850 nm wavelength)• Data logging: Minimum 500 records• Display Size: Standard• Display Type: Graphic LCDMeasurement method• Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal/ ISO 7027 compliant nephelometric method• Operating temperature range: 0 - 50 °C• Power Requirements: 100 - 240 V AC/ 50/60 Hz (with optional Power or USB plus Power module)• Power Supply Batteries (see Battery Requirements) or Optional Power Supply: 4 x `AAA` Alkaline Batteries• Repeatability: ± 1 % of reading or 0.01 NTU, whichever is greater• Accuracy: ± 2 % of reading plus stray light/( 0.1 NTU for 0.02 NTU standard: ±2 % of reading ±1 digit for 0to 500 NTU: ±3 % of reading ±1 digit for 501 to 2000 NTU• Reading modes: Normal (Push to Read)• Signal Averaging Rapidly Setting Turbidity• Response time: Minimum 6 s in normal reading mode• Stray Light: ( 0.02 NTU• Max. Operating humidity: 0-90% RH• Warranty: Minimum 12 months• Weight: standard• Enclosure Rating: IP67/ABS Plastic• Included Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, Stablcal ampule kit, silicone oil, oiling cloth, manual. / Four AAA-sized batteriesare included in the packaging. |
| 29 | Deep Freezer with Temperature ControllerMake: Blue Star, Cellfrost, Western• Double door deep freezer• Capacity: 300L• Temperature Range: 2°C to 8°C• Heavy duty wheel• Enabled temperature controller to check and maintain inside temperature• Shelf Material/Cool pad: Toughened Glass• Aesthetic soft look design.• UV grade plastic material for long-lasting appearance.• Door lock for restricted accessibility.• Castor wheels for easy mobility.• Environment friendly CFC free insulation.• Instrument should be calibrated from NABLcalibration laboratory as desired by concerned lab. |
| 30 | Water bathMake: Borosil, Memmert, Thermofisher, Glassco• Nominal capacity - 20 L, 8 holes with lid assembly• Working Temperature range - ambient to 99°C• Temperature stability ±2.0°C• Interior dimensions (528 x 325 x 150) mm• Exterior dimensions (W x D x H) (530 x 326 x 2600) mm• Display 7 Segment LED Display Tank material SS 304• Outer body SS 304• Electrical Requirements 9 A• Power Consumption 1600 W• Calibration certificate from NABL Lab |
| 31 | Annual Maintenance Contract for Analytical Balance and COD Thermo reactor with Photometer complete in all respect for 2nd year after completion of warranty for 1 year. |
| 32 | Comprehensive Maintenance Contract for DO meter with Optical Probe and Oxy-Top/ BOD respirometer complete in all respect for 2nd year after completion of warranty for 1 year. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender