Tender For Construction Of 60 Seated Hostel At Ch. Mukhtar Singh Gov. Girls Polytechnic Daurala, District Meerut.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
5.65 Lakhs
Bank guarantee accepted
Document Fee
5310
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 60 Seated Hostel At Ch. Mukhtar Singh Gov. Girls Polytechnic Daurala, District Meerut.
BOQ
| Sl. No. | Item Description |
| 1 | Civil WorkEarth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited) |
| 2 | Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift : All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)Ground Floor |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Ground Floor |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)First Floor |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bandsGround Floor |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bandsFirst Floor |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slabGround Floor |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slabFirst Floor |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bandsGround Floor |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bandsFirst Floor |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).slabGround Floor |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).slabrst Floor |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore.Ground Floor |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore.First Floor |
| 19 | Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 20 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)Ground Floor |
| 21 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)First Floor |
| 22 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) brick 115mm thickGround Floor |
| 23 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) brick 115mm thickFirst Floor |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.Ground Floora) Single leaf35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 25 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.First Floora) Single leaf35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 26 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40*40*5 mm, joints mitred and welded by angle iron 40*40*5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer,all complete as per the direction of Engineer-In-charge.Ground Floor |
| 27 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40*40*5 mm, joints mitred and welded by angle iron 40*40*5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer,all complete as per the direction of Engineer-In-charge.First Floor |
| 28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by weldingProviding & fixing of door / windows grill.Ground Floor |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by weldingProviding & fixing of door / windows grill.First Floor |
| 30 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.111 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Ground Floor |
| 31 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.111 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)First Floor |
| 32 | Fixing of M.S chaukhats in position.Ground Floor(a) Door chaukhats |
| 33 | Fixing of M.S chaukhats in position.Ground Floor(b) Window chaukhats |
| 34 | Fixing of M.S chaukhats in position.Ground Floor(c) Ventilator chaukhats |
| 35 | Fixing of M.S chaukhats in position.First Floor(a) Door chaukhats |
| 36 | Fixing of M.S chaukhats in position.First Floor(b) Window chaukhats |
| 37 | Fixing of M.S chaukhats in position.First Floor(c) Ventilator chaukhats |
| 38 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 39 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)Ground Floor |
| 40 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)First Floor |
| 41 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)Ground Floor |
| 42 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)First Floor |
| 43 | Add for plaster groove in plastered surface or moulding to R.C.C. projections.Ground Floor |
| 44 | Add for plaster groove in plastered surface or moulding to R.C.C. projections.First Floor |
| 45 | Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials, labour T & P etc for proper completion of the work.Ground Floor |
| 46 | Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials, labour T & P etc for proper completion of the work.First Floor |
| 47 | Providing and laying Vitrified tiles in floor in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to 1S:15622, of approved brand & manufacturer, in all coloursand shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarsesand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cutwith the zero chipping diamond cutter only . Laying of tiles will be donewith the notch trowel, plier, wedge, clips of required thickness, levelingsystem and rubber mallet for placing the tiles gently and easily.Ground Floor |
| 48 | Providing and laying Vitrified tiles in floor in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to 1S:15622, of approved brand & manufacturer, in all coloursand shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarsesand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cutwith the zero chipping diamond cutter only . Laying of tiles will be donewith the notch trowel, plier, wedge, clips of required thickness, levelingsystem and rubber mallet for placing the tiles gently and easily.First Floor |
| 49 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Ground Floor |
| 50 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.First Floor |
| 51 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.Ground Floor |
| 52 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.First Floor |
| 53 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete Ground Floor |
| 54 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete First Floor |
| 55 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 25 mm thick with 25 mm nominal size stone aggregate ( DSR Rate 614.2*25/40) |
| 56 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (11.26.1) 25 mm thickGround Floor |
| 57 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (11.26.1) 25 mm thickFirst Floor |
| 58 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.Ground Floor |
| 59 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.First Floor |
| 60 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels |
| 61 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.621 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactureGround Floor |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.621 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactureFirst Floor |
| 63 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufactureGround Floor |
| 64 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufactureFirst Floor |
| 65 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panesGround Floor |
| 66 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panesFirst Floor |
| 67 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thickGround Floor |
| 68 | Construction of drain of size of size 150 x 150 mm along with apron including excavation,base concrete 1:4:8 in thickness of 7.5cm of and brick work in foundation 1:4( 1 cement : 4 coarse sand) and brickwork in half brick thick in foundation 40mm thick cement concrete flooring and base 20mm thick plaster finished with neat cement. (Analysis) |
| 69 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Ground Floor |
| 70 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.First Floor |
| 71 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).Ground Floor |
| 72 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).First Floor |
| 73 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primerAs above but every coat after the first coatGround Floor |
| 74 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primerAs above but every coat after the first coatFirst Floor |
| 75 | Providing Oxidised Sliding Bolts 16 mm dia with nuts and 250 mm long.Ground Floor |
| 76 | Providing Oxidised Sliding Bolts 16 mm dia with nuts and 250 mm long.First Floor |
| 77 | Providing Oxidised Tower Bolt with 10 mm dia and screw.(i) 250 mm longGround Floor |
| 78 | Providing Oxidised Tower Bolt with 10 mm dia and screw.(i) 250 mm longFirst Floor |
| 79 | Providing Oxidised Door Handles with screws 125 mm long.Ground Floor |
| 80 | Providing Oxidised Door Handles with screws 125 mm long.First Floor |
| 81 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs.First Floor |
| 82 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.Ground Floor |
| 83 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.First Floor |
| 84 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to |S : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.71 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 85 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) |
| 86 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 87 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 88 | Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.With decorative veneering on one side and commercial veneering on other sideGround Floor & First Floor |
| 89 | Providing & Fixing special quality chromium plated brass cupboards locks with six levers including necessary screws etc. complete(best make of approved quality) of size 40mmGround Floor |
| 90 | Providing and fixing fly proof S.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beadingGround Floor |
| 91 | Providing and fixing fly proof S.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beadingFirst Floor |
| 92 | Centering and shuttering including strutting, propping etc. and removal of form work for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 93 | Centering and shuttering including strutting, propping etc. and removal of form work for : Suspended floors, roofs, landings, balconies and access platform |
| 94 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases of columns, etc. for mass concrete |
| 95 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 96 | Electrical WorkSUB-HEAD - 1 : INTERNAL WIRING & LIGHTING PROTECTION SYSTEMWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 97 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required. |
| 98 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq . mm + 1 X 1.5 sq. mm earth wire |
| 99 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq . mm + 1 X 2.5 sq. mm earth wire |
| 100 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 4 : sq. mm + 1 X 4 sq. mm earth wire |
| 101 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 102 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 X 6 sq. mm + 2X 6 sq. mm earth wire |
| 103 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 104 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 105 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 106 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch,connection etc. as required. |
| 107 | Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required |
| 108 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections etc. as required. |
| 109 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 110 | Extra for fixing the Louvers/ shutters complete with frame for exhaustfans of all sizes. |
| 111 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excludingmodular plate etc. as required. |
| 112 | SUBHEAD 2: Miscellaneous ItemsSupply of fire buckets 4 No. in each set duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. Fire buckets shall be painted red from outside and white from inside with additional handle at the bottom and suitable for outdoor installation. |
| 113 | Supply of tool kit with 1 pair 11 KV rubber hand gloves as directed by Engineer Incharge. |
| 114 | Supplying & fixing standard shock treatment charts in English & Hindi duly framed and covered with glass as directed by Engineer Incharge. |
| 115 | Providing Safety mat made of elastomeric polymers Material (Class B) 1.2 M wide with thickness 2.5 mm to withstand 12KV dielectric strength AS PER relevant IS Code |
| 116 | SUB-HEAD-3 : TELEPHONE & DATA SYSTEMSupplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:2 Pair (4 core) |
| 117 | Supplying and fixing following size/ modules, GI box alongwith modularbase & cover plate for modular switches in recess etc as required4 Module (125mmX75mm) |
| 118 | Supplying and fixing following size/ modules, GI box alongwith modularbase & cover plate for modular switches in recess etc as required6 Module (200mmX75mm) |
| 119 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredTelephone socket outlet |
| 120 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredTV socket outlet |
| 121 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredRJ-45 Data Socket outlet |
| 122 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required |
| 123 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable |
| 124 | SUB-HEAD-4 : LIGHT FIXTURES:LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).0 Watt |
| 125 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim 18 watt |
| 126 | Supply and fixing of LED Tube Light with heavy duty Metal Box type Mirror Light fitting 10 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect |
| 127 | Supply and fixing of LED 10W Bulb with Holder Complète in all respect |
| 128 | Brush Less Direct Current (BLDC) Fan with RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 129 | Supply and fixing of Ex-Fan 200mm Complète in all respect |
| 130 | SUBHEAD- 5: DISTRIBUTION BOARDSupplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 131 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 132 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioningetc. as required40 amps 4P MCB |
| 133 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioningetc. as required63 amps 4P MCB |
| 134 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 6-32Amp C Curve |
| 135 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 136 | SUB-HEAD-6 : EARTHING SYSTEMEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 137 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 138 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 139 | SUB-HEAD-7 : LIGHTING ARREASTERProviding and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 140 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. |
| 141 | Jointing copper/G.I. tape (with another copper/GI tape, base of the finial or any other metallic object) by riveting/ nut bolting/ sweating and soldering etc as required. |
| 142 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 143 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 144 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 145 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 146 | SUB-HEAD-8 : CABLESSupply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 sq. mm 4 core |
| 147 | Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.150 sq. mm 3-1/2 core |
| 148 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kv grade as required.16 sq. mm 4 core |
| 149 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kv grade as required.150 sq. mm 3-1/2 core |
| 150 | SUB-HEAD-9 : CABLE TRAYSupplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray With perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 151 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray With perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 152 | SUB-HEAD-10 : L.T. PANELSupply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.2mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this sectionThe minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmMain L.T. Panel Incoming :One (1) No 315A 4 pole MCCBMetering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-315A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No.315 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100Amps TPN - 3 NosOR outgoing as per site requirment(as/drg.) |
| 153 | INTERNAL PLUMBING WORKSSANITATION WORKProviding and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 154 | Providing and fixing white glazed earthen wate (European type) W.C. Pan 580mm dia,(10 ltr) PVC Flushing Cistern complete with G.I. Pull chain,M.S.Bracket of Engineer-in-Charge.(Standered size) |
| 155 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 156 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia |
| 157 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 40 mm dia |
| 158 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 159 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 160 | Providing and fixing PTMT Bottle Trap for Wash basin and sinkBottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms |
| 161 | Providing and fixing Toilet paper holdera) C.P. brass |
| 162 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 163 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge.a) 15mm dia nominal dia. |
| 164 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 165 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 166 | CP Brass fittingsProviding and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore |
| 167 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 168 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore |
| 169 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 170 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet150 mm diameter |
| 171 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15mm nominal bore |
| 172 | RAIN WATER SUPPLYProviding and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm |
| 173 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)100 /90 mm dia |
| 174 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm |
| 175 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Bend 87.5 degree110 mm Bend |
| 176 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.110 mm Shoe |
| 177 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 178 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 179 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 180 | INTERNAL WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes |
| 181 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 20 mm nominal outer dia Pipes |
| 182 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal outer dia Pipes |
| 183 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore |
| 184 | Providing and fixing brass stop cock of approved quality.b) 20 mm nominal bore |
| 185 | NON SCHEDULED ITEMSSANITARY INSTALLATIONS & C.P FITTINGSProviding and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.a) 110mm dia P.V.C. pipe |
| 186 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.b) 90mm dia P.V.C. pipe |
| 187 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince)P-Trap type Floor Trap 110 x 90 mm |
| 188 | Providing and fixing terminal guard.a) 110mm |
| 189 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.110mm bend |
| 190 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.90 mm bend |
| 191 | Coupler110mm |
| 192 | 90x90x90 mm |
| 193 | Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore |
| 194 | Providing and fixing clean out plug 110 mm dia. |
| 195 | Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 160mm dia Under floor |
| 196 | Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawing complete. |
| 197 | FIRE FIGHTINGSupplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm |
| 198 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm |
| 199 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm |
| 200 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 201 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.100 mm |
| 202 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.80 mm |
| 203 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.25 mm |
| 204 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 5000.00 Ltr. |
| 205 | Supplying & fixing single headed internal yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal |
| 206 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe |
| 207 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m |
| 208 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 209 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal |
| 210 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal |
| 211 | Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520.(b) Suitable HP Squirrel cage indution motor, TEFC type synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, confirming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads.450 lpm at 35 m Head |
| 212 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 213 | Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32mm nominal bore. |
| 214 | PART - B, As per PWD & MARKET RATESSurface dressing of road with Painting between using 2.25 kg. of bitumen per sq.mt with 1.65 cum of stone chipping ,13.2 mm nominal size/100 sq.mt of road surface including corolidation .(Although this job the fore will be given to civil contractor /Required Tank and pump house as per direction of Fire Department) |
| 215 | Supplying Installation testing & Commissioning of 25 mm Ball valve PN -1 gunmental as per IS:778 including necessary accessories and connections. Make : Standard Make |
| 216 | Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. Make : Standard Make |
| 217 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of :a) One 63 amp. TP+NL M.C.C.B with rotary handle of beacking capacity 35 KA.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps. Make : Standard Make |
| 218 | Supplying and laying of Insulated PVC sheathed ,Steel Aromed ,Copper Aluminum Conductor, 1100V grade Powder Cable . The cable shall be laid in tray /in trenches/on wall /floor etc. As required (Approx quantities only). Make : RR Kabel / Policab / Finolex2 crore x 1.5 sq.mm Cu Cable |
| 219 | Supplying and laying of Insulated PVC sheathed ,Steel Aromed ,Copper Aluminum Conductor, 1100V grade Powder Cable . The cable shall be laid in tray /in trenches/on wall /floor etc. As required (Approx quantities only). Make : RR Kabel / Policab / Finolex3.5 crore x 25 sq.mm AL Cable |
| 220 | Supplying and fixing of Self Glow Exit signage for stairs and exits size 100 x 300. |
| 221 | Fire man axe. Make: Firetol / Swastik / Innovative |
| 222 | Supply & fixing of fire extinguishers, CO2 type 6.50 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 223 | Supply & fixing of fire extinguishers, ABC type 6.00 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 224 | CCTV WorkSupply , Installation , Testing and commissioning of CAT 6 UTP cable |
| 225 | Supply, Installation, Testing & Commissioning of CAT 6 UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 1 Mtr for rack side switch to jack panel connectivity. |
| 226 | SITC Of 12 U wall Mountable open Rack with front glass door and rear ms door including with 3 socket 6/16 Amp PDU, mounting hardware & Fan Tray. |
| 227 | Supply, Installation, Testing & Commissioning of 12 floor mount rack with fans, 2 cable managers stationary shelf, 2 Nos. of hardware pkts |
| 228 | Supply, installation, testing and commissioning of2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 229 | Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc :-2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens |
| 230 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2) NVR should support H.265 or better, H.264,MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring,network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEMCloud for remote monitoring without any public IPneed.display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 231 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 8TB |
| 232 | Supply, Installation, Testing and Commissioning of Full HD 55\\" LED Professional Display Panel. Approved Makes: Panasonic / LG/ Sony/ Samsung |
| 233 | Supply, Installation, Testing & Commissioning of L2 managed industrial PoE switch with 24 10/100/1000M RJ45 ports |
| 234 | SEPTIC TANK & SOAK PITEarth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m depth |
| 235 | Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m to 3.0m. depth |
| 236 | Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 3.0m to 4.5m. depth |
| 237 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 238 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 239 | Reinforcement cement concrete work in RCC culvert slab with 1:2:4 (1 cement : 2 coarse sand and 4 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 240 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 241 | Centring and shuttering including struting, proping etc and removal of form for slab. |
| 242 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) |
| 243 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 244 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 245 | Providing & fixing 75mm dia vent pipes. |
| 246 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 247 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter |
| 248 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -2.5- Circular shape 450mm internal diameter |
| 249 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks |
| 250 | Tube WellBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge,upto 90 metre depth below ground level.Rocky strata including Boulders 300 MM Dia |
| 251 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.Rocky strata including Boulders 300 MM Dia |
| 252 | Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as per direction ofEngineer -in-charge.150 MM Nominal size dia |
| 253 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc. allcomplete, for all depths, as per direction of Engineer-in-charge. |
| 254 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 255 | Development of tube well in accordance with 1S : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories efc., all as per requirement and direction of Engineer-in-charge. |
| 256 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia |
| 257 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp |
| 258 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per 1S:2800 (part I). |
| 259 | Supply of 2 HP KSB make submersible pump set model BPD 302/4+6UMA1/G 150/6/22 (SD) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric motor operating of 415 volts suitable for 3 phase 50 cycle A.C. Supply of following duty condition 2 HP 2 stage pipe. A-Discharge of water in LPM 860 Approx size of discharge outlet in 40mm.B-Total Head of pump set 45MAS PER MARKET RATE |
| 260 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber ins ertions etc. (the tail pieces if required will be paid separately) 100 mm diameter Class | |
| 261 | Wire 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 262 | C.C. ROADEarth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited) |
| 263 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil. |
| 264 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 265 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 266 | Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 267 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete prepared with batch mixing machine |
| 268 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. |
| 269 | Supply and Laying for separation membrane of impermeable plastic sheeting 125 micron thick. |
| 270 | RAIN WATER HARVESTINGRECHARGE PITSEarth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.In all kind of soil upto 1.5m depth |
| 271 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.In all kind of soil upto 1.5m to 3.0m. depth |
| 272 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.In all kind of soil upto 3.0m to 4.5m. depth |
| 273 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.In all kind of soil upto 4.5 m to 6.0m. depth |
| 274 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 275 | Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 276 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 277 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 278 | Centing and shuttering including strutting, propping etc. and removal of form for slab. |
| 279 | 1:4 (1 cement : 4 Coarse sand) |
| 280 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:With 20x20mm square bar |
| 281 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter |
| 282 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.Drilling of 300mm dia bore hole manually. |
| 283 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia |
| 284 | Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 285 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 286 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 287 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. |
| 288 | DESILTING CHAMBEREarth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.In all kind of soil upto 1.5m depth |
| 289 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.In all kind of soil upto 1.5m to 3.0m. depth |
| 290 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 291 | Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 292 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 293 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 294 | 15mm cement plaster on rough side of single or half brick wall mix 1:4 (1 cement : 4 Coarse sand) |
| 295 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:With 20x20mm square bar |
| 296 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter |
| 297 | DRAINAGE NETWORKExcavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 298 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 299 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia. |
| 300 | NON D.S.R. ITEMSa) Inside M.H. chamber size 60x60 cm & 90 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500 mm dia cover without frame (medium duty) |
| 301 | STORM WATER DRAINEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. |
| 302 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 303 | Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 304 | 20 mm cement plaster of mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement |
| 305 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 306 | EXTERNAL PLUMBINGCOST OF SEWERAGE/RWH Line WORKSExcavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 307 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m to 3.00 m depthPipes 80 mm to 300 mm diameter |
| 308 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 309 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth 1.5 to 3.00 meter |
| 310 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 311 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250 mm. dia. RCC Pipes |
| 312 | Providing and laying cement concrete 1:5:10 (1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia. |
| 313 | Providing and laying cement concrete 1:5:10 (1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design250 mm. dia. |
| 314 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line |
| 315 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 316 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 317 | COST OF EXTERNAL WATER SUPPLY WORKSProviding & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)b) 50mm nominal bore. |
| 318 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)c) 32mm nominal bore. |
| 319 | Supplying and fixing of specials for pressure pipe. (10% of Item No. 12) |
| 320 | Supplying and fixing of specials for pressure pipe. (10% of Item No. 13) |
| 321 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.a) 65mm nominal bore. |
| 322 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.b) 50mm nominal bore. |
| 323 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.c) 32mm nominal bore. |
| 324 | Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 325 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm dia nominal bore |
| 326 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm dia nominal bore |
| 327 | External Electrification WorkSub Head 1 : EarthingEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 328 | Earthing with Copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 329 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meterbelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
| 330 | Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required. |
| 331 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. |
| 332 | EXTERNAL LIGHT FEEDER PILLARSupply installing testing & commissioning of out door type street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below.Incoming63 Amp. 10 KA FP MCCB 1 No.Suitable contractor and timer for down & dusk100 Amp. TPN Alu. Bus barOutgoing25 Amp. 10KA SP MCB 6 No. |
| 333 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. |
| 334 | Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 90 watt. Confirming to IP 66 and above protection complete in all respect. |
| 335 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 336 | High Mast LightSupply and fixing of 12.5 mtr High mast Pole of approved make with rising system, hot dip Galvanized inside & outside , having pole sheet thickness 3mm, top minimum100mm, bottom dia minimum 310mm, base plate 25mm thick, suitable for wind velocity as per IS 875 part 3. & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes,0.75 HP Power tool motor, 3 point suspension system with steel wire rope 6mm dia , double drum winch Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers , anchor plates etc Complete in all respect. as per direction and satisfaction to the Engineer-in-charge. |
| 337 | Supply and fixing of factory wired integeral LED flood light luminaires die cast aluminium housing built with driver set suitable for 170 to 200 Watt. Confirming to IP 66 protection Complete in all respect. CAT. AAA |
| 338 | supply and fixing of 40 amp TPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors , HRC fuse , isolating switch , metering instrument and instrument box with CTs etc.complete in all respect. |
| 339 | UNDER GROUND CABLES'Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 10 sq. mm |
| 340 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 16 sq. mm |
| 341 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 25 sq. mm |
| 342 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 343 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 344 | INTERLOCKINGEarth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited) |
| 345 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 346 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 347 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light traffic parkingetc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50 mmthick compacted bed of sand, compacting and proper embedding/layingof inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cuttingof paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approvedcolour design and pattern |
| 348 | BOUNDARY WALLEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as d |
| 349 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nomi |
| 350 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the |
| 351 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natu |
| 352 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of |
| 353 | Brick work with common burnt clay (non modular) bricks of class designation 15in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 354 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 355 | Steel reinforcement Thermo mechanically Treated bars of grade Fe 500 or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete |
| 356 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 357 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 358 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 359 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 360 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 361 | Foundations, footings, bases of columns, etc. for mass concrete |
| 362 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 363 | GATEEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil |
| 364 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 365 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 366 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Beams |
| 367 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 368 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 369 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 370 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm). |
| 371 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 372 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 373 | Centering and shuttering including strutting, propping etc. and removal of form work for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 374 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases of columns, etc. for mass concrete |
| 375 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, Pillars, Piers, Abutments, Posts and Struts Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender