Tender For Revival And Energisation Of Balarampur-Ii R.L Project Under Athagada Block In Kataka District Under State-Plan 2026-27
Tender Value
6.34 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
6343
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuttack → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Revival And Energisation Of Balarampur-Ii R.L Project Under Athagada Block In Kataka District Under State-Plan 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete. |
| 2 | White wash two coats with shell lime |
| 3 | Labour charges for lowering & Instalation of 10HP submersible pump Sets including fitting and fixing of delivery pipe to motor,NR Valve, Sluice valve and other fitting materials including cutting, welding and etc. including transportation to project site and site clearance etc. complete as per the direction of the Engineer-incharge. |
| 4 | Fabrication of special joint including cutting and welding of pipes out of M.S. pipe / 100mm dia G.I.pipe including welding charges etc. complete. |
| 5 | Welding , Laying & fitting of 200 mm dia M.S. pipe including cutting & filling of river embankmentas per direction of Engineer-in-charge |
| 6 | Welding , Laying & fitting of 100 mm dia G.I. pipe including cutting & filling of river embankmentas per direction of Engineer-in-charge |
| 7 | 100mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 8 | 219mm dia M.S.Pipe (6.30mm thickness) IS 3589:2001 with ISI mark of reputed company including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022) |
| 9 | 100mm dia G.I.Bend ( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed company. |
| 10 | 100mm dia G.I.Flange ( Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed company. |
| 11 | Cost of 10 HP Submerssible Pumpset 900 LPM at head of 25 mtr including 2.5 sq mm ubmerssible flat cable 50 mtr. |
| 12 | 4 sqmm submersible (3 core) flat cable |
| 13 | 200x100 mm dia M.S. T/W cap |
| 14 | 100mm dia C.I.Double Flanged Non Return Valve swing type PN-1.0 (IS-5312(Part-I-2004) with bypass arrangement with ISI mark of reputed company. |
| 15 | 100mm dia C.I.Sluice Valve Flanged type PN-1.0 as per (IS-14846-2000 Standard) with ISI mark of reputed company. |
| 16 | 100 mm dia M.S, T/W Clamp (Pair) |
| 17 | 50MM Dia Air release valve with saddle &Raiser pipe.The air release valve shall confirm to IS14845 with ISImark including all taxes &royality etc. |
| 18 | 5/8 ' x3\\" Nut bolt F.T. |
| 19 | ⅛\\" thick Rubber Insertion |
| 20 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter, Ameter, MCB in complete shape including Indicator Lamp. |
| 21 | 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098(Pt-II) including cost of transportation to site. |
| 22 | Labour for drilling a perfectly vertical bore hole of specified diameter (minimum 400 mm dia.) for a specified depth below ground level in alluvial soil strata by mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer in charge including use of own Rigs with its accessories, tools and plants and all consumables (like coir rope, cotton waste and bentonite powder etc. complete) etc. for lowering of 200mm dia GI/PVC Pipe for housing fitted with sockets and with or without well screen as per the necessity for the soft medium, hard and boulder formations (. GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion ) including lower and withdrawing of casing pipes after drilling 200mm to 450mm dia in over burden portion.Drilling for 200 (8”) dia pipe: From 0 mtr. to 100th meters |
| 23 | Supply of all Labour & T&P for lowering the following sizes of PVC Pipes with or without slotted pipes as per the necessity from ground level & fitted & fixed up in perfectly verticaly position inlcuding cutting & threading pipe and slotted pipe and fixing all jointing materials etc. complete. and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fitting & joining materials.200mm dia PVC/GI Casing pipes |
| 24 | Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge. |
| 25 | Supplying all materials,Labour T & P for packing the bore with washed gravel size (P-6) arround the well screen and pipes in good quality including cost of gravel ,conveyance,royality,etc complete as per direction Engineer-in-charge. (50m depth) =0.786 x (0.4² - 0.2²) x 50mtr = 4.716 say 4.7 cum |
| 26 | Labour charges for cutting Transverse slot on 200 mm dia pvc pipe with slot size 1.5 mm as per specification |
| 27 | Threading charges |
| 28 | 8\\" PVC bail plug |
| 29 | 8\\" PVC threaded end cap PN-10 |
| 30 | 200mm x 12\\" long PVC shot piece |
| 31 | 200mm Ø Sch, 80 casing pipe Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender