Tender For Construction Of Office Building And Residential Staff Quarter Of Pbda, Banspal In Banspal Block.
Tender Value
4.14 Crore
Estimated cost
Bid Submission
01 Dec 2026
12 days left
EMD
4.14 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kendujhar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Office Building And Residential Staff Quarter Of Pbda, Banspal In Banspal Block.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 3 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 4 | Supplying of filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-Charge. |
| 5 | Disposal of surplus exccavated materials by mechanical means from the work side etc complete upto 5km lead. |
| 6 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. |
| 7 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 8 | Office building |
| 9 | Staff quarter |
| 10 | Boundary wall |
| 11 | Soak pit |
| 12 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 13 | G.Floor-Foundation & plinth |
| 14 | Coloumn & Beam |
| 15 | Plinth Beam |
| 16 | Chajja |
| 17 | Platfrom & shelves |
| 18 | Staircase |
| 19 | 1st Floor-Coloumn & Roof Beam |
| 20 | Staircase |
| 21 | Chajja |
| 22 | Platform & Shelves |
| 23 | Terrace Floor-Column & Beam |
| 24 | Roof Slab-Ground floor |
| 25 | First floor |
| 26 | Terrace floor |
| 27 | Lintle/Sill-Ground floor |
| 28 | First floor |
| 29 | Terrace floor |
| 30 | New Building ( Staff quarter )-G.Floor-Foundation & plinth |
| 31 | Column & Beam |
| 32 | Plinth Beam |
| 33 | Staircase |
| 34 | Chajja |
| 35 | Platform & Shelves |
| 36 | Staircase |
| 37 | Chajja |
| 38 | Platform & Shelves |
| 39 | Second floor- Column & Beam |
| 40 | Staircase |
| 41 | Chajja |
| 42 | Platform & Shelves |
| 43 | Terrace Floor-Column & Beam |
| 44 | Roof Slab-Ground floor |
| 45 | First floor |
| 46 | Second floor |
| 47 | Terrace floor |
| 48 | Lintel/Sill-Ground floor |
| 49 | First floor |
| 50 | Second floor |
| 51 | Terrace floor |
| 52 | RCC Wall (Septic tank) |
| 53 | Cutting,straightening coiled or bent up HYSD/TMT 550D Reinforcement Bars confirming to IS 1786:2008 welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved designs and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only) |
| 54 | Ground floor (office building) |
| 55 | First Floor (office building) |
| 56 | Terrace Floor (office building) |
| 57 | First Floor (Staff quarter) |
| 58 | Second Floor (Staff quarter) |
| 59 | Terrace Floor (Staff quarter) |
| 60 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 61 | Office building-Ground Floor |
| 62 | First Floor |
| 63 | Terrace Floor |
| 64 | Staff Quarter-Ground Floor |
| 65 | First Floor |
| 66 | Second Floor |
| 67 | Terrace Floor |
| 68 | Boundary wall |
| 69 | Ground floor (Office building) |
| 70 | Ground floor ( Staff quarter ) |
| 71 | First floor (Office building) |
| 72 | First Floor( Staff quarter ) |
| 73 | Second Floor(Staff quarter) |
| 74 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. (External wall) |
| 75 | New Building (Office Building)-Ground floor (Office building) |
| 76 | Ground floor ( Staff quarter ) |
| 77 | Boundary wall |
| 78 | First floor (Office building) |
| 79 | First Floor( Staff quarter ) |
| 80 | Terrace floor (office building) |
| 81 | Second Floor(Staff quarter) |
| 82 | Saptic |
| 83 | Terrace floor (Staff quarter) |
| 84 | Septic tank |
| 85 | Providing 12mm thick CP with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing rounding of corners providing grooves where ever necessary with cost, conveyance, royalties with cost of all labour, labour cess, T&P and scaffolding required for the work etc complete in all respect and specification and direction of the Engineer in charge. (Internal wall) |
| 86 | New Building (office building )-Ground Floor |
| 87 | First Floor |
| 88 | New Building ( Staff quarter )-Ground floor |
| 89 | First Floor |
| 90 | Second Floor |
| 91 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing, rounding of corners etc. complete with cost,conveyance,loading, unloading, royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge. |
| 92 | New Building (office building )-Ground Floor |
| 93 | First Floor |
| 94 | Terrace Floor |
| 95 | New Building ( Staff quarter )-Ground floor |
| 96 | First Floor |
| 97 | Second Floor |
| 98 | Terrace Floor |
| 99 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 100 | New Building (office building )-Ground Floor |
| 101 | First Floor |
| 102 | Drain |
| 103 | New Building ( Staff quarter )-Ground floor |
| 104 | First Floor |
| 105 | Second Floor |
| 106 | Cement punning on plastered surface |
| 107 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 108 | New Building (office building )-Ground Floor |
| 109 | First Floor |
| 110 | Terrace Floor |
| 111 | New Building ( Staff quarter )-Ground floor |
| 112 | First Floor |
| 113 | Second Floor |
| 114 | Terrace Floor |
| 115 | Priming one coat with water bound wall primer. |
| 116 | New Building (office building )-Ground Floor |
| 117 | First Floor |
| 118 | Terrace Floor |
| 119 | New Building ( Staff quarter )-Ground floor |
| 120 | First Floor |
| 121 | Second Floor |
| 122 | Terrace Floor |
| 123 | Boundary wall |
| 124 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade |
| 125 | New Building (office building )-Ground Floor |
| 126 | First Floor |
| 127 | Terrace Floor |
| 128 | New Building ( Staff quarter )-Ground floor |
| 129 | First Floor |
| 130 | Second Floor |
| 131 | Terrace Floor |
| 132 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 133 | New Building (office building )-Ground Floor |
| 134 | First Floor |
| 135 | Terrace Floor |
| 136 | Boundary wall |
| 137 | New Building ( Staff quarter )-Ground floor |
| 138 | First Floor |
| 139 | Second Floor |
| 140 | Terrace Floor |
| 141 | Supplying , providing & laying double charge mat finished vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 800mm x 800mm of premium quality in floors treads on steps and landins on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to amtch the shades of the vitrified tile i required watering and curing for 21 days including cost, conveyance, loading unloading royalties and taxes of all materials cost of all labour, labour cess sundries T&P required for the work complete in all respect as per spoecification and direction of Engineer-in-charge. |
| 142 | New Building (office building )-Ground Floor |
| 143 | First Floor |
| 144 | New Building ( Staff quarter )-Ground floor |
| 145 | First Floor |
| 146 | Second Floor |
| 147 | Supplying, fitting & fixing of double charged vitrified wall tiles 800mm x 800mm in dados/skirting of approved make laid on 12mm thick cement mortar (1:3) (1 cement 3 course sand) and filling joints with slurry including cost of all materials labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. |
| 148 | New Building (office building )-Ground Floor |
| 149 | First Floor |
| 150 | New Building ( Staff quarter )-Ground floor |
| 151 | First Floor |
| 152 | Second Floor |
| 153 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes,rubbing, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge. |
| 154 | New Building (office building )-Ground Floor |
| 155 | First Floor |
| 156 | New Building ( Staff quarter )-Ground floor |
| 157 | First Floor |
| 158 | Second Floor |
| 159 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 160 | New Building (office building )-Ground Floor |
| 161 | First Floor |
| 162 | New Building ( Staff quarter )-Ground floor |
| 163 | First Floor |
| 164 | Second Floor |
| 165 | Providing and fixing of Aluminium Sliding window with Acrylic Sheet |
| 166 | New Building (office building ) |
| 167 | New Building ( Staff quarter ) |
| 168 | Providing and fixing of Aluminium Ventilator with Acrylic sheet louver |
| 169 | New Building (office building ) |
| 170 | New Building ( Staff quarter ) |
| 171 | Providing & fixing of dressed seasoned sal wood Door choukath including all labour, material, fitting & fixtures etc all comlete as per direction of EIC |
| 172 | New Building (office building ) |
| 173 | New Building ( Staff quarter ) |
| 174 | Providing & fixing ISI marked 35mm thick Flush door shutter confirming to IS:2202 (Part I), decorative type core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc complete. |
| 175 | New Building (office building ) |
| 176 | New Building ( Staff quarter ) |
| 177 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Graphite grey colour) comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. ( Frame size 62 x 100 mm) (Make: Century /Floresta/ ALSTONE) |
| 178 | New Building (office building ) |
| 179 | New Building ( Staff quarter ) |
| 180 | Providing & fixing 30mm thick factory made single extruded WPC Solid Plain Flush Door shutter of required size comprising of virgin polymer of K Valus 58-60 calcium carbonate and natural fibers and non toxic additives having minimum density of 650kg/cum and screw withdrawal strength 1800N & 900N minimum compressive strength 50N/MM2 modulus of elasticity 850N/MM2 and resistence to spread of flame of class A category with property of being termite / borer proof water moisture roof and fire retandant and fixing with stainless steel butt hinges of required size with necessary fullbody threaded star headed counter sunk SS screws all as per direction of Engineer-in-charge (Make:Century /Florestal/ALSTONE) |
| 181 | New Building (office building ) |
| 182 | New Building ( Staff quarter ) |
| 183 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat conforming to IS 2062/2006 excluding the cost of Red Oxide Primer as per the design approve by E.I.C including cost, conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 184 | New Building (office building ) |
| 185 | New Building ( Staff quarter ) |
| 186 | Boundary wall |
| 187 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 188 | New Building ( office building )-Ground Floor |
| 189 | First Floor |
| 190 | Terrace Floor |
| 191 | New Building ( Staff quarter )-Ground Floor |
| 192 | First Floor |
| 193 | Second Floor |
| 194 | Terrace Floor |
| 195 | Boundary wall |
| 196 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 197 | New Building (office building ) |
| 198 | New Building ( Staff quarter ) |
| 199 | 20mm thick Grading Plaster |
| 200 | New Building ( office building ) |
| 201 | New Building ( Staff quarter ) |
| 202 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m complete as per direction of Engineer-in-charge. |
| 203 | New Building ( office building ) |
| 204 | New Building ( Staff quarter ) |
| 205 | Supplying and Fixing of Elastomeric membrane of 200 x 2mm size for expansion joint sealing from approved manufacturer fixing with epoxy adhesive of approved quality complete |
| 206 | Providing and laying approved colour 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 75mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge. |
| 207 | BORE WELL Labour for drinlling a perfectly vertical bore hole of 200mm(8\\") dia for a specified depth below ground level inall kinds of soil by DTH/ODEX rig so as to lower the G.I/PVC casing pipes of 200mm dia fitted with or without socket as the case may be as per direction of Engineering-in-charge incluiding deployment of DTH/ODEX rig with its accessories , T&P and all consumables etc. all complete. 200MM DIA 0 to 200 mtrs (DTH) (Video PHD S/R P-61 Item no.5.2.1) |
| 208 | Labour for lowerring the followng size of ms/pvc casing pipe with or without slotted pipes as per necessity form ground level & fixed perfectly vertical position incluiding pluging the tube well prevent entry of foreign materials from above0 to 200 Mtrs (Video PHD S/R P-80 Item NO.11 SCh .80) |
| 209 | Cost of 200mm dia 0 to 65 mtrs (Video PHD S/R P-61 Item NO.5.2.2) |
| 210 | Clearing and developing of the T.Well with their own compressor countinuously worked for 2 hours till clear and adequate discharge is obtained with supply of T&P , all equipments etc. |
| 211 | Cost of submerssible Pump (1HP) |
| 212 | Labour Charges for lowerig of submerssible Pump etc. alla completed |
| 213 | Cost of 4.0 sqm Copper Cable |
| 214 | Cost of Pannel Board with all set |
| 215 | Cost of Clamp |
| 216 | Cost of HDPE pipe 25mm dia |
| 217 | 25mm dia PVC Pipe |
| 218 | 25mm dia Fullway valve |
| 219 | supplying and fitting Pvc tap |
| 220 | cost of nylone rope |
| 221 | cost of G.I fitting etc all compelete |
| 222 | supplying fitting and fixing of Hand pump with all acessoceries |
| 223 | 10 mm service wire |
| 224 | 25/40 mm dia G.I. Socet /R socket |
| 225 | Massari Jali |
| 226 | WATER SUPPLY Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40 with fitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace & PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/AKG.-20 mm dia C-PVC pipe (Oriplast/Supreme) |
| 227 | Staff quarter |
| 228 | Office Building |
| 229 | 25 mm dia C-PVC pipe (Oriplast/Supreme)-Staff quarter |
| 230 | Office Building |
| 231 | 32 mm dia C-PVC pipe SDR.11 (Supreme/Ashirbad/ASTRAL.)-Staff quarter |
| 232 | Office Building |
| 233 | 40 mm dia C-PVC pipe (Oriplast/Supreme)-Staff quarter |
| 234 | Office Building |
| 235 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall |
| 236 | Staff quarter |
| 237 | Office Building |
| 238 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 239 | Staff quarter |
| 240 | Office Building |
| 241 | SANITARY FIXTURES.-Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge. (EWC with Wall Hung Cistern, Drainage L Bend Pipe, Gasket and Installation Kit with PP normal close seat cover, Hinges, Fixing Accessories and Accessories set, Size: 350x480x395 mm, STrap)-CNS-WHT-551SNPP184LZ (Make: Jaquar) |
| 242 | Staff quarter |
| 243 | Office Building |
| 244 | Supplying all materials, labour, T&P and fixing standard sized LONG BODY Bib cock WITH WALL FLANGE of Hindware/ Jaquar/ Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange Cat. No.: F330011 HINDWARE |
| 245 | Staff quarter |
| 246 | Office Building |
| 247 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge./ JAQUAR-ALD-577 Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) |
| 248 | Staff quarter |
| 249 | Office Building |
| 250 | Supplying all materials, labour, T&P and fixing standard sized Two way Bib cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange jaquar FLR-5041N |
| 251 | Staff quarter |
| 252 | Office Building |
| 253 | Supplying all materials, labour, T&P and fixing standard sized Bib cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange.(HINDWARE Cat. No.: F730041) |
| 254 | Staff quarter |
| 255 | Office Building |
| 256 | Matrix Set-1 (Wash Basin 46x36 cm with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, one no hinged rail 76 cm and 4 nos of grab rail 60cm) Make-Hinware-Matris Set-Code-70002, EWC (P-18) |
| 257 | Office Building |
| 258 | Supplying, installing, testing and commissioning of approved make White Viterous urinals 3.8 LPM supported by CI/MS bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flusing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains etc, complete. Including necessary wall cutting/chasing and making good, as required. , jaquar,Size:385x325x635mm,jaquar-URS-WHT-13253N |
| 259 | Office Building |
| 260 | Supplying all materials, labour T&P and fixing URINAL FLUSH VALVE FLV-1095NG (Make: Jaquar) of approved make etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge |
| 261 | Office Building |
| 262 | Supply and fixing all materials, labour, T & P and providing granite slab urinal partion wall including cutting grooves in wall and making good the damages, watering, curing, conveyance of all materials to work site etc all complete as per direction of the Engineer-In-Charge.SIZE(1X0.75X0.50) |
| 263 | Office Building |
| 264 | Supplying all materials, labour T&P and fixing HALF Pedestal type wash basins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer-In-Charge.-Jaquar ARS-WHT-39305 |
| 265 | Staff quarter |
| 266 | Office Building |
| 267 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Shower of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. SHOWER HEAD,SHOWER ARM,ANGULAR STOP COCK |
| 268 | Staff quarter |
| 269 | Office Building |
| 270 | Supplying all materials, labour, T&P and fixing standard sized pillar cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia fus Jaquar,Cat No- PRS-031 |
| 271 | Staff quarter |
| 272 | Office Building |
| 273 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. 600mmx450mm size B.E.mirror (Alpina/Golden fish/Belgion) |
| 274 | Staff quarter |
| 275 | Office Building |
| 276 | Supplying all materials, labour, T&P and fixing standard sized Robe Hook of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Jaquar ACN-1161N |
| 277 | Staff quarter |
| 278 | Office Building |
| 279 | Supplying all materials, labour, T&P and fixing standard sized 15mm dia angular Stop cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange .jaquar,Cat No-CQT-23059 |
| 280 | Staff quarter |
| 281 | Office Building |
| 282 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 283 | Staff quarter |
| 284 | Office Building |
| 285 | Fixing of 32mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- Zoloto or equivalent.) |
| 286 | Staff quarter |
| 287 | Office Building |
| 288 | Fixing of 25mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 289 | Staff quarter |
| 290 | Office Building |
| 291 | Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 PSS UV of size 750x570x1350 mm height with water storage capacity 80 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC. |
| 292 | Staff quarter |
| 293 | Office Building |
| 294 | Supplying all materials labour T&P and fixing Kitchen sink of stainless steel kitchen (600 x 450 x 250) mm of approved make etc complete including cost of all materials complete as per PH specification and direction of EIC. |
| 295 | Supplying all materials, labour , T&P and fixing standard sized SINK cock of Hindware/Jaguar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of EIC. |
| 296 | Supplying all materials, labour T&P and fixing standard sized chromium plated brass towel ring of Hindware/Jaguar/Parryware complete with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws as per specification and direction of the Engineer in charge (Towel ring round & round flange) |
| 297 | Supplying all materials, labour T&P and fixing standard sized chromium plated paper holder of Hindware/Jaguar/Parryware complete with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws as per specification and direction of the Engineer in charge |
| 298 | Fixing Rotational moulded Poly Propelene double layer cylindrical vertical water storage tanks confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge.-2000 Ltr |
| 299 | Staff quarter |
| 300 | Office building |
| 301 | SEWAGE SYSTEM.-Supplying all materials, labour, T & P and constructing of Inspection chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge.(Size- 600 x 600 x 450 mm) |
| 302 | Staff quarter |
| 303 | office building |
| 304 | Providing and fixing square mouth S.W GULLY TRAP(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge (Size- 300x300 mm) |
| 305 | Staff quarter |
| 306 | office building |
| 307 | Supplying all materials, labour, T & P and constructing of MAN HOLE chamber(M H) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. (Man-hole chamber of size 1200x900x900mm ) |
| 308 | Staff quarter |
| 309 | office building |
| 310 | Supplying, fixing and testing PVC soil, waste, Rain and vent pipes (SWR) SUPREME confirming to IS13592 : 1990, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini |
| 311 | Staff quarter -40 mm dia .ASTRAL-M081060304 |
| 312 | 75 mm dia .(ASTRAL -M341110307) |
| 313 | 110 mm dia .(ASTRAL -M341110309) |
| 314 | 160 mm dia Rain pipe. ( SENTINI FLOW PIPE BS0009SP3M) |
| 315 | Office building -40 mm dia .ASTRAL-M081060304 |
| 316 | 75 mm dia .(ASTRAL -M341110307) |
| 317 | 110 mm dia .(ASTRAL -M341110309) |
| 318 | 160 mm dia Rain pipe. ( SENTINI FLOW PIPE BS0009SP3M) |
| 319 | Supplying, fixing and testing PVC muilty floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. MAKE- Astral-M252003236-110 mm dia (SENTINI NM5609SFPL) |
| 320 | Staff quarter |
| 321 | office building |
| 322 | Supplying, fixing and testing PVC Nahani floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. MAKE- Astral-M252003236-75 mm dia (SENTINI NF4334SFPL) |
| 323 | Staff quarter |
| 324 | office building |
| 325 | Providing ,fixing , testing and commissioning of approved make PVC vent cowl with necessary accessories etc., complete. Make-Astral,page-06 |
| 326 | Staff quarter- 75 mm dia (ASTRAL -M212002707) |
| 327 | 110 mm dia (ASTRAL -M212002709) |
| 328 | office building -75 mm dia (ASTRAL -M212002707) |
| 329 | 110 mm dia (ASTRAL -M212002709) |
| 330 | Providing and fixing Clean Out |
| 331 | Staff quarter -75 mm dia (SENTINI SF1007SFPL) |
| 332 | 110 mm dia (SENTINI SF1009SFPL) |
| 333 | office building -75 mm dia (SENTINI SF1007SFPL) |
| 334 | 110 mm dia (SENTINI SF1009SFPL) |
| 335 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 336 | Staff quarter -GROUP-A |
| 337 | GROUP-B |
| 338 | GROUP-C |
| 339 | office building -GROUP-A |
| 340 | GROUP-B |
| 341 | GROUP-C |
| 342 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 343 | Staff quarter |
| 344 | office building |
| 345 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & coverincluding supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 346 | Staff quarter |
| 347 | office building |
| 348 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 349 | Staff quarter |
| 350 | office building |
| 351 | Supplying, fixing of 1x6A+1x1 6A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) (anti bactorial & flame retradant type) with suitable size modular box & metalic cover plate (both side) (anti bactorial & flame retrtadant type) including supplying of all requireds accessories of ISI marked as approved as per direction of Engineer-inc-charge. Make Schneider (Zencelo)/Legrand (Myrius-NEXT-GEN)/Panasonic (Vision) (For equipment power) (Maximum 02 nos point in one circuit). All the switches & sockets should be arrantied for a replacement period of 2 years against defects with necessary test report & warranty certificate to be submitted to the departmentfor genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 352 | office building |
| 353 | Supplying, fixing of 3x6A+1x1 6A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) (anti bactorial & flame retradant type) with suitable size modular box & metalic cover plate (both side) (anti bactorial & flame retrtadant type) including supplying of all requireds accessories of ISI marked as approved as per direction of Engineer-inc-charge. Make Schneider (Zencelo)/Legrand (Myrius-NEXT-GEN)/Panasonic (Vision) (For equipment power) (Maximum 02 nos point in one circuit). All the switches & sockets should be arrantied for a replacement period of 2 years against defects with necessary test report & warranty certificate to be submitted to the departmentfor genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 354 | office building |
| 355 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 356 | Staff quarter |
| 357 | office building |
| 358 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 359 | Staff quarter |
| 360 | office building |
| 361 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 362 | Staff quarter |
| 363 | office building |
| 364 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 365 | Staff quarter |
| 366 | office building |
| 367 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/Anchor/Polycab/HAVELLs/RRKable/KEI in recessed HMS FRLS PVC conduit of mentioned size Make:AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Eng-incharge. 4 nos single core 6sq.mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuity conductor in 32 mm dia non metalic heavy duty conduit (LFDB TO LBDB/Medical equipment) 4x6+2x4) |
| 368 | office building |
| 369 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/Anchor/Polycab/HAVELLs/RRKable/KEI in recessed HMS FRLS PVC conduit of mentioned size Make:AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Eng-incharge. 4 nos single core 10sq.mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuity conductor in 32 mm dia non metalic heavy duty conduit (LFDB TO FLOOR PANEL to TPN BDB Power) 4x10+2x6) |
| 370 | office building |
| 371 | Supplying and installation of AC point having 16-20A DP MCB,C series with enclosure, Schneider/Siemens/Legrand/ABB c suitable size as required as per direction of Eng-in-charge. All the componentgs should be warrantied for a replacement period of 1 years against defects with necessary test report & warranty certificate tio be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 372 | office building |
| 373 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 374 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 375 | Staff quarter |
| 376 | office building |
| 377 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 378 | Staff quarter |
| 379 | office building |
| 380 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 381 | Staff quarter |
| 382 | Sub-Head II (Light fitting Fixture & Fan)-Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 383 | Staff quarter |
| 384 | office building |
| 385 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 386 | Staff quarter |
| 387 | office building |
| 388 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 389 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W (2'x2') 595mmx595mmx70mm and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 390 | office building |
| 391 | Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, bottom opening clean room LED luminaire of 600 X 600 x 65 mm size with of 36 W and system lumens output not less than 3600 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .Each CLEAN ROOM FITTING . |
| 392 | office building |
| 393 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 394 | office building |
| 395 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 396 | Staff quarter |
| 397 | office building |
| 398 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 399 | Staff quarter |
| 400 | office building |
| 401 | SITC of Sleek LED 9 watt LED lamp complete with all accessories etc directly on angle holder as required. The luminaire should be replacement warranty will be 2 years. (Panasonic/Havells/LT/Bajaj/Phillips/Crompton/Wipro). |
| 402 | Staff quarter |
| 403 | Supplying and fixing of 10 Watt LED BH fitting. The luminaire should be replacement warranty will be 2 years. (Panasonic/Havells/LT/Bajaj/Phillips/Crompton/Wipro) |
| 404 | Staff quarter |
| 405 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 406 | Staff quarter |
| 407 | office building |
| 408 | Supplying and fixing of energy efficeint surface/recess mounted square /round shape 18 WLED luminaire of demension consists of white powder coated, die-cast. Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens. CRI not less than 80, CCT of 6000 degree K,THD less than 10% with electronic driver, internal surge protection of 3 KV, L70 B50 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg-in-charge. (Make:Panasonic/LT/Havells/Phillips/Wipro/Crompton/Bajaj). The luminaire should be replacement warranty will be 2 years. |
| 409 | Staff quarter |
| 410 | Supplying, installation, testing & commissioning of 1 KVA, 240V UPS with all required accessories & suitable nos 12V battery, 220Ah tubular type battery rack as per direction of Engineer-in-charge. Make: V-Guard/Microtech/Luminous (only for common area) |
| 411 | Staff quarter |
| 412 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) |
| 413 | office building |
| 414 | BDBS,DB,AC DB,FLOOR PANELS,MCBS-Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel, double door MCB distribution board 415 volts/240 volts shall be as per IEC 61439-3, integrated door earthing system offering additional safety to the user, high quality polyurethane Gasket the box and cover shall be fabricated to withstand IK09, the DB should be properly pre-traeted with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks, tinned copper busbar, neutral busbar, earth bar, dinbar. Make:LEGRAND-Ekinox3 DB/Siemens-Betaguard/Scheneider-Acti 9/ABB itus as per direction of EIC. The distgribution boards should be replacement warranty will be 3 years. |
| 415 | Staff quarter |
| 416 | office building |
| 417 | Supply & fixing of 12 way DD single pole and neutral sheety MCB distribution board 250V on surface/recess complete with tinned copper busbar neutral earth bar din bar detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but with out MCB/RCCB/Isolator) warranty on DB is 3 years. (QTR & COMMON) |
| 418 | Staff quarter |
| 419 | office building |
| 420 | 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 421 | office building |
| 422 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years |
| 423 | office building |
| 424 | Supply & fixing 6 amps to 32 amps rating , 240 volts, C series, 10KA breaking capacity. Single poles MCB of make-LEGRAND-DX3 / Siemens-Betaguard/Scheneider-Acti 9 /ABB SB 200 model of ABB /LK/Hager /C&S/Havells/Panasonic the existing MCB DB complete with connections as per direction of EIC. Warranty on MCB is 1 year. |
| 425 | office building |
| 426 | Staff quarter |
| 427 | Supply & fixing 6 amps to 32 amps rating , 240 volts, C series, 10KA breaking capacity. Single poles MCB of make-LEGRAND-DX3 / Siemens-Betaguard/Scheneider-Acti 9 /ABB SB 200 model of ABB /LK/Hager /C&S/Havells/Panasonic the existing MCB DB complete with connections as per direction of EIC. Warranty on MCB is 1 year. |
| 428 | office building |
| 429 | Staff quarter |
| 430 | Supplying and fixing 40 Amps 4p 415Volt MCV Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 431 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 432 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 433 | Supplying and fixing 63 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 434 | office building |
| 435 | Staff quarter |
| 436 | Supply & fixing 6 amps to 32 amps rating , 240 volts, C series, 10KA breaking capacity. Single poles MCB of make-LEGRAND-DX3 / Siemens-Betaguard/Scheneider-Acti 9 /ABB SB 200 model of ABB /LK/Hager /C&S/Havells/Panasonic the existing MCB DB complete with connections as per direction of EIC. Warranty on MCB is 1 year. |
| 437 | office building |
| 438 | Staff quarter |
| 439 | Supplying and fixing 6 amps to 32amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 440 | Supplying and fixing 6 amps to 32amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 441 | (Earthing) INSTALLATION-S/IT/C of earthing with GI earth plate 600 mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe etc (with charcoal and salt) as required as per direction of EIC. |
| 442 | Staff quarter |
| 443 | office building |
| 444 | Supplying,installation,testing & commissioning of materials and installation ofcopper earth plate 600mmx600mmx3.18mm thick ISI marked with copper nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 445 | office building |
| 446 | Providing and 6 SWG GI wire on surafce or in recess for loop earthing as required as per direction of EIC |
| 447 | Providing and fixing 25mm x 5mm GI strip on surface or n recess for connections etc as required as per direction of EIC (DOUBLE RUN TO MAIN PANEL & APFC PANEL, AC PANEL) |
| 448 | Staff quarter |
| 449 | office building |
| 450 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 451 | CABLING AND END TERMINATION MAIN AREA-Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 452 | Staff quarter -3.5core x 95 sq mm |
| 453 | 4core x 16 sq mm (LIFT,SERVICES,DG-2 RUNS) |
| 454 | Office building -3.5core x 95 sq mm ( FOR FDB 1F, POWER ) |
| 455 | 4core x 16 sq mm (BDB LIGHT /POWER,EQUIPEMENT ) |
| 456 | 4 core x 6 sq mm (for small power) |
| 457 | 3.5core x 50 sq mm |
| 458 | LAYING OF CABLE-Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 459 | Staff quarter |
| 460 | office building |
| 461 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 462 | Staff quarter |
| 463 | office building |
| 464 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 465 | Staff quarter |
| 466 | office building |
| 467 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 468 | office building |
| 469 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 470 | office building |
| 471 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 472 | office building |
| 473 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 474 | office building |
| 475 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 476 | Staff quarter |
| 477 | office building |
| 478 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 479 | Staff quarter |
| 480 | office building |
| 481 | Laying of PVC insulated PVC seated / XLPE power cable of 11KV grade size not exceeding 400 SQ MM in surface with shaddle and screw etc as required as per direction of EIC. |
| 482 | Staff quarter |
| 483 | office building |
| 484 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 485 | Staff quarter |
| 486 | Staff quarter |
| 487 | Office building -4 core x16sq mm |
| 488 | Office building -3.5 core x50 sq mm |
| 489 | Office building -3.5 core x95 sq mm |
| 490 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 491 | Staff quarter -50 mm dia |
| 492 | Office building -50 mm dia |
| 493 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 494 | 200 mm dia |
| 495 | PANELS -MAIN CONTROL PANEL AT GF -1 no. 3P+N 65kA/POLE type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(TYPE-I)(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) |
| 496 | Staff quarter |
| 497 | office building |
| 498 | UPS SYSTEM( COMMON AREA)-Supply ,installation ,testing & commissioning of 5KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 8 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD OF EM) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 499 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER- Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 500 | Staff quarter |
| 501 | office building |
| 502 | Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. |
| 503 | office building |
| 504 | External-S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 505 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 506 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 507 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 508 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 509 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 510 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 511 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 512 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 513 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 514 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent |
| 515 | Staff quarter |
| 516 | office building |
| 517 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent |
| 518 | Staff quarter |
| 519 | office building |
| 520 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 521 | Staff quarter |
| 522 | office building |
| 523 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB/Equivalent |
| 524 | Staff quarter |
| 525 | office building |
| 526 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent |
| 527 | Staff quarter |
| 528 | office building |
| 529 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 530 | Staff quarter |
| 531 | office building |
| 532 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB/Equivalent |
| 533 | Staff quarter |
| 534 | office building |
| 535 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB/Equivalent |
| 536 | Staff quarter |
| 537 | office building |
| 538 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent |
| 539 | Staff quarter |
| 540 | office building |
| 541 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB/Equivalent |
| 542 | Staff quarter |
| 543 | office building |
| 544 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 545 | Staff quarter |
| 546 | office building |
| 547 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent |
| 548 | Staff quarter |
| 549 | office building |
| 550 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 551 | Staff quarter |
| 552 | office building |
| 553 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB/Equivalent |
| 554 | Staff quarter |
| 555 | office building |
| 556 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB/Equivalent |
| 557 | Staff quarter |
| 558 | office building |
| 559 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB/Equivalent |
| 560 | Staff quarter |
| 561 | office building |
| 562 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB/Equivalent |
| 563 | Staff quarter |
| 564 | office building |
| 565 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB/Equivalent |
| 566 | Staff quarter |
| 567 | office building |
| 568 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 569 | Staff quarter |
| 570 | office building |
| 571 | FIRE EXTINGUISHERS-Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required. Make-Safex/Fireshield/Ceasefire |
| 572 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire |
| 573 | Providing and Fixing of of 2 kG capacity Eco Friendly, Stored pressure type filled with HFC 134 A ( clean agent fire extinguishant having Zero Ozone depletion potential ) Clean Agent Fire Extinguishers with safety seal, pressure guage, controllable discharge mechanism, helium leak detection tested and conforming to IS 15683 complete with initial charge as required.Make-Safex/Fireshield/Ceasefire |
| 574 | Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.Make-Safex/Fireshield/Ceasefire |
| 575 | Fire buckets round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 576 | Fire bucket stand fabricated by MS angles to install 2 Nos. of buckets. |
| 577 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj |
| 578 | Illumination Glow light for Exit Indication with Battery Back-up. |
| 579 | ON GRID SOLAR PV SYSTEM-Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Kamal Solar/ EMMVEE/ Venus / Anchor by panasonic . The entire SOLAR system should be Replacement Warranty will be 5 years |
| 580 | Transformer-Supplying & installation of 100x116 mm RS Joist, 9 mtr long x 2 nosx23 Kg=414 Kg |
| 581 | Supplying & installation of Pressure Channel 100 x 50 x 6mm MS channel each 2.8 mtr. Long( 9.2 K.g. per mtr.)x2 Nos |
| 582 | Supplying & installation of S/S 2 Pole bressing chhanel 75 x 40 x 6mm MS channel each 2.8 mtr. Long( 6.8 K.g. per mtr.)x2 Nos |
| 583 | Supplying & installation of AB Swith & HG Fuse, Mounting Channel 75x40x6 -2.8 mtr.long, 4 nos.(6.8K.g. per mtr.) |
| 584 | Supplying & installation of Cantilever chhanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.) |
| 585 | Contilever chhanel for supporting HG Fuse 50 x 50 x 6 mm MS Angel (1.0 mtrs. Long 2 nos.)4.5K.g. per mtr. |
| 586 | Supplying & installation of Angle for Cantilever arrrangement for AB Switch & HG Fuse 50 x 50 x 6 -2 mtr .each 2 nos.(4.5 K.g. per mtr.) |
| 587 | Supplying & installation of S/S 2P bressing Angle 50 x 50 x 6 mm - 2.8 mtr. Long 2 nos.(4.5 K.g. per mtr.) with side angel ( Total 9 mtr.) |
| 588 | Supplying & installation of Angle for mounting LT distribution Box 50 x 50 x 6 mm MS Angel -2.5 mtrs.each Long 2 nos.( 4.5 K.g. per mtr.) |
| 589 | Supplying & installation of 11KV AB Switch 3 Pole (1000 Amp.) |
| 590 | Supplying & installation of 11KV HG Fuse 3 Pole (800Amp.) |
| 591 | Supplying & installation of11 KV L.A. 12KV-10KA |
| 592 | Supplying & installation of+B7 H.T.stay set ( Complete ) |
| 593 | Supplying & installation of H.T. Stay Insulator |
| 594 | Supplying & installation of H.T. Stay clamp (1.95 K.g./ Pair ) |
| 595 | Supplying & installation of 7/10 SWG Stay Wire |
| 596 | Supplying & installation of of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 597 | Supplying & installation of 25X5 MM G.I STRIP |
| 598 | Supplying & installation of 40x6mm GI Flat for nutral |
| 599 | Fixing of stay set with 0.5Cum cement concret foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labour and material except stay set , stay wire , stay insulator . |
| 600 | Concreting of support C.C - 1:4:8 using 40mm BHG metal size - 5'x2'x2' = 20CFT = 0.570CumPadding 900x600x150mm = 0.081 0.651Cum @ 3071.25= 1999.38 each |
| 601 | Couping of support section 15''x15'' ( 3.9Cft) height 2'-6' ( 1' - 6'' above G.L & 1' - 0' below G.L ) in C.C 1:2:4 using 12mm BHG metal & curing for 5 days |
| 602 | Supplying & installation of Materials for Machinery work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover |
| 603 | 3cx50 sq. mm XLPE cable.,11kv ,2 runs For 500KVA |
| 604 | Supplying and making out door end termination with cast resin compound aluminium lugs and other jointing materials for 3cx50 sq.mm size of PVC insulated armoured and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. |
| 605 | Supplying & installation of 50x6mm copper Z clamp for TFR LT 4nos x0.8kg each for connection of LT cable |
| 606 | Supplying & installation of Red Oxide paint |
| 607 | All. Paint for painting of pole & transformer. |
| 608 | Black Paint for painting of angle & channel. |
| 609 | Supplying & installation ,fixing of Ms Nut , Bolt & Washer |
| 610 | Supply, erection , testing and commissioning of 100KVA 11000V / 433V, 3 phase 50 Hz, copper winding Delta-Star, Dyn11, Step-down, Cast Resin- Oil cooled type Transformer with On load tap changer from +10% to -15% in steps of 1.56%. with compelete inspection by concerned electrical inspector with proper testing certificate Cable termination box on HT and LT side. 1 no. CT ,class PS duly fitted and connected shall be provided for the neutral. Neutral shall be solidly earthed. The indications for the bucholz's relay, oil temperature, winding temperature, alarm to be indicated in the Main LT panel respectively. The transfromer shall be suitable for connecting sandwich type busduct from Main LT panel. |
| 611 | Supplying & installation of 100x116mm RS Joist 4mtr longx23kg for resting of LT cable |
| 612 | Construction of Plinth for TFR 6ft hight (below GL4ft)x10ftx0ft |
| 613 | Barbed Fencing (size 15'x15' )with constn. of retaining wall ,erection of RCC fencing post, Sand filling and metal spreading, Fixing of Iron gril gate etc as per CESU specification |
| 614 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required. |
| 615 | Sundries for survey , PVC tape, Ampire tape,Danger Board, small size nut & Bolt preparation of drawing cable socket etc |
| 616 | LIGHT SYSTEM (External illumination) S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 617 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakrangee/Valmont) as per direction of Engg. in Charge.(with single arm) |
| 618 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 619 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 5years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 620 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years |
| 621 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 622 | CABLING Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/KEI/HAVELLS ISI MARKED MAKE of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 623 | 4core x 16 sq mm |
| 624 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 625 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 626 | 4core x 16 sq mm |
| 627 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 628 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 629 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 32A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 32 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB-SB 200 as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 year of acceptance of materials |
| 630 | DISPLAY BOARD |
| 631 | 40 KVA DG Set-Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 40KVA ( Make -Kirloskar / Jakson/Mahindra) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years / ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. / ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 40KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standards / AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 40KVA DG Set complete with Battery Charger & leads as required. / BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. / FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. , control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender