Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58549337

Tender For Repair / Maintenance Of Water Supply Pipelines, Valves And Cleaning Of Reservoirs At Hastings And Repair/ Replacement Of Street Light, Garden Lights, Cables, Connected Switch Gear At Hasting, Od, Saahapore & Raspunja Under Ge (C ) Kolkata

Issued by Statutory Bodies & Commissions/Committees · Kolkata, West Bengal
Tender Value
43 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Water Supply Pipelines, Valves And Cleaning Of Reservoirs At Hastings And Repair/ Replacement Of Street Light, Garden Lights, Cables, Connected Switch Gear At Hasting, Od, Saahapore & Raspunja Under Ge (C ) Kolkata

BOQ

Name of Work:- REPAIR / MAINT OF WATER SUPPLY PIPELINES, VALVES AND CLEANING OF RESERVOIRS AT HASTINGS AND REPAIR/ REPLACEMENT OF STREET LIGHT, GARDEN LIGHTS, CABLES, CONNECTED SWITCH GEAR AT HASTING, OD, SAAHAPORE & RASPUNJA UNDER GE (C ) KOLKATA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA NAME OF WORK: REPAIR / MAINT OF WATER SUPPLY PIPELINES, VALVES AND CLEANING OF RESERVOIRS AT HASTINGS AND REPAIR/ REPLACEMENT OF STREET LIGHT, GARDEN LIGHTS, CABLES, CONNECTED SWITCH GEAR AT HASTING, OD, SAAHAPORE & RASPUNJA UNDER GE (C ) KOLKATA Contract No: GE (C )/KOL/ OF 2025-26 (8996) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Supply and Fixing in repair LED flood light fitting for high mast of cap 150 Watt, and efficacy > 110 LPW 240 Volts 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light with built in 10 Kv protection suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
3Supply and Fixing in rep[air LED flood light fitting of cap 120 Watt, 240 Volts, and efficacy > 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light with built in 10 Kv protection suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
4Supply and Fixing in repair LED flood light fitting of cap 80 Watt, 240 Volts, and efficacy_> 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light with built in 10 Kv protection suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
5Supply and Fixing in repair LED street light fitting of cap 90 Watt (or nearest higher Cap), and efficacy > 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die-cast aluminium IP65 protection with with built in 10 Kv protection high power LEDs as light source, including all accessories for fixing or mounting complete all as specified and directed.
6Supply and Fixing in repair LED Street light fitting 60 Watt, and efficacy > 110 LPW 240 Volts new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device, including fixed on wall / pole all as specified and directed.
7Supply and Fixing in repair LED street light fitting 45 Watt, and efficacy > 110 LPW 240 Volts, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP66 protection and impact resistance of IK07 including fixed on wall / pole all as specified and directed.
8Supply and Fixing in repair post top LED lantern of capacity 30 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection and efficacy > 110 LPW 240 Volts with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
9Supply and Fixing in repair post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection and efficacy > 110 LPW 240 Volts with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
10Supply and fix in repair LED bollard light tulip shaped 9/10 watt capacity with opal acrylic IP 65 protection including necessary connection and including PCC work for each bollard light taking down old unserviceable one complete all as specified and as directed.
11Supply and fix in repair LED bollard light inverted pyramid 9/10 watt capacity with opal acrylic IP 65 protection including necessary connection and including PCC work for each bollard light taking down old unserviceable one complete all as specified and as directed.
12S & F in repair focus light made up of die cast,aluminium housing with system efficacy > 110lm/w, AC 120-300V, CRI 70+, IP 66 rating ,10 watt in red/green/blue/ warm white with surge protection greater then 4KV & THD <10% with electrical connection complete all as specified and directed.
13S&F in replacement LED drivers suitable for capacity 35 to 150 watt operating voltage 180v-270v AC 50/60 HZ out put voltage 36V DC/2.8 Amp power factor 0.95 for any make street light/Flood light complete all as specified and directed.
14S&F in replacement LED post top lantern/bollard light drivers suitable for capacity 10-40 watt any make including fittings arrangement and taking down old one complete all as specified and directed.
15S&F in replacement surge protection device 10 KV for LED light fitting complete all as specified & directed.
16S&F in replacement street light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 meter length fixed with & including necessary MS Clamps of size 40X5mm 02 No's (medium grade) including nuts, bolts and washers on pole etc complete all as specified and directed.
17S&F in replacement 20 mm rigid non-metallic PVC conduit inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified & directed.
18S&F in replacement FRLS PVC insulated and PVC sheathed 2.5 sqmm 3 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
19S&F in replacement FRLS PVC insulated and PVC sheathed 1.5 sqmm 3 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
20S&F in replacement FRLS PVC insulated and PVC sheathed 6 sqmm 4 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
21S&F in replacement twin core flat 4 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
22S&F in replacement twin core flat 6 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
23Labour only for disconnecting, taking out defective under ground LT cable of length not more than 3 meter and of size 10 sqmm to 25 sqmm including excavation, taking out bricks cover and relaying the old cable in loop and making connection with proper new thimbles with cut out boxes,Feeder pillar box, MCBs junction box etc including refilling of sand, relaying old bricks and returning, filling in soil etc complete all as specified and directed.
24S&F in replacement PVC junction box suitable for street light of size not less than internal dimention 250mm x 200mm x 105mm, made out of polycarbonate having front side openable shutter duly provided with locking arrangement and provided with 04 Nos aluminium bus bar of rating 32 Amp alongwith 01 No MCB 6 Amp SP and provision of cable entries,and cable gland fixed on street light pole with proper size MS clamp with nut & bolt and connected assessories complete all as specified and directed.Note:- cost of MS clamp & nut bolts is included with rate.
25Taking out the old unserviceable LT underground cable of any size & any description 1100 volts grade,and stacking at one place for rescue from trenches/wall/floor/road/ culverts or pole etc including brick cover complete all as specified and directed.Note : Excavation and earth work, duct work shall be measured and paid separately.
26Supply , laying , jointing, testing and commissioning of size 10 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection GI/DWC pipe shall be paid separately.
27All as per item No 25 above but of size 16 Sqmm 4 core complete all as specified and directed.
28Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom suface to required level complete all as specified and directed
29Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed
30Returning filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed.
31Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment.
32Laying only in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
33Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
34Supply and laying double wall corrugated pipe (DWC), SN-4 conforming to IS 19430 Part - I of size 50mm outer dia and 38 mm inner dia complete all as specified and as directed.
35S&F in replacement MCB SPN of capacity 6A to 32A , 10 KA, C' curve, 240 volts complete all as specified and directed.
36M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form workand plastering complete all as specified & directed including demoltion of old PCC/broken PCC complete all as specified and as directed
37M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation base of poles and other similar locations all as specified & directed including demoltion of old PCC/broken PCC
38M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate with and including all necessary form work complete all as specified & directing including demoltion of old PCC/broken PCC
39M & L mild steel tubular sewaged pole 9 mtr long completed with MS base plate, finial taper plug nut bolts, screws as specified type 410 SP-31 as per relevant IS specifiecation including two coats of aluminimum paint over a coat of red oxide primer including taking down old one. all as directed by Engineer-in-Charge. (Note : Earth work/excavation PCC shalll be measured separately)
40Supply, fixing, installing and commissioning of Octagonal Hot-Dip Galvanised Street light Pole 7 mtr long, Top dia 70mm (A/F),130 mm bottom dia (A/F),sheet thickness -3mm, base plate dimensions 225X225X12mm & foundation bolts 4X M20 dimensions etc shall be all as mentioned in manufacturer’s Cat Part, sheet thickness 3mm, single arm bracket, suitable for 1100 Volts grade including cost of nuts, bolts and all accessories as supplied by the manufacturer, door locking arrangement, Terminal Plate consisting of 2 Nos 10A, 4 Pole neutral links including connections etc with suitable connecting arrangement for 1 Nos (incoming & outgoing), including cost of foundation, excavation and earthwork in soft/loose soil, RCC {1:1.5:3 type A1} for foundation of shape & size all as per manufacturer’s instruction complete all as specified and directed, Material specification mast & pole shaft : BSEN 10025, ASTM A572, IS 5986, Foundation – IS 2062/E250A, Base Plate IS-2062, Galvanization IS:4759/2629 and ASTM A123. Make:-Crompton Cat Part No HM-1107P / or equivalent in Bajaj/Jinal/Surya.
41Materials and Labour Cutting / horizontal boreing of existing road / path , hardstandingetc for taking out cable and water pipe to protection with iron cover plate for passing cable,water pipe and making good the disturbed road top surfaces with filling cement concrete (1:3:6) upto of suitable depth and finished with speed breaker complete all as uder directed.
42S&F Straight through joint kit heat shrinkable 10 to 25 sqmm 4.0 core for LT 1100 Volts grade with jointing materials and accessories suitable for 3.5/4 core XLPE armoured conductor cable complete all as specified and directed.
43Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line/pole and removing the same upto 150 mtr away & each span not exceeding 70 mtr etc complete all as specified and directed.Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required.
44M&L for preparation of old painted surface of steel tubular LT poles 9m/11m long and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces by applying red oxide primer including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed.
45M & L Rewinding of electric motor AC 3phase 415 volts 50- HZ of capacity 0.5 HP with supper enamel copper wire of same size and heating and varnishing after removing the old burnt out winding including replacement of bearing etc testing & commissioning complete all as specified and directed.
46M & L for removing/dismanlting lantern/carriage from High mast light, by dismanlting arms, wire , rope, from top and refixing again repair, aligning properly to smooth operation including necceary minor parts complete all as specified and directed.
47S & F in replacement of havy duty eletrical trailing cable size of 4 sqmm 5 core ( Ethylene Propylene Rubber) insulation PCP ( Polychloroprene ) or rubber sheathing to withstand constant flexing, high tensile strenght for high mast light pole size of 16 to 20 mtrs complete all as specified and directed.
48Supply and fix Timer switch with ML2 CONTACTOR of Analogue type for street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed.Make:- L&T Cat part No. AUTS01ANA00 or equivalent model from make:- Schneider / ABB / SIEMENS
49Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed
50Taking existing pipe line of any type from trenches, walls, floors etc including cleaning for refixing or removal of unserviceable pipe from site all as directed.
51100mm bore
5280mm bore
5350mm bore
5440mm bore
5525mm bore
5620mm bore
57Supply & laying GI tubing medium grade galvanised with all fittings (union, elbow, socket, flanges with nut bolts & gasket) laid in trenches complete all as specifed and as directed for the following bores
5880mm bore
5950mm bore
6040mm bore
61(25mm bore
6220mm bore
63All as per item No. 50.00 but fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket, flanges with nut bolts & gasket) using necessary arrangement for scaffolding upto building of 12 storey height any type complete all :-
64(a) 80mm bore
65(b) 50mm bore
66(c) 40mm bore
67(d) 25mm bore
68(e) 20mm bore
69M & L for re-fixing of old steel tubing obtained from item no 49 and connection in new or old position after thorough cleaning and removing any blockages.with and including all new fittings complete all as specified and directed.
70100 mm bore size
7180 mm bore size
7250 mm bore size
7340mm bore size
7425 mm bore size
7520mm bore size
76Supply , laying & jointing in trenches ductile iron 150mm dia pipe K-7, ISI marked of standard length with internal cement motor coating & external surface with bituminous paint spigot and socketed end, push type joint including rubber gasket as jointing material including taking out u/s one complete all as specified and directed
77All as per item No. 53.00 here in before but for 100 mm bore
78M/L for fixing in repairs CI specials such as Cast Iron bends (any type, radius and angle), tapers (any type I.e straight, bend, increasing or decresing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross, collar, caps, connecting pieces up to 150 mm dia complete all as specified and directed
79M & L Lead wool joints suitable for spigot & socketed CI Pipes and caulking the joints properly for avoiding leakage etc for the following sizes as directed :-
80150 mm bore size
81100 mm bore size
8280 mm bore size
83S & F in repair Cast iron detachable joint (CID) with all accessoires suitable for the following sizes of pipes:-
84150 mm bore size
85100 mm bore size
8680 mm bore size
87Supplying and laying of CPVC pipe of 25mm bore (32 mm OD) size SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/ trenches with all fitting (union, elbow, socket) complete all as specified and directed
88All as per item No. 58.00 here in before but for 20 mm bore (25 mm OD)
89S&F CI sluice valve (class PN 1.6) 150mm bore ISI market with SS spindle both ends flanged iron wheel with necessary size of gaskets nuts, both washer etc including taking down the unserviceable complete all as specifed & directed.
90All as per item No. 60.00 here in before but for 100mm bore.
91All as per item No. 60.00 here in before but for 80 mm bore.
92M & L for welding of broken pipe / flanges etc by cleaning the rust,dust and preperation of surface for welding including dismantling the existing and refixing again after repair complete all as specified and directed.
93S&F gun metal gate valve screwed both ends for iron pipes with ironwheel (ISI marked) including taking down the unserviceable complete all as specified and directed
9480mm bore
9550mm bore
9640mm Bore
9725mm bore
9820mm bore
99M & L Cutting drilling & tapping of existing CI/DI pipe line by necessary tools with out damaging the pipe line as required upto 150mm dia complete all as specified.
100M & L for opening stuffing box of sluice valve and S&F new Stainless steel spindle with check nut fabricated out of superior quality all as per sample as required at site including replacement of unserviciable rubber gasket, bolts, nuts & washers suitable for following size of sluice valves:-
101150mm bore
102100mm bore
10380mm Bore
104M&L for cleaning of under ground sump or service tank of capacity 100000 gallon through bactrological treatment and ultra violet ray in following including writing the date of cleaning complete all as specified and directed(a) To drain out the water by using exit valve or our own high capacity dewatering system.(b) Cleaning all the algae formation inside the tank using wire brush, scrubbing the walls, floor of the tanks and bacteriological cleaning by UV ray etc.(c) Fresh water cleaning by high speed jet pump and draining out all the mud from the tank and cleaning of the floor thoroughly with clean water to obtain clean surface.
105All as per item No 70.00 here-in- before but under ground sump of capacity 60000 gallons
106All as per item No 70.00 here-in- before but under ground sump of capacity 22000 gallons
107All as per item No 70.00 here-in- before but under ground sump of capacity 12500 gallons
108All as per item No 70.00 here-in- before but under ground sump of capacity 6250 gallons
109All as per item No 70.00 here-in- before but under ground sump of capacity 5000 gallons
110All as per item No 70.00 here-in- before but over head tank of capacity 1000000 gallons
111All as per item No 70.00 here-in- before but over head tank of capacity 75000 litre
112All as per item No 70.00 here-in- before but over head tank of capacity 45000 litre.
113M & L for double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of both workers and the building for length of 2 M and height of upto G+12 complete all as specified and directed
114Supply only Calcium based High strength Chlorination chemical, Make - Purichlor/Altoc contains chlorine contents not less than 65% for water Disinfection complete all as specifed & as Directed.
115M & L for paintig the external surface of existing pipeline surfaces of any description, upto 250mm bore by scrapping the surface, applying red oxide primer & 2 coats of synthetic enamel paint with approved colour complete all as specified and directed.
116M & Labour only for attending emergency external water supply compliants of all nature i.e. leakage in any type of water supply pipe lines, fittings / Fixtures, no water supply involving replacement of fittings like tee, elbow, socket union, etc .from 0600 hrs to 2200 hrs complete all as directed.(Any material required for attending complaints shall be measured & paid separately under respective items hereinafter)
117M&L for construction of valve pit chamber of sizse 2100x1400x900mm internal dimention using sub class-'B' bricks (1:6) plastering in cement mortar (1:4) externally & internally extended to 15CM below ground level incl pcc bed 10 cm in PCC 1:3:6 type C2 with MS frame fabricated by angle of size 50x40x6mm complete with top cover of 3mm ms sheet & locking arrangement and painting with two coats of synthetic enamel over a coat of red oxide primer and cement surface with cement based paint. including demolition of damaged valve pit all as specifed & directed.
118M&L for construction of valve pit chamber of sizse 1050x1050x900mm internal dimention using sub class-'B' bricks (1:6) plastering in cement mortar (1:4) externally & internally extended to 15CM below ground level incl pcc bed 10 cm in PCC 1:3:6 type C2 with MS frame fabricated by angle of size 50x40x6mm complete with top cover of 3mm ms sheet & locking arrangement and painting with two coats of synthetic enamel over a coat of red oxide primer and cement surface with cement based paint. including demolition of damaged valve pit all as specifed & directed.
119M&L for construction of valve pit chamber of sizse 900x900x900mm internal dimention using sub class-'B' bricks (1:6) plastering in cement mortar (1:4) externally & internally extended to 15CM below ground level incl pcc bed 10 cm in PCC 1:3:6 type C2 with MS frame fabricated by angle of size 50x40x6mm complete with top cover of 3mm ms sheet & locking arrangement and painting with two coats of synthetic enamel over a coat of red oxide primer and cement surface with cement based paint. including demolition of damaged valve pit all as specifed & directed.
120M & L Repair of valve chamber by cleaning and removing small bushes inside and surrounding the valve chamber and necessary brick works, plastering in cement mortar 1:4, painting with cement based paint of 2 coats inside and out side including dismantling of unserviceable MS sheet cover, S & F new MS sheet cover of 3.00mm thick with 2 coats of synthetic enamel paint over a coat of red oxide to steel surface and locking arrangements, including necessary welding upto 90cmx 90cm x 90 cm (internal dimension) all as directed.
121M & L for painting of valve chamber of any size with two coats of cement based paint inside and outside of chamber and chamber cover with two coats of synthetic enamel paint over one coat of red oxide primer including replacement of rusted / damaged metal hinges / locking by welding with valve chamber frame and removing small bushes and grass inside & outside of valve chamber all as specified and directed
122M&L Painting to UG sump manhole cover with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces etc all as specified and directed
123M & L for painting of valve pit chamber with black paint over one coat of red oxide primer including preparation of surfaces etc complete all as specified and directed
124Taking sample of raw water/tap water from Pump Houses & getting tested by Deirectorate of PHED office by collection of sample from Pump House for physical, Chemical and Bacterelogical analysis. Report shall be submitted to engr-in-charge complete all as specified and directed.
125M & L top cover valve pit chamber made of MS sheet 3 mm thick & locking arrangement with MS frame fabricated by angle of suitable size and painting with two coats of synthetic enamel over a coat of red oxide primer including removal of rusted damaged top cover.
126M/L providing cement concrete type C1 (1:3:6) using 20mm graded stone aggregate as in roof kerbs or mud stops, base for valve pit, making good the road cutting and like, rounded or chamfered on edges all as specified and directed
127M & L rendering 10 mm thick plaster in CM 1:6 on brick work or concrete surface, finished even & smooth without using extra cement all as specified and directed.
128M &L brick work with burnt bricks best quality locally available bricks old size laid staright or curved on plan to any radius built in cement mortar 1:4 complete all as directed including dismantling old complete all as specified and directed.
129S & F in repairs wire netting of stainless steel wire 1.4 mm dia fixed with tinned tacks of stainless steel wire staples of size 12 mm for covering UG sump air vent as specified and directed
130Supply and laying 50mm outer dia, 3 - layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and anantimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threarded polypropylene random fitting laid in trenches/wall/floor complete with all the fittings with following outer diameter to replace above mentioned bores of pipe complete all as specified and directed.(a) Pipe inner dia should match existing pipe inner dia.(b) Wall thickness of pipe shall be all as per I.S. 15801.
131Supply & fixing PP-R Gate valve upto 50mm (brass insert) outer dia as per requirement of the site including taking out the U/S old one (ISI marked) complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58549337
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Water Supply Pipelines, Valves And Cleaning Of Reservoirs At Hastings And Repair/ Replacement Of Street Light, Garden Lights, Cables, Connected Switch Gear At Hasting, Od, Saahapore & Raspunja Under Ge (C ) Kolkata
Basic Detail
Tender No 8996/E8
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 16 Nov 2026
Submission Date 07 Dec 2026
Open Date 08 Dec 2026
Finance
Tender Value 43 Lakhs
Tender Fee 500
EMD 86000
Exemption Available
Document List
8996Tenderdocus.pdf
bbfd7d94-a6b9-40c3-b9fc-73c75cf0102c.html
BOQ_896290.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

8996Tenderdocus.pdf

html

bbfd7d94-a6b9-40c3-b9fc-73c75cf0102c.html

xls

BOQ_896290.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender