Tender for Improvements Of Water Supply System Inmarudur Town Panchayat,Karur District

BOQ

Name of Work:- Improvements of Water Supply System inMarudur Town Panchayat,Karur District
Sl. No. Item Description
1Supply,delivery of DI K7 S/S tyton joint pipes of 5.0m length for potable water supply as per IS specification no. 8329 /2000 and as amended from time to time with ISI marking of the following sizes and for delivery at site including loading, unloading, freight stacking, conveyance to the work site etc., complete as directed by the Engineer-in charge.
2100mm DI S/S K7 Class Pipe
3150mm DI S/S K7 Class Pipe
4200mm DI S/S K7 Class Pipe
5Supply of the following DI D/F PN10 pipes and specials as per IS specifications
6150mmx5m DI D/F pipe (Water Carrying)
7Supply, delivery of Ductile Iron Specials As Per IS 9523/2000 including unloading, transportation and stacking charges, conveyance to work site etc., complete as directed by the Engineer in charge.
8DI D/S Specials (100 mm to 200 mm)
9Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge.
1090mm HDPE PN6 Class Pipe
11110mm HDPE PN6 Class Pipe
12125mm HDPE PN6 Class Pipe
13140mm HDPE PN6 Class Pipe
14160mm HDPE PN6 Class Pipe
15180mm HDPE PN6 Class Pipe
16Supply, delivery of HDPE Specials As Per IS 1736-1995 including unloading, transportation and stacking charges.Specials for HDPE pipes as per IS 8360/1977/ Part I(Reaffirmed 1992) Part II and III (Reaffirmed 2002). Reaffirmed to IS 4984-2016 conveyance to work site etc., complete as directed by the Engineer in charge.
17HDPE Bends - 90° - PN6 Class
18110mm
19125mm
20140mm
21160mm
22HDPE Equal Tee - PN6 Class
2390mm x 90mm x 90mm
24110mm x 110mm x 110mm
25125mm x 125mm x 125mm
26140mm x 140mm x 140mm
27160mm x 160mm x 160mm
28HDPE PN6 Class Reducer
29110 mm X 90 mm HDPE Reducer
30125 mm X 90 mm HDPE Reducer
31125 mm X 110 mm HDPE Reducer
32140 mm X 90 mm HDPE Reducer
33140 mm X 110 mm HDPE Reducer
34140 mm X 125 mm HDPE Reducer
35160 mm X 90 mm HDPE Reducer
36160 mm X 110 mm HDPE Reducer
37160 mm X 125 mm HDPE Reducer
38160 mm X 140 mm HDPE Reducer
39180 mm X 90 mm HDPE Reducer
40180 mm X 110 mm HDPE Reducer
41180 mm X 125 mm HDPE Reducer
42180 mm X 140 mm HDPE Reducer
43180 mm X 160 mm HDPE Reducer
44HDPE End Cap
4590mm HDPE Endcap
46Supply of the following UPVC 6 KSC pipes and specials as per IS specifications for Cable
4750 MM UPVC 6 KSC pipe (Power Cable Cover Pipe)
48FLOW CONTROL VALVE:Supply, Installation of DI Flow rate Limit control Valve (PN10/16) with the function to limit the flow rate to a set point. In case the downstream demand increases beyond the set limit, the valve closes down to bring the flow back to set limit. The valve shall have an orifice plate and the orifice diameter is designed based on the set point as per the requirement and installed downstream of the control valve. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Flow rate Limit Control valve with cast body of ductile iron grade G-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent.
49Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as perKTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270. (EP-P)/ WRAS & NSF.”Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1, orifice plate shall be as per the set point of flow rate and all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing.
50DI D/F Gate Valve:Supply,Delivery and fixing of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years
51Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type,microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter
52offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled
53pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cumtransmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished
54Supply, delivery of Ductile Iron Specials as Per IS 9523/2000 including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying, jointing etc complete as directed by Engineer in Charge
55100mm Valve:
56For 110 mm Main valves arrangements comprising 100 mm Flow Control Valve, 100 mm DI D/F Gate Valve and 100 mm Electromagnetic Flow Meter upto 35 lps flow with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
57100 mm Dia DI Flanged Socket Tail Piece - 2 Nos
58100mm Dia DI D/F Pipe - 0.5 m length - 2 Nos
59100 m Dia DI D/F Gate Valve - 1 No
60100 mm Dia Flow Control Valve 1 No
61100 mm Electromagnetic Flow Meter - 1 No
62Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Officers.
63100 mm Dia DI pipes and Specials - 1 m
64Jointing the C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joints) including cost of lubricants. (including cost of jointing materials)
65100 mm Dia DI Pipes and Specials - 2 Nos.
66Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete. (including cost of jointing materials)
67100 mm dia DI pipes and specials - 6 Nos.
68Above 110 mm upto 160 mm Main valves arrangements comprising 100 mm Flow Control Valve, 150 mm DI D/F Gate Valve and 100 mm Electromagnetic Flow Meter upto 35 lps flow with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
69150 mm Dia DI Flanged Socket Tail Piece - 2 Nos
70150mm Dia DI D/F Pipe - 0.5 m length - 2 Nos
71150 m Dia DI D/F Gate Valve - 1 No
72150 mm X 100 mm Dia DI D/F Taper - 2Nos
73100 mm Dia Flow Control Valve 1 No
74100 mm Electromagnetic Flow Meter - 1 No
75Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Officers.
76150 mm Dia DI pipes and Specials - 1 m
77Jointing the C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joints) including cost of lubricants. (including cost of jointing materials)
78150 mm Dia DI Pipes and Specials - 2 Nos.
79Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete. (including cost of jointing materials)
80150 mm dia DI pipes and specials - 5 Nos.
81100 mm dia DI pipes and specials - 3 Nos.
82Pressure Relief Valve Arrangements
83DI Pressure Sustaining / Relief Valve (PN10/16) with the function to relieve excess pressure in the downstream pressure to set point irrespective of upstream fluctuations. The downstream pressure set point can be changed as per the requirement. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Sustaining / Relief valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/ WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.”Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 with all the external control tubing of SS 304/ Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing
84DI D/F Gate Valve:Supply,Delivery and fixing of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves areto be compatible for buried application with pressure rating PN 10/16 and with 5 years
85Supply, delivery of Ductile Iron Specials as Per IS 9523/2000 including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying, jointing etc complete as directed by Engineer in Charge
86For 110 mm Main valves arrangements comprising 100 mm DI D/F Gate Valve and 100 mm Pressure Relief Valve with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
87100 mm Dia DI Flanged Socket Tail Piece - 2 Nos
88100 mm Dia DI D/F Pipe - 1 m length - 2 Nos
89100 m Dia DI D/F Gate Valve - 1 No
90100 mm Pressure Relief Valve - 1 No
91100 mm DI D/F D'Foot bend - 1 No
92Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Officers.
93100 mm Dia DI pipes and Specials - 2 m
94Jointing the C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joints) including cost of lubricants. (including cost of jointing materials)
95100 mm Dia DI Pipes and Specials - 2 Nos.
96Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete. (including cost of jointing materials)
97100 mm dia DI pipes and specials - 7 Nos.
98DI D/F Gate Valve:Supply,Delivery and fixing of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years.
99Supply, delivery of Ductile Iron Specials as Per IS 9523/2000 including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying, jointing etc complete as directed by Engineer in Charge
10080 mm DI D/F Gate valve for Scour in 110 mm HDPE main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
101100 x 100 x 80 mm Branch Flanged Scour Tee - 1 No.
10280 mm x 1.00 m DI D/F Pipe - 2 Nos
10380 mm DI D/F Gate Valve - 1 No
10480 mm DI D/F D'Foot bend - 1 No
10580 mm DI D/F 90° bend - 1 No
106Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Officers.
10780 mm Dia DI pipes and Specials - 2 m
108Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete. (including cost of jointing materials)
10980 mm Dia DI pipes and Specials - 8 Nos.
110Supply and Delivery of DI D/F Gate valves (Soft Seated) resilient seated softsealing gate valves (sluice valves) with body bonnet of ductile cast iron of gradeGGG40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindlenut, without gland packing and with 3 O-Ring protection on the shaft and seals ofNBR and the valves should be of vaccum tight and 100% leak proof with face toface dimentions as EPR BS 5163-89/ ISI 14846-2000/ DIN 3202 F 4. All the valvesshould be with electrostatic powder coating both inside and outside with pocketless straight thro' body passage. All the valves are to be compatible for burriedapplication with pressure rating PN 10/16 and Supply, delivery of Ductile Iron Specials as Per IS 9523/2000 including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying, jointing etc complete as directed by Engineer in Charge
111DI D/F Gate Valves with Specials
112200 mm DI D/F Gate Valve PN 16 in 200mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
113200 mm DI D/F Gate Valve PN 16 - 1 No
114200 D.I.Flg /skt T.P. - 1 No
115200 D.I.Flg /spgt T.P. - 1 No
116Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 200 mm
117Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos - 200 mm
118DI D/F Gate Valve:Supply,Delivery and fixing of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years
119Supply, delivery of Ductile Iron Specials as Per IS 9523/2000 including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying, jointing etc complete as directed by Engineer in Charge
12080 mm DI D/F Gate valve for Scour in 100 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
121100 x 100 x 80 mm D.I. D/S B/F Tee - 1 No
12280 mm x 2.50 m D.I. D/F- 1 No
12380 mm x 1.0 m D.I. D/F Pipe - 2 Nos
12480 mm DI D/F Gate Valve - 1 No.
12580 mm D.I. D/f D'Foot bend - 1 No
12680 mm DI D/F 90˚ Bend - 2 No
127Surface box - 1 No.
128Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 8 Nos - 80 mm
129Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos - 100 mm
13080 mm DI Flanged / SPKT TP - 1 No
131Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 1 No - 80 mm
132100 mm DI D/F Gate valve for Scour in 200 mm DI main with fixing of DI Specials as per IS 9523/2000 including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
133200x 200 x100 mm D.I. D/S B/F Tee - 1 No
134100 mm x 2.50 m DI D/F Pipe.- 1 No
135100 mm x 1.00 m DI D/F Pipe - 2 Nos
136100 mm DI D/F Gate Valve - 1 No
137100 mm DI D/F D'Foot bend - 1 No
138100 mm x 1.5 m DI D/F Pipe - 1 No
139100 mm DI D/F 90˚ Bend - 2 No (1 No. - 12 Kg)
140C.I Surface box - 1 No
141Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 8 Nos - 100 mm
142Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. - 200mm
143Supply and Delivery of Tamper proof DI single chamber double orifice, triple function (ventilating, admitting and venting during operation) air release valves with pressure range from PN 1.0 to 2.5 with body and cover made of Ductile Iron of Grade GGG 40 or equivalent grade conforming to IS 1865 with Food Grade Epoxy Powder coating(EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years
144Supply, delivery of Ductile Iron Specials as Per IS 9523/2000 including unloading, transportation and stacking charges for fixing of valves with specials including labour charges for lowering, laying, jointing etc complete as directed by Engineer in Charge
14550 mm DI Single chamber Air release valve in 100 mm DI main with fixing of DI Specials as per IS 9523/2000 and GI Specials as per IS 1239/ Part II including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
146100 x 100 x 80 mm DI A / F Tee - 1 No
147100 mm DI Flanged Socket T.P. - 1 No
148100 mm DI Flanged Spigot T.P. - 1 No
14980 x 50 mm G.I. Reducer heavy - 1 No
15080 mm G.I. Flange - 1 Set
15150 mm G.I.Pipe - 0.15 m
15250 mm G.I. Flange - 1 set
153C.I Surface box - 1 No
15450 mm DI Single chamber Air release valve - 1 No
155Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 100 mm
156Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 80 mm
157Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 50 mm
158Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 1 No -100mm dia
15980 mm G.I.Pipe - 0.15 m
16050 mm DI Single chamber Air release valve in 200 mm DI main with fixing of DI Specials as per IS 9523/2000 and GI Specials as per IS 1239/ Part II including loading, transportation and Stacking Charges as per the following sizes as per the drawing, details of valves and specials as below
161200 x 200 x 80 mm DI A / F Tee - 1 No
162200 mm DI Flanged Socket T.P. - 2nos (1 No.- 20 kg)
16380 x 50 mm G.I. Reducer Heavy - 1 No
16480 mm G.I. Flange - 1 Set
16550 mm G.I.Pipe - 0.15 m
16650 mm G.I. Flange - 1 set
167C.I Surface box - 1 No
16850 mm DI Single chamber Air release valve - 1 No
169Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 2 Nos - 200 mm
170Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 80 mm
171Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete - 1 No - 50 mm
172Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials)- 2 Nos. -200mm
173Civil Works
174Earth work excavation and depositing on bank with an initial lead of 10m and initial lift of 2m inthe following classification including otherincidental charges such as barricading etcexcluding refilling in hard stiff clay,stiff blackcotton,hard red earth, shales, murram, gravel, stoneyearth and earth mixed with small size bouldersand hard gravelly soil complete as directed by the Engineer in Charges
175HDPE Pipes
17690mm HDPE PN6 Class Pipe
177110mm HDPE PN6 Class Pipe
178125mm HDPE PN6 Class Pipe
179140mm HDPE PN6 Class Pipe
180160mm HDPE PN6 Class Pipe
181180mm HDPE PN6 Class Pipe
182DI Pipes
183100mm DI S/S K7 Class Pipe
184150mm DI S/S K7 Class Pipe
185200mm DI S/S K7 Class Pipe
186150mmx5m DI D/F pipe (Water Carrying)
187Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth complete as directed by the Engineer--in-charge.
188HDPE Pipes
18990mm HDPE PN6 Class Pipe
190110mm HDPE PN6 Class Pipe
191125mm HDPE PN6 Class Pipe
192140mm HDPE PN6 Class Pipe
193160mm HDPE PN6 Class Pipe
194180mm HDPE PN6 Class Pipe
195DI Pipes
196100mm DI S/S K7 Class Pipe
197150mm DI S/S K7 Class Pipe
198200mm DI S/S K7 Class Pipe
199150mmx5m DI D/F pipe (Water Carrying)
200Lowering HDPE pipes and specials to trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Engineer in Charge.
201HDPE Pipes
20290mm HDPE PN6 Class Pipe
203110mm HDPE PN6 Class Pipe
204125mm HDPE PN6 Class Pipe
205140mm HDPE PN6 Class Pipe
206160mm HDPE PN6 Class Pipe
207180mm HDPE PN6 Class Pipe
208Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment complete as per standard specifications and as directed by the Engineer in Charge.
209DI Pipes
210100mm DI S/S K7 Class Pipe
211150mm DI S/S K7 Class Pipe
212200mm DI S/S K7 Class Pipe
213150mmx5m DI D/F pipe (Water Carrying)
214Lowering PVC/ DWSC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
21550 MM UPVC 6 KSC pipe (Power Cable Cover Pipe)
216Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Engineer in Charge.
217HDPE Pipes
21890mm HDPE PN6 Class Pipe
219110mm HDPE PN6 Class Pipe
220125mm HDPE PN6 Class Pipe
221140mm HDPE PN6 Class Pipe
222160mm HDPE PN6 Class Pipe
223180mm HDPE PN6 Class Pipe
224Jointing the DI S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants, cost of jointing materials and testing to the required pressure with water etc., complete as per standard specifications and as directed by the Engineer in Charge.
225DI Pipes
226100mm DI S/S K7 Class Pipe
227150mm DI S/S K7 Class Pipe
228200mm DI S/S K7 Class Pipe
229Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labourcharges etc., complete.
230150mmx5m DI D/F pipe (Water Carrying)
231P.C.C 1:2:4 (one cement, two sand and four coarse aggregate) using Ordinary Portland cement and 20 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Corporation Engineers.
232Plain Cement Concrete 1:5:10 (One Ordinary Portland Cement (OPC), Five fine aggregates and Ten coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
233Below GL upto 1.5 m Depth
234Below GL from 1.50 m upto 4.5 m Depth
235Testing of M.S. / C.I. / D.I / P.V.C. / H.D.P.E / pipes with hydraulic testing equipment by filling with waterand testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes.
236HDPE Pipes
23790mm HDPE PN6 Class Pipe
238110mm HDPE PN6 Class Pipe
239125mm HDPE PN6 Class Pipe
240140mm HDPE PN6 Class Pipe
241160mm HDPE PN6 Class Pipe
242180mm HDPE PN6 Class Pipe
243DI Pipes
244100mm DI S/S K7 Class Pipe
245150mm DI S/S K7 Class Pipe
246200mm DI S/S K7 Class Pipe
247150mmx5m DI D/F pipe (Water Carrying)
248Valve Chamber :Construction of masonry valve chamber:
249Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
250Plain Cement Concrete 1:4:8 using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
251Brick work in CM 1:5(one cement & five sand) using ground moulded country bricks of size 8.75 inch X 4.25 inch X 2 3/4 inch standard specification including finishing, curing, etc., complete complying with standard specification - 100cft
252Plastering with cement mortar (1:3) 12 mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309)
253RCC (M20) Precast Slab of 0.15m thickness using 20mm thick hard broken stone jelly and river sand excluding the cost of reinforcement grills and fabrication charges but including moulding, curing, finishing charges and fixing in position neatly complying with standard specification and as directed by the Departmental Engineer etc. complete-
254Supply and Fixing of Cut Stone Slab all faces dressed including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
255CI surface box at a of size 100x125x150 mm conforming to IS 3950 having hinged and weighting not less than 14 kg.The surface box shall be fixed on top of the RCC cover slab during the casting of slab for key rod operation. The surface box shall be painted with 3 coats of black bitumastic paint
256Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation complete as directed by the Engineer in charge
257Conveyance of excess earth to a distance not exceeding 5km as directed by the Corporation Engineer including cost of loading, transportation and unloading charges etc complete (Total Earthwork Quantity - Refilling Quantity)
258Valve Chamber Size 1 m x 1.3 m x 1.5 m
259Valve Chamber Size 1.2 m x 1.0 m x 1.2 m
260Valve Chamber Size 1.2 m x 0.9 m x 1.1 m
261Valve Chamber Size 2 m x 1.2 m x 1.2 m
262Valve Chamber Size 1.6 m x 1.1 m x 1.4 m
263Valve Chamber Size 2.0 m x 1.5 m x 1.3 m
264Disposal of surplus earth including loading & unloading, conveyance within a distance of 5 Km and spreading as directed by the Engineer in Charge. For Pipe Quantity and Road Restoration
265Labour charges for cutting open roads in BT / WBM for laying of water supply pipe line measurement
266Dismantling concrete roads for laying pipe line excluding cost of earth work in linear measurement
267BARRICADING FOR PIPELINE WORKS FOR THE WSS WORK: Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by the engineer in charge. Length of barricading (Less Traffic)
268BARRICADING FOR PIPELINE WORKS FOR THE WSS WORK: Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Departmental officers. Length of barricading (Heavy Traffic)
269Supply, delivery and fixing of enameled water level indicator of approved design and pattern (graduation in metric system) with required all accessories as directed by TWAD Board Officers. ( The rates including loading, unloading, transportation charges etc.,)
270Inlet Meter Arrangements in Existing OHT
271100 mm DI Flanged Socket - 2 No.
272100 mm DI D/F Gate Valve - 1 No.
273100 mm Electromagnetic Flow Meter - 1 No.
274Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete.
275Pipe Carrying Bridge 30m
276Pipe Carrying Bridge 50m
277Pipe Carrying Bridge and Pipe Arrangements
278Supply,delivery of DI PN10 Flanged pioes as per IS 8329/2000 and as amended from time to time with ISI marking of the following sizes and for delivery at site including loading, unloading, freight stacking, conveyance to the work site etc., complete as directed by the Engineer-in charge.
279200mm DI D/F PN10 5m Pipe - 29 Nos.
280200mm DI D/F PN10 3m Pipe - 8 Nos.
281200mm DI D/F PN10 1m Pipe - 2Nos
282Supply, delivery of Ductile Iron Specials As Per IS 9523/2000 including unloading, transportation and stacking charges, conveyance to work site etc., complete as directed by the Engineer in charge.
283200mm DI D/F Duckfoot Bend - 6 Nos.
284200 mm DI D/F Bend 90 Deg - 6 Nos.
285200 mm DI Flanged Socket Tail piece - 3 Nos.
286200 mm DI Flanged Spigot Tail Piece - 3 Nos.
287Lowering DI pipes to trench and laying to proper grade and alignment etc., complete and as directed by Engineer-in-charge.
288200mm DI D/F PN10 5m Pipe - 145m
289200mm DI D/F PN10 3m Pipe - 24m
290200mm DI D/F PN10 1m Pipe - 2m
291Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc.,complete.
292200 mm DI DI Pipes and Specials - 57 Nos.
293Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials)
294200 mm DI Spls - 6 Nos
295House Service Connection in Distribution Main
296HSC for HDPE Mains
2971.Labour for cutting open road for laying water mains or sewer.B.T. Roads (or) Maccadam road.
2982.Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply and sewerage works in the following type of soils Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil. as directed by Departmental officers
2993.Refilling with excavated soil (other than sand) complying with the standard specification for filling in foundation and basement (total earth work quantity - volume of the pipe)
3004.HSC Connection in HDPE Mains for Water Supply Scheme Supply, delivery of the following Electrofusion tapping saddle PE 80 blue, PN 12.5 with female threaded metal insert of SS 304 as per standards BS EN 12201 tested as per BS 6920 for drinking water in WRCNSF ltd, UK. (Non Wrap with top loading type). Sizes:63mm to 315mm dia distribution HDPE pipes. shall as detailed in a drawing furnished.
3015.Supply, delivery of Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS :554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm dia size ( 1/2\\", ) in the saddle Connection .as per IS :554 BSPT, ISO:7-1
3026.Supply, delivery of Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, OD MDPE pipes
3037.Supply, delivery of Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mmOD MDPE pipes
3048.Supply, delivery Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 20mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm respectively.
3059.Supply, delivery of MDPE PE 80 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK
30610.U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2\\"ID, 25mm ODX1/2\\"ID and 32mm OD X 3/4\\" ID
30711.Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1\\" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the Engineer in Charge.
30812.Supply and delivery of Multi Jet water meter with removal mechanism water meters confirming to ISO 4064 Class B or IS 779 Standards with type test certificates for Routine Test, IP 68 Test certificates issued by FCRI/NABL Accredited Lab. The water meter shall have magnetic or mechanical drivers or shall be versatile for installation in Horizontal position. The meters shall be hydrodynamically or hydrostatically balanced. The runner, runner chamber, pointers of the meter shall be as per ISO 4064 Class B specification. Dry dial excavated counter housing fully protected against flooding ensuring easy reading in all climatic conditions. The meters shall be inferential, Dry-Dial Type, Class B with straight reading Cyclometer with inbuilt filter basket, Meter body shall be of Brass body confirming to DCB2 material specifications and suitable for drinking water applications. The body shall be painted, or powder coated. Each water meter shall be supplied with Brass Nut and tailpieces, protective top lid, secured by a robust hinge with sealing facilities for couplings. The process connections shall be screwed ends with BSP Threads. Each water meter shall be tested for a maximum pressure rating up to 16 Bar. Water meter shall be supplied with manufacturer Calibration & hydrotest certificate. The dimensions must comply to IS 779 standards
30913.Lowering MDPE pipes and specials to the trench and laying to proper grade and alignment, jointing with couplers with cement past etc coplete for the pipes size upto 40mm dia OD MDPE Pipes
31014.Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Engineer in Charge.
31115.Supply, delivery and fixing of HDPE pipes for encasing in open drain including handling charges. etc complete as per standard specifications and as directed by the Engineer in Charge.
31216.Labour charges for drilling, cutting, Threading and Fixing Ferrules in distribution pipes.
313Earthwork excavation and depositing on bank for foundation, with an initial lead of 10m and initial lift of 2m including shoring, strutting and all other incidental works, as directed by the departmental Officers in the following classification of soil.
314Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders.
315First Depth of 0 - 2 m
3161 - 2 m depth
3172 - 3 m depth
3183 - 4 m depth
319Providing and laying in position Standardised Concrete Mix M-30 Grade using Ordinary Portland Cement in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 340Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without impairing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum)
3207670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the Engineer incharges - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials)
321Below GL upto 1.50 m Height
322Below GL 1.50 to 4.5 m depth
323Above GL Upto 4.5 m Depth
324Above GL 4.5 m to 7.32m Depth
325Above GL From 7.32 m to 10.98 m depth
326Above GL From 10.98 m to 14.64 m depth
327Above GL From 14.64 m to 18.30 m depth
328Above GL From 18.3 m to 21.96 m depth
329Providing Reinforcement Cement concrete (M20) 1:1½:3 (One cement one point five sand and three aggregates) mix using 20mm gauge hard granite broken stone jelly in all RCC works connected to the work excluding shuttering , Centering and cost of Reinforcement grills but including cost and conveyance of all materials and labour charges etc., complete as per standard specification
330Below GL Upto 1.5 m Height
331Above GL Upto 4.5 m Height
332Brick work in following Cement Mortar 1:5 using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
333Above GL upto 4.50 m:
334Supplying,fabricating and fixing of MS Grills with Doors and Window gate (5.00 mx 1.80 m) with one Coat of Red Oxide with primer including all costs such as welding, grinding, fabrication charges cost and Conveyance at all materials to site etc. complete as per Standard Specification.
335For Compound Wall
336Painting two coats with Ready Mixed Enamel Paint in MS Grill gate (5 mx 1.80) two sleeves over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all Grill Works.
337For Compound Wall
338Sinking of infiltration well of 4.50m internal dia and 5.40m external dia below water level including all incidental charges in light or sandy soil directed by the Engineers @ well curb including all labour charges etc, complete.
3391st Depth of 2m
3402nd Depth of 2m
3413rd Depth of 2m
3424th Depth of 2m
3435th Depth of 2m
3446th Depth of 2m
345Porous concrete in CC 1:4 (One cement and four hard broken granite jelly of a size 20mm) for steining of infiltration well excluding cost of centering but including curing etc., complete and as directed by the Engineers @ well curb including all labour charges etc, complete.
346For Infiltration Well
347Providing steel centering & shuttering with necessary strutting arrangements of sides and soffits for all RCC or PCC items including cost and conveyance of materials as directed by the Engineers @ well curb including all labour charges etc, complete.
348Plain Surface
3490 m - 3.30 m
3503.3 to 4.30m
3517.3 to 8.30m
35211.3 to 12.30m
35314.3 to 15.30m
35415.3 to 16.30m
355Curved Surface
3560 m to 3.30 m
3573.3 to 4.30m
35815.30 to 16.30m
359Square Column
3600 m to 3.30 m
3613.30 m to 4.30 m
3624.30 m to 5.30 m
3635.30 m to 6.30 m
3646.30 m to 7.30 m
3657.30 m to 8.30 m
3668.30 m to 9.30 m
3679.30 m to 10.30 m
36810.30 m to 11.30 m
36911.30 m to 12.30 m
37012.30 m to 13.30 m
37113.30 m to 14.30 m
37214.30 m to 15.30 m
37315.30 m to 16.30 m
374Circular Column
3750 to 3.30m
3763.30 to 4.30m
3774.30 to 5.30m
3785.30 to 6.30m
3796.30 to 7.30m
3807.30 to 8.30m
3818.30 to 9.30m
3829.30 to 10.30m
38310.30 to 11.30m
38411.30 to 12.30m
38512.30 to 13.30m
38613.30 to 14.30m
38714.30 to 15.30m
388Plastering with CM 1:5 ,12mm thick for outside walls complying with standard specification and as directed by the Departmental Officers.
389Special ceiling plastering with CM 1:3 mix 10mm thick complying with standard specification and as directed by the Departmental Officers.
390Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Ordinary Portland Cement (OPC) Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
391Weathering course with concrete broken brick jelly of 20mm size in pure slaked lime (No sand to be used) over roof slab the proportion of brick jelly to lime being 32:12.5 for required depth of 80mm for giving required slope and thickness to roof as required
392Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
393Supply and Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete.
394Fully panelled double leaf Door - D - 1.00 m x 2.00m
395For Sump - 1.00 LL Pump Room 4mx3m
396Fully panelled single leaf Ventilator - V -0.45 m x 0.60 m
397Supply, fabrication and placing in position of Steel, including Cutting, Bending & Therading including cost and conveyance of materials as directed by the Engineers @ well curb including all labour charges etc, complete.
398Refilling the sides of well with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
399Supplying and filling in foundation and basement with stone dust in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
400Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 60 X 60cm in size in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), of best approved quality and as per standard specifications etc.,complete.
401Supply and fixing of PVC Mould CI steps steps to be embedded in the wall of the infiltration well (inside) with vertical clearance of 0.30 m c/c and horizontal clearance of 0.38 mc/c in staggered manner etc. complete and as directed by Departmental officers.
402Supply and delivery of following sizes of FRC Manhole Covers with Frames 60 x 60 cm (Heavy duty)
403Providing for cutting edge using 12G MS sheets including the cost of fabricating welding and placing in position in the curb including supply of the MS sheet.
404Plugging the bottom of the well with coarse sand of approved sizes and grade as directed by the Board officers. Well curb triangular portion including all cost and conveyance of materials to site and all Labour charges etc, complete. (10 mm Stone).
405Providing cut stone slab size 0.45 m x 0.45 m x 0.15 m and as directed by officers
406Providing and fixing of RCC inner access ladder in M20 using 20mm HBG stone including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., to required height and clear width of 4Scm consisting of two Nos. of vertical post of 10cm x lScm and step slab of 2Smm x 25mm etc., complete and as directed by Dept officers.
407RCC Inside Ladder (4.65 m Height) - For Sump - 2.00 LL
408RCC Outside Ladder (2.30 m Height) - For Sump - 2.00 LL
409RCC Inside Ladder (5.50 m Height) - For Sump - 1.00 LL
410RCC Outside Ladder (2.30 m Height) - For Sump - 1.00 LL
411RCC Inside Ladder (3.65 m Height) - For 0.60LL OHT
412RCC Inside Ladder (3.30 m Height) - For 1.00LL OHT
413RCC Inside Ladder (3.20 m Height) - For 1.50LL OHT
414RCC Inside Ladder (4.00 m Height) - For 2.00LL OHT
415Construction of RCC spiral staircase in RCC 1:1.5:3 (1 Cement : 1.5 MSand : 3 Coarse Aggregate) using 20 mm HBGS of 1.80 m diameter of required height for approach to the roof of Service Reservoir with RCC Handrails including earthwork excavation, providing CC 1:4:8 mix, RCC footing 1:1.5:3 mix, GL platform etc., and also including cost of steel reinforcement, fabrication charges, scaffolding, centering, precasting charges, cement, painting etc. complete as per standard specifications and as directed by Engineer. The staircase shall be braced to the column of service reservoir at suitable interval.
416For 0.60 LL OHT
417For 1.00 LL OHT
418For 1.50 LL OHT
419For 2.00 LL OHT
420Providing and fixing of RCC 1:1.5:3 (one cement, one and half sand and three course aggregate of 20mm size hard blue granite broken stone) for ventilators of approved pattern including cost of cement, reinforcement, centering, shuttering, strutting etc., complete 0.15m dia
421Supply and fixing of M20 design mix RCC hand rails of 1m height over the top of the roof slab of approved pattern and design including the cost of cement, reinforcement, centering, precasting, finishing, curing cement painting the surfaces etc., complete and as directed by the departmental officers
422RCC Jolly Work
423RCC Post
424Providing GI ventilating arrangement of size 0.10m and as directed by the Engineer in Charge
425Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
426Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
427Painting the Town Panchayat Emblem and writing the slogon in accordance with size and specifications as approved by the Town Panchayat Officers with approved colour and quality of paint on the colour and quality of paint on the exterior surface of Service Reservoir complete etc., and as directed by Town Panchayath Officers.
428Supplying, Laying, jointing of following Pipe Connection for Overhead Tank as per IS- 1537/1976 (CLASS- B) VERTICAL CAST FOR PIPES AND IS-1538/1993 FOR SPECIALS etc.,Earthwork Excavation, Refilling, Lowering, Jointing, Lifting charges with necessary Gate Valves and Electromagnetic Flow Meter complete as directed by the Departmental Officers
429For 0.60 LL Overhead TankInlet ∅-100mmOutlet ∅-100mmOverflow ∅-100mmScour ∅-80mm
430For 1.00 LL Overhead TankInlet ∅-100mmOutlet ∅-125mmOverflow ∅-125mmScour ∅-80mm
431For 1.50 LL Overhead TanPInlet ∅-100mmOutlet ∅-150mmOverflow ∅-150mmScour ∅-80mm
432For 2.00 LL Overhead TankInlet ∅-150mmOutlet ∅-200mmOverflow ∅-200mmScour ∅-125mm
433Providing anchorage arrangements by drilling borewell using hand bore set to a dia of 4\\" inserting 110 MM PVC pipe, scooping of sand from the pipe and laying of concrete in PCC 1: 2: 4 including supply delivery and fixing of clamp sets to hold both water carrying and cable encasing pipe and earthwork excavation for a depth of 1.0 M before starting drilling of bore wells as per the details annexed
434DI D/F Pipes
435150mmx5m DI D/F pipe (Water Carrying) & 50 mm PVC Pipe (Cable Cover Pipe)
436Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP , Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation, complete as directed by Departmental Officers.
437Existing Infiltration Well (E.I.W-1) & Proposed Infiltration well - 700 LPM x 25 M - 6 HP Head (1S+1W) & Existing Infiltration Well (E.I.W-2) - 700 LPM x 30 M - 7 HP Head (1S+1W)
438Sump @ Headworks - 1457 LPM x 60 M - 29 HP (1S+1W)
439Intermediate Sump - 807 LPM x 60 M - 16 HP (1S+1W)
440Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately).
441Existing Infiltration Well (E.I.W-1) & Proposed Infiltration Well (P.I.W-1) - 700 LPM x 25 M - 6 HP Head (1S+1W
442Existing Infiltration Well (E.I.W-2) - 700 LPM x 30 M - 7 HP Head (1S+1W)
443Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc.
444Sump @ Headworks - 1457 LPM x 60 M - 29 HP (1S+1W)
445Intermediate Sump - 807 LPM x 60 M - 16 HP (1S+1W)
446Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415 / 440V 50 HZ conforming to ISS with ISI marking complete as directed by Departmental Officers.
447Supply and delivkery of 1.1 KV Grade 3 core/ 10 .Sq.mm.PVC insulated and steel armoured Aluminium cable as per IS 1554 to lay fromsupply point to panel board.
4483 Core 25 Sq.mm
4493 Core 16 Sq.mm
4503 Core 10 Sq.mm
451Laying the above cable as per IE rules between the supply point and LT panel Board
4523 Core 25 Sq.mm
4533 Core 16 Sq.mm
4543 Core 10 Sq.mm
455Jointing for all cable including the cost of jointing materials lugs, cable clamps etc, complete.
4563 Core 25 Sq.mm
4573 Core 16 Sq.mm
4583 Core 10 Sq.mm
459Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days complete and as directed by Departmental Officers.Above 5.00 HP to 10.00 HP
460Existing Infiltration Well (E.I.W-1) & Proposed Infiltration well - 700 LPM x 25 M - 6 HP Head (1S+1W) & Existing Infiltration Well (E.I.W-2) - 700 LPM x 30 M - 7 HP Head (1S+1W)
461Sump @ Headworks - 1457 LPM x 60 M - 29 HP (1S+1W) - Above 20.00 HP to 30.00 HP
462Intermediate Sump - 807 LPM x 60 M - 16 HP (1S+1W) - Above 10.00 HP to 20.00 HP
463Supply and Delivery of Horizontal Three Phase Distribution Board with MCBS 4 way / 6 way / 8 way / 12 way TPMCB sheet steel distribution boards Flush type / Surface type fitted with Bus bars and Neutral links with single/ three phase MCB outgoings and separate 4 way provision for accommodating one No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating one No. 4 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm. complete with Metal door cover with IP 42 protection as directed by TWAD Board Officers - Legrand (MDS)/ HAGER (L&T).
4644 ways 3 phase DBNo. of ways incomer MCB / Isolator - 4No. of ways incomer ELCB / RCD - 4No. of outgoings ways - 12
465MCB ISOLATORS 63 A - FP
46663 AMPS 30 MA ELCB (Four Pole - Higher End)
467Supply and delivery of Change over switches (GEM /HAVELLS / HPL/ STANDARD /EQUIVALENT) complete and as diected by Departmental Officers.63 Amps 3 phase 500 Volt 4 pole to the pumpset
468Supply and delivery of LT/LTCT METERING BOX as per IE rules and TANGEDCO norms complete as directed by Departmental Officers.Up to 50HP/37 KW (which includes LT meter panel board 6 Nos. suitable fuse carriers).
469Supply , delivery and fixing of GI/CI D/F pipes and specials for providing pipe connection for the pumpset, complete and as directed by Departmental Officers.
470150 mm dia DI D/F Pipe & Specials in Suction Side with 150 mm dia DI D/FDiameter Gate Valve, Reflux Valve with necessary Pipes & specials in Delivery Side in Pump Room of 250 mm dia DI D/F Pipe - Existing Infiltration Well (E.I.W-1) & Proposed Infiltration Well (P.I.W-1) - 700 LPM x 25 M - 6 HP Head (1S+1W)
471150 mm dia DI D/F Pipe & Specials in Suction Side with 150 mm dia DI D/FDiameter Gate Valve, Reflux Valve with necessary Pipes & specials in Delivery Side in Pump Room of 250 mm dia DI D/F Pipe - Proposed Infiltration Well (P.I.W-2) - 700 LPM x 30 M - 7 HP Head (1S+1W)
472150 mm dia DI D/F Pipe & Specials in Suction Side with 150 mm dia DI D/FDiameter Gate Valve, Reflux Valve with necessary Pipes & specials in Delivery Side in Pump Room of 250 mm dia DI D/F Pipe - Sump @ Headworks - 1457 LPM x 60 M - 29 HP (1S+1W)
473150 mm dia DI D/F Pipe & Specials in Suction Side with 150 mm dia DI D/FDiameter Gate Valve, Reflux Valve with necessary Pipes & specials in Delivery Side in Pump Room of 250 mm dia DI D/F Pipe - Intermediate Sump - 807 LPM x 60 M - 16 HP (1S+1W)
474Desilting light or sandysoil or silt from Existing Infiltration wells below water level including the charges for special T&P and air compressor etc. complete.
475Supply and delivery of 150mm dia Pressure Gauge and Vaccum guage including all accessories as per specification (For Suction and Delivery to be mounted on wall on Teak Wood Board) complete as directed by Departmental Officers. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58544406
AUTHORITY Local Bodies
TENDER VALUE 21.42 Crore
LAST DATE 15-12-2026
Authority
Authority Name Town Panchayats
Work Description Tender for Improvements Of Water Supply System Inmarudur Town Panchayat,Karur District
Basic Detail
Tender No 247/2026
Bidding Type Tender
Location
City Karur
State Tamil Nadu
Key Dates
Publish Date 16 Nov 2026
Submission Date 15 Dec 2026
Open Date 15 Dec 2026
Finance
Tender Value 21.42 Crore
Tender Fee Ref. Documents
EMD 21.42 Lakhs
Exemption Not Available
Document List
ae57086a-ba1c-4b96-bf2d-9408ec38c34a.html
BIDDOCUMENT.pdf
BOQ_872392.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 28 days
Dec 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

ae57086a-ba1c-4b96-bf2d-9408ec38c34a.html

pdf

BIDDOCUMENT.pdf

xls

BOQ_872392.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender