Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58553388

Tender For Addn/Altn To Wall Panelling In Conference Hall And Visitors Room In Cqa (Hv) And Addn/Altn To X-Ray For Room Of Mh Avadi Including Provision Of Roof Treatment Of Polycilinic Bldg Of Echs Polyclinic Avadi (Type C) Under Ge Avadi

Issued by Statutory Bodies & Commissions/Committees · Thiruvallur, Tamil Nadu
Tender Value
17.50 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
20 days left
EMD
35000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addn/Altn To Wall Panelling In Conference Hall And Visitors Room In Cqa (Hv) And Addn/Altn To X-Ray For Room Of Mh Avadi Including Provision Of Roof Treatment Of Polycilinic Bldg Of Echs Polyclinic Avadi (Type C) Under Ge Avadi

BOQ

Name of Work:- ADDN/ALTN TO WALL PANELLING IN CONFERENCE HALL AND VISITORS ROOM IN CQA (HV) AND ADDN/ALTN TO X-RAY FOR ROOM OF MH AVADI INCLUDING PROVISION OF ROOF TREATMENT OF POLYCILINIC BLDG OF ECHS POLYCLINIC AVADI (TYPE C) UNDER GE AVADI
Sl. No. Item Description
1PART -I- ADDN/ALTN TO WALL PANELLING IN CONFERENCE HALL AND VISITORS ROOM IN CQA (HV)
2Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
3S & F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
4S & F of Solid PVC Wall Lining consisting of 5mm thick Plain / Wooden Pattern of any colour / shade / texture PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
5PART -II- ADDN/ALTN TO X-RAY FOR ROOM OF MH AVADI
6Taking down of chowkhats / frames exc 1.50 Sqm but n exc 4.0 sqm each without taking off shutter each complete all as specified and directed.
7S & F of 44mm thick GPSP steel door shutter having outer skins with 2mm thick lead sheet core (X-Ray) having Lead Glass windows a vision panel size 200 x 300mm, for X-Ray room along with frames size of 100mm × 57mm & 1.6mm thick GPSP frame with lead-lined frame rebate and opening Inward / Outward inclusive of Non-ferromagnetic brass hinges hardware throughout, self closing hydraulic device and surface finish of Hospital-grade antimicrobial paint / powder coated of any colour all as specified and directed.
8Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as directed.
9Demolition of cement conctrete (un-reinfoeced) of any description and in any position not otherwise specifically provided
10M & L for 40mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) cement concrete in sub base complete all as specified and as directed.
11M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes like tiles complete all as specified and directed.complete all as specified.
12M & L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm / 450X 350X 7mm / 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles and including rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and directed.
13Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets
14Provding and fixing of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre ton centre. and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longcomplete all as specifed and directed.
15Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to any flat over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) complete all as specifed and directed.
16M & L for Providing and applying plaster of paris putty of 1 mm thickness over plastered / uplasterd ceiling surface to prepare the surface even and smooth and Material and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed by Engr-in-Charge.
17Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as directed.
18M & L for 15 mm thick plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and directed.
19M & L for preparation of newly plastered wall surfaces and Providing and applying 3mm thick wall care putty on wall to prepare the surface even and smooth, including priming plastered and other surfaces with alkali resistant priming paint and Material and labour for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed by Engr-in -Charge.
20Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
21Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly,including Modular boxes, frames and cover plates all as specified for the following:(a) One light point controlled by one switch.
22(b) One 3 pin 5 amps socket point on same board
23(c) One 3 pin 5 amps socket point on independent board
24M & L for point wiring with two runs of 4 Sqmm (nominal area) PVC insulated,FRLSH sheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories concealed with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified.
25Taking down carefully unserviceable Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 2 runs of 6 Sq.mm removing materials from site, taken as credit , making good the disturbed surfaces all as specified and as directed.
26M&L for wiring for circuit / power /sub main wire with two runs of single core 4 Sqmm size and one run of 4 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multi stranded copper conductor FRLSH cable drawn through including suitable dia PVC conduit concealed in wall and fixing arrangement on ceiling/trusses with suitable clamps,screws etc complete with accessories all as specified.
27M&L for wiring for circuit / power /sub main wire with two runs of single core 6 Sqmm size and one run of 6 Sqmm (green colour as earth continuity conductor) PVC insulated, sheathed, multi stranded copper conductor FRLSH cable drawn through including suitable dia PVC conduit concealed in wall and fixing arrangement on ceiling/trusses with suitable clamps,screws etc complete with accessories all as specified.
28Supply and Fixing Modular switch 1 way 6A, 1 module complete all as specified.
29Supply and Fixing Modular switch 1 way16A, 1 module complete all as specified.
30Supply and Fixing Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified.
31Supply and Fixing Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified.
32S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
33Taking down existing unserviceable MCB's/MCCB's/DBs any capacity complete all as specified & directed by Engr in charge.
34Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.(MCB for SPN DB)
35Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole Neutral and current carrying capacity 32-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.(MCB for VTPN DB)
36S&F MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
37S&F Load line vertical distribution Board, TPN 8 way double door, fixed on wall semi flush, loadline DB are fitted with Bus bars, neutral links, blanking plates, including incommer MCCB 100/125 Amps,TP and suitable outgoing MCB 40 /63Amps,SP/DP/TPN with all accessories suitable for DB including taking down old unserviceable DB all as specified and as directed. Note : Incoming MCCB and Out going MCBs measured seperately relevent items.
38Supply and fixing in replacement of LED tube light fitting with polycarbonate LED tube light 20W 4 feet and 1 x 20 watt box type batten aluminum body with microwave motion technology and integrated electronic driver including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
39S&F LED Panel light recessed 30/32 watt (2 x2 ),white powder coated CRCA full glow recess mounting LED Backlit Panel, integrated electronic driver complete including connection from ceiling rose to light fitting with twin core cable 23/0.0076 Sqmm complete all as directed.
40Supply and Fixing Modular fan step regulator , 120w, 2 module complete all as specified.
41Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
42Material and labour for GI earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge
43PART -III- PROVISION OF ROOF TREATMENT OF POLYCILINIC BLDG OF ECHS POLYCLINIC AVADI (TYPE C) UNDER GE AVADI
44Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and as directed by Engineer-in-charge.
45Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge.
46Taking out shrubs / vegetation / tree growth from building at any height & any location and applying a Glyphosate pesticide or any other equivalent pesticide in a 10ml of solution with one litre of water on roots using spray gun including taking down cement plaster not exc 0.50 sqm for each tree and making good surface by plastering the same area with 20mm thick plastering in cement mortar 1:4 with WPC and finishing the surface to mathc existing surface with necessary scaffolding and other required T & P complete all as specified and directed by Engr-in- Charge.
47Demolition of cement conctrete (un-reinfoeced) of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
48M & L for 40mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) (Padding concrete) with water proofing compound and finished even and fair complete all as specified and as directed by Engineer in charge. Note : Supply only water proofing compound will be measured and paid separately.
49M & L for screed bed of mortar 15 mm thick in cement mortar 1:4 for laying APP membrane and including mixing water proofing compound as per manufactureres instructions complete all as specified and directed by Engineer in charge.Note :- Water proofing compound shall be measured and paid for seperately under appropriate item of Sch \\"A' as supply only.
50Supply only Liquid water proofing compound all as specified and directed by Engineer in charge.
51M & L for brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and directed by Engineer in charge.
52M & L in repairs for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles and applying one coat of bituminous primer @ 200 gms per sqm and then laying 3 mm thick APP modified bituminous membrane weighing not less than 3.50 kg/sqm reinforced weighing not less than 160 gms/sqm laid by torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints and changes should covered with CM 1:3 with water proofing chemical as per manufacturer's instructions and cured well before laying membrane etc and applying aluminium paint @ 100 gram / sqm on roof or vertical surfaces complete all as specified and as directed by Engineer in charge.
53Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc. complete all as specified and as directed by Engineer in charge.
54M & L for precast cement concrete block masonry with solid blocks exc 10 cm in width and set and jointed in C M 1:6 having ratio of PCC 1:3:6 type C1 (using 20mm graded stone aggregate as directed complete all as specified and as directed by Engineer in charge.
55Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge.
56M & L for 15 mm thick plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and as directed by Engineer in charge.
57M & L for 5 mm thick plaster in CM (1:3) on brick work / RCC concrete surfaces of ceilings complete all as specified and as directed by Engineer in charge.
58M & L for rendering 15 mm thick in CM 1:4 on concrete / fair surfaces of block masonary and including mixing water proofing compound as per manufactureres instructions and finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge.Note :- WPC shall be measured and paid for seperately.
59M & L for preparation of newly plastered ceiling surfaces and applied three coats of white wash complete all as specified and as directed by Engineer in charge.
60M & L for preparation of newly plastered wall surfaces and Providing and applying 3mm thick wall care putty on wall to prepare the surface even and smooth, including priming plastered and other surfaces with alkali resistant priming paint and Material and labour for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed by Engr-in -Charge.
61M & L for preparation of newly plastered wall surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer in charge.
62S & F of 25 mm bore ball brass valves,high pressure,with polythene float and flunut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by Engineer in charge.
63S & F in repairs 25 mm bore dia gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer in charge.
64Dismantling water tanks and removing to store Exc 500 litre & n exc 1000 litre amd Supply and fixing of 1000 litre capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed by Engineer in charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58553388
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 17.50 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn To Wall Panelling In Conference Hall And Visitors Room In Cqa (Hv) And Addn/Altn To X-Ray For Room Of Mh Avadi Including Provision Of Roof Treatment Of Polycilinic Bldg Of Echs Polyclinic Avadi (Type C) Under Ge Avadi
Basic Detail
Tender No 8469/E8
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 16 Nov 2026
Submission Date 07 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value 17.50 Lakhs
Tender Fee 500
EMD 35000
Exemption Available
Document List
00a2511c-4ec4-484a-a90f-2a176bcb14a3.html
8469Tenderdocu.pdf
BOQ_896332.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

00a2511c-4ec4-484a-a90f-2a176bcb14a3.html

pdf

8469Tenderdocu.pdf

xls

BOQ_896332.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender