Drinking Water Supply and Sanitation Government Departments Closing in 7 days TDR #58553445

Tender For Construction Of Rws&S Divisional Quarter Near China Market In Front Of Rws&S Division Office Pertaining To District Of Nabarangpur.

Issued by Government Departments · Nabarangpur, Odisha
Tender Value
2.62 Crore
Estimated cost
Bid Submission
27 Nov 2026
7 days left
EMD
2.62 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nabarangpur → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Rws&S Divisional Quarter Near China Market In Front Of Rws&S Division Office Pertaining To District Of Nabarangpur.

BOQ

Name of Work:- Construction of RWS&S Divisional Quarter near China Market in front of RWS&S Division Office pertaining to district of Nabarangpur.
Sl. No. Item Description
1CIVIL WORKEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.
2Excavation up to 1.5m height
3Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.
4Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.
5Providing and laying plain cement concrete of proportion (1:4:8) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.
6Providing and laying moorum sub-base by using moorum in shoulder in layers not exceeding 600mm watering and compacting to the required density in OMC with PRR with cost, conveyance, royality of materials, labour charges, T & P etc as required for the work complete in all respect as per speification and direction of Engineer in charge.
7Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
8Ground Floor
9Footing, Pedestal, Beam, Column, Slab, Staircase
10First Floor
11Beam, Column, Slab, Staircase
12Second Floor
13Beam, Column, Slab, Staircase
14Third Floor
15Beam, Column, Slab, Staircase
16Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge.
17Ground Floor
18Footing, Pedestal, Plinth Band
19Column, Roof Beam
20Roof Slab
21Staircase
22First Floor
23Column, Roof Beam
24Lintel
25Roof Slab
26Staircase
27Second Floor
28Column, Roof Beam
29Lintel
30Roof Slab
31Staircase
32Third Floor
33Column, Roof Beam
34Lintel
35Roof Slab
36Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
37Ground Floor
38First Floor
39Second Floor
40Third Floor
41Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth as per direction of Engineer-in-charge.
42Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
43Ground Floor
44First Floor
45Second Floor
46Third Floor
47Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(Inside)
48Ground Floor
49First Floor
50Second Floor
51Third Floor
52Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (Outside)
53First Floor
54Second Floor
55Third Floor
56Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm colour or printed series of approved make (JOHNSON /SOMANY/ KAJARIA/ OASIS) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand)jointed with neat cement slury and filling the joint with epoxy grout to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.
57First floor
58Second floor
59Fixing tiles of approved dimension area (25mm thick) in floor, treads of steps and landing on 25mm thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.
60Ground floor
61First floor
62Second floor
63Supplying, Fitting & Fixing granite tiles of approved dimension (25mm thick) in Cement Conrete base plate on 25 mm thick cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.
64Cement Concrete Base
65Kitchen Granite Tile
66Supplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators including cost of iron works and coal traing 2 coats or primer to wall side faces of choukaths including cost of coaltar, cutting grooves and mending sizes where necessary with cost and conveyance royalities and taxes of all materials and labour with T&P required for the work etc complete in all respect in all floors. as per drawing and technical specification and as directed by the Engineer-in-charge.
67All floor
68Supplying,fitting and fixing in position well dressed and well seasoned 32 mm thick piasal wood or local teak wood or Plywood paneled shutters and fixing (wrought and put up) in door windows including cost of iron works and coaltaring two coat wall side faces of chowkhats including costof coaltar cutting grooves and mending size where necessary with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors as per the direction of the Engineer-in-Charge.
69All floor
70Supply, fitting and fixing of all types of aluminium sheet doors with frames made of ISI-marked standard angles of approved thickness and quality, manufactured by approved manufacturers, complete with all required aluminium fittings, including cutting, fitting and mending to the required sizes as per requirement, including cost, conveyance and taxes of all materials, labour and T&P required for the work, complete in all respects as per approved drawing and technical specifications and as directed by the Engineer-in-Charge.
71All floor
72Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154,151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge.
73All floor
74Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
75All floor
76Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
77All floor
78Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.
79Ground floor
80First floor
81Second floor
82Third floor
83Painting two coats with plastic emulsion paint to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.
84First floor
85Second floor
86Third floor
87White washing two coats with shell lime to new plaster surface including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.
88Ground floor
89First floor
90Second floor
91Third floor
92Dismataling and removing R.C.C. Columns, Beams, Slab, Staircase landings, lintels including stacking the useful materials for reuse and removing the debris within 50m. Lead.
93EI Works
94Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.
95GROUP-A
96GROUP-B
97GROUP-C
98Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
99Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
100Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
101Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
102Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
103Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
104Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIV Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
105Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 nos of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit.(2X6+1X4)
106Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
107Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
108S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
109Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
110Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator)
111SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
112SITC Of 4Ft surface mounted/suspended Single Piece Constructed CRCA LED TUBE BATTEN required pre-wired terminal one side with body earthing provision - along with mounting of 1No.s Essential Glass T8 Base Tube 2200Lumen Pack,Efficacy >110Lm/W, 20Watt,CRI >=80, PF >0.9, CCT 4K, IP20, 25K Burning Hours Temp -20To45Degree,CE marking RoHS compliance KEMA Keur certificate.(Make: Panasonic/LT/Havells /Philips((TMC502 1xT-LED 22W))/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.
113Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
114S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
115Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
116Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years .
117Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
118Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
119Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
120Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
121Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
122Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
1233.5core x 50 sq mm
1244core x 16 sq mm
125Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
126Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
127Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
128Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
129Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
1303.5core x 50 sq mm
1314core x 16 sq mm
132Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
13350 mm dia
134Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
135200 mm dia
136S/I/T&Commissioning of Main LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 40X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with 63 A 4P MCB, C series, 10 kA. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders.
137Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
138PH Works
139Earth work in excavation in Pipe Line Trenches in all kinds of soil with in 50m initial lead and1.50m initial lift including rough dressing and breaking clods to maximum5cm to 7cm in size and laying in layers not exceeding 0.30min depth and as per the direction of EIC.
140Earth filling in pipe line trenches with excavated earth(in all kinds of soil) including watering ramming including cost, carriage and royalty of all the materials etc. all complete.
141Supplying all materials labour, T&P and providing c.c. (1:2:4) using 12mm hg chips including watering, curing, conveyance of all materials to work site payment of royalty, taxes etc. all complete as per specification and direction of EIC
142Supplying all materials labour T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to work site payment of royalty, taxes etc. all complete as per specification and direction of EIC.12mm thick CP (1:4)
143Making R.C.C.Jally as per approved design 2.5 cm to 5.00 cm thick and fixing in cement mortar in position after cutting the grooves etc complete including cost of all materials
144Fixing digital floor tiles of size 1200mmx600mm in floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles in Ist floor including rubbing & polishing complete.
145Fixing digital wall tiles (300x450mm) to dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles in Ist floor including rubbing & polishing complete
146Supplying all materials labour T&P and cutting holes through brick/stone masonry works including making good the damages in cm (1:4) for taking H.C.I/PVC pipes and fittings etc. all complete as per PH specification and direction of EIC.250mm thick wall
147250mm to 375mm thick wall(holes of size 15x15x25cm)
148Supplying all materials, labour, T&P,and laying in trenches galvanized mild steel tubes (light grade) conforming to IS:1239-2004, Part-1 of the following nominal bore and tube fittings including testing all complete as per specification and direction of Engineer in Charge.(Earth work in trenches to be measured and paid separately)
14925mm. Dia distribution branch
15040mm. Dia distribution branch
151Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) etc all complete as per specification and direction of the E.I.C.(Hindware- Model no - Fluid Neo - size - 645x350x745mm)
152Fitting and Fixing of the following nominal sizes health Faucet ABS with 1.20 mtr long PVC Tube with ABS wall Hook as per specifications and direction of Engineer-in-Charge
153Health Faucet( code- ACD-CHR-573) make-Jaquar
154Supplying all materials, labour, T&P and fitting & fixing of wash basins with hole for pillar tap with cast iron or MS brackets painted including cutting holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C.
155Wash Basin (CEDAR Cat no- 90149 ) Hindware
156Fitting and Fixing of Brass pillar Cocks (Taps) Polished Bright conforming to IS:781-1995 of the following nominal sizes as per specifications and direction of Engineer-in-Charge
157Pillar Cock for wash Basin& sink- Jaquar(QQT-CHR-2701 )
158Pillar Cock Straight for bath- Jaquar(SOL-CHR-6047 )
159Supplying all materials, labour, T&P and fitting & fixing Chromiuim Plated Brass Shower Rose with 15mm or 20mm inlet including polishing etc all complete as per specification and direction of the E.I.C.
160Shower HeadMake-Jaquar(100x100mm BSH-CHR-1751)
161Fitting and Fixing of Brass Screw Down Stop Cocks/Angular cockPolished Bright conforming to IS:781-1995 of the following nominal sizes as per specifications and direction of Engineer-in-Charge
162Angular stop cockmake - Jaquar(ARI-CHR-23053 )
163Supplying all materials, labour, T&P and fitting & fixing Chromiuim Plated Brass Waste of the following nominal diameter for wash basin and sink etc all complete as per specification and direction of the E.I.C.
16432mm waste Coupling(ALD-CHR-705)
165Supplying all materials, labour, T&P and fitting & fixing 600x450mm bevelled edge mirror of superior glass mounted on 6mm thick AC Sheet or polywood sheet and fixed t wooden plugs with chromium plated brass screws and washers etc all complete as per specification and direction of the E.I.C.
166Mirror- Jaquar( AKP-CHR-35795 )
167Supplying all materials, labour, T&P and fitting & fixing (a) Liquid Soap Container - Glass Container or Plastic Container with chromium plated brass lid and brackets fixed to wooden plugs with chromium plated brass screws or (b) Chromium Plated brass Soap dish complete with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws or (c) white glazed tooth brush holder fixed to wooden plugs with chromium plated brass screws etc all complete as per specification and direction of the E.I.C.
168Soap Dish- Jaquar(AHS-CHR-1531 )
169Supplying all materials, labour, T&P and fitting & fixing Standard Size Chromium Plated Brass Towel Ring complete with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws etc all complete as per specification and direction of the E.I.C.
170Towel Ring - Jaquar( ACR-CHR-1121BN
171Supplying all materials, labour, T&P and fitting & fixing of stainless steel AISI 304 (18/8) Kitchen Sink with Cast Iron Brackets painted white and stainless steel plug 40 mm including cutting holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C.
172Stainless Steel Sink with Drain Board
173Supplying all materials, labour, T&P and fitting & fixing PVC Waste Pipe of following nominal diameter for wash basin or sink including brass check nut etc all complete as per specification and direction of the E.I.C.
17432mm waste copling
175Supplying all materials, labour, T&P and fitting & fixing Standard Size Glass Shelf with chromium plated brass brackets and guard rails complete, fixed to wooden plugs with chromium plated brass screws etc all complete as per specification and direction of the E.I.C.
176Providing and laying in trenches Chlorinated Polyvinyle Chloride (CPVC) Pipes conforming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per specification.
17740 mm dia. CPVC Pipe, Schedule 80
17832 mm dia. CPVC Pipe, Schedule 80
17925 mm dia. CPVC Pipe, Schedule 80
18020 mm dia. CPVC Pipe, Schedule 80
18115 mm dia. CPVC Pipe, Schedule 80
182Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
183Brass Gate Valve 40mm
184Brass NRV 40 mm
185Brass Gate Valve 32 mm
186Brass Gate Valve 25 mm
187Brass Float Valve 25 mm
188Supplying all materials, labour, T&P and fitting and fixing on wall face U-PVC SWR (soil, waste, rain water) ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C.
189110 mm PVC SWR Pipe (type -A)
190110 mm PVC SWR Pipe (type - B)
191110mm P.V.C.S.W.R.offset
192110mm P.V.C.S.W.R. plain bend
19375 mm PVC SWR Pipe (type -A)
19475mm P.V.C.S.W.R. plain bend
195Supplying all materials, labour, T&P and constructing Manhole Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C
196Man Hole Chamber of size (1.20x1.20x0.90 mtr ) with S.F.R.C M.H Cover
197Removal of sand ,mud & debries by mechanical means including cost of materials with taxes, transportation, all labours, T&P etc. all complete as per the direction of Engineer-in-charge. (spoiling at a distance of 8Km.)
198Providing and fixing Rotational Moulded Polyethylene Cylindrical Vertical Water Storage Tanks conforming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball balves etc including hoisting upto a height of 5.00 mtrs above ground level and placing the tank in the required position etc all complete as per specification and direction of Engineer in Charge.
1992000 ltrs Rotational Double Layer Cylindrical Vertical Water Storage Tanks
200Supplying all materials labour T&P providing & laying in trenches cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for salt glazed stoneware pipes . ( Type - A 1 Bedding) as per specification
201110mm dia Pipe
202Supplying all materials, labour T&P and construction of Inspection chamber of the following sizes with c.c.(1:3:6) using 40mm size hg metal on bed, Ist class KB Brick work in cm(1:6) moulding and shaping the channel inside and benching with c.c. (1:1.5:3) with punning to inside cement flush pointing (1:3) to outside RCC cover slab in cc (1:1.5:3) using 12mm size hg chips with RCC m. h. cover, e. w. in excavation in all kinds if soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty taxes etc. all complete as per approved specification and direction of EIC.Inside size : Inspection Chamber of size (0.75x0.75x0.45 mtr ) with S.F.R.C M.H Cover
203Supplying all materials labour T&P and construction soak way pit of the following sizes with dry brick walling from bottom upto invert of inlet pipe and Ist class KB Brick work in cm(1:6) for the remaining height at top 12mm thick cp (1:4) inside and outside over masonry brick work gravel packing the rear of well staining RCC cover slab in c.c. (1:1.5:3) using 12mm size hg chips fitted with iron lifting handles including e.w. in open well excavation in all kinds if soil and refilling the cavity around the pit and painting the iron works, watering, curing, conveyance of all materials to work site payment royalty, taxes etc. complete as per approved drawing specification and direction of EIC. 1.00m dia x 3.00m deep soak way pit
204Supplying all materials labour T&P and constructing 3.00m dia x 4.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58553445
AUTHORITY Government Departments
TENDER VALUE 2.62 Crore
LAST DATE 27-11-2026
Authority
Authority Name Rural Water Supply And Sanitation Division
Work Description Tender for Construction Of Rws&S Divisional Quarter Near China Market In Front Of Rws&S Division Office Pertaining To District Of Nabarangpur.
Basic Detail
Tender No 08/ACE/RWSS/KPT/26-27/03.11.26
Bidding Type Tender
Location
City Nabarangpur
State Odisha
Key Dates
Publish Date 16 Nov 2026
Submission Date 27 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 2.62 Crore
Tender Fee 10000
EMD 2.62 Lakhs
Exemption Available
Document List
be9f17d7-89bc-4386-8c88-6df851ab5a57.html
BOQ_621447.xls
DTCNNABARANGPURBUILDING.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

be9f17d7-89bc-4386-8c88-6df851ab5a57.html

xls

BOQ_621447.xls

pdf

DTCNNABARANGPURBUILDING.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender