Tender For Repair / Maintenance Of Lt Ug Cable, Feeder Pillar Boxes, Service Connections And Other Allied Works Of Hasting Area And Afcb Under Ge (C) Kolkata
Tender Value
28 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Lt Ug Cable, Feeder Pillar Boxes, Service Connections And Other Allied Works Of Hasting Area And Afcb Under Ge (C) Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA NAME OF WORK :REPAIR / MAINT OF LT UG CABLE, FEEDER PILLAR BOXES, SERVICE CONNECTIONS AND OTHER ALLIED WORKS OF HASTING AREA AND AFCB UNDER GE (C) KOLKATA Contract No: GE (C )/KOL/ OF 2026-27 (8986) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil for laying of UG cable complete all as specified and directed.Note : 1. The cost of taking down and refixing of any type of cheqered tiles, interlocking tiles etc and deemed to be included in quoted rate. 2. The PCC work shall be measured & paid for separately uner respective item |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed. |
| 4 | Removing excavated material ( soils of any type) not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 5 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed.Note:- Thickness after punning down shall be measured for payment. |
| 6 | Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed. |
| 7 | Laying only in trenches Old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed. |
| 8 | Taking out the old unserviceable LT underground cable of any size & any description 1100 volts grade, XLPE insulated from trenches/wall/floor/road/ culverts or pole etc including brick cover complete all as specified and directed.Note : Excavation and earth work, duct work,etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ. |
| 9 | M & L for Relaying of retrieved cable of any size & any description 1100 volts grade, XLPE insulated and PVC sheathed , armoured heavey duty with multistrand aluminium conductors in trench/wall/floor/road/culverts or pole etc complete all as specified and directed.Note : Excavation and earth work, duct work,etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ. |
| 10 | Supply , laying , jointing, testing and commissioning of size 16 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe Including all neccessray fittings like gland,lugs,& thimble etc complete all as specified and directed.Note : Excavation, earth work, shall be measured and paid separately. |
| 11 | All as per item No 9.00 above but of size 25 Sqmm 4 core complete all as specified and directed. |
| 12 | All as per item No 9.00 above but of size 50 Sqmm 3.5 core complete all as specified and directed. |
| 13 | All as per item No 9.00 above but of size 70 Sqmm 3.5 core complete all as specified and directed. |
| 14 | All as per item No 9.00 above but of size 95 Sqmm 3.5 core complete all as specified and directed. |
| 15 | All as per item No 9.00 above but of size 120 Sqmm 3.5 core complete all as specified and directed. |
| 16 | All as per item No 9.00 above but of size 185 Sqmm 3.5 core complete all as specified and directed. |
| 17 | M & L for disconnecting existing underground cable including carry out megger testing of LT cable and locating the fault and cutting the faulty damaged portion of cable, S & F new heat shrinkable straight through jointing kit of cable size 10 to 50 Sqmm, 3.5/4 Core, including excavation, returning, relaying & refilling all connected materials complete all as specified and directed.Note:-Necessary excavation , sand cushioning ,cable cover as bricks etc beyond 8 mtr shall be measured and paid separately. |
| 18 | All as per item No. 16.00 mentioned here-in-before but 70 sqmm to 95 sqmm 3.5/4.0 core |
| 19 | All as per item No. 16.00 mentioned here-in-before but 120 sqmm to 300 sqmm 3.5/4.0 core |
| 20 | M&L for cutting the faulty/ damaged end portion of the U/G cables of any type and making good end termination with and including suitable size of aluminium thimble duly crimped with crimping tool and refixing its own position ,including Insulation tape, nut ,bolts etc as required for the following sizes:-Note :- Necessary excavation, earth work shall be measured and paid separately if required. |
| 21 | cable upto 70 Sqmm |
| 22 | 95 Sqmm to 120 Sqmm |
| 23 | 150 Sqmm to 240 sqmm |
| 24 | Labour only for disconnecting, taking out underground faulty cable from Panel/ Pole/ transformer / junction box / DBs or any position of length not more than 5 m in loop including excavation and earthwork, taking out bricks and relaying the old cable in loop and making reconnection at existing location after dressing of cable leads, including relaying old bricks and returning, filling in soil etc complete all as specified and as directed |
| 25 | Disconnecting the existing connection for both ends of the faulty cable, testing the faulty LT underground cable with the help of cable fault locating machine at site, finding out the location of fault in LT underground cable of any size any type by using cable fault locator machine complete all as specified and as directed including removal of moisture content from cable complete all as specified and directed.Note :- (i) The cable fault locator machine, necessary T&P, main power for locating of fault shall be arranged by the contractor and quoted rate deemed to be included.(ii) Necessary excavation, earthwork joint etc measured and paid separately under respective item of Sch 'A' / BOQ. |
| 26 | Supply, installation, testing and commissioning of LT Panel, LT (415 Volt, 50 Hz , 3-phase, 4 wire supply) of size not less than (1.5 X 1.2 X 0.5m) CPRI approved/tested , factory assembled, out door type conforming to IP 54, weather and vermine proof Made out of 2.00 mm thick CRCA sheet with front hinged, single door opening, rubber lining, locking arrangement, painted internally and externally with powder coating of grey shade (RAL-7032) as per seven tank process complete mounted comprising of the following :- (a) Bus bas chamber having 4 nos of air insulated Aluminum strip bus bars of rating not less the 1.5 times the rated capacity of the incomer MCCB, Bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminum four pole(bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming :- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade, 400 amps, 36 KA, Adjustable thermal and Adjustable magnetic release (Ics=100%Icu).- 01 No.(ii) Digital Voltmeter of suitable capacity, of suitable0-500V with selector switch 96 mm X 96 mm square flush mounted, with three way rotary selector switch-1 No.(iii) Digital Ammeter of suitable capacity, size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) CTs of suitable ratio – 01 set (set of three)(v) Indicating lamps (R,Y,B) - 01 set (set of three)(c) Outgoing :- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 160amps rating and minimum 25 KA rupturing capacity, adjustable thermal and fixed magnetic type with spader (Ics=100%Icu) -02 Nos(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 100 amps rating and Minimum 16 KA rupturing capacity, adjustable thermal and fixed magnetic type with spader ( Ics=100%Icu). - 02 Nos.(iii) MCB 4 pole , 'C' curve LT 415 Volts, 50 Hz AC grade 63 amps rating and Minimum 10 KA rupturing capacity, adjustable thermal and fixed magnetic type with spader ( Ics=100%Icu). - 03 Nos.(d) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job.Drawing shall be submitted from manufacturer for approval by Engr in Charge. |
| 27 | Supply, installation, testing and commissioning of LT Panel, LT415 Volt, 50 Hz , 3-phase, 4 wire supply) of size not less than (1.5 X 1.2 X 0.5m) CPRI approved/tested , factory assembled, out door type conforming to IP 54, weather and vermine proof Made out of 2.00 mm thick CRCA sheet with front hinged, single door opening, rubber lining, locking arrangement, painted internally and externally with powder coating of grey shade (RAL-7032) as per seven tank process complete mounted comprising of the following :-(a) Bus bas chamber having 4 nos of air insulated Aluminum strip bus bars of rating not less the 1.5 times the rated capacity of the incomer MCCB, Bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminum four pole(bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming :- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade, 400 amps, 36 KA, Adjustable thermal and Adjustable magnetic release (Ics=100%Icu).- 01 No.(ii) Digital Voltmeter of suitable capacity, of suitable0-500V with selector switch 96 mm X 96 mm square flush mounted, with three way rotary selector switch-1 No.(iii) Digital Ammeter of suitable capacity, size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) CTs of suitable ratio – 01 set (set of three)(v) Indicating lamps (R,Y,B) - 01 set (set of three)(c) Outgoing :-(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 250 amps rating and minimum 25 KA rupturing capacity, adjustable thermal and fixed magnetic type with spader (Ics=100%Icu) -01Nos(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 160 amps rating and Minimum 16 KA rupturing capacity, adjustable thermal and fixed magnetic type with spader ( Ics=100%Icu). - 01 No.(iii) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade 100 amps rating and Minimum 16 KA rupturing capacity, adjustable thermal and fixed magnetic type with spader ( Ics=100%Icu). - 02 Nos.(iv) MCB FP C curve 63A 10 KA breaking capacity - 01 nos(v) Change over 400A- 01 nos.(d) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job.Drawing shall be submitted from manufacturer for approval by Engr in Charge. |
| 28 | Supply, installation, commissioning and testing of factory made, out door type, self standing, double door, front and back openable, made of 3.15mm CRCA MS sheet APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 120 KVAR (5+5+10+10+20+20+25+25 KVAR with 7% detuned harmonics filter reactor) with thryister control module and MCCB TP of 16 KA of 1.5 times of rating current of each capacitor suitable for each control and MCCB TPN 200 Amps 16 KA as incomer including control CT & control wiring complete having follows assessories including control wiring with HR FRLS copper wire complete all as specified and directed including taking down existing u/s panel :-Notes :-(i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry.(ii) Capacitor installed in removable assemblies for ease of operation and maintenance.(iii) Incoming APFC panel of MCCB TPN 200 Amps 16 KA breaking capacity with electrolytic grade aluminium bus bar of suitable rating.(iv) 120KVAR (5+5+10+10+20+20+25+25 KVAR with thyrister control module and MCCB TP of 16 KA of 1.5 times of rating current each capacitor suitable for each control (each capacitor bank equipped with discharge register) & 7% detuned harmonics filter reactor.(v) High performance microprocessor based 3 Phase APFC relay 8 stage with Auto/Manual option.(vi) In built 3 Phase power analyzer, Ammeter, Voltmeter and PF meter (each have 01 No)(vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors.(viii) Induced air system provided with axial flow / centrifugal fan.(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front. |
| 29 | S&F in replacement PVC junction box suitable for street light of size not less than internal dimention 250mm x 200mm x 105mm, made out of polycarbonate having front side openable shutter duly provided with locking arrangement and provided with 04 Nos aluminium bus bar of rating 32 Amp alongwith 01 No MCB 6 Amp SP and provision of cable entries,and cable gland fixed on street light pole with proper size MS clamp with nut & bolt and connected assessories complete all as specified and directed.Note:- cost of MS clamp & nut bolts is included with rate. |
| 30 | M&L for preparation of external surfaces of steel tubular poles / rail / garden poles of any height and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed. |
| 31 | Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. |
| 32 | All as per item No 30.00 above but using 25X4 mm GI strip protected by 32 mm GI pipe light grade complete all as specifed and directed. |
| 33 | S & F in repairs LT heat shrinkable sleeves suitable for 1100 V cables of any size and colour for protection of cables complete all as specifed and directed |
| 34 | Supply, installation, commissioning and testing in replacement of MCCB 400 Amp, 36 KA ,415V adjustable thermal and fixed magnetic type,Ics=100%,Icu” current range for overload protection and thermal release complete with spreader terminals (legs) and with proper lugs complete & including making all fixing arrangement, cutting welding of existing panel board as per site requirmen & old taking down all as specified and as directed. |
| 35 | All as per item No 33.00 above but of capacity 250 Amp ,36 KA complete all as specified and directed. |
| 36 | All as per item No 33.00 above but of capacity 200 Amp ,36 KA complete all as specified and directed. |
| 37 | All as per item No 33.00 above but of capacity 160 Amp ,16 KA complete all as specified and directed. |
| 38 | All as per item No 33.00 above but of capacity 125 Amp ,16 KA complete all as specified and directed. |
| 39 | All as per item No 33.00 above but of capacity 100 Amp ,16 KA complete all as specified and directed. |
| 40 | All as per item No 33.00 above but of capacity upto 63 Amp ,16 KA complete all as specified and directed. |
| 41 | Materials and Labour Cutting /boreing of existing road / path , hardstandingetc for taking out cable and water pipe to protection with iron cover plate for passing cable,water pipe and making good the disturbed road top surfaces with following cement concrete all type, using of suitable depth and finished with speed breaker complete all as under directed. |
| 42 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation base of poles and other similar locations all as specified & directed including demoltion of old PCC/broken PCC |
| 43 | Supply and laying GI pipe medium light grade with all fittings in trenches :- |
| 44 | 50mm bore of GI pipe |
| 45 | 80mm bore of GI pipe |
| 46 | M & L for LT Danger notice plate of size 20 X 15 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS CLAMPS, bolts, and nuts of approved size complete all as specified and directed. |
| 47 | Material and labour for painting of LT panel boards with the help of spray paints, outdoor/indoor of any size, floor/wall mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 48 | Supply and fixing in replacement Indicator Lamp LED type (R-Y-B) 240 V, AC, single phase, on existing LT panel , all as directed Engr In Charge. |
| 49 | M & L in replacement Digital type Volt Meter 96 mm x 96 mm, of range 0-500 volts, class -1, including internal wiring with 1.0 sqmm single core PVC wire all as specified and directed. |
| 50 | M & L in replacement Digital type Ammeter 96 mm x 96 mm, single phase , range up to 0-600 Amp, class -1, including internal wiring with 1.0 sqmm single core PVC wire all as specified and directed. |
| 51 | S & F in replacement Digital type MFM 96 mm x 96 mm, single phase , including internal wiring with 1.0 sqmm single core PVC wire all as specified and directed. |
| 52 | Material and labour for repairing of existing LT panel by welding, replacing of broken hinges as per existing size all as directed . |
| 53 | Material and labour for repair of LT panels/LT feeder piller/ APFC by carrying out checking thoroughly all electrical connections, lugs busbar, voltmeter, ammeter ,cable glands ,insulator on busbar, and tightening all connections properly with proper size of nut, bolt, washer, cable tie as per the site requirements and insulation of busbar with colour code insulation tapes lete all as specified and directed. |
| 54 | Supply and laying double wall corrugated pipe (DWC SN-4) in replacement conforming to IS 19430 Part - I of size 63 mm outer dia and 50 mm inner dia including accessories complete all as specified and as directed |
| 55 | M&L for Boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including S&F HDPE DWC pipe of 150 mm unternal dia for SN-8 working pressure for laying of cable complete all as specified and directed. |
| 56 | Disconnection Elect Supply, taking down of brunt / damage bus bar from LT panel and Supply & fixing in replacement insulated aluminium bus bar with PVC sleeves and insulator of any size as reqd in existing panel , making holes as reqd, suitable shape by bending and connecting to main bus bar/ MCCBs as existing position all as directed. |
| 57 | Supply, installation, commissioning and testing in replacement of MCCB 250 Amp, 36 KA ,415V adjustable thermal and fixed magnetic type,Ics=100%,Icu” current range for overload protection and thermal release complete with spreader terminals (legs) and with proper lugs complete & including making all fixing arrangement, cutting welding of existing panel board as per site requirmen & old taking down all as specified and as directed. |
| 58 | Supply, installation, commissioning and testing in replacement of MCCB 200 Amp, 36 KA ,415V adjustable thermal and fixed magnetic type,Ics=100%,Icu” current range for overload protection and thermal release complete with spreader terminals (legs) and with proper lugs complete & including making all fixing arrangement, cutting welding of existing panel board as per site requirmen & old taking down all as specified and as directed. |
| 59 | All as per item No 57.00 above but of capacity 160 Amp ,16 KA complete all as specified and directed. |
| 60 | All as per item No 57.00 above but of capacity 125 Amp ,16 KA complete all as specified and directed. |
| 61 | All as per item No 57.00 above but of capacity 100 Amp ,16 KA complete all as specified and directed. |
| 62 | All as per item No 57.00 above but of capacity upto 63 Amp ,16 KA complete all as specified and directed. |
| 63 | M & L for raising height of existing panel by disconnecting all cables connection carefully from panel and taking out cable from loop from existing position as per requirement, raising the height to 600mm in pcc (1:2:4) type C1 including painting of foundation,refixing the panel and reconnecting all the cables after dressing including excavation earth work returning, removal of debris etc complete all as specified and directed. |
| 64 | S&F in repairs Voltmeter meter, digital type, input voltage range 50-520VAC, flush mounting 96 x 96 mm with inbuilt selector switch accuracy class I complete including taking down of old UNSV complete all as specified. |
| 65 | S&F in repairs Ampere meter, digital type, input voltage range 50-520VAC, flush mounting 96 x 96 mm with inbuilt selector switch accuracy class I complete with suitable size of CT's, including taking down of old UNSV complete all as specified. |
| 66 | S & F in repairs push button flush type suitable for panel complete all as specified and directed including taking down of old UNSV. |
| 67 | S & F in repairs selector rotary switch 6-16A complete all as specified and directed including taking down of old UNSV. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST