Tender For special Repair To Toilets And Bathrooms Of Bldg No P-267 And 268 Smbk Of annual maintenance contract Records Under Ge (East) Lucknow
Tender Value
41.76 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
21 days left
EMD
83520
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Toilets And Bathrooms Of Bldg No P-267 And 268 Smbk Of annual maintenance contract Records Under Ge (East) Lucknow
BOQ
| Sl. No. | Item Description |
| 1 | M&L for brick work with fly ash bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed. |
| 2 | Demolition brick work/stone boulder masonry, built in cement mortar incl all quions, arches,pillars etc complte all as specified |
| 3 | M & L for brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed. |
| 4 | Material & Labour for preparation of old plastered surface(including complete removal of paint from old surface) /new surfaces of walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note:- (a) All quantity of material, paint, primer & PU Paint , whatever is specified by the OEM as the manufacturesv instruction shall be deposit with Engr-in-Charge.(b) Irrespective of whatever specified elsewhere in tender documents, the work shall be got executed through authorized executor of approved manufacturer’s only. The tri-party agreement between contractor, approved manufacturer and their authorized Applicator on Non Judicial Stamp paper of Rs 100/- shall be submitted before execution of work for approval of GE.(c) Work will be executed only ofter approval aforesaid MoU.(d) Format of MoU is attached with NIT and tender documents. |
| 5 | Complete removal of existing treatment or preparation of newly plastered surface of wall applying two coats of oil bond distemper over a coat of primer over a coat of wall care/ceiling putty 1 mm thick to make surface even and smooth, and complete all as specified and directed. Note:- All quantity of material, paint, primer & PU Paint , whatever is specified by the OEM as the manufactures instruction shall be deposit with Engr-in-Charge. |
| 6 | M & L for applying minimum 1mm thick wall care water proofing putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed.Note:- (a) All quantity of material, paint, primer & PU Paint , whatever is specified by the OEM as the manufactures instruction shall be deposit with Engr-in-Charge.(b) Irrespective of whatever specified elsewhere in tender documents, the work shall be got executed through authorized executor of approved manufacturer’s only. The tri-party agreement between contractor, approved manufacturer and their authorized Applicator on Non Judicial Stamp paper of Rs 100/- shall be submitted before execution of work for approval of GE.(c) Work will be executed only ofter approval aforesaid MoU. |
| 7 | M&L for rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm on newly prepared surface and plastering the wall surface with white cement based polymer modified self curing mortar, all complete as per the direction of Engineer-in-Charge. |
| 8 | Repair to plaster by using readymix mixture of thickness 12 mm to 15 mm and taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge. |
| 9 | Repair to plaster by using readymix mixture of thickness 5 mm to 7 mm in ceiling including taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge. |
| 10 | Demolition of sunken slab floor or WC and Bath including WC trap etc incl taking down loose filling of aggregate in any type and removing where direted and providing water proofing treatment of sunken slab in following . (a) 15mm thick rendering on vertical sides of RCC slab in CM 1:3 mixed with WP chemical Cement + of Nerolac Perma/STP/Asian Confirm to IS 2645 - 9103 as per manufacturer instructions. (b) Cleaning the concrete surface by brushing and watering and remove all surface inperfections. (c) Fixing 40mm dia PVC Pipe 450mm long bottom of the sunken and wraping of bath seal tape on the pipes inserted through walls to floor are and seal it (Perma Butyl tape product of Nerolac Perma/ STP/Asian and grouting around the inserted pipes by porable grout as directed by Engr-in-Charge.(d) Make angle fillets by mixing sand cement and Nerolac Perma Hypercrete/STP/Asian on all corners.(e) Brushing two coats with high performance cementitious elastomeric two components water proofing coating of Nerolac Perma Super 2K/STP/Asian of thickness 1mm in two coats, Above treatment shall be giving upto height 15cm from bottom slab and allow it dry completely. Above material shall be confirm to below properties- 1. Bulk Density - 1.73g/cc, 2. Elongation - 100% as per ASTM D412 (Min) 3.Hydrostatic Pressure - 4bars as per ASTM D 7088, 4. Adhesion to concrete- Greater than 1.5N/mm2, 5. Crack Bridging ability as per AS/NZS 4548.5 Min 1mm. 6. DFT - 1mm in two coats. Seperation Layer- Providing & Laying 120 gsm non woven geo textile membrane over waterproofing coating to protect the coating prior the screed.(f) Providing PCC 1:2:4 type B-1 using 20mm graded stone aggregate mixed with intergral waterproofing compound Cement + of Nerolac Perma as per manufacturer instructions in sunken slab for making slope to wrap hole.(g) Fill the sanitary gaps with Nerolac PermaSIKA/Asian sealing compounds complete. |
| 11 | M & L for providing PCC 1:7:12 type F-2 using 40mm graded crushed stone aggregate in sunken slab complete all as specified and directed. |
| 12 | Dismantling brick tiles or terracing tiles, single layer of roofs and old APP removal including mud pushaka,concrete etc roughening surfaces of old concrete by picking, sweeping/Brushing clean and washing down with water to remove dust and apply neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.Note : (a) Rubbish including mud phuska shall be removed from site to a distance of 1.5 KM out side MOD land at thier own arrangement. (b) U/S brick tiles shall be credited to contractor under Sch of credit. |
| 13 | M & L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs/padding /benching or mud stops, and platform for mounting service tanks, rounded,chamfered on edges including necessary use and waste of from work etc and mixed with liquid water proofing compound @200ml per 50 Kg cement bag etc all as specified and directed.Note : Liquid WPC shall be measured and paid seprately. |
| 14 | M & L for screed bed 10mm thick in CM 1:3 on concrete surfaces/ roof/ parapet wall using WPC as per manufacturer instruction finished fair & even without using extra cement complete all as specified and directed.Note : Liquid WPC shall be measured and paid seprately. |
| 15 | M & L for RCC 1:2:4 type B1 using 20mm graded stone agg in RCC lintel, shelves, RCC Parapets and the like including necessary form work complete all as specified and directed. |
| 16 | M & L for mild Steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for providing, cement concrete Type B1 1:2:4 (20 mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including dismantling concrete, weathering, slightly rounded or chamfered angles and throating, as directed. Please Enable Macros to View BoQ information |
| 18 | M&L for providing, cement concrete Type B1 1:2:4 (20 mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including dismantling concrete, weathering, slightly rounded or chamfered angles and throating, as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
TodayDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender