Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58550916

Tender For Provision Of Acs To Computerised Class Room And Conference Room (Bldg No P -392) At Celabs At Naval Base, Kochi And Provn Of Drain Water Outlets For Acs Of Bldg No P 437(G+3) Of Inas 336 Garuda At Naval Base Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Dec 2026
20 days left
EMD
24540
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Acs To Computerised Class Room And Conference Room (Bldg No P -392) At Celabs At Naval Base, Kochi And Provn Of Drain Water Outlets For Acs Of Bldg No P 437(G+3) Of Inas 336 Garuda At Naval Base Kochi

BOQ

Name of Work:- PROVISION OF ACS TO COMPUTERISED CLASS ROOM AND CONFERENCE ROOM (BLDG NO P -392) AT CELABS AT NAVAL BASE, KOCHI AND PROVN OF DRAIN WATER OUTLETS FOR ACS OF BLDG NO P 437(G+3) OF INAS 336 GARUDA AT NAVAL BASE KOCHI
Sl. No. Item Description
1Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity (Inverter type) with HD filter complete with cordless remote control, 5 star labelled, latest model energy efficient model eco friendly, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & Gold pin coating and 100% copper cooling coil with ocean black protection complete all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance as per site requirement, and first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and directed
2Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity (Inverter type) with HD filter complete with cordless remote control, 5 star labelled, latest model energy efficient model eco friendly, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper and 100% copper cooling coil complete with all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance as per site requirement, and first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and directed
3Supply, installation, testing and commissioning of tower air conditioning unit 4 TR capacity with filter complete with cordless remote control, latest model energy efficient model eco friendly, 12000 Kcal / Hr, 50 Hz, 415 volts, air cooled condenser with 100% copper & anticorrosion coating and 100% copper cooling coil with ocean black protection completewith all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance as per site requirement, including suitable industrial plug and socket unit and first charging of refrigerant gas including cordless remote, complete all as specified and directed
4Note : - (i) All outdoor units must be installed/ placed in service friendly location /as per the direction of Engr-in-charge. The bidder must visit the site before bidding to ensure feasibility of location to ensure requirement of refrigerant pipes/electrical fittings(ii) The bidder should install the AC by the auth rep of OEM and provide test certificate .(iii) The ACs should have warranty for 10 years on compressor, 05 yrs warranty onPCBs, fan motor (indoor& outdoor) & swing motor and 01 year comprehenssive warranty. In this condition the contractor has to submit the warranty certificate by the OEM before claiming the RAR.(iv) Core cutting and making good is included in the unit rate.(v) Removal and refixing of wall panelling if any is included in the unit rate.
5Supply and fix MCB protected socket 4 module 20A, metal base, PVC plate (white) color cover plate suitable for upto 2.0 Ton AC with 16A 3 pin top, 20 A SP MCB 16A Socket duly concealed on the surface/wall including making all electrical connection complete all as specified and directed
6Material and labour for submain wiring alongwith earthwire of FRLS , PVC insulated copper conductor, single core cable in pvc conduit surface type of size 4 x 6 sqmm + 1 x 6 sqmm earth wire complete all as specified and directed.
7Material and labour for submain wiring alongwith earthwire of FRLS , PVC insulated copper conductor, single core cable in pvc conduit surface type of size 2 x 4 sqmm + 1 x 4 sqmm earth wire complete all as specified and directed.
8Supply and fix MCB SP upto 32 Amps capacity, 240 volt, 10 KA, 'C' curve complete all as specified and directed.
9Supply and fix MCB TPN from 40 to 63 Amps capacity, 415 volt, 10 KA, 'C' curve complete all as specified and directed.
10Supply and fix MCB TPN DB 4 way double door made of sheet steel phosphatised, powder painted with NUTRAL with suitable busbar capacity, neutral link, earth bar and Din rail , 415 Volts IP-54-IK09 protection grade complete all as specified and as directed.
11Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.5 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber, RCC Cover with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified
12Supply and fix of 4 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5 Sqmm complete all as specified and as directed
13Supply & fixing of copper tube of size both 5/8\\" & 1/4\\" from indoor unit to outdoor unit including nitrile rubber insulation for refrigerant line suitable for 2 ton AC all as specified and as directed.
14Supply & fixing of copper tube of size both 1/2\\" & 1/4\\" from indoor unit to outdoor unit including nitrile rubber insulation for refrigerant line suitable for 1.5 ton AC all as specified and directed.
15Supply and fix 410 NX AC voltage stabilizer suitable for 1.5 ton inverter air conditioners complete all as specified and directed
16Supply and fix VG 500 voltage stabilizer suitable for 2.0 ton inverter air conditioners complete all as specified and directed
17Supply and fixing of UPVC 20 mm dia pipe complete including accessories such as bends, tees, elbow all as specified and directed as per site requirement
18Supply, installation of UPVC pipe, 20 mm dia complete alongwith accessories such as bends, tees, sockets and nipples suitable for drain out of split air conditioning unit 1.5/2.0 TR capacity (Inverter type/Non inverter type). Drain pipes to reach nearest drain complete all as specified and directed as per site requirement.Note :- (i) The work has to be executed from GF to third floor of bldg. The Contractor has to arrange necessary tools and plants alongwith safety precausions for fixing necessary drain pipes.(ii) Necessary safety tools and scafoldiing included in the unit rate method Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58550916
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 08-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Acs To Computerised Class Room And Conference Room (Bldg No P -392) At Celabs At Naval Base, Kochi And Provn Of Drain Water Outlets For Acs Of Bldg No P 437(G+3) Of Inas 336 Garuda At Naval Base Kochi
Basic Detail
Tender No 8731/E8
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 16 Nov 2026
Submission Date 08 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 24540
Exemption Available
Document List
7fbaf4ed-d66d-4f8d-a1aa-bb62d7b85907.html
BOQ_896334.xls
COMMONPAGES8731.pdf
PS8710.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

7fbaf4ed-d66d-4f8d-a1aa-bb62d7b85907.html

xls

BOQ_896334.xls

pdf

COMMONPAGES8731.pdf

pdf

PS8710.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender