Tender For Construction Of Animal House Facility Including Civil, Electrical And Allied Services At Iiser Berhampur, Odisha.
Tender Value
1.17 Crore
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
2.35 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Animal House Facility Including Civil, Electrical And Allied Services At Iiser Berhampur, Odisha.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL |
| 2 | EARTH WORK |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | All Kinds of Soil |
| 5 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 6 | In all kind of soils |
| 7 | Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 9 | Supplying chemical emulsion in sealed containers including delivery asspecified. |
| 10 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 11 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): |
| 12 | Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 13 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 14 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 15 | Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :2.35.4.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 16 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 17 | CONCRETE WORK |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 19 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | DAMP-PROOF COURSE |
| 21 | Providing and laying damp-proof course 40 mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5 mm nominal size derived fromnatural sources) |
| 22 | PLINTH PROTECTION |
| 23 | REINFORCED CEMENT CONCRETE |
| 24 | Design Mix Concrete |
| 25 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 26 | All works upto plinth level |
| 27 | Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 28 | All works above plinth level upto floor V level |
| 29 | Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 30 | Form Work |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 32 | Foundations, footings, bases of columns, etc. for mass concrete |
| 33 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 34 | Suspended floors, roofs, landings, balconies and access platform |
| 35 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 36 | Columns, piers, abutments, pillars, posts and struts |
| 37 | Steel Reinforcement |
| 38 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. Make : TATA, SAIL, JSW (Fy 500 grade) |
| 39 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 40 | MASONRY WORK |
| 41 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars atevery third course of half brick masonry. |
| 42 | Brick work with clay flyash F.P.S. (non modular) brick of class designation7.5 in superstructure above plinth level up to floor five level in : |
| 43 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 44 | Half brick masonry with non modular fly ash bricks of class designation10, conforming to IS :12894, in super structure above plinth upto floor Vlevel. |
| 45 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 46 | DOORS |
| 47 | Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fast lugsor with dash fasteners of required dia & length (hold fast lugs or dashfastener shall be paid for separately). |
| 48 | Sal wood |
| 49 | Dash fastener / Chemical fastener |
| 50 | FLUSH DOOR Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 51 | 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 52 | Extra for providing lipping with 2nd class teak wood battens 25 mmminimum depth on all edges of flush door shutters (over all area of doorshutter to be measured). |
| 53 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete as per entire satisfaction and direction of Engineer-in-charge. |
| 54 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 55 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete Single rubber stopper as per entire satisfaction and direction of Engineer-in-charge. |
| 56 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). |
| 57 | Providing and fixing 50 mm thick Pivoted fire resistant door shutters with glass panel of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, floor springs, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). |
| 58 | Providing and fixing Carben Steel galvanised (min 5 micron) dash fastner (min 5 micron) of 10 mm dia double threaded 6.8 grade counter sunk head screw comprising of 10 mm dia polyamide PA 6 grade sleeve. Size 10 mm x 120 mm |
| 59 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm |
| 60 | Providing and fixing stainless steel tower bolts (barrel type) with necessary screws etc. complete : 200x10 mm as per entire satisfaction and direction of Engineer-in-charge. |
| 61 | STEEL WORK |
| 62 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 63 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 64 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 65 | M.S. tube |
| 66 | FLOOR FINISHING |
| 67 | Tile flooring work |
| 68 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 69 | Glazed Vitrified tiles Matt/Antiskid finish of size 600 X 600mm |
| 70 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 71 | Size of Tile 600x600 mm |
| 72 | ROOFING |
| 73 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 74 | FINISHING |
| 75 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 76 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cementplaster 1:6 (1 cement : 6 fine sand). |
| 77 | 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 78 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 79 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 80 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives.13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 81 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : |
| 82 | New work |
| 83 | Extra for making 12mm groove in external Wall |
| 84 | PLUMBING |
| 85 | SANITARY INSTALLATIONS |
| 86 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 87 | Providing and fixing of vitreous china white below counter oval /circular wash basin with CP brass waste assembly, wall flanges, Braided flexible pipe and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required complete in all respects.. |
| 88 | Wash basin with a 15 mm CP Brass single hole/lever basin mixer |
| 89 | Providing and fixing Stainless Steel (SS304) Convertible Ring Grating of approved make & design with grating embedding and setting ring into the floor with cement mortar, complete in all respects. |
| 90 | Round 127 mm (for drain pipe 100 mm) |
| 91 | SOIL, WASTE, VENT AND RAIN WATER PIPES & FITTINGS |
| 92 | Providing , fixing,testing and commissioning of uPVC 6kg/cm2 pipe to IS:4985:2000 complete with all required fittings, clamps, jointing etc. including cutting, fixing of pipe to wall, ceiling/sunken floor etc. for Waste pipes, bath wastes, overflow, kitchen equipment waste connections and condensate drainage including cutting of brick/RCC wall wherever required and making good the same as, complete in all respect as per specifiction and direction of Engineer In Charge. |
| 93 | 40 mm outer dia |
| 94 | 75 mm outer dia |
| 95 | Providing, fixing, jointing and testing of uPVC rain water pipes conforming to IS 4985 class III (6 kg/cm²) including injection moulded fittings like bends, tees, adopters etc. suitable for rubber ring jointing complete including jointing with rubber ring as per manufacturer recommendation and fixing to walls with clamps complete in all respects as per specifiction and direction of Engineer in Charge. |
| 96 | 110mm outer Dia |
| 97 | Providing & fixing uPVC S or P Trap of self cleansing design with or without vent arm with provision for connecting pvc inlet fitting complete including cost of cutting and making good the walls and floors wherever required, complete as per direction of Engineer in Charge. |
| 98 | 100 mm inlet and 100 mm out let |
| 99 | WATER SUPPLY |
| 100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed & External work, including cutting chases and making good the walls etc. |
| 101 | 15 mm nominal outer dia Pipes |
| 102 | 25 mm nominal outer dia Pipes |
| 103 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points etc. of approved quality conforming to IS:8931(Wall flange to be considerd in this item) |
| 104 | 15 MM Nominal Bore |
| 105 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 106 | Providing and fixing forged brass lever operated ball valve of approved make, full flow with forged brass ball (with hard chrome plated), PTFE Gland Packing and Seating, Test Pressure (Hydrostatic) :Shell : 25 kg/cm²g (350 psig)Seat : 16 kg/cm²g (225 psig)Maximum Working Temperature : 220°C complete in all respect. |
| 107 | 25mm dia |
| 108 | DRAINAGE |
| 109 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC pipes including bed concrete as per standard design |
| 110 | 150 mm dia |
| 111 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 112 | 150 mm dia |
| 113 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 114 | For pipes 100 to 250 mm diameter |
| 115 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : |
| 116 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 117 | Extra for depth beyond 45 cm of brick masonry chamber : |
| 118 | For 455x610 mm size |
| 119 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 120 | WATER PROOFING |
| 121 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: |
| 122 | With average thickness of 120 mm and minimum thicknessat khurra as 65 mm. |
| 123 | ELECTRICAL |
| 124 | WIRING, SUBMAIN, CIRCUIT AND DB |
| 125 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular\ plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 126 | Group C |
| 127 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 128 | 2x2.5 Sq.mm +1x2.5 Sq.mm |
| 129 | 2x4.0 Sq.mm +1x4.0 Sq.mm |
| 130 | 2 x 6 sq.mm + 1 x 6 sq.mm. earth wire |
| 131 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 132 | 2 Pair |
| 133 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 134 | 20 mm |
| 135 | 25 mm |
| 136 | 32 mm |
| 137 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 138 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 139 | 1 or 2 Module (75mmX75mm) |
| 140 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 141 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 142 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including onnections, painting etc. as required. |
| 143 | Supplying and fixing 3 pin 5 A celling rose on the existing junction box / wooden block inclulding connections etc. as required |
| 144 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 145 | MCCB, MCB & DB'S |
| 146 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 147 | Group C |
| 148 | MDB PANEL - 1 No. 160amp 25 kA 4P TPN MCCB with adjustable thermal and adjustable magnetic release having overcurrent and short circuit protection with extended rotary Handle complete with. 3 Nos. LED Phase Indication Lamp 2 Nos. LED Indication Lamp (Red for ON and Green OFF) BUS BAR - Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having interleaving design throughout having a maximum current density as per IEC 61439 suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING UNITS - 1. 6 Nos. 63 amp 10 kA FP MCB 2. 4 Nos. 40 amp 10 kA FP MCB . |
| 149 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator). |
| 150 | 8 way (4 + 24), Double door |
| 151 | 12 way (4 + 36), Double door |
| 152 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 153 | Single pole |
| 154 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 155 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 156 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 157 | CABLE TRAY |
| 158 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 159 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 160 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 161 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 162 | EARTHING |
| 163 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 164 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 165 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 166 | Note: Earthing strip continuity test/loop impedance test is mandatory under CPWD specifications and the test report is to be submitted & verified by the Enginner in charge. |
| 167 | MV CABLE LAYING |
| 168 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 169 | Upto 35 sq. mm |
| 170 | MV CABLE JOINTING & END TERMINATION |
| 171 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 172 | 4 X 10 sq. mm (25mm) |
| 173 | 4 X 16 sq. mm (28mm) |
| 174 | 3½ X 35 sq. mm (32mm |
| 175 | Supply of aluminium conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, at depth of 750mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 176 | 4 core 10 sq. mm |
| 177 | 4 core 16 sq. mm |
| 178 | 3.5 core 35 sq. mm (main incomer cable ) |
| 179 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 63 DELHI SCHEDULE OF RATES (E&M)-2025(CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required. |
| 180 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 181 | Supply of 450 mm sweep, exhaust fan all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 182 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep |
| 183 | Providing and fixing with efficiency (30 degree celcius temp rise) CAP 25 LTR online electric water geyser of, 50 cycles with complete fittings as per requirement. |
| 184 | SUPPLY & INSTALATION OF LIGHT FIXTURE, CEILING FAN & EXHAUST FAN |
| 185 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim |
| 186 | 8 - 10 watt |
| 187 | 12 -15 watt |
| 188 | EXTERNAL LIGHTING |
| 189 | SITC of UPLIGHTER Light |
| 190 | SITC of 2 way Up down lighter |
| 191 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass,suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, shortd. circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEMmanual, Geo- Tag of manufacturing location etc |
| 192 | FIRE ALARM SYSTEM |
| 193 | Supplying, Installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for 18MS system with open protocol Bacnet/ Modbus over IP complete as per specifications. |
| 194 | Two Loop Panel |
| 195 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 196 | Supplying. Installation, testing & commissioning of on response indicator surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 197 | Supplying, installation, testing & commissioning of fauit isolator complete with base as required. |
| 198 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 199 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 200 | Supplying. Installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required |
| 201 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 202 | Supplying, instalation, testing & commissioning of digital audio amplifier 75 Watt, 25V ims operating at 240 Volt AC Supply complete as required. |
| 203 | Supplying, Installation, testing & commissioning of Voice command keypad á zone, with microphone assembly complete as required. |
| 204 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 205 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 206 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 207 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 208 | Providing and fixing of self illuminated / auto glow \\"EXIT\\" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. |
| 209 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc:-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video: - H.265 or better, H.264H, H.264, Audio: - G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range: - WDR (120db or more)5) Digital Noise Reduction: - DNR (3D) On/Off6) Video Streaming & Frame Rates: - Triple streaming, configurable (Main stream: 2MP (1920 ×1080) @25/30 fps, Sub streams minimum: 720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card 10) Recording Management: Format SD, overwrite, storage management, video to NAS device11) Alarm Trigger: Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS, RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast13) System Capability: ONVIF, Camera shall support open-source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio: It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE18) Housing/ Enclosure: - IP67 weather proof, IK10, Metallic body19) Operating Condition: - Ambient Temperature: - (- )05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 210 | 2MP @ 25/30fps@1080P (1920×1080) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens |
| 211 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR)with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more andmust be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA\ Output for Two-way Talk with G.711U/A, G.711u,PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and outputdevices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile numberfor power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G),CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android andiOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IPaddress for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient emailaddress shall be configured to receive any combination of critical, warning, or informationalmessages or alarm notifications. When an alarm occurs, the email message includes the NVR name,time of alarm and a list of camera that is configured to record upon alarm24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity ofMinimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name,gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses,expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body,vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIRalarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error,IP Conflict and abnormal behavior of fan, cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer,logs, presets and email.31) General AI Based Search: Search Pictures by channel, time, event type, target classification (FallDetection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.32) Smart playback function: Should support smart search for the selected area in the video and smartplayback to improve the playback efficiency33) VCA (Video Content Analytic): Should support multiple video contented analytics based on cameraanalytics34) Analytics by NVR: Perimeter protection and face recognation |
| 212 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 213 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper portsupporting 802.3at PoE+ min |
| 214 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USBplayback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. |
| 215 | 55 inch or larger |
| 216 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 217 | 4TB (Terabytes) |
| 218 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 nshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance withANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required |
| 219 | 1 Run of cable |
| 220 | DATA & TELEPHONE NETWORK |
| 221 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 222 | Supplying, installation, Testing and commissioning of following capacity 8 port PoE Layer 2 Industrial Grade outdoor Network Switch having features and specifications etc. as mentioned here under: At least 8 X RJ-45 PoE/PoE+ Gigabit Ethernet Ports and additional 4 X 1G SFP Ports with non-blocking architecture by having Switching capacity of min 24Gbps and packet forwarding rate of 17Mpps or higher, console port, 16K MAC table, IPv4 and IPv6 ready, IGMP snooping v1, v2, v3, DHCP,DHCP Relay, NTP/SNTP, SNMPv1, v2 C v3, TELNET/ SSH, LACP, STP, RSTP, MSTP, ERPS. VLAN: Port based, Mac based, IP subnet based, tag based, protocol based. Ǫ- in Ǫ, L2/L3 ACL, 1588v2 Precision Time Protocol HWBased E2E Transparent clock, SNTP, TFTP, SNMP, Radius, Syslog. Dual DC Power input, IP30 rated, DIN Rail, -5° to 70° C operating temperature. Certificate: UL, CE, FCC, NEMA-TS2, IEC/MIL-STD for Shock , Vibration & Drop Certificate. OEM Should have Certificate for Industrial Cyber Security Capability IEC- 62443-4-1:2018, ISO 45001, ISO 27001 and ISO 14001 Certified or Equivelent Indian Certificate. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required |
| 223 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required |
| 224 | 2 Run of cable |
| 225 | MACHINERY |
| 226 | Hi-Wall Split AC System |
| 227 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 228 | Inverter Type - Cooling only |
| 229 | 1.0 TR with 5 Star BEE Rating |
| 230 | 1.5 TR with 5 Star BEE Rating |
| 231 | Providing and fixing of Air Curtain of following sizes having automated magnetic or mechanical sensor operation. Air curtain having ABS body sealed to resist dust. The blowers made of high quality to ensure less noise with toughness intensified high quality motor, low noise, overload protection, motor of suitable HP, 2100/2700 RPM, single phase. |
| 232 | 900mm wide Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender