Tender for Installation Of Musakata-Iv L.I. Projects Under Redhakhol Block In Sambalpur District Of L.I. Division, Sambalpur
BOQ
| Sl. No. | Item Description |
| 1 | Part-A |
| 2 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-in-charge. |
| 3 | Excavation in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical 60% & Manual 40%) |
| 4 | Filling in F&P with excavated materials including well watered and rammed.in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical plus manual ) |
| 5 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 6 | Cement concrete (1:4:8) with 4cm size h.g.b. crusher broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 7 | Brick work with K.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6)in foundation & plinth complete as per the Engineer-incharge |
| 8 | Brick work with K.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in super structure etc. complete as per the Engineer-incharge |
| 9 | Cement concrete (1:2:4) with 12mm size black h.g.b. crusher broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 10 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-inchargeRoof slab, chajja, carnice etc |
| 11 | Lintel |
| 12 | Plinth band, foundation, footing base of column etc |
| 13 | Beams & Columns |
| 14 | Walla & fins |
| 15 | Labour charges for MS reinforcement for RCC work including cutting, bending & tying the grills and placing in position including cost of binding wire 18 to 20 gauge & HYSD steel bar ( FE 415/ FE 500 ) |
| 16 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 17 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 18 | Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 19 | Dry brick rammed Khoa (10 cm) thick well watered and rammed. |
| 20 | 25mm thick AS flooring with CC (1:2:4) using 12mm sizeblack h.g.c.b chips of approved quality from approved quarry including watering and curing with cost, taxes, royality and conveyance charges of all materials to the work site and supply of all labour, T & P required for the work etc. complete |
| 21 | 2.5 cm thick grading concrete (1:2:2) with 6 cm size h.g chips |
| 22 | Cement washing two coats over plastering |
| 23 | Finishing walls with plastic emulsion paint of approved shade on new work two coat to give an even shade excluding cost of paint. |
| 24 | Wall painting two coats with weather coat paint of approved shade excluding cost of paint. |
| 25 | Cost of plastic emulsion paint |
| 26 | Cost of weather coat cement paint |
| 27 | Painting of red oxide primer of approved quality for priming over iron work including cost, taxes etc. complete |
| 28 | Painting of enamel paint of approved quality and colour for painting over iron work including cost, taxes etc. complete |
| 29 | MS panel door double leafed with MS frame overall size of 1.20x1.98 mtr for door and 0.90x0.90 mtr for window, shutter of 20 gauge CR sheet panel as per approved size and specification etc. including fitting & fixing the door etc. complete |
| 30 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 31 | Supplying all materials, labour, T&P for jointing of 160 mm outer dia High Density Polythylene Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge |
| 32 | Supplying all materials, labour, T&P for jointing of 200 mm outer dia High Density Polythylene Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge |
| 33 | Supplying of 160 mm dia PN - 4 PE - 80 HDPE Pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubanweswar, necessary approval of authority including transportation to work site in complete shape |
| 34 | Supplying of 200 mm dia PN - 4 PE - 80 HDPE Pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubanweswar, necessary approval of authority including transportation to work site in complete shape |
| 35 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. A) Hard Soil |
| 36 | Supplying & fitting of RCC ventilators |
| 37 | Centrifugal Monoblock pumpset total head of 28 mtr capable to discharge 1700 LPM with 15 HP/11 KW squirrel cage induction motor fitted with bronze impeller TB-2 of iS 318/1981, companion flanges & class 'F' insulation suitable for operation 415 volt + 6% - 15%, 3 phasde, 50 Hz aC power supply, delivery = 100x100 mm with BEE star rated energy efficiency pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership network for easy availibility of spares |
| 38 | Control panel with automatic star delta starter sheet steel enclosure vsuitable for operation of squirrel cage induction motor up to 15 HP with 16 Amp.(AC-3) duty contractor at 415 volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & No volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The starter should provide dependable protection against over load and single phasing fitted with Volt meter, Ammeter, MCB in complete shape including indicator lamp |
| 39 | Cost of 25 Amp -400 V.T.P. Main Switch confirming to IS No.4064 |
| 40 | 4 KVAR Capacitor |
| 41 | Motor Hood (size 0.45x0.45x0.60 mtr ) made with 18 SWG cold rolled mS sheet with one coat of red oxide primer and two coats of smoke gray / navy blue enamel paint both side (inside & outside) suitable to cover centrifugal monoblock Pump set from 10 to 15 HP and having provision for attachment with the groves on rear side of the panel board |
| 42 | Base Plate made of MS Channel with holes for Motor & Panel |
| 43 | 3 x 16 mm² Tarpedore cable XLPE ( cross link polyethylin ) confirming to IS: 7098 (Part-II) including laying below 0.90 mtr of the ground and filling the excavated materials including watering and ramming |
| 44 | 7/20 P.V.C. Wire |
| 45 | 100 mm dia nominal bore GI pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt - 1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS - 1239 (pt - II / 1992) with latest amendments in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturer's name/ trademark |
| 46 | 100 mm dia GI Bend IS No. 1239(pt-II/1992) |
| 47 | 100 mm dia GI flange IS No. 6392 / 1971 |
| 48 | 100x100x25 mm GI Tee with plug for priming |
| 49 | 100mm C.I. Foot Valve should be of swing type friction less with single disc confirming to iS - 4038/1979 of reputed brand |
| 50 | 100mm C.I. N.R. Valve double flanged swing type PN - 1.0 as per IS:5312 part - I with by-pass arrangement |
| 51 | 160 mm dia Butterfly valve as per IS - specification |
| 52 | 50 mm dia CI AR valve with saddle and riser pipe confirming to IS 14845 with ISI mark |
| 53 | 200x200x160 mm dia spigot moulded reducing HDPE Tee 10 kg |
| 54 | 200 x160 mm HDPE Reducer |
| 55 | 160 mm dia HDPE end cap |
| 56 | 200 mm dia HDPE end cap |
| 57 | 160x160x100 mm HDPE/GI Raiser tee set with bend closing and opening arrangement |
| 58 | 200 mm dia HDPE Tail piece 160 mm long |
| 59 | 200 mm dis MS pipe (Medium Duty ) 5.4 mm thick |
| 60 | 200 MM Dia MS Flange |
| 61 | Construction of out let for Tee Tank |
| 62 | Supply of small T & P Kit comprising of hand gloves - 1 pair, tester - 1 no, 8\\" cutting plier - 1 no, 12\\" sly wrench - 1 no, 12\\" screw driver - 1 no, 24/27 & 21/23 DE spanner - 2 nos, 24/27 & 21/23 Ring spanner - 2 nos of Taparia make |
| 63 | Labour charges for installation of 20 HP openwell submersible Motors including transportation from village to work site, fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, other fitting materials including cutting, welding etc. complete as per the direction of the Engineer-incharge. |
| 64 | Cost of Rubber Insertion and nut Bolt etc. |
| 65 | Labour charges for delivery and fitting including fitting of priming Tee, sluice Valve, NR Valve, air release valve and riser Tee etc and installation |
| 66 | Cost of river embankment cutting, cleaning ; fitting of suction & delivery fittings with flanges, bend, foot valve, sluice valve, NR valve etc including cost 1/8\\" rubber insertion, Nut nolt, white lead paint etc vomplete |
| 67 | Welding at site including supply of Welding machine, Generator set, all labour, materials and T & P |
| 68 | Part-B |
| 69 | Construction of 3 phase 3 wire 11 KV HT line as per REC standard confirming to RE Rules 1956 excluding 400 Kg. 10 Mtr. Long PSC pole support in 50 Mtr. Span.55sqmm Insulated covered AAA Conductor (190 kg/km) for elephant corridor area with double disc arrangement,11KV \\"V\\" cross arm with required nos. of 11 KV B & S disc. Insulators(120 KN) and 11KV pin insulators(70 KN), Padding & concreting of poles(1.5'X2'X3'),danger board at each pole, anticlimbing devices.Stay set at each bending point and double stay at end point with 18mm G.I. H.T. stay, concreting of stay with anchor plate etc. including cost of materials, labour, transportation, inspection & commissioning etc. complete including painting in Navy Blue colour band with inscription of OLIC in each Pole as per direction of Engineer-in-Charge. |
| 70 | Construction of 3 phase LT Line with 3x35+1x25mm² AB Cable(95kg/km.) excluding 300 Kg. 9 Mtr. Long PSC pole (30 mtr span) with required materials, piercing connector etc. including cost of materials, labour, transportation etc. complete including painting in Navy Blue colour band with inscriptionof OLIC in each Pole and cooping to be done at end pole and stay of end pole including Service connection distribution box as per direction of Engineer-in-Charge. |
| 71 | Construction & erection of 11/0.416 KV, 25 KVA (BIS level-II star 2) D.P mounted Sub-Station including transformer confirming to RE Rules,1956 mounted on 2.8 Mtr. Long structure, excluding 400 Kg. 10 Mtr. Long PSC pole,transformer mounting channel & top channel made 0f 2.8 Mtr. Long 100x50x6 mm M.S. channel, transformer belting on 2.8 Mtr. long 50 x 50 x 5 mm M.S. Angle(all REC.SPN. Std.F-3) with all accessories like 3 pole 11 KV HG Fuse (F-5) & A.B.Switches(400 Amp with ball bearing) (F-9) both mounted on 2.8M long 75x40x6 mm M.S. Channel and supported by 1.0 mtr. long 50x50x5 mm M.S. Angle with 3 nos. 11 KV lightening Arrestors and Distribution box for 63 KVA S/S, including cost of 35 sqmm 3.5 Core PVC cable carping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings. 05 nos FI Pipe Earthing 40 Dia Medium gage 3 mtrs in no 04 G.I wire and 01 no G.I Flat Earthing for Neutral along with L.T.Distribution box including 100 Amps Kit Kat fuse with MCCB (As per DISTCOM specification). Long,fixing of stay set with 0.5 Cum cement concret foundation 1:3:6 of required size , 3 1/2 x 35 sqmm. PVC Cable , , Bolts, Brackets, Cable sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing, inspection and commissioning including painting in Navy Blue colour band with inscription of OLIC in each Pole as per direction of Engineer-in-Charge. |
| 72 | 9 mtr long 300 kg PSC pole for HT line |
| 73 | 10 mtr 400 kg PSC pole for HT line (in elephant corridor area). |
| 74 | Materials for 11 KV line DP with AB switch(400 Amp. With ball bearing) without pole as per specification of DISTCOM. |
| 75 | Boundry wall of Sub-Station (size 15' x 10') with Sand filling and metal spreading, Fixing of Iron gril gate of double doors of 01 mt each to be fixed in proper size of briks. The gate is to be painted with silver coloured enamel paints and lock & key arrangements to be provided etc. as per the direction of the site engineer-in-charge. |
| 76 | Spike provisin on 10 mt long 400 kg PSC pole for elephant corridor area as per the direction of the site engineer-in-charge. |
| 77 | Electrical Pipe Earthing for Motor and Panel box of 40 mm dia Medium gage 3 mtrs using required quantity of common salt, charcoal , GI nut bolt including digging the earth pit of size 1.2mtr. X 1.2mtr.x3mtr. And digging the wire trench and refilling after completion of earthing including supply of all materials trnsportation etc. complete as per the direction of the site engineer-in-charge. |
| 78 | Internal wiring for Pump house as per instruction the direction of the site engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender