Tender For Electrical Rewiring Of 5 Nos. Officers Flats In Sector 30A Colony Of Reserve Bank Of India, Chandigarh
Tender Value
9.82 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
20 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Rewiring Of 5 Nos. Officers Flats In Sector 30A Colony Of Reserve Bank Of India, Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Light/ exhaust/ ceiling fan point/ Call bell Point wiring in 3 x 1.5 sqmm copper FRLS wire, including the length of lighting circuit in 3 x 2.5 sqmm, in HMS PVC FRLS conduit as per “Technical Specifications” given in Section IV of this tender document for one point controlled by one 6 Amp. Modular type switch housed in metal box and modular plate as directed. (No separate measurement for length of circuit/ switch plates/ back boxes shall be carried out)No. of points per flat= 42 nos.No. of points for 5 flats= 210 nos.(Rate inclusive of GST, as applicable) Location No. of pointsHall 6Bedroom big 4Changing room 1Bedroom small 3Servant room 3Kitchen 4Bathroom 1 3Bathroom 2 3Bathroom 3 3Dining Area 3Entrance lobby 1Balcony small 1Balcony big 3Outer portico 2Call bell 2 |
| 2 | Supply, installation, testing and commissioning (SITC) of Ding- Dong call bell with connections and all accessories as per site requirement as complete directed by Bank’s Engineer. Qty per flat= 2 nos.Qty for 5 flats= 10 nos.(Rate inclusive of GST, as applicable)Location No. of pointsHall 1Servant room 1 |
| 3 | SITC of independent one number 3 pin 6 A modular socket controlled by one number 6 A modular switch housed in metal box and modular plate of suitable size wired using 3x2.5 sqmm PVC flexible copper FRLS wire laid through recessed PVC heavy duty conduit pipe complete all accessories as per site requirement on wall as directed By Bank's Engineer. Qty per flat= 14 nos.Qty for 5 flats= 70 nos.(Rate inclusive of GST, as applicable) Location No. of pointsHall 2Bedroom big 2Bedroom small 2Servant room 1Kitchen 4Dining Area 2Outer portico 1 |
| 4 | 6A point on switch Board- SITC of 3 pin 6 A modular socket controlled by 6 A modular switch housed in GI box and modular plate of suitable size wired using 3x2.5 sqmm in Light/ Fan switch board.Qty per flat= 11 nos. Qty for 5 flats= 55 nos.(Rate inclusive of GST, as applicable) Location No. of pointsHall 1Bedroom big 1Changing room 1Bedroom small 1Servant room 1Kitchen 1Dining Area 1Entrance lobby 1Balcony small 1Balcony big 1Outer portico 1 |
| 5 | SITC of 3 pin 16 A modular socket controlled by 16 A modular indicative switch housed in GI box and modular plate of suitable size wired using 3x2.5 sqmm PVC flexible copper FRLS wire, directly from the MCB DB, laid through recessed PVC heavy duty conduit pipe complete all accessories as per site requirement on wall as directed By Bank's Engineer. (Primary point direct from MCB DB)).Qty per flat= 12 nos. Qty for 5 flats= 60 nos.(Rate inclusive of GST, as applicable) Location No. of pointsHall 1Bedroom1 1Bedroom2 1Servant room 1Kitchen 3Bathroom 1 1Bathroom 2 1Bathroom 3 1Dining Area 1Balcony big 1 |
| 6 | SITC of independent secondary 3 pin 16 A modular socket controlled by 16 A modular indicative switch housed in GI box and modular plate of suitable size wired from primary point in item no.5 above using 3x2.5 Sq.m.m. PVC flexible copper FRLS wire laid through recessed PVC heavy duty conduit pipe looped from primary point (item no. 5 above) complete all accessories as per site requirement on wall as directed By Bank's Engineer.Qty per flat= 4 nos. Qty for 5 flats= 20 nos.(Rate inclusive of GST, as applicable)ocation No. of pointsHall 1Bedroom big 1Bedroom small 1Kitchen 1 |
| 7 | Supply and fixing of 2 module 5-step electronic regulators of minimum 100 watt for ceiling fans on the existing switch boards.Qty per flat= 6 nos.Qty for 5 flats= 30 nos.(Rate inclusive of GST, as applicable)Location No. of pointsHall 1Bedroom1 1Bedroom2 1Servant room 1Dining room 1Back Yard 1 |
| 8 | Supply & Providing conduit for TV cable point with RG-6 socket, plate and box, independently with suitable dia. PVC heavy duty conduit (separate from lighting and power points) in a way as described in item 1.0. The rate shall include for providing modular TV sockets with respective make, required size mounting plate fixed on metal box concealed in wall as directed by Bank's engineer.) Qty per flat= 5 nos.Qty for 5 flats= 25 nos.(Rate inclusive of GST, as applicable)Location No. of pointsHall 1Bedroom1 1Bedroom2 1Servant room 1Dining room 1 |
| 9 | Supply & Providing wiring for telephone point by providing one junction box at the entrance of the flat, and connecting to the incoming intercom cable with two pair 0.5 mm dia. unarmoured bare copper conductor PVC insulated PVC sheathed telephone cable in suitable dia. PVC heavy duty conduit in a way as described in item 1.0. Rate shall include for providing of RJ-11 jacks single with shutter on suitable GI box with front plate and respective make required size mounting plate fixed in metal box concealed in wall, termination of the telephone wire at both ends.Qty per flat= 4 nos.Qty for 5 flats= 20 nos.(Rate inclusive of GST, as applicable)Location No. of pointsHall 1Bedroom1 1Bedroom2 1Dining room 1 |
| 10 | Supply, installation, testing and commissioning of three phase (TPN) 6 way (8 incomer + 18 outgoing) MCB DB, metal double door factory fabricated, IP 43 protection in surface/ concealed manner complete with loop connections , earthing Etc. comprising of following MCBs complete as directed. (Rate inclusive of GST, as applicable)32 A FP C-Curve MCB as incomerMin. 32 A RCCB FP with 30 mA sensitivity20A SP C Curve MCB Ik=10kA – 6 nos. 16A SP C Curve MCB Ik=10kA –5 nos. 10A SP C Curve MCB Ik=10kA – 7 nos. |
| 11 | Wiring with 3x2.5 sq.mm FRLS PVC insulated flexible copper wire in heavy duty PVC conduit (from nearest circuit board available or directly from DB) and supply, fixing, testing and commissioning of 2 Nos. of 3 pin 6 amp independent modular socket controlled by 2 Nos. of 6 amp independent modular switch fixed on modular plate and concealed metal box etc.Qty per flat= 5 nos.Qty for 5 flats= 25 nos.(Rate inclusive of GST, as applicable)Location No. of pointsHall 1Bedroom1 1Bedroom2 1Servant room 1Dining room 1 |
| 12 | Wiring for individual Inverter light point in PVC conduit pipe with accessories in concealed / surface manner with control wire 1*1.5 sq.mm. (White Colour/Grey) PVC stranded copper wire from balcony plug point to all light Switch board with accessories complete all as directed by Bank's Engineer. Qty per flat= 1 setQty for 5 flats= 5 sets(Rate inclusive of GST, as applicable) |
| 13 | Submain wiring: Sub main wiring: Supply & laying of 4C X 10 Sqmm Copper armoured cables FRLS 1100 V grade along with 2 runs of 10 SWG bare GI wire with all accessories partly over wall/surface and partly in concealed manner/false celling with all necessary accessories like saddle, glands, lugs, cable termination etc from meter four pole MCB to flat DB etc complete as directed by Banks Engineer. (Rate inclusive of GST, as applicable) |
| 14 | Supply, Installation, testing of min 20 W 4 feet LED light fittings (cool day light) including connection with flexible wire.Qty per flat= 10 nos.Qty for 5 flats= 50 nos.(Rate inclusive of GST, as applicable) |
| 15 | Supply, Installation of min 9 W, 2 feet LED light fittings (CDL) for mirror including connection with flexible wire.Qty per flat= 4 nos.Qty for 5 flats= 20 nos.(Rate inclusive of GST, as applicable) |
| 16 | SITC of 9 W CDL LED bulb with angle holder and back plateQty per flat= 8 nos.Qty for 5 flats= 40 nos.(Rate inclusive of GST, as applicable) |
| 17 | Supply, Installation of decorative wall bracket light fitting including connection with flexible wire.Qty per flat= 6 nos.Qty for 5 flats= 30 nos.(Rate inclusive of GST, as applicable) |
| 18 | Rebate for taking away old switch boards, switch, sockets, old conduits, tube lights, CFL, exhaust fans, MCB DB and MCBs and other scrap items removed from the flat excluding fans, geysers. water purifiers, chimney hoods etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender