Educational and Research Institute Local Bodies Closing in 14 days TDR #58551291

Tender For Purchase Of Equipment , Mass Flow Controller , Parameter : Specification Gas Mixing Capability : Simultaneous Mixing Of 2-3 Gases With Computer Control. Mfc Type : Multi-Gas Selectable Mass Flow Controllers. Calibrated Gases : Air, N₂O, Ch₄, Co

Issued by Local Bodies · Coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Dec 2026
14 days left
EMD
6000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Purchase Of Equipment , Mass Flow Controller , Parameter : Specification Gas Mixing Capability : Simultaneous Mixing Of 2-3 Gases With Computer Control. Mfc Type : Multi-Gas Selectable Mass Flow Controllers. Calibrated Gases : Air, N₂O, Ch₄, Co₂, Co, C₂H₆, O₂, Deuterium, Sf₆, H₂S, No, Propylene, Cos, Silane, Nh₃, Iso-Butene, Nf₃, Dimethyl Ether, Nitrogen Display : Integrated Lcd Display With Touchpad. Parameters Displayed : Mass Flow, Volumetric Flow, Pressure, Temperature, Set Point And Valve Opening (%) Simultaneously. Resolution : Two To Three Decimal Places With Adjustable Decimal Option. Local Control : Individual Led/Lcd Display With Flow Control Switch. Power Supply : Stand-Alone Power Adapter. Gas Mixing Feature : User-Defined Gas Compositions Without Recalibration. Communication Interface : Rs-232 And Rs-485. Software Functions : Automatic Configuration, Session Saving, Data Logging, Graphing, Scripting, Alarms, Multi-Device Support. Maximum Operating Pressure : 160 Psia. Downstream Pressure : 0.25 Kg/Cm² (G) And Vacuum. Proof Pressure : 175 Psia Operating Temperature : -10°C To +60°C. Humidity Range : 0-95% Rh, Non-Condensing. Wetted Material : Ss302 Preferred. Seal Material : Viton Preferred. Accuracy : ±0.7% Or (0.6% Reading + 0.1% Full Scale). Repeatability : ±(0.1% Reading + 0.02% Full Scale). Pressure Sensitivity : 0.01% Full Scale/Psi. Construction : Rigid Metallic Construction. Analog Input/Output : 0-5 Vdc Or 4-20 Ma. Digital Communication : Rs-232 Or Rs-485 Circuit Protection : Required. Power Requirement : 230 V Ac, 50 Hz. Gas Connection : ¼ Inch Swagelok Compression Fittings. Auto-Tune Function : Automatic Pid Optimization For Pressure/Plumbing Changes. Flow Ramp Programming : Through Built-In Lcd Display And Keypad Re-Calibration Facility : Oem-Owned Nist Accredited Calibration And Service Center In India. Warm-Up Time : 1 Second. Response Time : 10 Ms Operating Range : 0.01%-100% Full Scale. Turndown Ratio : 10000:1. Electrical Connection : Db9 Pin. Accessories : Communication Cables, Interfaces, Power Supplies, Converters. Documentation : Service Manual, Operation Manual, Circuit Diagram. Additional Accessories : Software, Fittings, Communication Cables And Power Supply. Computer Interface : Rs-232 Or Usb. Gas Mixing Capability : Automatic Mixing Of Up To 3 Gases. Operation : Instant Gas Mixture Generation With Mouse Click. User Interface : Intuitive Gui. Flow Implementation : Automatic Based On Concentration And Pressure. Error Handling : Out-Of-Range Selection Warning. Data Storage : Store And Retrieve Settings. Device Capacity : Configure Up To Six Mass Flow Controllers. Setup Wizard : Required. Mixture Library : Save And Load Predefined Mixtures. Data Logging : Required. Mixture Adjustment : Slider-Based Adjustment Of Total And Individual Gas Percentages.

BOQ

Name of Work:- Purchase of Equipment
Sl. No. Item Description
1Mass Flow Controller
2Parameter : SpecificationGas Mixing Capability : Simultaneous mixing of 2–3 gases with computer control. MFC Type : Multi-gas selectable Mass Flow Controllers.Calibrated Gases : Air, N₂O, CH₄, CO₂, CO, C₂H₆, O₂, Deuterium, SF₆, H₂S, NO, Propylene, COS, Silane, NH₃, Iso-Butene, NF₃, Dimethyl Ether, NitrogenDisplay : Integrated LCD display with touchpad. Parameters Displayed : Mass Flow, Volumetric Flow, Pressure, Temperature, Set Point and Valve Opening (%) simultaneously. Resolution : Two to three decimal places with adjustable decimal option. Local Control : Individual LED/LCD display with flow control switch. Power Supply : Stand-alone power adapter. Gas Mixing Feature : User-defined gas compositions without recalibration. Communication Interface : RS-232 and RS-485. Software Functions : Automatic configuration, session saving, data logging, graphing, scripting, alarms, multi-device support. Maximum Operating Pressure : 160 PSIA. Downstream Pressure : 0.25 kg/cm² (G) and vacuum. Proof Pressure : 175 PSIAOperating Temperature : -10°C to +60°C. Humidity Range : 0–95% RH, non-condensing. Wetted Material : SS302 preferred. Seal Material : Viton preferred. Accuracy : ±0.7% or (0.6% Reading + 0.1% Full Scale). Repeatability : ±(0.1% Reading + 0.02% Full Scale). Pressure Sensitivity : 0.01% Full Scale/PSI. Construction : Rigid metallic construction. Analog Input/Output : 0–5 VDC or 4–20 mA. Digital Communication : RS-232 or RS-485Circuit Protection : Required. Power Requirement : 230 V AC, 50 Hz. Gas Connection : ¼ inch Swagelok compression fittings. Auto-Tune Function : Automatic PID optimization for pressure/plumbing changes. Flow Ramp Programming : Through built-in LCD display and keypadRe-Calibration Facility : OEM-owned NIST accredited calibration and service center in India. Warm-Up Time : < 1 second. Response Time : < 10 msOperating Range : 0.01%–100% Full Scale. Turndown Ratio : 10000:1. Electrical Connection : DB9 Pin. Accessories : Communication cables, interfaces, power supplies, converters. Documentation : Service manual, operation manual, circuit diagram. Additional Accessories : Software, fittings, communication cables and power supply. Computer Interface : RS-232 or USB. Gas Mixing Capability : Automatic mixing of up to 3 gases. Operation : Instant gas mixture generation with mouse click. User Interface : Intuitive GUI. Flow Implementation : Automatic based on concentration and pressure. Error Handling : Out-of-range selection warning. Data Storage : Store and retrieve settings. Device Capacity : Configure up to six Mass Flow Controllers. Setup Wizard : Required. Mixture Library : Save and load predefined mixtures. Data Logging : Required. Mixture Adjustment : Slider-based adjustment of total and individual gas percentages. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58551291
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 01-12-2026
Authority
Authority Name Department Of Higher Education
Work Description Tender For Purchase Of Equipment , Mass Flow Controller , Parameter : Specification Gas Mixing Capability : Simultaneous Mixing Of 2-3 Gases With Computer Control. Mfc Type : Multi-Gas Selectable Mass Flow Controllers. Calibrated Gases : Air, N₂O, Ch₄, Co₂, Co, C₂H₆, O₂, Deuterium, Sf₆, H₂S, No, Propylene, Cos, Silane, Nh₃, Iso-Butene, Nf₃, Dimethyl Ether, Nitrogen Display : Integrated Lcd Display With Touchpad. Parameters Displayed : Mass Flow, Volumetric Flow, Pressure, Temperature, Set Point And Valve Opening (%) Simultaneously. Resolution : Two To Three Decimal Places With Adjustable Decimal Option. Local Control : Individual Led/Lcd Display With Flow Control Switch. Power Supply : Stand-Alone Power Adapter. Gas Mixing Feature : User-Defined Gas Compositions Without Recalibration. Communication Interface : Rs-232 And Rs-485. Software Functions : Automatic Configuration, Session Saving, Data Logging, Graphing, Scripting, Alarms, Multi-Device Support. Maximum Operating Pressure : 160 Psia. Downstream Pressure : 0.25 Kg/Cm² (G) And Vacuum. Proof Pressure : 175 Psia Operating Temperature : -10°C To +60°C. Humidity Range : 0-95% Rh, Non-Condensing. Wetted Material : Ss302 Preferred. Seal Material : Viton Preferred. Accuracy : ±0.7% Or (0.6% Reading + 0.1% Full Scale). Repeatability : ±(0.1% Reading + 0.02% Full Scale). Pressure Sensitivity : 0.01% Full Scale/Psi. Construction : Rigid Metallic Construction. Analog Input/Output : 0-5 Vdc Or 4-20 Ma. Digital Communication : Rs-232 Or Rs-485 Circuit Protection : Required. Power Requirement : 230 V Ac, 50 Hz. Gas Connection : ¼ Inch Swagelok Compression Fittings. Auto-Tune Function : Automatic Pid Optimization For Pressure/Plumbing Changes. Flow Ramp Programming : Through Built-In Lcd Display And Keypad Re-Calibration Facility : Oem-Owned Nist Accredited Calibration And Service Center In India. Warm-Up Time : 1 Second. Response Time : 10 Ms Operating Range : 0.01%-100% Full Scale. Turndown Ratio : 10000:1. Electrical Connection : Db9 Pin. Accessories : Communication Cables, Interfaces, Power Supplies, Converters. Documentation : Service Manual, Operation Manual, Circuit Diagram. Additional Accessories : Software, Fittings, Communication Cables And Power Supply. Computer Interface : Rs-232 Or Usb. Gas Mixing Capability : Automatic Mixing Of Up To 3 Gases. Operation : Instant Gas Mixture Generation With Mouse Click. User Interface : Intuitive Gui. Flow Implementation : Automatic Based On Concentration And Pressure. Error Handling : Out-Of-Range Selection Warning. Data Storage : Store And Retrieve Settings. Device Capacity : Configure Up To Six Mass Flow Controllers. Setup Wizard : Required. Mixture Library : Save And Load Predefined Mixtures. Data Logging : Required. Mixture Adjustment : Slider-Based Adjustment Of Total And Individual Gas Percentages.
Basic Detail
Tender No BU/RUSA2.0/2026/R23/Nano/74934
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 16 Nov 2026
Submission Date 01 Dec 2026
Open Date 02 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 6000
Exemption Available
Document List
86213799-8272-43b8-9304-b765e191c087.html
BOQ_872548.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

86213799-8272-43b8-9304-b765e191c087.html

xls

BOQ_872548.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender