Project Description

Tender For Repair/Maintainance Of Temp Accn Viz Barracks And Sheds Under Age B/R Ii Of Ge (Nw) Nofra.

BOQ

Name of Work:- REPAIR/MAINTAINANCE OF TEMP ACCN VIZ BARRACKS AND SHEDS UNDER AGE B/R II OF GE (NW) NOFRA.
Sl. No. Item Description
1Note: - The tenderer shall note that before quoting his unit rate, all items of works shall be executed in high rise building & including provision of necessary scaffolding & safety measures.Rate inclusive of necessary cleaning of floors, glass and furniture affected by painting.
2Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame) , complete all as directed.
3S&F powder coated (colour of coating as directed) aluminium (minimum 50 micron thickness of coating) of various section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc. rubber beading, clips locking arrangement, handle, sealant etc all as specified and as directed.
4Hacking out old broken glass (any thickness, size, quality or description) from iron frames glazed with putty or wooden beads complete all as specified.(Work carried out upto 7th floor of building either from inside or from outside.)
5S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane all as directed.( Work carried out upto 7th floor of building either from inside or from outside.)
6S&F 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete.( Work carried out upto 7th floor of building either from inside or from outside.)
7S & F sheet glass of 4.0 mm thick selected quality in square and exceding 0.5 Sqm in each pane, complete all as specified.
8S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed.
9S&F in repairs fancy type drapery rods, powder coated aluminium of 20-25mm size with / including fixing brackets, Knobs rollers etc.all as specified.
10Preparation of old plastered surfaces of walls and apply two coat distemper oil emulsion over a coat 2 mm thick wall care putty complete all as specified.
11M&L for preparation of old wall surfaces and applying two coats of oil emulsion distemper complete all as specified and directed.
12M&L preparation of old distempered surfaces of walls and applying one coat of oil emulsion distemper on walls etc all as specified.
13Material & Labour for complete removal of existing treatment of walls by washing down and smoothing old surface of walls/ ceiling, prerparation of surface by a thin layer putty and applying two coats of interior emulsion over a coat of primer over a layer of smooth Putty finish punning 3mm thick strictly as per manufacture instruction with smooth roller finish ,complete all as specified and directed.
14M&L for cleaning of PCC paver block, chequred tiles and any type of PCC flooring by water spray and apply one coat of acrylic emulsion paint suitable for floor by using brush, complete all as specified.
15M&L for preparation of old surfaces of walls and applying two coat of white wash on walls etc all as specified.
16M&L for preparation of old plastered surfaces on ceiling and applying two coats of white wash on ceiling.
17M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint & ht. upto 7th floor of bldg., complete all as specified.
18M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint & ht. upto 7th floor of bldg., complete all as specified.
19M&L for preparation of old surface of wooden of any description including cleaning and applying one or more coat french polish till achiving desired finish all as specified and directed by Engeer- in charge.
20M&L for preparation of old decorated surfaces of walls by scrapping old paint by steel wire brush, wash the surface throughly and applying one coat of acrylic emulsion exterior grade (100%) including necessary steel scaffolding all round the work side for any posititon/height, complete all as specified and directed.Note :-Necessary safety precautions need to be taken before applying paint.
21M&L for preparation of old decorated surfaces of walls by scrapping old paint by steel wire brush, wash the surface throughly and applying two coat of acrylic emulsion exterior grade (100%) including necessary steel scaffolding all round the work side for any posititon/height, complete all as specified and directed. Note :-Necessary safety precautions need to be taken before applying paint.
22Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land
23M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified.
24M&L for coloured glazed ceramic tiles 450x300x7 / 350x250 x7 mm mm thick but as on vertical surfaces such as skirting/dado including 15 to 20mm thick backing coat in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
25M&L for light shade coloured vitrified ceramic tiles 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 Sqm in floors / in wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
26Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified.
27M&L 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table, floors and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding and rounding all as directed.
28M&L for machine cut cudappa stone slab 20-25 mm thick laid over screed base in cement and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
29M&L, for mirror polished machine cut kota stone slab flooring 20-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
30M&L, for machine cut kota stone slab 20-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
31Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
32M&L for 40 mm thick cement concrete type B-1 , 1:2:4 (20 mm graded stone agg) as in floor and fisnishing cement concrete surface even and smoothby using extra cement all as directed.
33M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling ad mass concrete, complete all as specified.
34M&L for cement concrete interlocking paver tiles 60 mm thick having glossy finish (colour and pattern approved by GE) (tested as per IS 1237-1980) laid over 50 mm thick dry sand cushioning and voids filled with dry and surface compaction by means of surface vibrator including taking down, complete all as manufacturer instructions specified and directed.
35Grinding and polishing existing floor of any type (kota stone/mossaic/cuddpah stone floor) complete all as specified.
36Dismantling of ceiling boards any thickness etc including aluminium grid frame work complete all as specified and as directed.
37S&F of false ceiling at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2 %, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225P1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true bhorizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm icluding both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully mm center to center and 40mm long dry wall wood screws with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tiles. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge.
38Taking down ceiling board/tiles from aluminium snap grid frame work and refixing in the same position after necessary tightening the sagging portion, replacement of the Main Tees, cross Tees, angles, suspending if required, including bolts, necessary washer,nut/clits/pin hook etc for securing frame work to ceiling to the snap grid complete all as specified and as directed.
39Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
40Material and labour for brick work with sub class \\"B\\" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified.
41M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4), complete all as specified.
42Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, upto 7th floor of bldg.,complete all as specified.
43Rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces in patches, surfaces to be finished even and smooth without using extra cement, complete all as specified.
44M&L plastering 10mm thick in CM 1:3 in ceiling finishing even and smooth without using extra cement, complete all as specified.
45Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions & ht. upto 7th floor of bldg., complete all as specified.(WPC Shall be measured and paid separately.)
46Supply only integral water proofing compound complete all as specified.
47M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer on 1 to 2 mm thick wall care putty all as specified and directed.
48M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer on wall complete all as specified and directed.( Work carried out upto For upto high rise bldg either from inside or from outside)
49M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed.
50S&F in repair of GI tubing medium grade with all fittings like Tee, bend, elbow etc, 15 mm bore fixed to walls or ceilings with saddles/spacers , clips & ht. upto 7th floor of bldg.
51S&F in repair of GI tubing medium grade with all fittings like Tee, bend, elbow etc, 20 mm bore fixed to walls or ceilings with saddles/spacers , clips & ht. upto 7th floor of bldg.
52S&F in repair of GI tubing medium grade with all fittings like Tee, bend, elbow etc, 25 mm bore fixed to walls or ceilings with saddles/spacers , clips & ht. upto 7th floor of bldg.
53Taking down & Refixing 15mm old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.), complete all as specified.
54Taking down & Refixing 20mm old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.), complete all as specified.
55S&F in repair of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 13.5 fittings on walls/ceiling or laying in floors, complete all as specified and as directed.
56S&F in repair of 25mm CPVC pipes SDR 11 & Plain CPVC SDR 13.5 fittings on walls/ceiling or laying in floors, and taking down old tubes of any desc. complete all as specified and directed by Engineer-in-Charge.
57S&F in repairs Gun-metal, globe or gate valves 25mm bore dia., with iron wheel head, screwed both end for iron pipe and fixed over terrace complete all as specified
58S&F in repairs Gun-metal, globe or gate valves 20mm bore dia., with iron wheel head, screwed both ends for iron pipe and fixed over terrace complete all as specified
59S&F in repairs Gun-metal, globe or gate valves 15mm bore dia., with iron wheel head, screwed both ends for iron pipe and fixed over terrace complete all as specified
60Cleaning of loft tank exc 250 ltr capacity (in existing position or disconnecting existing tanks for cleaing and refix in same position incl fixing of all attached fittings) by removing out the residual water from the tank, removing dirt, cleaning the internal surfaces of the tank with high pressure controlled water jet pump by using different nozzles as per requirement. After sucking out entire moss and algae by wet vaccume pump, wash the tank with clean drinking water tank cleaning solution on all internal surfaces, then cleaning the bottom surface of the tank with vaccume pump to make it dry and providing sticker showing the date of cleaning ,complete all as specified and directed.
61S&F in repair of 1000 lit capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed position all specified in SSR Part-I, with and including Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, screwed for iron pipes and fixed above 7th floor terrace, complete all as specified and directed by Engineer-in-Charge.
62S&F in repair of 2000 lit capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed position all specified in SSR Part-I, with and including Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, screwed for iron pipes and fixed above 7th floor terrace, complete all as specified and directed by Engineer-in-Charge.
63S&F in repairs PVC modular section 20mm thick as in profile including 'C' channels, aluminium all around the profile suitable for 300 ltr capacity loft tank , all as specified.
64S&F in repairs 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
65Taking down eaves gutters and rainwater pipes of any dia (any size or pattern ) including all fittings, heads, shoes, bends, swan necks etc (Measured overall as fixed along the centre line over fittings and accessories) & ht. upto For upto high rise bldg . complete all as specified.
66S&F in Repair 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc & ht. upto 7th floor of bldg., complete all as specified.
67Refixing of 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc & ht. upto 7th floor of bldg., complete all as specified.
68S&F in Repair PVC (SWR) bends of 160 mm bore & ht. upto 7th floor of bldg., complete all as specified.
69S&F in repairs 15mm size Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed.
70S&F in repairs fancy type Pillar taps 15mm size cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified.
71S&F in repairs CP angular stop cock 15 mm bore all as specified and directed.
72S&F health faucet ABS Body with 8 mm dia 1 mtr flexible tube and wall hook.
73S&F in repairs, Plastic water closet seat, black or white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.all as directed.
74S&F in repairs flush pipe of PVC 32 mm dia for low level cistern and connected to WC, complete all as specified.
75S&F in repairs SS grating 100 mm dia , and white cement to sides , complete all as specified.
76S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm
77S&F in repairs 32/38 mm dia WHB/urinal /Sink flexible waste pipe all asw specified and directed.
78S&F in repairs aluminium anodised tubular towel rail 20mm dia D type 60 cm long between flanges.
79Repairing of minor complaints of joinery such as wooden/steel/aluminium of any description including pelmet box, cupboard ,drawers, and the like door springs, rolling shutters etc requiring carpentry work like adjusting easing, wrought, cutting, pinning, wedging and finally making good etc and functioning to seating over with each other with tightening of screws/nails , door, springs etc and fixing of tower bolt, sliding door bolt, plate rack, handles of any size incl rawl plug & screws,and including petty repairs material like screws/mails, plug, grease etc to make it functional as in day to day maintenance work, complete all as specified.
80Repairing of minor complaints of plumbing and sanitary fittings including water leakage from taps, EWC”s, flushing cistern, urinals, wash basins, bottle traps etc and any obstruction to water supply in rooms/Qtrs, requiring plumber work with minor stores such as replacement of Brass spindle, M seal, Screws ,nailing , washers, check nuts, tightening of fittings of flushing cistern, cleaning of bottle traps etc to make it functional and stop leaking of any type of plumbing and sanitary items as in day to day maintenance work and fixing of new sanitary fittings (as bib taps, pillar taps, stop cockes, Seat cover, jet spray, cistern, mirror cabinet etc), complete all as specified.
81Attending the complaints of air lock from internal/ external side of GI pipes during supply hours (In early morning @ 6.00AM) & by taking down GI pipes and /or by using pressure pump in pipe where air lock occurred & resolve the complaint After refix the GI pipe in the same location, complete all as specified.
82Dismantling wrought iron or mild steel work of any description not otherwise provided for.
83M&L for Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290 Gd E-165 all as specified.
84S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc, complete all as specified.
85Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
86Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
87S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
88M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, complete all as specified and directed.
89M& L for taking down existing aluminium sliding window from aluminium frame carefully & refixing in the same position after replacing bearing wheels fixed at botom of shutter (02 Nos. in each shutter 1st quality) including all fittings , screws, etc, complete all as directed.
90Dismantling of safety net/ bird proofing mesh of any thickness and size fixed with steel frame work complete all as specified and directed.
91S&F HDPE safety netting to ceiling, dia of wire 1.4 to 1.8mm and size of mesh 20mm x 20mm fixed with 3mm dia GI Wire and cleat complete including tightening of wire netting etc complete all as specified and directed.
92S&F Glass Shelf Assembly (as approved) consisting of 5.5mm thick Sheet Glass Shelf 12 Cm Wide with Chromium Plated Bracket Guard and Railing 60 Cm long and Fixed-in-repairs, complete all as specified and as directed.
93Dismantling Single layer Mangalore pattern or similar tiles in roofing
94M & L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed
95Refixing for old serviceable Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed
96M & L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58545547
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.90 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/Maintainance Of Temp Accn Viz Barracks And Sheds Under Age B/R Ii Of Ge (Nw) Nofra.
Basic Detail
Tender No GE (NW) NOFRA 8616
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 16 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 49.90 Lakhs
Tender Fee 500
EMD 99800
Exemption Available
Document List
ae930a31-4713-4761-9f96-83028ebc271a.html
BOQ_896254.xls
Tendernotice_1.pdf
tenderpages8616.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

ae930a31-4713-4761-9f96-83028ebc271a.html

xls

BOQ_896254.xls

pdf

Tendernotice_1.pdf

pdf

tenderpages8616.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender