Tender for Rep/Maint To Different B/R Misc Work At Stp Of Zone B And Rep/Maint And Repl Of Lt Panel Boards, Cables And Other Connected Works At Zonea Under Ge(I) Gos
BOQ
| Sl. No. | Item Description |
| 1 | List of works |
| 2 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 3 | M & L brick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar all as Specified and Directed |
| 4 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 6 | Supply only integral water proofing compound all as specified and directed. |
| 7 | M&L for preparation of newly plastered surfaces of wall applying two coat of white wash over a coat of primer all as specified and directed. |
| 8 | M&L for Preparation of old surfaces of Wall by brooming down or steel wire brushing, scraping down smoke soot, moulds, mass and efflorescent salts, trading oil and greasy spots etc and applying two coat of white wash over old decorated surface of walls all as specified and directed by Engineer-in-Charge. |
| 9 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new/old surfaces. |
| 10 | Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 12 | M&L for Non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 13 | M&L for glazed ceramic coloured tiles 300 x 200 x 7 mm / 450 x 350 x 7 mm thick coloured on vertical surface such as dado /skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 14 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons laid and pointed in any mortar etc. |
| 15 | M&L machine cut prepolished kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing upto Granite finish complete over 15mm thick screed bed in CM 1:6 all as specified |
| 16 | M&L for 20 mm thick granite (of any type & colour) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms/shelves incl screed bed 15 mm th. in CM (1:6) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 17 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 18 | Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 20mm bore of pipe complete all as specified and directed. |
| 19 | Supplying and laying of 20mm bore dia, CPVC pipes SDR 11 & plain and brass CPVC SDR 11 fittings, fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed. |
| 20 | S&F in repair bib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed. |
| 21 | Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete,PVC ) set in cement mortar for any size & type complete all as specified and directed. |
| 22 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 23 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 24 | S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed. |
| 25 | S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed. |
| 26 | Providing and laying 60mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified. |
| 27 | M& L for vitrified parking tiles of size 300mm x 300mm x 10mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment incl 20mm thick screed bed in cm 1:4 complete all as specified and directed. |
| 28 | M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 29 | M&L for 50 mm thick Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring incl finished cement concrete surface even and smooth complete all as specified and directed. |
| 30 | M&L for Chequered cement concrete tiles of size 200 mm x 200 mm x 25 mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 31 | Dismantling of AC/GI plain/Corrugated / semi corrugated roof sheets any type and any size complete all as specified and directed. |
| 32 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 33 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engineer-in-Charge. |
| 34 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 35 | S&F Mild steel work in tubular poles & trusses (framed) including purlins,rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Dismantling chain link fencing wire mess of any type |
| 37 | Dismantling posts and struts (wood, steel or RCC) any section, including taking out embeded portion in Concrete, brickwork and masonary and making good disturb ground complete |
| 38 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 39 | M&L for PCC 1;4;8 type D 2 (using 40 mm graded stone aggregate) as in foundations, filling and mass-concrete |
| 40 | S&F MS work as in angle iron fencing posts & struts thick for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to IS-15911-2010. |
| 41 | S&F in repair galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of stanadard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed. |
| 42 | S&F flat iron as in fastening of chain link fencing fixed to nuts and bolts including holes complete |
| 43 | Providing reinforced cement concrete type B-1, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm, not exc 250Sqcm with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed. |
| 44 | S&F PVC insulated chain link fencing including line wire of size 3.25mm dia and 100 x 100 mm mesh size made up in mattresses or cases, lapped wire and laid in position to RCC fencing and straining and fixing to any type of posts , straining bolts, standard bolts, incl securing or tying at crossing with and incl provision of galvanised mild steel wire sraples or steel pins etc complete all as specified and directed (each line of wire to be measured for the purpose of payment) |
| 45 | S&F MS round bars, Mild steel , round or square bars, in available lengths in IS-15911-2010. |
| 46 | M&L Mild steel bolts machine made having 20mm dia shank , n.exc 10 CM long , Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers,the other end enlarged, and jagged or lewised, n exc 15cm long |
| 47 | M & L for precast RCC 1:2:4 type B-1(using 20mm graded stone aggregate)for manhole cover including placing and set and providing necessary arrangement for handles in CM 1:4 all as specified |
| 48 | M & L mild steel deformed or twisted bar(TMT bar)10mm dia and cover cut to length bent to shape reqd, incl, cranking benching spirally for copying for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia. |
| 49 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 50 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge |
| 51 | S&F Sign board made out of PGI sheet 1 mm thick fixed with transparent/coloured PVC acrylic sheet cover of thickness 2.5 mm printed with letters, logo and digits of approx size 25 x 10 cm of colour as directed (Appx 50 Nos) as directed, using necessary fixing arrangements viz clamps, nuts, bolts and washers and welding , excavation and PCC work all as specified and directed. Note :1. Size of sign board and colour will be decided by the department as per the site requirement.2. SS Pole shall be used for fixing of sign shall only be measured and paid separatelyunder relevant item of Sch 'A'. Remaining items are deemed to be inclusive in the item rate. |
| 52 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and including fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor, brickwork, PCC or the side of waist slab with suitable arrangement complete all as specified and directed . |
| 53 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 54 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 55 | Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 56 | Supply and laying double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified |
| 57 | Supply and laying double wall corrugated HDPE pipe 63 mm outer dia for protection of UG cable complete all as specified |
| 58 | Supply and laying double wall corrugated HDPE pipe 80mm outer dia for protection of UG cable complete all as specified |
| 59 | Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes complete, all as specified and directed :-(a)10 Sqmm 2 Core |
| 60 | (b)All as per item no 59 but for 10 Sqmm 4 Core. |
| 61 | (c)All as per item no 59 but for 16 Sqmm 4 Core. |
| 62 | (d)All as per item no 59 but for 25 Sqmm 3.5 Core. |
| 63 | (e)All as per item no 59 but for 35 Sqmm 3.5 Core |
| 64 | (f)All as per item no 59 but for 50 Sqmm 3.5 Core |
| 65 | (g)All as per item no 59 but for 70 Sqmm 3.5 Core |
| 66 | (h)All as per item no 59 but for 95 Sqmm 3.5 Core |
| 67 | (j) All as per item no 59 but for 120 Sqmm 3.5 Core |
| 68 | (k)All as per item no 59 but for 150 Sqmm 3.5 Core |
| 69 | (m) All as per item no 59 but for 240 Sqmm 3.5 Core |
| 70 | M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 71 | Supply and fixing of moulded case circuit breaker Four pole 100/63Amps 15 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge |
| 72 | Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 73 | Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge |
| 74 | Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 75 | Supply and fixing of moulded case circuit breaker Four pole 320 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 76 | Supply and fixing of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 77 | Supply and fixing of moulded case circuit breaker Four pole 630 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge |
| 78 | Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed. |
| 79 | Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed. |
| 80 | Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and directed. |
| 81 | Supply and fixing selector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete all as specified and directed. |
| 82 | Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed. |
| 83 | M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the panels protection of MCCB's and MCB's to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor. |
| 84 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 6-16 sqmm complete |
| 85 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16-50 sqmm complete |
| 86 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete |
| 87 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete |
| 88 | Supply and fixing Aluminium tube terminal/ lugs of undermentioned size complete (a) 10 to 25 Sqmm |
| 89 | (b)All as per item no 88 but for 35 to 50 Sqmm |
| 90 | (c) All as per item no 88 but fo 70 to 120 Sqmm |
| 91 | (d) All as per item no 88 but fo 150 to 185 Sqmm |
| 92 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level with one meter wide plaform in all round panel LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following.(i) MCCB 630 A FP, 50 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming) (ii)MCCB 250A FP, 36 KA, Adjustable thermal & Fixed magnetic setting. 01 Nos. (Outgoing) (iii)MCCB 100A FP, 16 KA, Adjustable thermal & Fixed magnetic setting. 07 Nos. (Outgoing) (iv)Alumimium bus bars sleeve insulated 25X 10 mm TPN mounted on epoxy insulators-01 Set(v)Digital voltmeter 0 - 500 V range with selector switch - 01 No(vi)Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No(vii) Indicators RYB - 01 Set(viiiInternal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(ix)Cable entry glands and two nos earthing terminals(x) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick(xi) Cost of PCC, eraction incl commission etc complete |
| 93 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level. LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following.(i)ACB 800 Amp FP, 75 KA, LSIG Protection with microprocessor at variable time delay,digital display of current,energy,power factor and voltage parameters Range- 400 Amp- 6300A &Icu=Ics=Icw(1s) up to 756 KA @500 Vac-, 3P, 3P+N &4P,Fixed type and Draw out type - 1 Nos. (Incoming) (ii)MCCB 100A FP, 25 KA, Adjustable thermal & Fixed magnetic setting. 14 Nos. (Outgoing)(iii)MCCB 200A FP, 25 KA, Adjustable thermal & Fixed magnetic setting. 02 Nos. (Outgoing)(iv)MCCB 250A FP, 25 KA, Adjustable thermal & Fixed magnetic setting. 01 Nos. (Outgoing)(v)Alumimium bus bars sleeve insulated 25X10mm TPN mounted on epoxy insulators-01 Set(vi) Digital voltmeter 0 - 500 V range with selector switch - 01 No(vii)Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No(viii)Indicators RYB - 01 Set(ix)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(x)Cable entry glands and two nos earthing terminals(xi) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick(xii) Cost of PCC, eraction incl commission etc complete |
| 94 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level. LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following.(i)MCCB 200 A FP, 36 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming) (ii)MCCB 100A FP, 25 KA, Adjustable thermal & Fixed magnetic setting. 2 Nos. (Outgoing)(iii)MCCB 160A FP, 25 KA, Adjustable thermal & Fixed magnetic setting. 1 Nos. (Outgoing)(iv)MCB TPN 63 A -04 Nos(v)MCB SPN 40 A, -06 Nos(vi)Alumimium bus bars sleeve insulated 25X10mm TPN mounted on epoxy insulators-01 Set(vii)Digital voltmeter 0 - 500 V range with selector switch - 01 No(viii)Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No(ix) Indicators RYB - 01 Set(x)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(xi)Cable entry glands and two nos earthing terminals(xii) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick(xiii) Cost of PCC, eraction incl commission etc complete |
| 95 | Supply, fabricate, erect, test and commission in replacement outdoor LT Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet with front and back done openable, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etc as required with and including the following, supplied fitted and connected internally complete 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators, moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with 250 Amp MCCB with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In complete all as specified |
| 96 | Supply and fix in replacement of Timer panel, made of MS Enclosure factory made consisting Astronomical timer with max load of 12 KW with 65 A TP contactor with MCB 63 Amp TPN three phase 415 volts conforming to IS/IEC 60947-4-1, provided with protection degree IP 54 with internal wiring FRLS copper cable, in built shor-circuit-protection, class H insulation complete as as specifed and directed. with suitable size of angle iron frame and necessary PCC Wk all as specified and as directed by Engr-n-charge |
| 97 | M&L for attending day to day breakdown complaints of any nature in low tension line after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible complete all as specified and directed. Note : If any major materials are used will be measured and paid separately in appropriate items above. |
| 98 | Taking out old UNSV XLPE/PVC insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor from trenches, from poles/walls etc cross sectional area for following sizes complete, all as specified and directed :-(Excavation/Earth wk will be measured and paid seperately) (a) 10 Sqmm to 16 sqmm 4 / 2 Core |
| 99 | (b) All as per item no 98 but for 25 to 70 Sqmm 3.5 Core/4 core. |
| 100 | (c) All as per item no 98 but for 95 to 240 Sqmm 3.5 Core/4 core. |
| 101 | Relaying of serviceable U/G cable retrived from site of size 10 to 16 sqmm 2/4 core ( Cable protection pipe /sand brick,jointing kit,cable lugs etc will be measured and paid seperately) |
| 102 | Relaying of serviceable U/G cable retrived from site of size 25 to 35 sqmm 2/3.5/4 core ( Cable protection pipe /sand brick,jointing kit, cable lugs,etc will be measured and paid seperately) |
| 103 | Relaying of serviceable U/G cable retrived from site of size 50 to 240 sqmm 2/3.5/4 core ( Cable protection pipe /sand brick,jointing kit, cable lugs etc will be measured and paid seperately) |
| 104 | S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :-(a) 100 mm dia |
| 105 | All as per item no 104 but for 50 mm Dia |
| 106 | All as per item no 104 but for 80 mm Dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender