Tender For Modernisation/ Strengthening/ Upgradation Of Divisional Workshop Including Supply And Installation Of Testing Equipments, Chain Pully Blocks And Associated Items For Division Ivth Khanyar, Srinagar,Under Ut Capex-2026-27.Scheme Code: Pddss
Tender Overview
Project Description
Tender for Modernisation/ Strengthening/ Upgradation Of Divisional Workshop Including Supply And Installation Of Testing Equipments, Chain Pully Blocks And Associated Items For Division Ivth Khanyar, Srinagar,Under Ut Capex-2026-27.Scheme Code: Pddss2627100218
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing & Commisioning of following |
| 2 | Autoranging AC/DC Clamp/ Hook On Meter with probes and Case cover, Jaw Size: 55mm, AC Current: 1000A Max for 1 Min, DC Current: 1200A |
| 3 | Digital Insulation Resistance Tester - Voltage Testing Range 5000V, Meg ohmmeter Insulation Resistance 200G ohms. |
| 4 | 5000V-5000 Meg Ohms Analogue Insulation Tester Hand Driven housed in anti-Magnetic metal body. Silent Generator, Accurate & Quick response Confirms to ISS : 2992/1987 |
| 5 | Corded Electric Impact Drill, 600 W, 13 mm, 3,000 rpm, 1.4 Nm, Impact rate at no-load speed- 0 – 48,000 bpm; Rated torque- 1.4 Nm; |
| 6 | Digital Micrometer, Durable High Accuracy Electronic Micrometer, 0-25mm, LCD Digital Display |
| 7 | 12 Volt Seal Maintenance Free (SMF) Lead Acid type, Fresh 150 Ah capacity at 20°C suitable for DG set 62.5kVA, Min 3 years unconditional replacement guarantee. |
| 8 | Drilling Machine with 3 phase motor and stand heavy duty alongwith Drill Bits of sizes. |
| 9 | Hydraulic crimping tool with die's ranging from 10-400mm |
| 10 | 3 Phase Automatic Transformer Turn Ratio Meter |
| 11 | Digital Micro Ohm Meter with Calibration Certificate |
| 12 | Upgradation of Three Phase Contactor from 20 Amp to 32 Amp for Temperature Control Oven. |
| 13 | Upgradation of manual temperature controller to Digital PID Temperature Controller with Timer. |
| 14 | Upgradation of analogue circuit for Voltage Control alongwith Auto/Manual Circuit board for 100kVA AVR to Digital Voltage Control module for Auto/ Manual shifting and High Cut and Low Cut Voltage Cutoff for 100kVA AVR. |
| 15 | Upgradation of 1HP Wrench Motor for 30 feet iron shutter for Divisional workshop with Clutch assembly alongwith Chain gears to 2HP Wrench Motor for 30 feet iron shutter for Divisional workshop. |
| 16 | Upgradation of Motors for OHT Crane from 2 HP to 3 HP with Clutch assembly. |
| 17 | Making of Foundation Base Bed and Canopy for 62.5kVA Dedicated Generator Backup Supply for Electric Sub Division Workshop. |
| 18 | Earthing of Generator Set by way of excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75mm x10mm & 50mm x 6mm for connection to Generator as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 19 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 fine sand) including curing. |
| 23 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 24 | Laying of RCC foundation including proper curing. 200mm X 200mm X 500mm (RCC with concrete ratio 1:1.5:3 with template comprising of 4 Nos. of M10 100mm Long longitudinal MS Anchor Bolts with Nuts & Washers for fixing the pole and MS Base Plate 150mmX150mmx6mm). As per Drawing. |
| 25 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 26 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gram/m2 |
| 27 | Providing and fixing flashing of 40cm overall width in plain G.S. sheets fixed with polymer coated J or L hooks, bolts and nuts G.I. limpet and bitumen washers complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand). 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 28 | Providing and fixing 15cm wide 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gram/m². |
| 29 | Providing flat iron brackets 50 x 3 mm size with necessary bolts, nuts and washers etc. for fixing asbestos cement/ G.S. sheets gutters with purlins. |
| 30 | 3X1.5 mm² PVC insulated multistrand flexible copper wire for service connections from connection plate to luminary individual circuit including loop & earthings laid properly. |
| 31 | Plastic Conduit Pipe 1\\" Dia. |
| 32 | Bulb Holder Socket. |
| 33 | Plastic Box enclosures for Light Switches. |
| 34 | 5A Plastic Light Switches. |
| 35 | 10 Watt LED Bulbs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender