Housing Urban and Rular Development Government Departments Closing in 14 days TDR #58543515

Tender For Construction Of Auditorium Cum Examination Hall At Belpahar Higher Secondary School Building Belpahar In The District Of Jharsuguda

Issued by Government Departments · Jharsuguda, Odisha
Tender Value
1.24 Crore
Estimated cost
Bid Submission
01 Dec 2026
14 days left
EMD
1.24 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jharsuguda → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Auditorium Cum Examination Hall At Belpahar Higher Secondary School Building Belpahar In The District Of Jharsuguda

BOQ

Name of Work:- Construction of Auditorium cum Examination Hall at Belpahar Higher Secondary School building Belpahar in the district of Jharsuguda
Sl. No. Item Description
1Earthwork in excavation in all kind of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
2Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.
3Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only).
4Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
5Providing and laying plain cement concrete 1:2:4 (1 cement: 2 sand: 4 stone aggregate 12mm nominal size) as levelling course in foundation and plinth etc. and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
6Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.a) Footing
7Plinth beam
8lintel band
9Column
10Roof Beam
11Chajja
12Roof slab
13Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-Charge.(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor)Ground floor
14First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties
15Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-chargeGround floor
16Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with Portland slag cement (PSC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as per specification and direction of Engineer-in-charge.Ground floor
17Providing 16mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with Portland slag cement (PSC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as per specification and direction of Engineer-in-charge.Ground floor
18Providing 6 mm. thick cement plaster with cement mortar of mix (1:4) in all floors at all height with screened and washed sharp sand for mortar to ceiling plaster of roof slab, staircase, landings, chajja and shelves etc. including roughening, scraping, chiseling, cleaning closed deep chipping with slurry treatment and finished smooth to all R.C.C surface including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P , scaffolding, watering and curing etc. complete in all respect as per specification and direction of Engineer-in-charge.Ground floor
19Fixing Kota stone flooring using kota tiles of minimum 16mm thick and dimensional area above 0.10 sqm of approved quality make and shade as directed by Engineer-in-charge in floors, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects.GROUND FLOOR
20Fixing kota stone using kota tile of minimum 16mm thick and dimensional area 0.10 sqm as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects.GROUND FLOOR
21Supplying, fitting and fixing M.S. panalled door C.R. shutter door shutters and collapsible gate with top and bottom rails in proper position including making holes in walls in proper position including making holes in walls RCC structure and wood work etc. and making good to the damages to walls or RCC structures including mending, or cutting to sizes or grooves in walls and fixing with RCC (1:2:4) with hard black broken granite stone chips of 12mm to 20mm (1/2\\" to 3/4\\") (20mm not to exceed 25%) with cost, conveyane, royalty and taxes of all materials, labour, T & P articles requried for the work etc complete as per specification and direction of the EngineerinCharge
22Supplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators including cost of iron works and coaltaring 2 coats to the wall side faces of choukaths including cost of coal tar, cutting grooves and mending sizes where necessary with cost and conveyance, royalties and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors.
23Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete
24Manufacturing, supplying, fitting and fixing M.S. iron grill gate/ M.S. grills, grills made out of M.S.flat of 20mmx6mm & frame made out of of approved size M.S. angle iron of approved design as directed by Engineer-in-charge and placing in proper position including cost, conveyance, taxes with all labour and T&P required for the work etc. complete in all respect.
25Supplying fittings and fixing of two track UPVC sliding windows of approved make with 6mm thick glass of approved quality complete with frame ,shutter and all fiting and fixure with cost and conveyance, royalties and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors.
26Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, taxes of all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground floor
27Painting two coats with approved plastic emulsion paint of make Dulux / Berger / Asian to inside over a coat of primer surface of walls finished and finished smooth & even surface to receive painting using roller to the final coat including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use.Ground floor
28Painting two coats with approved anti-fungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of primer surface of walls finished and finished smooth & even surface to receive painting using roller to the final coat including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use.Ground floor
29Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge.
30Providing & Painting with synthetic enamel paint of approved brand and manufacture over a coat of primer to give an even shade as per the including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Ground floor instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete.Ground floor
31ELECTRICAL WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI or equievalant reputed make A catagory ISI marked as approved with 20 mm dia PVC flexible non metallic conduit FRLS type ISI marked Make-AKG/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrus) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrus) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approved of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for OFFICE. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A
32GROUP-B
33GROUP-C
34Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrus) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, complete suitable forOFFICE.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
35Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrus) /Panasonic (vision) or equievalant make & model ISI marked as approved , complete suitable forOFFICE.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 10 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
36Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrus)/Panasonic (vision)or equievalant reputed make A catagory ISI marked as approved, (For equipement power)All the switches & sockets should be warrantied for a replacement period of 10 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
372 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty flexible conduit (2X1.5+1X1.5)
382 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit. (2X2.5+1X1.5)
392 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit . (2X4+1X1.5)
402 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty flexible conduit . (2X6+1X2.5)
41S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
42Supplying,fixing of Blanking plate(modular type)( (anti bactorial & flame retradant type)) in existing switch box(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrus) /Panasonic (vision), complete suitable for OFFICE.It should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
43Supplying, installation, of exhaust fan of heavy duty 300 mm sweep (Make-Equievalant higher model with 3 star rated of Havells/almonard/Anchor/Panasonic/Usha or equievalant reputed make & model A catagory ISI marked as approved ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
44Supply,installation,testing & commissioning of 1 kva Online UPS complete with 2 x 12 V,100Ah SMF/Tubular batteries,battery rack,interconnecting cables and all accessories.
45Supplying and fixing of Energy efficient Recess mounted LED luminaire made up of CRCA powder coated sheet steel housing of 235 X 235 mm x 35 mm size with of not more than 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Trilux /Philips/Wipro or equievalant reputed make & model A catagory ISI marked as approved.) . The luminaire must be Replacement Warranty will be 5 years.
46Supplying and fixing of Energy efficient surface mounted square shape 20 W LED luminaire of dimension of 225x 225 x 35 mm consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 2000 lumens, , CRI not less than 100,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs warranty) and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. ( Make : Panasonic /Trilux/Osram/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved).The luminaire should be Replacement Warranty will be 5 years
47SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 5 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Similar to Panasonic/PHILIPS/LT/wipro or equievalant reputed make & model A catagory ISI marked as approved.). The luminaire should be Replacement Warranty will be 5 years .
48Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
49Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator)
502+4 way MCB Enclosure DB .
518 Way(8+24) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door.
52Supplying and fixing 20 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years .MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5 years.
53Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant reputed make & model A catagory ISI marked as approved. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years.MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5 years.
54Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA .Make-Equievalant higher model of Legrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
55Supplying and fixing 63Amps TPN 415 volts, MCB,10KA Make-Equievalant higher model of Legrand/Snheider/Siemens / L&T or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCB should be Replacement Warranty will be 5 years
56Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator)
57S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years
58P.H WORKSupplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge25mm dia PVC ASTM pipe (sch-80)
5932mm dia PVC ASTM pipe (sch-80)
60Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (FLR-ACR-5053N)
6115mm dia CP two in one bib cock (FLR-ACR-5041N)
6215mm dia CP Bib cock (Con-CHR-047KN Jaquar make)
6315mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
6420mm dia brass full way valve (Shakti make)
6525mm dia brass full way valve (Shakti make)
6632mm dia brass full way valve (Shakti make)
6740mm dia brass full way valve (Shakti make)
6850mm dia BFW Valve (Shakti make)
6915mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
70125mm CP grating
7115mm size C.P. flange
72Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank
73Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
74110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make)
75110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
76110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
77110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
78110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
79110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make)
80110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
81110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
82110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
83110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
84110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make)
85110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
86Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.580mm size Orissa pan (Hindware/Parryware/Neycer make)
87Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
88Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal
89Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-chargeEuropean water closet with 'p' trap plain(Hindware/Parryware/Neycer make)
90Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-chargeCounter basin(560x450)Hindware-No.10095
91Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail
92Towel ring
93Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails.
94Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type)
95Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
96Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
97Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
98Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
99Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge )Ceramic tile 60cmx60cm
100Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
101Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge )
102Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
103Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
104Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV with water storage capacity 120 liter's along with noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge
105Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge100mm dia P.V.C. pipe
106Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18 dia RCC Cover )
107Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
108Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm
109Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge32mm HDPE pipes (Finolex/Supreme make)
11020 Users septic tank of size 2.30m x 1.10m x 2.10m Internal sizeEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge.1 x 3.40 x 2.30 x 1.50 =
111Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. 1 x 3.40 x 2.30 x 0.60 =
112Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
113Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete.
114Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete.
115Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. 1 x 2.80 x 1.60 x 0.10 =
116Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. 0.448cum x 2.50x 35.32 = 39.55 kg say rs
117Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.
118Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site.
119Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site.
120Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. Same as plastering
121Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification.
122Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge.
123Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. 1 x 3.40 x 2.30 x 0.15 = Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58543515
AUTHORITY Government Departments
TENDER VALUE 1.24 Crore
LAST DATE 01-12-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Auditorium Cum Examination Hall At Belpahar Higher Secondary School Building Belpahar In The District Of Jharsuguda
Basic Detail
Tender No CCENC (R AND B)/05/2026-27
Bidding Type Tender
Location
City Jharsuguda
State Odisha
Key Dates
Publish Date 16 Nov 2026
Submission Date 01 Dec 2026
Open Date 02 Dec 2026
Finance
Tender Value 1.24 Crore
Tender Fee 10000
EMD 1.24 Lakhs
Exemption Available
Document List
BOQ_621040.xls
fc5bfd14-b308-417d-8aa0-4289dbbc465a.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_621040.xls

html

fc5bfd14-b308-417d-8aa0-4289dbbc465a.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender